Инструкция обслуживания Akai AC-ZP112

25 страниц 0.56 mb
Скачать

Перейти на страницу of 25

Summary
  • Akai AC-ZP112 - page 1

    English ...

  • Akai AC-ZP112 - page 2

    T able of Co ntent s 1. Accessories ---------------------------------------- --------------------------------1 2. Introduction-------------------------------------------------------- ------------------2 3. Working Principle---------------------------------------------------------------- 3 4. T echnical S peci ficat ion----- ------------------------ ...

  • Akai AC-ZP112 - page 3

    A ccessories 1 inner air exhau st ad aptor ---------------------------------- ---------------------1 pc 2 air exhaust duct ---------------------------------------------- ------- -------------1 pc 3 adaptor ---------------------------------------------- --------------------------------1 pc 4 mounting duct -------------------------------------------- ...

  • Akai AC-ZP112 - page 4

    Introduction This mobile air cond itioner is a new generation air conditioner which is ideal for usin g in bedroom, study room, lobby , office, meeting room, warehouse attics, sports hall and othe r entertainment room . Its f lexibility characte ristic enab les easy ad justments to desirable room te mperature and humidity . Beside s, the built-in f ...

  • Akai AC-ZP112 - page 5

    Working Principle Refrigerant with low temperature a nd low pressure is compressed by the compressor to high temperature and high pressure vapour, then cools in the condenser (This is a forced air cooling process: room air passes condenser sur face, absorbs the refrigerant's heat in the condenser by heat exchange, then the room air warms up an ...

  • Akai AC-ZP112 - page 6

    T echnical Specific ation Unit specificat ions : Model AC-ZP112 Cooling Capacity ( Btu / h ) 12000 Dehumidifying Capacity ( L / d ay ) 24 Power consumption( W ) 1200 Flow Volume (m 3 / h ) 480 Sound pressure le vel dB(A) ≤55 Net Weight ( Kg ) 33 Body ( mm ) 738*446*377 Dimension Package ( mm ) 860*460*450 Refrigerant R407C Note: 1. The above co ...

  • Akai AC-ZP112 - page 7

    Structure 1. Control panel 2. Air out let 3. Handle 4. Caster 5. A ir filter 6. A ir inlet 7. Exhaust air outlet 8. Cord Hanger 9. Water stopper 9 7 8 5 6 10. I nner air exhaust ad aptor-connect with a ir exhaust duct (1 1) a nd exhaust air outlet (7) 1 1. Air exhaust du ct 12. Ada ptor 13. Mounting Duct 14. W i ndow kit 15. Wa ter plate 16. Remote ...

  • Akai AC-ZP112 - page 8

    Operation 1. Control panel AC-ZP1 12 2 . On/Off sw itch but ton Press On/Off button once the power is on, the unit will run at aut o mode. Press On/Off button while the unit is running, the unit stops, and timer setting is canceled , other in format ion (mode, set temp, and fan speed) remain in the machine . 3. Mode button Press Mode button, unit ...

  • Akai AC-ZP112 - page 9

    Operation Remote control : : : : Please point the controller trans mission section to the signal rece iver on the u nit panel. Indicator lights on the machine control panel can display AUTO, COOLING , F AN, DEHUMIDIFYING , SPEE D, TEMPERA TURE, T IMER etc information. O N / O F F S w i n g B u t t o n : I p r e s s s w i n g b u t t o n t o ...

  • Akai AC-ZP112 - page 10

    Operation Remote control (cooling mode) Setting temperature range 1 5 °C —31 °C ( 60-90 ° F ) . W hen t he room temperatu re sensor ’s temperature is higher than the set temperature, the compr essor starts to run. W hen t he room temperatu re sensor ’s temperature is lower than the set temperature, the compr essor stops and fan operate ...

  • Akai AC-ZP112 - page 11

    Operation Remote control (dehumidif y ing mode) Dehumidifying mo de: the compressor a nd lower fan are running and the up per fan is running at low speed. / ° ℃ F M O D E S W IN G + SPEED _ T I M E R 2 . P r e s s M O D E b u t t o n t o c h o o s e D E H U M I D I F Y I N G m ode. 1 . M o u n t b a t t e r i e s a n d p r e s s O N / O F F , t ...

