    Modular Instrumentation NI PCI-5911 User Manual High-Speed Digitizer with Flex ADC NI PCI-5911 User M anual ™ March 2 003 Edition Part Number 322150E-01 ...

  • National Instruments NI PCI-5911 - page 2

    Support Worldwide Technical Support and Product Info rmation ni.com National Instruments Corporate Headquarters 11500 North Mopac Expressway Aust in, Texas 78759-3504 USA Tel: 512 683 0100 Worldwide Offices Australia 02 612 9672 8846, Austria 43 0 662 45 79 90 0, Belgium 32 0 2 757 00 20, Brazil 55 11 3262 3599, Canada (Calgary) 403 274 9391, Canad ...

  • National Instruments NI PCI-5911 - page 3

    Important Information Warranty The NI 5911 is war ranted agains t defects in materi als and workmanshi p for a period of on e year from the date of shipment, as ev idenced by receipts or other documentation. National Instruments wil l, at its option, repair or replace equi pment that proves to be defect ive during the warranty period. This warrant ...

  • National Instruments NI PCI-5911 - page 4

    Compliance FCC/Canada Radio Frequency Interference Compliance Determining FCC Class The Federal Communications Commission (FCC) has rules to protect wireless co mmunications from inte rference. The FCC places digital electronics into two classes. These classes are known as Class A (for use in industrial-commercial locations onl y) or Class B (for u ...

  • National Instruments NI PCI-5911 - page 5

    © National Instruments Corpor ation v NI PCI-5911 User Manual Contents About This Manual Conventions ............ .............. .............. ................. .............. .............. .............. ................ v ii Related Documentation ............ .............. ................. .............. .............. ................. .... ...

  • National Instruments NI PCI-5911 - page 6

    Contents NI PCI-5911 User Manual vi ni.com Memory ............. ............... .............. .............. .............. ................. .............. .............. ...... 2-10 Triggering and Memory Usage .............. ................. .............. ................. ......... 2-10 Multi-Record Acquisitions .... ................. ....... ...

  • National Instruments NI PCI-5911 - page 7

    © National Instruments Corporat ion vii NI PCI-5911 User Manual About This Manual The NI 5911 User Manual provides information on instal ling, connecting signals to, and acquiring d ata from your NI 5 911 high-speed digitizer . This manual includes an ov ervie w of the NI 5911 and explains the operation of each functional unit of the NI 5911. Conv ...

  • National Instruments NI PCI-5911 - page 8

    About This Manual NI PCI-5911 User Manual viii ni.com Related Documentation The following documents contain information that you mi ght find helpful as you read this manual: • Where to Start with Yo ur NI Digitizer • NI-SCOPE Software User Manual • NI-SCOPE Instrument Dri ver Quick Reference Guide Y ou can do wnload these documents from ni.co ...

  • National Instruments NI PCI-5911 - page 9

    About This Manual © National Instruments Corpor ation ix NI PCI-5911 User Manual • Pollution Degree 3 means that conductiv e pollution occurs, or dry , nonconductiv e pollution occurs that becomes condu cti ve due to condensation. Y ou must insulate signal connections for th e maximum voltage for which the device is rated. Do not e xceed the max ...

  • National Instruments NI PCI-5911 - page 10

    About This Manual NI PCI-5911 User Manual x ni.com outlets in the fix ed installation, and stationary motors with perm anent connections to fixed installations. • Installation Category IV is for measurement s performed at the primary electrical supply installation (<1,000 V). Examples include electricity meters and measurements on primar y ov ...

  • National Instruments NI PCI-5911 - page 11

    © National Instruments Corporat ion 1-1 NI PCI-5911 User Manual 1 Introduction Thank you for buyin g an NI PCI-5911 digiti zer, featuring the Flex ADC for variable speed and resolution. This chapter contains information on installing, connecting signals to, and acquiring data from the NI 5911 Installing the NI 5911 Installation invol ves the follo ...

