    ADJUST ABLE SPEED DRIVE Series 5 Inverter NEMA 4X, IP-65 8/01 MN781B Installation & Operating Manual ...

  • Baldor Series 5 Inverter IP-65 - page 2

    T ABLE OF CONTENTS Section Page i. Simplified Operating Instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 ii. Safety W arning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 I. Introduction . . . . . . . . . . . . . . . . . . . . . . . . ...

  • Baldor Series 5 Inverter IP-65 - page 3

    i . SIMPLIFIED OPERA TING INSTRUCTIONS W ARNING! Disconnect main power when making connections to the control. A . AC Line Connection – Connect the AC line to L1 and L2 terminals of T erminal Block TB1 and the ground wire (Earth) to the green ground screw as shown in Figure 4, on page 6, and as described in Section IIA, on page 6, and Section IIB ...

  • Baldor Series 5 Inverter IP-65 - page 4

    I. INTRODUCTION The Baldor ID5601-BO Adjustable Speed Drive is a variable speed control in a NEMA-4X / IP- 65 and watertight enclosure. It is designed to operate 208 - 230 V olt 3-phase AC induction motors through 3.6 Amps RMS. The sine wave coded Pulse Width Modulated (PWM) output, which operates at a frequency of 8 kHz, provides high motor torque ...

  • Baldor Series 5 Inverter IP-65 - page 5

    3 VIOLET WHITE ORANGE (BACK VIEW) MAIN SPEED POTENTIOMETER (BACK VIEW) START/STOP SWITCH 1. 2. FOR OPTIONAL ID5SI-2 SIGNAL ISOLATOR. ARE USED FOR OPTIONAL R/F, B- AND B+ TERMINALS FWD-STOP-REV SWITCH. REV TERMINAL IS USED RED BLACK WHITE CL BOOST COMP ACCEL DECEL MIN MAX P2 P1 P3 STOP FWD RUN REV COM STOP R/F G B R Y POWER STATUS LED BOARD CON1 J1 ...

  • Baldor Series 5 Inverter IP-65 - page 6

    4 POWER ST A TUS REVERSE FORW ARD STOP ST ART POWER 50 40 0 60 70 80 90 100 ON OFF 30 20 10 AUT O MANUAL STOP % SPEED SHOWN WITH OPTIONAL AUTO/MANUAL AND FORWARD-STOP-REVERSE RECOMMENDED MOUNTING SCREW: 1/4" (M6) 2.53 [139.97] 5.51 [128.59] 5.06 [7.97] 0.31 5.86 9.53 [224.00] 8.82 [208.17] 8.20 [241.96] [64.35] [148.94] ADJUST ABLE SPEED DRIVE ...

  • Baldor Series 5 Inverter IP-65 - page 7

    5 II. WIRING INSTRUCTIONS W ARNING! Read Safety Warning, on page 1, before using this control. Disconnect the AC line before wiring. Note: T o avoid erratic operation, do not bundle AC line and motor wires with wires from sig- nal following, Start/Stop Switch or any other signal wires. Use shielded cables on all signal wiring over 12” (30cm). Shi ...

  • Baldor Series 5 Inverter IP-65 - page 8

    A. AC Line Connection – Wire the AC line input to L1 and L2 terminals of T erminal Block TB1 as shown in Figure 4. Be sure both Jumpers J1 and J2 are set to the “1 15V” posi- tion for 1 15 V olt AC line input or to the “230V” position for 208/230 V olt AC line input. B. Ground Connection – Earth ground the control chassis using the gree ...

  • Baldor Series 5 Inverter IP-65 - page 9

    Note: T o eliminate the Start/Stop function, connect RUN and COM terminals with the jumper that is provided. See Figure 7, on page 6. CAUTION! Using a jumper to eliminate the Start/Stop function will cause the motor to run at the Main Speed Potentiometer setting when the AC line is applied. F . V oltage Following Connection – An isolated 0 - 5 V ...

  • Baldor Series 5 Inverter IP-65 - page 10

    8 fault). T o set the control to automatically reset after a fault has been cleared, set Jumper J3 to the "AUTO" position. See Figure 12. (Also see section VIB, on page 9 and T able 4, on page 10.) W ARNING! The motor will automatically restart when the AC line is applied, if Jumper J4 is set to the "AUT O " o r “ MAN ” posi ...

  • Baldor Series 5 Inverter IP-65 - page 11

    9 B. The hi-pot tester must have an automatic ramp-up to the test voltage and an automatic ramp-down to zero voltage. Note: If the hi-pot tester does not have automatic ramping, then the hi-pot output must be manually increased to the test voltage and then manually reduced to zero. This pro- cedure must be followed for each machine to be tested. A ...

  • Baldor Series 5 Inverter IP-65 - page 12

    10 W ARNING! The motor will automatically start when the AC line is applied or a fault is cleared, if Jumper J4 is set to the “ AUT O ” or “ MAN ” position and the Start/Stop Switch is eliminated. VII. AC LINE FUSING This control does not contain AC line fuses. Most electrical codes require that each ungrounded conductor contain circuit pro ...