  • Akai AC-ZP112 - page 12

    Battery Operation Please notice the ano de and cathode while mounting the batteries. We suggest using alkaline batteries. If the battery is to be replaced or thrown away , the batteries must be removed and dispose of in accordance with the current laws as it represents an environmental hazard. Remote control in serting the batteries 1. slide the co ...

  • Akai AC-ZP112 - page 13

    Operation Air exhaust duct The unit is called mob ile air conditioner , it is movable f rom one room to another convenient ly . Y o u can use the following method to exhaust the hot air . 1. exhaust heat f rom window (see figure A) Open window for a small angle to put bend mounting duct and fit it on the window . ≥ ≥ 5 0 c m ≥ 5 0 c m A ≥ 5 ...

  • Akai AC-ZP112 - page 14

    Operation W ind ow kit installation ( T a ke the ex amp le with three par ts of tracks. ) 1. Loose nut anti clockwise and u nscrew such as Fig 1. 2. adjust the w asher on board 1 at the sliding groove on board 2, and then insert t he fixation board 2 in the fix ation b oard 1 such as fig.2 3. adjust according to own window size an d fix nut on ...

  • Akai AC-ZP112 - page 15

    Operation W ind ow kit installation Y our window kit has b een designed to fit most standard “vertical” and “Horizontal” window applications. However , it may be nece ssary fo r y ou to improve/modify some a spects of the installation procedures for certain types of window . ( T a ke the example with three parts of tracks. ) Please refe ...

  • Akai AC-ZP112 - page 16

    Operation Air exhaust duct connection 1. air exhaust duct can be extended from 0.5 to 1.5 meters, the unit works more efficiently w hile the air exhaust duct is shorter . 2. please make su re the air exhaust duct is not distorted, or flo w back the hot air to in crease the temperature of the body . If so, the unit will stop running automatically 3. ...

  • Akai AC-ZP112 - page 17

    Maintenance T u rn of f the unit before cleaning, make sure all sockets are pulled out. Do not use chemica l solv ent (like b enzene) to clean the unit surface, or the unit surface will be easily sc ratched, damaged, even casing c ould be deformed . If the air filter is bl ocked with dust, the airflow volume will de crease. It is better to clean th ...

  • Akai AC-ZP112 - page 18

    Maintenance Drainage: W hen un it running in cooling mode, mostly the water can be d rained out through the exhausted hose, however , if the en vironment is too humid, condensed w ater can n ot completely be drained o ut by th is way . In this ca se, we need to drain the water . W hile water tray is full, error code “E 4” will appear in display ...

  • Akai AC-ZP112 - page 19

    Maintenance B . Connect drainage 1. disconnect dra inage knob and the rubber plug; 2. connect supplied dr ainage p ipe to drainage hole, water will flow out automatically; 3. if you want to extend d rainage pipe, you can use 18mm(diameter) plastic pipe and connect with the drainage pipe. R u b b er P l u g E x t en d D r a i n a ge P i p e ( D i ...

  • Akai AC-ZP112 - page 20

    T rouble shooting Before asking fo r rep air , plea se check: PROBLEMS CAUSES SUGGEST SOLUTIONS The unit does not work Power supply fault: 1. Not plug in; 2. Bad plug or socke t; 3. Fuse b roken or w ire broken; 1. Plug in correct ly; 2. Change the plu g or t he so cket; 3. Send th e unit to se rvice ce nter to change t he fuse ;( fuse: 3.15A 250V ...

  • Akai AC-ZP112 - page 21

    Safety Caution s 1. Do not use unit ne ar gas appliance, fires or in the vicinity of flammab le liquids. 2. Do not let ch ildren put their fingers into the air outlet to avoid danger. 3. Do not incline the unit m ore than 35° while moving the unit. 4. Do not beat o r ex trude unit to prevent unit broken, do not vibrate the unit. 5. Keep the unit t ...