  • National Instruments NI PCI-5911 - page 12

    Chapter 1 Introduction NI PCI-5911 User Manual 1-2 ni.com Note The +5 V signal is fused at 1.1 A. Howe ve r , NI recommends limiting the current from this pin to 30 mA. The fuse is self-resetti ng. Figure 1-1. NI 5911 Connectors CH 0 PFI 1 PFI 2 (DIN) ...

  • National Instruments NI PCI-5911 - page 13

    Chapter 1 Introduction © National Instruments Corporat ion 1-3 NI PCI-5911 User Manual Figure 1-2. 9-Pin Mini-Cir cular DIN Connector Acquiring Data with the NI 5911 You can acquire data either programm atically—by w ritin g an application for the NI 5911—or interactiv ely with the Scope Soft Fron t Panel. Programmatically Controlling the NI 5 ...

  • National Instruments NI PCI-5911 - page 14

    Chapter 1 Introduction NI PCI-5911 User Manual 1-4 ni.com NI-SCOPE Function Reference Help , located at Start»Programs» National Instru ments»NI-SCO PE . For more detailed VI help, use LabVIEW context-sensiti v e help ( Help»Show Context Help ) or the NI-SCOPE VI Reference Help , located at Start»Programs»National Instruments»NI-SCOPE . Inte ...

  • National Instruments NI PCI-5911 - page 15

    © National Instruments Corporat ion 2-1 NI PCI-5911 User Manual 2 Hardware Over view This chapter includes an overview of the NI 5 911, explains the operation of each functional unit making up the NI 5911, and describes the signal connections. Figure 2-1 shows a block diagram of the NI 5911. Figure 2-1. NI 5911 Block Diagram Differential Programma ...

  • National Instruments NI PCI-5911 - page 16

    Chapter 2 Hardware Overview NI PCI-5911 User Manual 2-2 ni.com presented at the negative input is subt racted from the signal presented at the positive input. As shown in Figure 2-2, this subtraction rem oves ground noise from the signal. The inner conductor of th e BNC is V+. The outer shell is V–. Figure 2-2. Signa l Noise-Free Measurem ents Gr ...

  • National Instruments NI PCI-5911 - page 17

    Chapter 2 Hardware Overview © National Instruments Corporat ion 2-3 NI PCI-5911 User Manual Input Ranges To optimize the ADC resolution, you can select different gains for the PGIA so that you can scale your input signal to match t he full input range of the converter. The NI 5911 PGIA o ffers seven input ranges, fro m ±0.1 V to ±10 V, as shown ...

  • National Instruments NI PCI-5911 - page 18

    Chapter 2 Hardware Overview NI PCI-5911 User Manual 2-4 ni.com where V m is the measured v oltage, V s is the source v oltage, R s is the e xternal source impedance, and R in is the input impedance. If the de vice you are measuring has a very lar ge output impedance, your measurements will be af fected by th is impedance divider . For example, if t ...

  • National Instruments NI PCI-5911 - page 19

    Chapter 2 Hardware Overview © National Instruments Corporat ion 2-5 NI PCI-5911 User Manual to allo w an 8-bit digitizer to acquire accurate data. Howe v er , the NI 5911 in flexible resolution mode is much more precise and thus requires a greater number of time constants of settling ti me to achiev e the desired precision. Refer to Appendi x A, D ...

  • National Instruments NI PCI-5911 - page 20

    Chapter 2 Hardware Overview NI PCI-5911 User Manual 2-6 ni.com Flexible Resolution Mode Table 2-2 shows the relationship between the avail able sampling rates, resolution, and the corresponding bandwidt h for flexible resolution mode. Like an y other type of con v erter that uses noise shaping to enhance resolution, the frequency response of the co ...

  • National Instruments NI PCI-5911 - page 21

    Chapter 2 Hardware Overview © National Instruments Corporat ion 2-7 NI PCI-5911 User Manual Calibration The NI 5911 can be calibrated for high accuracy and resolution because of an advanced calibration sch eme. Th ere are two different types of calibration: internal, or self-calibrati on, and external calibration. A third option, internal restore, ...

