Инструкция обслуживания Fujitsu M5000-CL11-12-PI01

38 страниц 1.15 mb
Скачать

Перейти на страницу of 38

Summary
  • Fujitsu M5000-CL11-12-PI01 - page 1

    Issue June 01, 2008 Product SPARC ® Enterprise M5000 SPARC ® Enterprise M5000 Server Pages 38 SPARC ® Enterprise M5000 Configuration Diagram  New products: M5000-GR20, M5000-CL09-PI01, M 5000-CL10-PI01, M5000-CL11- 12-PI01  Withdrawn products :  Some minor corrections: Chapter “Mounting additional Memory with different si zes” Syste ...

  • Fujitsu M5000-CL11-12-PI01 - page 2

    Product Facts ⏐ Issue: June 01, 2008 ⏐ Product: SPARC ® Enterp rise M5000 Page 2 / 38 Contents Recommended 19"- rac k PRIMECENTER 2 with 1100 mm dept h 3 Overview M4000 and M5000 4 System Architecture 5 Product Overv iew SPARC ® Enterprise M5000 6 Features 6 M5000 Server Product ID List 9 M5000 COD (Capacity on Demand) Server Product ID ...

  • Fujitsu M5000-CL11-12-PI01 - page 3

    Product Facts ⏐ Issue: June 01, 2008 ⏐ Product: SPARC ® Enterp rise M5000 Page 3 / 38 Recommended 19"- rack PRIMECENTER 2 with 1100 mm depth 24 HU height 38 HU height 46 HU height + 2 x 2 HU vertical + 3 x 2 HU vertical + 4 x 2 HU vertical S26361-K826-V212 S263 61-K826-V213 S26361-K 826-V214  SPARC ® Enterprise M5000 servers can be mo ...

  • Fujitsu M5000-CL11-12-PI01 - page 4

    Product Facts ⏐ Issue: June 01, 2008 ⏐ Product: SPARC ® Enterp rise M5000 Page 4 / 38 Overview M4000 and M5000 SPARC ® Enterprise M4000 SPARC ® Enterprise M5000 Enclosure Rack 6U Rack 10U CPU / Processor Chips (multi-core, multi-thread (VMT)) 4 x 2.15GHz SPARC ® 64VI (2 per module) 8 x 2.15GHz SPARC ® 64VI (2 per module) Cores / Threads pe ...

  • Fujitsu M5000-CL11-12-PI01 - page 5

    Product Facts ⏐ Issue: June 01, 2008 ⏐ Product: SPARC ® Enterp rise M5000 Page 5 / 38 System Architecture PRIM ECENTER 2 Rac k deep 1100mm 24U, 38U, 46U SPARC Enterprise M 5000 Basic Confi g up to 8x CPU (up to 16 c ore) / 256 GB M EM / 4x Hard dis k / 2x PCI- X and 8 x PCI- expr es s slot 10U Up to 8 CPU, 4 Modul e (SPARC64 VI). Up to 16 core ...

  • Fujitsu M5000-CL11-12-PI01 - page 6

    Product Facts ⏐ Issue: June 01, 2008 ⏐ Product: SPARC ® Enterp rise M5000 Page 6 / 38 Product Overview SPARC ® Enterprise M5000 SPARC ® ENTERPRISE M5000 is a midrange server deve loped usi ng the expertise of Fujitsu and Sun Micros ystems. It has been designed to be the best choice in mission-cr itical computing solutions. High scalability c ...

  • Fujitsu M5000-CL11-12-PI01 - page 7

    Product Facts ⏐ Issue: June 01, 2008 ⏐ Product: SPARC ® Enterp rise M5000 Page 7 / 38 4. Very flex ible partitioning fun ctions are prov ided. • Multiple independent s ystems can be built on a single server called partition s or domains. • Each partition can individu all y be configured. • Up to four partitions are supported. • The mot ...

  • Fujitsu M5000-CL11-12-PI01 - page 8

    Product Facts ⏐ Issue: June 01, 2008 ⏐ Product: SPARC ® Enterp rise M5000 Page 8 / 38 9. Configuration Diagram of the Main Unit * Areas indicated in blue sho w com po nents belonging to the bas e units; those indicat ed in red show options (purchase d separately, but see also b ase unit description). 10. Hardw are for M5000 • Motherboard The ...