  • Baldor Series 5 Inverter IP-65 - page 13

    11 more rapid deceleration time, rotate the DECEL trimpot coun- terclockwise. For longer deceleration time, rotate the DECEL trimpot clockwise. See Figure 20. Note: T o provide increased resolution of the ACCEL and DECEL trimpots, 50% rotation covers 0.3 - 5 seconds. Application Note: On applications with high inertial loads, the deceleration may a ...

  • Baldor Series 5 Inverter IP-65 - page 14

    12 The CL trimpot is factory set for 160% of Jumper J3 range setting. For a higher current limit setting, rotate the CL trimpot clockwise. For a lower current limit setting, rotate the CL trimpot counterclockwise. The current limit also contains I 2 t trip function. The control will trip according to a predetermined current vs. time function. The t ...

  • Baldor Series 5 Inverter IP-65 - page 15

    IX. DIAGNOSTIC LEDs The motor control is designed with LEDs mounted on the front cover to display the control’s operational status. A . Power On (ON) – Indicates the presence of bus voltage. B . Status (ST A TUS) – The Status LED is a tricolor LED that provides indication of the con- trol’s operational status including installation problems ...

  • Baldor Series 5 Inverter IP-65 - page 16

    (A40299) – Rev . A – 3/2001 XI. LIMITED W ARRANTY For a period of 2 years from date of original purchase, BALDOR will repair or replace without charge controls which our examination proves to be defective in material or workmanship. This warranty is valid if the unit has not been tampered with by unauthorized persons, mis- used, abused, or impr ...

Производитель Baldor Категория Power Supply

Документы, которые мы получаем от производителя устройства Baldor Series 5 Inverter IP-65 мы можем разделить на несколько групп. Это в частности:
- технические чертежи Baldor
- инструкции обслуживания Series 5 Inverter IP-65
- паспорта изделия Baldor
- информационные брошюры
- энергетические этикетки Baldor Series 5 Inverter IP-65
Все из них важны, однако самую важную информацию с точки зрения пользователя мы найдем в инструкции обслуживания Baldor Series 5 Inverter IP-65.

Группа документов, определяемая как инструкции обслуживания, делится также на более подробные типы, такие как: Инструкции монтажа Baldor Series 5 Inverter IP-65, инструкции обслуживания, короткие инструкции или инструкции пользователя Baldor Series 5 Inverter IP-65. В зависимости от потребностей, Вам необходимо поискать требуемый документ. На нашем сайте Вы можете просмотреть самую популярную инструкцию использования изделия Baldor Series 5 Inverter IP-65.

Похожие инструкции обслуживания

Полная инструкция обслуживания устройства Baldor Series 5 Inverter IP-65, как должна выглядеть?
Инструкция обслуживания, определяемая также как пособие пользователя, или просто "руководство" - это технический документ, цель которого заключается в использовании Baldor Series 5 Inverter IP-65 пользователями. Инструкции пишет, как правило технический писатель, языком, доступным для всех пользователей Baldor Series 5 Inverter IP-65.

Полная инструкция обслуживания Baldor, должна заключать несколько основных элементов. Часть из них менее важная, как например: обложка / титульный лист или авторские страницы. Однако остальная часть, должна дать нам важную с точки зрения пользователя информацию.

1. Вступление и рекомендации, как пользоваться инструкцией Baldor Series 5 Inverter IP-65 - В начале каждой инструкции, необходимо найти указания, как пользоваться данным пособием. Здесь должна находится информация, касающаяся местонахождения содержания Baldor Series 5 Inverter IP-65, FAQ и самых распространенных проблем - то есть мест, которые чаще всего ищут пользователи в каждой инструкции обслуживания
2. Содержание - индекс всех советов, касающихся Baldor Series 5 Inverter IP-65, которое найдем в данном документе
3. Советы по использованию основных функций устройства Baldor Series 5 Inverter IP-65 - которые должны облегчить нам первые шаги во время использования Baldor Series 5 Inverter IP-65
4. Troubleshooting - систематизированный ряд действия, который поможет нам диагностировать а в дальнейшем очередность решения важнейших проблем Baldor Series 5 Inverter IP-65
5. FAQ - чаще всего задаваемые вопросы
6. Контактные данные Информация о том, где искать контактные данные производителя / сервисного центра Baldor Series 5 Inverter IP-65 в данной стране, если самостоятельно не получится решить проблему.

У вас вопрос, касающийся Baldor Series 5 Inverter IP-65?

Воспользуйтесь формуляром, находящимся ниже

Если с помощью найденной инструкции Вы не решили свою проблему с Baldor Series 5 Inverter IP-65, задайте вопрос, заполнив следующий формуляр. Если у какого то из пользователей была похожая проблема с Baldor Series 5 Inverter IP-65 со всей вероятностью он захочет поделиться методом ее решения.

Перепишите текст с картинки

Комментарии (0)