  • National Instruments NI PCI-5911 - page 22

    Chapter 2 Hardware Overview NI PCI-5911 User Manual 2-8 ni.com • The linearity of the ADC is calibrated using an internal sine wav e generator as reference. • The time-to-digital con verter used for RIS measurements is calibrated. Caution Do not apply high-amplit ude or high-frequency signals to the NI 5911 during self-calibration. For optimal ...

  • National Instruments NI PCI-5911 - page 23

    Chapter 2 Hardware Overview © National Instruments Corporat ion 2-9 NI PCI-5911 User Manual Figure 2-3. T rigger Sources Analog T rigger Circuit The analog trigger on the NI 591 1 operates by comparing the current analog input to an onb oard threshold voltage. This threshold voltage is the trigger value, and can be set within the current inpu t ra ...

  • National Instruments NI PCI-5911 - page 24

    Chapter 2 Hardware Overview NI PCI-5911 User Manual 2-10 ni.com T rigger Holdoff Trigger holdoff is the minimu m length of time (in seconds) from an accepted trigger to the start of the ne xt record. In other words, when a trigger is accepted, the trigger counter is loaded with the desired holdoff time. After completing it s current record, the dig ...

  • National Instruments NI PCI-5911 - page 25

    Chapter 2 Hardware Overview © National Instruments Corporat ion 2-11 N I PCI-5911 User Manual Multi-Record Acquisitions After the trigger has been received a nd the posttrigger samples have been stored, the NI 5911 can be configured to begin another acquisition that is stored in another onboard memory record. This operatio n is a multi-record acqu ...

  • National Instruments NI PCI-5911 - page 26

    Chapter 2 Hardware Overview NI PCI-5911 User Manual 2-12 ni.com PFI Lines as Inputs You can select PFI 1 or PFI 2 as inputs for a trigger or a reference clock. Refer to the Synchr o niza t ion sec t ion f o r m ore informa t ion about t h e use of reference clocks in the NI 5911. PFI Lines as Outputs You can select PFI 1 or PFI 2 to output several ...

  • National Instruments NI PCI-5911 - page 27

    Chapter 2 Hardware Overview © National Instruments Corporat ion 2-13 N I PCI-5911 User Manual route that trigger over the R TSI bus to trigger the other digitizer(s). Howe v er , the trigger that is routed to the ot her digitizer(s) is sent synchronously to an internal 25 MHz clock. For more information about synchronization, refer to the NI-SCOPE ...

  • National Instruments NI PCI-5911 - page 28

    © National Instruments Corporat ion A-1 NI PCI-5911 User Manual A Specifications This appendix lists the specifications of the NI 5911. These specif ications are typical at 25 ° C unless otherwise stated. Acquisition System Bandwidth ........ ............... ................ ....... 100 MHz maximum; refer to Table 2-2, Ava ilable Sampling Rates a ...

  • National Instruments NI PCI-5911 - page 29

    Appendix A Specifications NI PCI-5911 User Manual A-2 ni.com Sample onboard memory ......... ............... 4 MB or 16 MB Memory Sample Depth 20 kS/s Fle xible Resolution 20.5 bits 10 kS/s Fle xible Resolution 21 bits * 1 ≤ n ≤ 2 24 in conv entional mode Sampling Frequency Mode Sample D epth (4 MB) Sample Depth (16 MB) 100/ n * MS/s Con ventio ...

  • National Instruments NI PCI-5911 - page 30

    Appendix A Specifications © National Instruments Corporat ion A-3 NI PCI-5911 User Manual Vertical Sensitivity (Input Ranges) Acquisition Characteristics Accuracy DC gain accuracy ......... .............. ............ ±0.05% si gnal ±0 .0001% fs for all input ranges at 1 MS/s in flexible resolution mode DC offset accuracy .... .............. ... ...

