Инструкция обслуживания Auto Page RF-502

18 страниц 0.05 mb
Скачать

Перейти на страницу of 18

Summary
  • Auto Page RF-502 - page 1

    RF - 502 OPERATION INSTRUCTIONS ...

  • Auto Page RF-502 - page 2

    Congratulations on your purchase of the RF - 502 vehicle security system. AutoPage, Inc. is one of the companies with the longest history and experience in vehicle security in the United States and a wh olly owned subsidiary of Iwata Electric Co., of Tokyo, Japan. Iwata has been an industry leader for 40 years, establishing a reputation for ingenui ...

  • Auto Page RF-502 - page 3

    RF - 502 1 RF - 502 OPERATION I NSTRUCTIONS A. REMOTE CONTROL TRANSMITTER OPERATION The new remote control transmitter (XT - 54) included with the RF - 502 offers the code rolling feature which will prevent illegal use of a code - grabber with an attempt to record the code of your transmitter. 1. ARM/DISARM TO ARM THE RF - 502 Press the ON/OFF butt ...

  • Auto Page RF-502 - page 4

    RF - 502 2 particular operation. The sequence must be repeated each time if it is desired to cancel the arm/disarm chirp sound. 3. PANIC FUNCTION The RF - 502 remote control may be used as a remote panic switch to trigger the siren in cases of emergency. To activate the PANIC FUNCTION press and hold the ON/OFF button on the remote transmitter for a ...

  • Auto Page RF-502 - page 5

    RF - 502 3 To replace the battery, carefully remove the case screw located at the end of the remote where the key ring attaches to the case. Use a small blade Phillips screwdriver. B efore removing the battery note the direction of its terminals. Install the new battery exactly the same, using caution so as not to bend, or otherwise damage the batt ...

  • Auto Page RF-502 - page 6

    RF - 502 4 D. VALET/OVERRIDE SWITCH NOTE : Both VALET and OVERRIDE functions are performed from the same switch. 1. OVERRIDE FUNCTION The OVERRIDE FUNCTION may be used if the RF - 502 remote is lost or inoperative. To operate the OVERRIDE FUNCTION, enter the vehicle (siren will sound); switch the vehicle ignition to ON. Move the VALET/OVERRIDE swit ...

  • Auto Page RF-502 - page 7

    RF - 502 5 E. PASSIVE/MANUAL ARMING OPERATION (Optional at installation) Passive/Manual operations can be selectable if an optional toggle switch is installed. Consult your installing dealer. 1. PASSIVE ARMING If you choose the PASSIVE (aut omatic) mode, the system must be operated as below. 1. Switch OFF vehicle ignition, exit vehicle, and be sure ...

  • Auto Page RF-502 - page 8

    RF - 502 6 Approach the vehicle and press the ON/OFF remote transmitter button. The siren will chirp 2 times and the lights will flash to indicate the RF - 502 is disarmed. G. AUTOMATIC RE - ARMING The RF - 502 is equipped with an automatic re - arming circuit that will return the alarm to a fully armed state if a door is not opened within 60 secon ...

  • Auto Page RF-502 - page 9

    RF - 502 7 1. Open any door or other protected opening. The siren will sound instantly, and the lights will flash. 2. If the pre - warning feature is activated, the RF - 502’s SIS - 5 impact sensor will respond to a light shock with a chirp sound, and trigger the alarm when a heavier shock is detected. (Please refer to A - 4 for details). 3. If o ...

  • Auto Page RF-502 - page 10

    RF - 502 8 4. Turn the igniti on switch "ON/OFF", "ON/OFF". The siren will chirp one (1) time. You are now in the programming mode. 5. Press the ON/OFF button on one of the remote transmitters until the alarm siren responds with a confirming chirp. The first transmitter is now programmed. Within five (5) seconds , press the ON/O ...

  • Auto Page RF-502 - page 11

    RF - 502 9 Enter the programming mode on vehicle #1 and push the ON/OFF button on the tran smitter for Vehicle #1. The alarm siren will respond with a confirming chirp. Within five (5) seconds , push the AUX button on the transmitter for Vehicle #2. The alarm siren will respond with a confirming chirp. Both transmitters are now programmed to Vehicl ...

  • Auto Page RF-502 - page 12

    RF - 502 10 AUTOPAGE ALARM ACCESSORIES AP - 4000DX Paging System Vehicle secu rity paging was originated by AutoPage over 18 years ago. The AP4000DX is our latest version providing a full four watts of output power to signal a handsome belt - clip paging receiver indicating your RF - 502 has been triggered, even if you cannot hear the siren. RS - 3 ...