  • Fujitsu M5000-CL11-12-PI01 - page 9

    Product Facts ⏐ Issue: June 01, 2008 ⏐ Product: SPARC ® Enterp rise M5000 Page 9 / 38 M5000 Server Product ID List PART NUMBER LONG DESCRIPTION SHORT DESCRIPTION M5000 family: SEFPAAA1S Fujitsu-Siemens Computers SPARC ® Enterprise M5000 server. Includes M5000 system, 2x 2.1GHz CPUs (1 2x 2.1GHz CPU Modules), 16GB system memory (2 ea. 8GB memo ...

  • Fujitsu M5000-CL11-12-PI01 - page 10

    Product Facts ⏐ Issue: June 01, 2008 ⏐ Product: SPARC ® Enterp rise M5000 Page 10 / 38 M5000 COD (Capacity on Demand) Server Product ID List PART NUMBER LONG DESCRIPTION SHORT DESCRIPTION M5000family: SEFRCDB1S FSC SPARC Enterprise M5000 COD (Capacity On Demand) server. Includes 8x 2.15GHz CPUs (4 CPU boards with 2 x CPUs each, 5MB on- chip L2 ...

  • Fujitsu M5000-CL11-12-PI01 - page 11

    Product Facts ⏐ Issue: June 01, 2008 ⏐ Product: SPARC ® Enterp rise M5000 Page 11 / 38 M5000 Power Cords for Rack internal use Product ID List Attention: For each PSU a Power Cord must be ordered for Rack inter nal connection (thickly marked in table below) to the Socket strip! Note: M5000 requires 4x 16A power cords, each I/O-Box requires 2x ...

  • Fujitsu M5000-CL11-12-PI01 - page 12

    Product Facts ⏐ Issue: June 01, 2008 ⏐ Product: SPARC ® Enterp rise M5000 Page 12 / 38 Power supply unit and p ower supply connections SPARC ® ENTERPRISE M5000 has 2+2 redundant po wer supply units (four in total). Connect the power supply units as follows. Single Pow er Feed Dual Power Feed Power supply unit #0 Power supply unit #1 Power sup ...

  • Fujitsu M5000-CL11-12-PI01 - page 13

    Product Facts ⏐ Issue: June 01, 2008 ⏐ Product: SPARC ® Enterp rise M5000 Page 13 / 38 M5000 PCI Card Product ID List Ethernet Controller Overv ie w Ord e r Numbers options: PCI Bus type for Factory Integration or X-option Description Max wit hi n a System Max in an I/O-boat Supported in I/O-Box X7281A-2 X-option Ye s 7281A-2 PCI-e Fact.- Inte ...

  • Fujitsu M5000-CL11-12-PI01 - page 14

    Product Facts ⏐ Issue: June 01, 2008 ⏐ Product: SPARC ® Enterp rise M5000 Page 14 / 38 Fibre Chann el Ho st Bus Adapters Overv ie w Ord e r Numbers options: PCI Bus type: for Factory Integration or X-option Description Max wit hi n a System Max in an I/O-boat Supported in I/O-Box SG-XPCIE2FC-QF4 X-option Yes SG-PCIE2FC-QF4 PCI-e Fact.- Integra ...

  • Fujitsu M5000-CL11-12-PI01 - page 15

    Product Facts ⏐ Issue: June 01, 2008 ⏐ Product: SPARC ® Enterp rise M5000 Page 15 / 38 Console Connection For APL a personal computer (PC) or workstation is required fo r system control and maintenance work. T his console m ust be setup prior to installation of APL. The XSCF is accessed using this console. The console ports of each partition a ...

  • Fujitsu M5000-CL11-12-PI01 - page 16

    Product Facts ⏐ Issue: June 01, 2008 ⏐ Product: SPARC ® Enterp rise M5000 Page 16 / 38 Console connection e xample (Field engine er conn ects temporarily a PC via LAN (sho wn as blue line) or RS-232C (shown as dotted line) as required to pro vide maintenance) Note: For the HUB in the picture our LAN Switch D:GP70F-AL21 can be o rdered. Console ...

  • Fujitsu M5000-CL11-12-PI01 - page 17

    Product Facts ⏐ Issue: June 01, 2008 ⏐ Product: SPARC ® Enterp rise M5000 Page 17 / 38 Specifications for the PC (or the workstation, etc.) Description Remarks CPU Pentium3 1 GHz or greater SPARC ® Equivalent CPUs i.e. AMD are suitable. Memory 512 MB or greater OS Windows XP Windows2000 RedHat Linux Solaris One of the OS listed on the left is ...