  • National Instruments NI PCI-5911 - page 31

    Appendix A Specifications NI PCI-5911 User Manual A-4 ni.com Filtering Dynamic Range Noise (excluding input-referred no ise) Sampling Fr equency Filter Mode Bandwidth Rip ple Alias Attenuation 100/ n * MS/s Con ventional 100 MHz ±3 dB N/A 12.5 MS/s Flexible Resolution 3.75 MHz ±0.2 dB –60 dB 5 MS/s Flexible Resolution 2 MHz ±0.1 dB –70 dB 2. ...

  • National Instruments NI PCI-5911 - page 32

    Appendix A Specifications © National Instruments Corporat ion A-5 NI PCI-5911 User Manual Distortion T imebase System Reference clock .......................... ............ 10 MHz Clock accuracy (as master) .. .............. .... 10 MHz ±50 ppm Clock input tolerance (as slave) ............ . 10 MHz ±100 ppm 1 MS/s 400 kHz –160 dBfs/ –104 dB ...

  • National Instruments NI PCI-5911 - page 33

    Appendix A Specifications NI PCI-5911 User Manual A-6 ni.com Clock jitter .............. .............. ................. .<75 pS rms , independent of reference cloc k source Clock compatibility ....................... .........TTL fo r both input and output Sampling clock frequencies Conventional mode .............. ......... 100/ n MHz, where ...

  • National Instruments NI PCI-5911 - page 34

    Appendix A Specifications © National Instruments Corporat ion A-7 NI PCI-5911 User Manual Sampling Methods Random interleaved sampling ................ 1 GS/s down to 200 MS/s effective sample rate, repetit ive signals only Real-time sampling ....................... ......... Up to 100 MS/s sample rate for transient and repetitiv e signals Power R ...

  • National Instruments NI PCI-5911 - page 35

    Appendix A Specifications NI PCI-5911 User Manual A-8 ni.com Calibration Self-calibration (inter nal calibration) .....Self-calibrati on is done using a software command. The calibration involves g ain, offset and linearity correction for all input ranges and input modes. Interval ............. ................. .............. .1 week, or any time ...

  • National Instruments NI PCI-5911 - page 36

    Appendix A Specifications © National Instruments Corporat ion A-9 NI PCI-5911 User Manual CE Compliance This product meets the essential re quirements of applicable European Directi ves, as amended for CE Marking, as follo ws: • Low -V oltage Directi v e (safety):73/23/EEC • Electromagnetic Compatibi lity Directiv e (EMC):89/336/EEC Note Refer ...

  • National Instruments NI PCI-5911 - page 37

    © National Instruments Corporat ion B-1 NI PCI-5911 User Manual B T echnical Support and Professional Ser vices Visit the following sections of the National Instruments Web site at ni.com for technical support an d professional services: • Support —Online technical support resources include the following: – Self-Help Resources —For immedia ...

  • National Instruments NI PCI-5911 - page 38

    Appendix B T echnica l Support and Professional Services NI PCI-5911 User Manual B-2 ni.com If you searched ni.com and could not find the answers you need, contact your local off ice or NI corporate h eadquarters. Phone numbers for our worldwide of f ices are listed at the front of this manual. Y ou also can visit the W orldwide Off ices section of ...

  • National Instruments NI PCI-5911 - page 39

    © National Instruments Corporat ion G-1 NI PCI-5911 User Manual Glossar y Symbol Pref ix V alue pp i c o 1 0 –1 2 nn a n o 1 0 –9 µ micro 10 –6 m milli 10 –3 k kilo 10 3 Mm e g a 1 0 6 Gg i g a 1 0 9 Symbols % percent + positi ve of, or plus – negati ve of, or minus /p e r °d e g r e e ± plus or minus Ω ohm A A amperes A/D analog to ...