  • Auto Page RF-502 - page 13

    RF - 502 11 sensors, the SIS - 10 has a LED and potentiometer for easy sensitivity adjustment. MSEN - KIT The MSEN - KIT includes two pre - wired Micro Resonance Sensors and a special triggering amplifier. These special sensors are designed to be mounted within the vehicle door or on the door post near the latching mechanism that keeps the door clo ...

  • Auto Page RF-502 - page 14

    12 LIMITED LIFETIME WARRANTY PROVISIONS (U.S. and Continental U.S. Only) 1. AutoPage, Inc. WARRANTS that this new unit has been thoroughly inspected and tested at the factory prior to delivery. Your AutoPage equipment is guaranteed for "life" to the original purchaser/user of the equipment under the following conditions: If the product pr ...

  • Auto Page RF-502 - page 15

    RF - 502 13 7 AutoPage shall not be liable, under the foregoi ng WARRANTIES or otherwise, for: Any personal injury of any kind to the purchaser, its employees or agents or anyone else whomsoever resulting directly or indirectly from the use or presence of the equipment or parts; Consequential damages of any kind; Any inability of the purchaser to u ...

  • Auto Page RF-502 - page 16

    This WARRANTY CARD is for your record. However, AutoPage reserves the right to request you to submit this WARRANTY CARD which must have complete information to receive warranty service. Please keep this card in a secured place. AUTOPAGE WARRANTY SERVICE CARD Model RF - 502 Serial#______________________________ CUSTOMER TO COMPLETE DEALER TO COMPLET ...

  • Auto Page RF-502 - page 17

    13 DATE SERVICE COMPLETED ...

  • Auto Page RF-502 - page 18

    1815 W. 205th St. #101 Torrance, CA 90501 310 - 618 - 2002 ...

Производитель Auto Page Категория Automobile Alarm

Документы, которые мы получаем от производителя устройства Auto Page RF-502 мы можем разделить на несколько групп. Это в частности:
- технические чертежи Auto Page
- инструкции обслуживания RF-502
- паспорта изделия Auto Page
- информационные брошюры
- энергетические этикетки Auto Page RF-502
Все из них важны, однако самую важную информацию с точки зрения пользователя мы найдем в инструкции обслуживания Auto Page RF-502.

Группа документов, определяемая как инструкции обслуживания, делится также на более подробные типы, такие как: Инструкции монтажа Auto Page RF-502, инструкции обслуживания, короткие инструкции или инструкции пользователя Auto Page RF-502. В зависимости от потребностей, Вам необходимо поискать требуемый документ. На нашем сайте Вы можете просмотреть самую популярную инструкцию использования изделия Auto Page RF-502.

Похожие инструкции обслуживания

Полная инструкция обслуживания устройства Auto Page RF-502, как должна выглядеть?
Инструкция обслуживания, определяемая также как пособие пользователя, или просто "руководство" - это технический документ, цель которого заключается в использовании Auto Page RF-502 пользователями. Инструкции пишет, как правило технический писатель, языком, доступным для всех пользователей Auto Page RF-502.

Полная инструкция обслуживания Auto Page, должна заключать несколько основных элементов. Часть из них менее важная, как например: обложка / титульный лист или авторские страницы. Однако остальная часть, должна дать нам важную с точки зрения пользователя информацию.

1. Вступление и рекомендации, как пользоваться инструкцией Auto Page RF-502 - В начале каждой инструкции, необходимо найти указания, как пользоваться данным пособием. Здесь должна находится информация, касающаяся местонахождения содержания Auto Page RF-502, FAQ и самых распространенных проблем - то есть мест, которые чаще всего ищут пользователи в каждой инструкции обслуживания
2. Содержание - индекс всех советов, касающихся Auto Page RF-502, которое найдем в данном документе
3. Советы по использованию основных функций устройства Auto Page RF-502 - которые должны облегчить нам первые шаги во время использования Auto Page RF-502
4. Troubleshooting - систематизированный ряд действия, который поможет нам диагностировать а в дальнейшем очередность решения важнейших проблем Auto Page RF-502
5. FAQ - чаще всего задаваемые вопросы
6. Контактные данные Информация о том, где искать контактные данные производителя / сервисного центра Auto Page RF-502 в данной стране, если самостоятельно не получится решить проблему.

У вас вопрос, касающийся Auto Page RF-502?

Воспользуйтесь формуляром, находящимся ниже

Если с помощью найденной инструкции Вы не решили свою проблему с Auto Page RF-502, задайте вопрос, заполнив следующий формуляр. Если у какого то из пользователей была похожая проблема с Auto Page RF-502 со всей вероятностью он захочет поделиться методом ее решения.

Перепишите текст с картинки

Комментарии (1)

Gerardo martin

Hola buenas tardes quería saber cómo puedo subir la intensidad de iluminación del display que apenas puedo leerlo de un autoradio clarion db288rusb. Gracias