Инструкция обслуживания Agilent Technologies 81133A

12 страниц 3.41 mb
Скачать

Перейти на страницу of 12

Summary
  • Agilent Technologies 81133A - page 1

    Y ou only need a few minutes to get started with the Agilent 81133A and 81134A Pulse Generator . This Getting Started Brochure helps you to quickly understand the operating principles and set up your first signals. If you need more detailed information on the Agilent 81133A and 81134A Pulse Generator , check out the Online Help. Getting Started wit ...

  • Agilent Technologies 81133A - page 2

    Notice 2 Safety Summary Copyright Revision © Agilent T echnologies, Inc. 2002. Revision 1.0, August 2002 Printed in Germany Agilent T echnologies, Deutschland GmbH Herrenberger Str . 130 71034 Boeblingen, Germany T echnology Licenses The hardware and/or software described in this document are furnished under a license and may be used or copied onl ...

  • Agilent Technologies 81133A - page 3

    Installing the Agilent 81133A and 81134A Check if the Agilent 81133A or 81134A shipping container contains the following standard deliverables: If the contents are incomplete, if there is mechanical damage, or if the instrument does not work within its specifications, notify the nearest Agilent office. The Agilent office will arrange for repair or ...

  • Agilent Technologies 81133A - page 4

    Getting Started with the Agilent 81133A and 81134A Now that you have unpacked the instrument and plugged it in, let´s take a look at the main elements of the front panel. Switch on the instrument. Y ou can immediately start playing with the settings. Start by pressing the tab keys. Y ou see that only the lower part of the panel page changes. Y ou ...

  • Agilent Technologies 81133A - page 5

    Changing Parameters The navigation knob makes it easy to move through and set the parameters. Rotate the navigation knob to move from one parameter to the next. Let’ s select a parameter from a selection list. Press the navigation knob to open the selection list (like clicking with the mouse). Rotate the navigation knob to scroll through the list ...

  • Agilent Technologies 81133A - page 6

    Changing Parameters Now let´s change a number field Press the navigation knob once to focus at the number field. T urn the navigation knob to set the number Release the navigation knob. Now when you rotate it, the number changes. Press the navigation knob once when you are done. Y ou can also: 6 When you rotate the navigation knob the value change ...

  • Agilent Technologies 81133A - page 7

    Setting Up a Data Pattern Imagine, you have designed a new digital circuit with ECL logic and 3.3 GHz clock, and you want to check its correct behavior . T o test it, you decide to simulate a 32-bit pattern signal with NRZ data output format: 7 11110011100110010010100100000000 Now let’ s set the instrument parameters Whenever you change a paramet ...

  • Agilent Technologies 81133A - page 8

    Setting Up a Data Pattern 8 Y ou can now set the channel mode, timing and level parameters for the channel Switch to the Channel Page Select Pulse Mode Data Select Pulse T ype NRZ Select the ECL level format Indicates that the Parameters are set for Channel 1 Y ou can switch between the two channels by pressing this softkey 1 2 3 4 The LEDs show th ...

  • Agilent Technologies 81133A - page 9

    Setting Up a Data Pattern 9 Reconnect the DUT When you are done, you can reconnect the DUT by clicking the following softkey: If you attach a scope (as DUT), you can immediately see the signal Y ou can use the generator’ s trigger output to trigger the scope. Switch to Aux Page Enable the T rigger Output ... The LEDs tell you which outputs are en ...

  • Agilent Technologies 81133A - page 10

    What Else Y ou Can Do 10 Fast rise times, low jitter and full parameter flexibility PRBS from 2 -1 to 2 -1 53 1 Full signal manipulation Predefined Levels When timing is critical, the 81133/34A ’ s fast rise times, the low jitter and full parameter flexibility make it an ideal pulse, clock and data source. Y ou can evaluate the performance of a d ...