  • National Instruments NI PCI-5911 - page 40

    Glossary NI PCI-5911 User Manual G- 2 ni.com A C coupled the passing of a signal through a filter network that remov es the DC component of t he signal ADC analog-to-digital con ver ter—an electronic de vice, often an integrated circuit, that con verts an an alog voltage to a digital number ADC resolution the resolution of the ADC, wh ich is meas ...

  • National Instruments NI PCI-5911 - page 41

    Glossary © National Instruments Corporat ion G-3 NI PCI-5911 User Manual clock hardware component that controls timing for reading from or writing to groups CMRR common-mode rejection ratio—a measure of an in strumen t’ s ability to reject interference from a common-m ode signal, usually expressed in decibels (dB) counter/timer a circuit that ...

  • National Instruments NI PCI-5911 - page 42

    Glossary NI PCI-5911 User Manual G- 4 ni.com E EEPR OM electrically erasable programmabl e read-only memory—R OM that can be erased with an electrical signal and reprogrammed equiv alent time sampling any method used to sample signals in such a way th at the apparent sampling rate is hig her than the r eal sampling rate even t the condition or st ...

  • National Instruments NI PCI-5911 - page 43

    Glossary © National Instruments Corporat ion G-5 NI PCI-5911 User Manual input impedance the measured resistance and capacitan ce between the input terminals of a circuit instrument driv er a set of high-lev el software functions t hat controls a specific plug-in D A Q board. Instrument driv ers are av ailabl e in se veral forms, ranging from a fu ...

  • National Instruments NI PCI-5911 - page 44

    Glossary NI PCI-5911 User Manual G- 6 ni.com N noise an undesirable electri cal signal—noise comes from external sources such as the A C power line, motors, generators, transform ers, fluorescent lights, soldering irons, CR T displays, computer s, electrical storms, welders, radio transmitters, and internal sources such as semicond uctors, resist ...

  • National Instruments NI PCI-5911 - page 45

    Glossary © National Instruments Corporat ion G-7 NI PCI-5911 User Manual pretriggering the technique used on a device to k eep a buf fer filled with data, so that when the trigger conditions are met , the sample includes the data leading up to the trigger condition PXI PCI eXtensions for Instrumentation. PXI is an open specification that builds of ...

  • National Instruments NI PCI-5911 - page 46

    Glossary NI PCI-5911 User Manual G- 8 ni.com sense in four -wire resistance the sense m easures the v oltage across the resistor being excited by the e xcitation current settling time the amount of time required for a voltage to reach its f inal v alue within specified limits source impedance a parameter of signal sources th at reflects current- dr ...

  • National Instruments NI PCI-5911 - page 47

    Glossary © National Instruments Corporat ion G-9 NI PCI-5911 User Manual V Vv o l t s V AC volts alternating current VDC volts direct current V error voltage error VI virtual instrument—(1) a combination of hardware and/or software elements, typically used with a PC, th at has the functionality of a classic stand-alone instru ment (2) a LabVIEW ...

  • National Instruments NI PCI-5911 - page 48

    © National Instruments Corporat ion I-1 NI PCI-5911 User Manual Index A AC coupling, 2-4 accuracy characteristics, A-3 acquisition multiple record, 2-11 Scope Soft Front Panel, 1-4 acquisition characteris tics specifications accuracy, A-3 common-mode characteristics, A-3 distortion, A-5 dynamic range, A-4 filtering, A-4 acquisition modes specifica ...

  • National Instruments NI PCI-5911 - page 49

    Index NI PCI-5911 User Manual I-2 ni.com E errors during acquisition, 2-8 example code, B-1 F filtering specifications, A-4 flexible resolu tion mode available sampling rates (table), 2-6 definition, 2-6 purpose and use, 2-6 frequently asked questions, B-1 G grounding considerations , 2-2 H hardware overview See also specifications acquisitio n sys ...

