Инструкция обслуживания Fluke PN 4060712

20 страниц 1.12 mb
Скачать

Перейти на страницу of 20

Summary
  • Fluke PN 4060712 - page 1

    PN 4060712 April 2012 © 2012 Fluke Corporation. All rights reserved. Pri nted in China. Specifications are subject to change withou t notice. All product names are trademarks of their respectiv e companies. 62 MAX/62 MAX + Infrared Thermometer Users Manual ...

  • Fluke PN 4060712 - page 2

    LIMITED WARRANTY AND LIMITATION OF LI ABILITY This Fluke product will be free from defects in material and workmanship for three years from the date of purchas e. This warrant y does not cover fuses, disposab le batteries, or damage from accident, neglect, misuse, alter ation, contamination, or abnormal conditions of operation or ha ndling. Reselle ...

  • Fluke PN 4060712 - page 3

    i Table of Contents Title Page Introduction ................................................................................................................. 1 How to Contact Fluke ................................................................................................. 1 Safety Information .................................................. ...

  • Fluke PN 4060712 - page 4

    62 MAX/62 MAX + Users Manual ii ...

  • Fluke PN 4060712 - page 5

    1 Introduction The Fluke 62 MAX and 62 MAX + Infrared Thermo meters (the Product) can determine the surface temperature by measuring the amount of infrared energy radiated by the target’s surface. Note that the Japanese models indicate Celsius only. W Warning Read all safety information before you use the Product. How to Contact Fluke To contact ...

  • Fluke PN 4060712 - page 6

    62 MAX/62 MAX + Users Manual 2 Or, visit Fluke's website at www.fluke.com . To register your product, visit http://register.fluke.com . To see, print, or download the latest manual supplement, visit http://us.fluke.com/usen/support/manuals . Safety Information A Warning identifies conditions and procedures that are dangerous to the user. A Cau ...

  • Fluke PN 4060712 - page 7

    Infrared Thermometer Safety Information 3 • See emissivity information for actual temperat ures. Reflective objects result in lower than actual te mperature measuremen ts. These objects pose a burn hazard. • Do not look directl y into the laser w ith optical tools (for e xample, binoculars, telescopes, micros copes ). Opti cal tools can focus t ...

  • Fluke PN 4060712 - page 8

    62 MAX/62 MAX + Users Manual 4 Table 1. Symbols Symbol Meaning Symbol Meaning W Risk of danger. Important information. See Manual. ~ Do not dispose of this product as unsorted municipal waste. Go to Fluke’s website for recycling information. * Warning. Laser. P Conforms to European Union directives.  Battery  Conforms to relevant Australian ...

  • Fluke PN 4060712 - page 9

    Infrared Thermometer Maintenance 5 Maintenance W Caution To avoid damag e to the Product, do n ot leave the ther mometer on or near objects of high tem perature. How to Change the Battery To install or change the AA IEC LR06 battery, open the battery compartment a nd replace the battery as shown in Figure 16. How to Clean the Product Use soap and w ...

  • Fluke PN 4060712 - page 10

    62 MAX/62 MAX + Users Manual 6 Specifications 62 MAX 62 MAX + Temperature Range -30 ° C to 500 ° C (-22 ° F to 932 ° F) -30 ° C to 650 ° C (-22 ° F to 1202 ° F) Accuracy ≥ 0 ° C: ± 1.5 ° C or ± 1.5 % of reading, whichever is greater ( ≥ 32 ° F: ± 3 ° F or ± 1.5 % of reading, whichever is greater) ≥ -10 ° C to <0 ° C: ± 2 ...

  • Fluke PN 4060712 - page 11

    Infrared Thermometer Specifications 7 Optical Resolution 10:1 (calculated at 90 % energy) 12:1 (calculated at 90 % energy) Display Resolution 0.1 ° C (0.2 ° F) Repeatability (% of reading) ± 0.8 % of reading or ± 1.0 ° C (2 ° F), whichever is greater ± 0.5 % of reading or ± 0.5 ° C (1 ° F), whichever is greater Power 1 AA IEC LR06 Battery ...

  • Fluke PN 4060712 - page 12

    62 MAX/62 MAX + Users Manual 8 IP Rating IP 54 per IEC 60529 Drop Test 3 meters Vibration and Shock IEC 68-2-6 2.5 g, 10 to 200 Hz, IEC 68-2-27, 50 g , 11 ms EMC EN 61326-1:2006 EN 61326-2:2006 Standards and Agency Approval Compliance ............................................. EN/IEC 61010-1: 2001 Laser Safety ................................... ...