  • Fujitsu M5000-CL11-12-PI01 - page 18

    Product Facts ⏐ Issue: June 01, 2008 ⏐ Product: SPARC ® Enterp rise M5000 Page 18 / 38 Partitioning SPARC ® ENTERPRISE M5000 supports partitioning in which a single server can be divi ded i nto multiple independent s ystems. • Partitioning creates multiple independent s y stems which are called partitions or domai ns. • The basic hardware ...

  • Fujitsu M5000-CL11-12-PI01 - page 19

    Product Facts ⏐ Issue: June 01, 2008 ⏐ Product: SPARC ® Enterp rise M5000 Page 19 / 38 If only one partition is configured with both PSBs in Uni-XSB mode but no CPU- an d MEM-modul es are mounted on PSB#1, then HDDs and PCI slot s on the additional I/O board cann ot be used (Areas shaded black in t he figure below are not equipped with CPU- an ...

  • Fujitsu M5000-CL11-12-PI01 - page 20

    Product Facts ⏐ Issue: June 01, 2008 ⏐ Product: SPARC ® Enterp rise M5000 Page 20 / 38 2) Quad XSB Because Quad-XSB allo ws to configure several partitions in units of individual CP U chips (two cores) it is the optimized way to create small partitions. Quad-XSB is equivalent to the XSB definition for PRIMEPOWER. Division Type: Quad- XSB PSB ( ...

  • Fujitsu M5000-CL11-12-PI01 - page 21

    Product Facts ⏐ Issue: June 01, 2008 ⏐ Product: SPARC ® Enterp rise M5000 Page 21 / 38 Example for four partitions configured with two XSBs. ...

  • Fujitsu M5000-CL11-12-PI01 - page 22

    Product Facts ⏐ Issue: June 01, 2008 ⏐ Product: SPARC ® Enterp rise M5000 Page 22 / 38 3) Combination of Uni-XSB and Quad-XSB PSBs divided into Quad-XSBs can be mixed together with Uni-XSB to configure a common partiti on. There is no difference in settings and conditions for partitions config ured with Uni- XSB only or Quad-XSB only. T his op ...

  • Fujitsu M5000-CL11-12-PI01 - page 23

    Product Facts ⏐ Issue: June 01, 2008 ⏐ Product: SPARC ® Enterp rise M5000 Page 23 / 38 CPU Module Product Overv iew SPARC ® ENTERPRISE M5000 servers use SPARC ® 64 VI processors, which are multi-core/multi-threa ding CPUs. Each module contains two CPU chips (4 cores). Up to four CPU modules can be installed in SPARC ® ENTERPRISE M5000. Appe ...

  • Fujitsu M5000-CL11-12-PI01 - page 24

    Product Facts ⏐ Issue: June 01, 2008 ⏐ Product: SPARC ® Enterp rise M5000 Page 24 / 38 Specifications Items Specifications Remarks Type SPARC ® 64 VI Frequency 2.15 GHz Primary cache Instructions: 128 KB data: 128 KB per core Secondary cache Both the instruction and data: 5 MB per CPU (2 cores) CPU Expansion unit 1 CPU module (2 CPU chips, 4 ...

  • Fujitsu M5000-CL11-12-PI01 - page 25

    Product Facts ⏐ Issue: June 01, 2008 ⏐ Product: SPARC ® Enterp rise M5000 Page 25 / 38 Additional Memory Module Product Overv iew SPARC ® ENTERPRISE M5000 memory module is an e xpa nsion memory device consisting of memor y DIMMs and a memory controller equipped o n a board that can be plugge d to the mother boar d. There are 8 GB, 16 GB, and ...

  • Fujitsu M5000-CL11-12-PI01 - page 26

    Product Facts ⏐ Issue: June 01, 2008 ⏐ Product: SPARC ® Enterp rise M5000 Page 26 / 38 Notes on Memory ordering: • Two sets of memory modules with the same size (16 DIMMs) must be mounted on a physical s ystem board as a minimum. 8 DIMMS are always hand led as one set. • When adding memor y, two sets of memory modules with the same size mu ...

  • Fujitsu M5000-CL11-12-PI01 - page 27

    Product Facts ⏐ Issue: June 01, 2008 ⏐ Product: SPARC ® Enterp rise M5000 Page 27 / 38 Mounting additional Memory with different sizes MEM in SPARC ® Enterprise M5000 is organized on each SB separate ly in two groups: • Max. 16 DIMMs mounted in MEM#xA slot s at SB#0 defined as Group A of SB#0. • Max. 16 DIMMs mounted in MEM#xB slot s at S ...