  • Agilent Technologies 81133A - page 11

    Requirements and Possibilities for Remote Control 11 Using the Pulse Generator's Remote Control Interfaces Y ou can integrate the Pulse Generator in your production environment. Its remote programming interfaces (USB, LAN, GPIB) allow you to set up extensive tests that involve several instruments. The accompanying Agilent I/O Libraries for ins ...

  • Agilent Technologies 81133A - page 12

    Agilent Corporate Information, Product Numbers 12 For more information, please visit us at: Ordering Information Agilent 81133A 3.35 GHz 1-channel Pulse/Pattern Generator Agilent 81134A 3.35 GHz 2-channel Pulse/Pattern Generator Agilent 8113xA-UK6 Commerical Calibration Certificate with T est Data Agilent 8113xA-1CP Rackmount and Handle kit Agilent ...

Производитель Agilent Technologies Категория Sprinkler

Документы, которые мы получаем от производителя устройства Agilent Technologies 81133A мы можем разделить на несколько групп. Это в частности:
- технические чертежи Agilent Technologies
- инструкции обслуживания 81133A
- паспорта изделия Agilent Technologies
- информационные брошюры
- энергетические этикетки Agilent Technologies 81133A
Все из них важны, однако самую важную информацию с точки зрения пользователя мы найдем в инструкции обслуживания Agilent Technologies 81133A.

Группа документов, определяемая как инструкции обслуживания, делится также на более подробные типы, такие как: Инструкции монтажа Agilent Technologies 81133A, инструкции обслуживания, короткие инструкции или инструкции пользователя Agilent Technologies 81133A. В зависимости от потребностей, Вам необходимо поискать требуемый документ. На нашем сайте Вы можете просмотреть самую популярную инструкцию использования изделия Agilent Technologies 81133A.

Похожие инструкции обслуживания

Полная инструкция обслуживания устройства Agilent Technologies 81133A, как должна выглядеть?
Инструкция обслуживания, определяемая также как пособие пользователя, или просто "руководство" - это технический документ, цель которого заключается в использовании Agilent Technologies 81133A пользователями. Инструкции пишет, как правило технический писатель, языком, доступным для всех пользователей Agilent Technologies 81133A.

Полная инструкция обслуживания Agilent Technologies, должна заключать несколько основных элементов. Часть из них менее важная, как например: обложка / титульный лист или авторские страницы. Однако остальная часть, должна дать нам важную с точки зрения пользователя информацию.

1. Вступление и рекомендации, как пользоваться инструкцией Agilent Technologies 81133A - В начале каждой инструкции, необходимо найти указания, как пользоваться данным пособием. Здесь должна находится информация, касающаяся местонахождения содержания Agilent Technologies 81133A, FAQ и самых распространенных проблем - то есть мест, которые чаще всего ищут пользователи в каждой инструкции обслуживания
2. Содержание - индекс всех советов, касающихся Agilent Technologies 81133A, которое найдем в данном документе
3. Советы по использованию основных функций устройства Agilent Technologies 81133A - которые должны облегчить нам первые шаги во время использования Agilent Technologies 81133A
4. Troubleshooting - систематизированный ряд действия, который поможет нам диагностировать а в дальнейшем очередность решения важнейших проблем Agilent Technologies 81133A
5. FAQ - чаще всего задаваемые вопросы
6. Контактные данные Информация о том, где искать контактные данные производителя / сервисного центра Agilent Technologies 81133A в данной стране, если самостоятельно не получится решить проблему.

У вас вопрос, касающийся Agilent Technologies 81133A?

Воспользуйтесь формуляром, находящимся ниже

Если с помощью найденной инструкции Вы не решили свою проблему с Agilent Technologies 81133A, задайте вопрос, заполнив следующий формуляр. Если у какого то из пользователей была похожая проблема с Agilent Technologies 81133A со всей вероятностью он захочет поделиться методом ее решения.

Перепишите текст с картинки

Комментарии (0)