  • Fluke PN 4060712 - page 13

    Infrared Thermometer The Product 9 The Product 1 2 gtt01.eps ...

  • Fluke PN 4060712 - page 14

    62 MAX/62 MAX + Users Manual 10 3 4 Max/Min/A vg/Diff / 5 56 gtt14.eps ...

  • Fluke PN 4060712 - page 15

    Infrared Thermometer The Product 11 7 10 min OFF + = gtt16.eps ...

  • Fluke PN 4060712 - page 16

    62 MAX/62 MAX + Users Manual 12 9 11 125°F 8 10 0ºC 32ºF 22ºC 72ºF 12 6 3 9 30 Min gtt15.eps ...

  • Fluke PN 4060712 - page 17

    Infrared Thermometer The Product 13 12 13 38 mm @ 300 mm 60 mm @ 600 mm 100 mm @ 900 mm 1.5" @ 12" 2.4" @ 24" 4" @ 36" D S 62 MAX D:S = 10:1 33 mm @ 300 mm 50 mm @ 600 mm 85 mm @ 900 mm 1.4" @ 12" 2" @ 24" 3.4" @ 36" D S 62 MAX + D:S = 12:1 gtt08-11.eps ...

  • Fluke PN 4060712 - page 18

    62 MAX/62 MAX + Users Manual 14 14 70 21 gtt03.eps ...

  • Fluke PN 4060712 - page 19

    Infrared Thermometer The Product 15 15 75° 75° 225° gtt04.eps ...

  • Fluke PN 4060712 - page 20

    62 MAX/62 MAX + Users Manual 16 16 17 + - gtt13.eps ...

Производитель Fluke Категория Thermometer

Документы, которые мы получаем от производителя устройства Fluke PN 4060712 мы можем разделить на несколько групп. Это в частности:
- технические чертежи Fluke
- инструкции обслуживания PN 4060712
- паспорта изделия Fluke
- информационные брошюры
- энергетические этикетки Fluke PN 4060712
Все из них важны, однако самую важную информацию с точки зрения пользователя мы найдем в инструкции обслуживания Fluke PN 4060712.

Группа документов, определяемая как инструкции обслуживания, делится также на более подробные типы, такие как: Инструкции монтажа Fluke PN 4060712, инструкции обслуживания, короткие инструкции или инструкции пользователя Fluke PN 4060712. В зависимости от потребностей, Вам необходимо поискать требуемый документ. На нашем сайте Вы можете просмотреть самую популярную инструкцию использования изделия Fluke PN 4060712.

Похожие инструкции обслуживания

Полная инструкция обслуживания устройства Fluke PN 4060712, как должна выглядеть?
Инструкция обслуживания, определяемая также как пособие пользователя, или просто "руководство" - это технический документ, цель которого заключается в использовании Fluke PN 4060712 пользователями. Инструкции пишет, как правило технический писатель, языком, доступным для всех пользователей Fluke PN 4060712.

Полная инструкция обслуживания Fluke, должна заключать несколько основных элементов. Часть из них менее важная, как например: обложка / титульный лист или авторские страницы. Однако остальная часть, должна дать нам важную с точки зрения пользователя информацию.

1. Вступление и рекомендации, как пользоваться инструкцией Fluke PN 4060712 - В начале каждой инструкции, необходимо найти указания, как пользоваться данным пособием. Здесь должна находится информация, касающаяся местонахождения содержания Fluke PN 4060712, FAQ и самых распространенных проблем - то есть мест, которые чаще всего ищут пользователи в каждой инструкции обслуживания
2. Содержание - индекс всех советов, касающихся Fluke PN 4060712, которое найдем в данном документе
3. Советы по использованию основных функций устройства Fluke PN 4060712 - которые должны облегчить нам первые шаги во время использования Fluke PN 4060712
4. Troubleshooting - систематизированный ряд действия, который поможет нам диагностировать а в дальнейшем очередность решения важнейших проблем Fluke PN 4060712
5. FAQ - чаще всего задаваемые вопросы
6. Контактные данные Информация о том, где искать контактные данные производителя / сервисного центра Fluke PN 4060712 в данной стране, если самостоятельно не получится решить проблему.

У вас вопрос, касающийся Fluke PN 4060712?

Воспользуйтесь формуляром, находящимся ниже

Если с помощью найденной инструкции Вы не решили свою проблему с Fluke PN 4060712, задайте вопрос, заполнив следующий формуляр. Если у какого то из пользователей была похожая проблема с Fluke PN 4060712 со всей вероятностью он захочет поделиться методом ее решения.

Перепишите текст с картинки