  • Akai AC-ZP112 - page 22

    Special Guide Line 1. Do not incline the unit mo re than 5° degree, if so, please turn off po wer supply immediately and a sk for ad vice from your local dealer. 2. Do not spray insecticide o r other chemicals to avoid deformation of plastic case. 3. The unit, due to its moving fe ature, it can be m oved f rom room to room and it is different from ...

  • Akai AC-ZP112 - page 23

    A fter Sale Service W hen there are problems with the unit, please stop using it a nd ask for help f rom your local dealer or se rv ice center. Maintenance: After running for se ver al seasons, there wi ll be dust covered in the air filter. This will reduce the airflow volume a nd influence the cooling efficiency of the unit. Please clean the air f ...

  • Akai AC-ZP112 - page 24

    Electric Circuit Dra w ing -22- ...

  • Akai AC-ZP112 - page 25

    Disposal of Used Elec trical & E lectronic Equipment The meaning of the s y m bol on the pro duct, its access ory or packaging indicates that this product shal l not be treated as household waste. Pleas e, dispose of th is equipmen t at your applicable col lection point f or the rec y c ling of electrical & electr onic equipm ents waste. In ...

Производитель Akai Категория Air Conditioner

Документы, которые мы получаем от производителя устройства Akai AC-ZP112 мы можем разделить на несколько групп. Это в частности:
- технические чертежи Akai
- инструкции обслуживания AC-ZP112
- паспорта изделия Akai
- информационные брошюры
- энергетические этикетки Akai AC-ZP112
Все из них важны, однако самую важную информацию с точки зрения пользователя мы найдем в инструкции обслуживания Akai AC-ZP112.

Группа документов, определяемая как инструкции обслуживания, делится также на более подробные типы, такие как: Инструкции монтажа Akai AC-ZP112, инструкции обслуживания, короткие инструкции или инструкции пользователя Akai AC-ZP112. В зависимости от потребностей, Вам необходимо поискать требуемый документ. На нашем сайте Вы можете просмотреть самую популярную инструкцию использования изделия Akai AC-ZP112.

Похожие инструкции обслуживания

Полная инструкция обслуживания устройства Akai AC-ZP112, как должна выглядеть?
Инструкция обслуживания, определяемая также как пособие пользователя, или просто "руководство" - это технический документ, цель которого заключается в использовании Akai AC-ZP112 пользователями. Инструкции пишет, как правило технический писатель, языком, доступным для всех пользователей Akai AC-ZP112.

Полная инструкция обслуживания Akai, должна заключать несколько основных элементов. Часть из них менее важная, как например: обложка / титульный лист или авторские страницы. Однако остальная часть, должна дать нам важную с точки зрения пользователя информацию.

1. Вступление и рекомендации, как пользоваться инструкцией Akai AC-ZP112 - В начале каждой инструкции, необходимо найти указания, как пользоваться данным пособием. Здесь должна находится информация, касающаяся местонахождения содержания Akai AC-ZP112, FAQ и самых распространенных проблем - то есть мест, которые чаще всего ищут пользователи в каждой инструкции обслуживания
2. Содержание - индекс всех советов, касающихся Akai AC-ZP112, которое найдем в данном документе
3. Советы по использованию основных функций устройства Akai AC-ZP112 - которые должны облегчить нам первые шаги во время использования Akai AC-ZP112
4. Troubleshooting - систематизированный ряд действия, который поможет нам диагностировать а в дальнейшем очередность решения важнейших проблем Akai AC-ZP112
5. FAQ - чаще всего задаваемые вопросы
6. Контактные данные Информация о том, где искать контактные данные производителя / сервисного центра Akai AC-ZP112 в данной стране, если самостоятельно не получится решить проблему.

У вас вопрос, касающийся Akai AC-ZP112?

Воспользуйтесь формуляром, находящимся ниже

Если с помощью найденной инструкции Вы не решили свою проблему с Akai AC-ZP112, задайте вопрос, заполнив следующий формуляр. Если у какого то из пользователей была похожая проблема с Akai AC-ZP112 со всей вероятностью он захочет поделиться методом ее решения.

Перепишите текст с картинки