  • National Instruments NI PCI-5911 - page 50

    Index © National Instruments Corporat ion I-3 NI PCI-5911 User Manual Declaration of Conformity, B-1 professional services, B-1 system integration services, B-1 technical support, B-1 worldwide offices, B-2 NI 5911 See also hardware overview block diagram, 2-1 connectors BNC connector, 1-1 DIN connector, 1-1 location on front panel (figure), 1-2 S ...

  • National Instruments NI PCI-5911 - page 51

    Index NI PCI-5911 User Manual I-4 ni.com specifications acquisition characteristics accuracy, A-3 common-mode characteristics, A-3 distortion, A-5 dynamic range, A-4 filtering, A-4 acquisition modes, A-7 acquisitio n system, A-1 calibration, A-8 operating environment, A-7 physical, A-7 power requirements, A-7 storage environment, A-7 timebase syste ...

Производитель National Instruments Категория Network Card

Документы, которые мы получаем от производителя устройства National Instruments NI PCI-5911 мы можем разделить на несколько групп. Это в частности:
- технические чертежи National Instruments
- инструкции обслуживания NI PCI-5911
- паспорта изделия National Instruments
- информационные брошюры
- энергетические этикетки National Instruments NI PCI-5911
Все из них важны, однако самую важную информацию с точки зрения пользователя мы найдем в инструкции обслуживания National Instruments NI PCI-5911.

Группа документов, определяемая как инструкции обслуживания, делится также на более подробные типы, такие как: Инструкции монтажа National Instruments NI PCI-5911, инструкции обслуживания, короткие инструкции или инструкции пользователя National Instruments NI PCI-5911. В зависимости от потребностей, Вам необходимо поискать требуемый документ. На нашем сайте Вы можете просмотреть самую популярную инструкцию использования изделия National Instruments NI PCI-5911.

Похожие инструкции обслуживания

Полная инструкция обслуживания устройства National Instruments NI PCI-5911, как должна выглядеть?
Инструкция обслуживания, определяемая также как пособие пользователя, или просто "руководство" - это технический документ, цель которого заключается в использовании National Instruments NI PCI-5911 пользователями. Инструкции пишет, как правило технический писатель, языком, доступным для всех пользователей National Instruments NI PCI-5911.

Полная инструкция обслуживания National Instruments, должна заключать несколько основных элементов. Часть из них менее важная, как например: обложка / титульный лист или авторские страницы. Однако остальная часть, должна дать нам важную с точки зрения пользователя информацию.

1. Вступление и рекомендации, как пользоваться инструкцией National Instruments NI PCI-5911 - В начале каждой инструкции, необходимо найти указания, как пользоваться данным пособием. Здесь должна находится информация, касающаяся местонахождения содержания National Instruments NI PCI-5911, FAQ и самых распространенных проблем - то есть мест, которые чаще всего ищут пользователи в каждой инструкции обслуживания
2. Содержание - индекс всех советов, касающихся National Instruments NI PCI-5911, которое найдем в данном документе
3. Советы по использованию основных функций устройства National Instruments NI PCI-5911 - которые должны облегчить нам первые шаги во время использования National Instruments NI PCI-5911
4. Troubleshooting - систематизированный ряд действия, который поможет нам диагностировать а в дальнейшем очередность решения важнейших проблем National Instruments NI PCI-5911
5. FAQ - чаще всего задаваемые вопросы
6. Контактные данные Информация о том, где искать контактные данные производителя / сервисного центра National Instruments NI PCI-5911 в данной стране, если самостоятельно не получится решить проблему.

У вас вопрос, касающийся National Instruments NI PCI-5911?

Воспользуйтесь формуляром, находящимся ниже

Если с помощью найденной инструкции Вы не решили свою проблему с National Instruments NI PCI-5911, задайте вопрос, заполнив следующий формуляр. Если у какого то из пользователей была похожая проблема с National Instruments NI PCI-5911 со всей вероятностью он захочет поделиться методом ее решения.

Перепишите текст с картинки

Комментарии (0)