  • Fujitsu M5000-CL11-12-PI01 - page 28

    Product Facts ⏐ Issue: June 01, 2008 ⏐ Product: SPARC ® Enterp rise M5000 Page 28 / 38 Mounting Conditions for Memory with differ e nt si zes Condition 1: To mix different DIMM types on a certain SB see chapter “Mounting additi onal Memory with different sizes”. Condition 2: Two sets of memory modules with the same size (16 DI MMs) must be ...

  • Fujitsu M5000-CL11-12-PI01 - page 29

    Product Facts ⏐ Issue: June 01, 2008 ⏐ Product: SPARC ® Enterp rise M5000 Page 29 / 38 Memory Interleaving Memory interleaving is a technique that div ides main memory into several blocks (WAYs) and accesses each WAY independently and i n parallel to enable e ffective access to the contig uo us area. The size of one WAY is 64 bytes, which is t ...

  • Fujitsu M5000-CL11-12-PI01 - page 30

    Product Facts ⏐ Issue: June 01, 2008 ⏐ Product: SPARC ® Enterp rise M5000 Page 30 / 38 I/O Board (also called I/O tray or I/O Unit (IOU)) Product Overv iew The SPARC ® ENTERPRISE M5000 basic configuration cont ains one I/O board. A second I/O board can be added to SPARC ® ENTERPRISE M5000. Appeara nce Features • The I/O board provides four ...

  • Fujitsu M5000-CL11-12-PI01 - page 31

    Product Facts ⏐ Issue: June 01, 2008 ⏐ Product: SPARC ® Enterp rise M5000 Page 31 / 38 I/O-BOX Product Overv iew The External I/O Expansion Unit (hereafte r referred to as I/O Box) is a rack-mount able expansion unit used to expand the server’s I/O connectivity with up to 12 PCI Express or PCI-X slots. Each I/O-box can contain two External I ...

  • Fujitsu M5000-CL11-12-PI01 - page 32

    Product Facts ⏐ Issue: June 01, 2008 ⏐ Product: SPARC ® Enterp rise M5000 Page 32 / 38 PCI Bus: indicates the types of I/O boat. LINK0: indicates slots wher e Link Ca rds, separately purchased PCI cards for connecting the server and the I/O Box, are mounted. No. of Lanes: indicates the width of PCI Express slot lane and shows eight lanes are s ...

  • Fujitsu M5000-CL11-12-PI01 - page 33

    Product Facts ⏐ Issue: June 01, 2008 ⏐ Product: SPARC ® Enterp rise M5000 Page 33 / 38 M5000 external I/O-Box Product ID List Marketing P/N Option Description Comments SENX8BE1S PCI-Express External I/O Expansion Un it, w. 2x PSUs, w 1 PCI-E Boat, ROHS-6 If “Factory integra tion” will be accomplished or not depend s on order sequencing! FS ...

  • Fujitsu M5000-CL11-12-PI01 - page 34

    Product Facts ⏐ Issue: June 01, 2008 ⏐ Product: SPARC ® Enterp rise M5000 Page 34 / 38 External storage units for M5000 External storage units for HDDs or MTC drives (differential SCSI) DN413 disk node for high performan ce HDD Overall view disk nodes (new generation) Disk node DN413 Drive interface U320 SCSI Wide (LVD) Node interface U320 SCS ...

  • Fujitsu M5000-CL11-12-PI01 - page 35

    Product Facts ⏐ Issue: June 01, 2008 ⏐ Product: SPARC ® Enterp rise M5000 Page 35 / 38 Hard Disk drives for DN413* D:GPDS2 - FP81 Hard disk 73GB 15kRpm 73 GByte 15,000rpm, Ultra SCSI LVD320 Fast drives with short access time D:GPDS2-FP84 Hard disk U320 10k 146 GB 146 GByte 10,000rpm, Ultra SCSI LVD32 0 D:GPDS2-FP85 Hard disk U320 10k 300 GB 30 ...

  • Fujitsu M5000-CL11-12-PI01 - page 36

    Product Facts ⏐ Issue: June 01, 2008 ⏐ Product: SPARC ® Enterp rise M5000 Page 36 / 38 BG57 for accessible devi ces Order number for BG57 D:EPRCK-BG57 19" Rack Bo x f. change able Peripheral 2channel U160 Rack-mountable box, 3 HU, 4 bays (1.6” hi gh)  2 SCSI strings (2 bays each) as standard  4 SCSI strings (1 bay each) with optio ...

  • Fujitsu M5000-CL11-12-PI01 - page 37

    Product Facts ⏐ Issue: June 01, 2008 ⏐ Product: SPARC ® Enterp rise M5000 Page 37 / 38 Cables for connecting BG57 boxes to SCSI con tro ller (u p to 80MByte/s, device dependent) D:KB235-M3 SCSI cable 3m (68pin UHD and 68pin A mplimite) D:KB235-M5 SCSI cable 5m (68pin UHD and 68pin A mplimite) D:KB235-M8 SCSI cable 8m (68pin UHD and 68pin A mpl ...

  • Fujitsu M5000-CL11-12-PI01 - page 38

    Product Facts ⏐ Issue: June 01, 2008 ⏐ Product: SPARC ® Enterp rise M5000 Page 38 / 38 Link: Open page: http://partners.fujitsu-siemens.com/com/pr oducts/servers/consulti ng/Pages/default.aspx http://extranet3.fujitsu-siemens.com/products /consulting/prof_services/open_connectivity Information about UPS (Unint erruptable Power Supplys): UPSes ...

Производитель Fujitsu Категория Computer Hardware

Документы, которые мы получаем от производителя устройства Fujitsu M5000-CL11-12-PI01 мы можем разделить на несколько групп. Это в частности:
- технические чертежи Fujitsu
- инструкции обслуживания M5000-CL11-12-PI01
- паспорта изделия Fujitsu
- информационные брошюры
- энергетические этикетки Fujitsu M5000-CL11-12-PI01
Все из них важны, однако самую важную информацию с точки зрения пользователя мы найдем в инструкции обслуживания Fujitsu M5000-CL11-12-PI01.

Группа документов, определяемая как инструкции обслуживания, делится также на более подробные типы, такие как: Инструкции монтажа Fujitsu M5000-CL11-12-PI01, инструкции обслуживания, короткие инструкции или инструкции пользователя Fujitsu M5000-CL11-12-PI01. В зависимости от потребностей, Вам необходимо поискать требуемый документ. На нашем сайте Вы можете просмотреть самую популярную инструкцию использования изделия Fujitsu M5000-CL11-12-PI01.

Похожие инструкции обслуживания

Полная инструкция обслуживания устройства Fujitsu M5000-CL11-12-PI01, как должна выглядеть?
Инструкция обслуживания, определяемая также как пособие пользователя, или просто "руководство" - это технический документ, цель которого заключается в использовании Fujitsu M5000-CL11-12-PI01 пользователями. Инструкции пишет, как правило технический писатель, языком, доступным для всех пользователей Fujitsu M5000-CL11-12-PI01.

Полная инструкция обслуживания Fujitsu, должна заключать несколько основных элементов. Часть из них менее важная, как например: обложка / титульный лист или авторские страницы. Однако остальная часть, должна дать нам важную с точки зрения пользователя информацию.

1. Вступление и рекомендации, как пользоваться инструкцией Fujitsu M5000-CL11-12-PI01 - В начале каждой инструкции, необходимо найти указания, как пользоваться данным пособием. Здесь должна находится информация, касающаяся местонахождения содержания Fujitsu M5000-CL11-12-PI01, FAQ и самых распространенных проблем - то есть мест, которые чаще всего ищут пользователи в каждой инструкции обслуживания
2. Содержание - индекс всех советов, касающихся Fujitsu M5000-CL11-12-PI01, которое найдем в данном документе
3. Советы по использованию основных функций устройства Fujitsu M5000-CL11-12-PI01 - которые должны облегчить нам первые шаги во время использования Fujitsu M5000-CL11-12-PI01
4. Troubleshooting - систематизированный ряд действия, который поможет нам диагностировать а в дальнейшем очередность решения важнейших проблем Fujitsu M5000-CL11-12-PI01
5. FAQ - чаще всего задаваемые вопросы
6. Контактные данные Информация о том, где искать контактные данные производителя / сервисного центра Fujitsu M5000-CL11-12-PI01 в данной стране, если самостоятельно не получится решить проблему.

У вас вопрос, касающийся Fujitsu M5000-CL11-12-PI01?

Воспользуйтесь формуляром, находящимся ниже

Если с помощью найденной инструкции Вы не решили свою проблему с Fujitsu M5000-CL11-12-PI01, задайте вопрос, заполнив следующий формуляр. Если у какого то из пользователей была похожая проблема с Fujitsu M5000-CL11-12-PI01 со всей вероятностью он захочет поделиться методом ее решения.

Перепишите текст с картинки

Комментарии (0)