    SS-GSC13 www .goodmanmfg.com 11/13 Supersedes 9/13 GSC1 3 S plit S yStem A ir C onditioner 13 Seer / r-22 1½ t o 5 t onS * Complete warranty details available from your local dealer or at www .goodmanmfg.com. Contents Nomenclatur e ....................................... 2 Product Specica tions .......................... 3 Expanded Cooling Data ...

  • Goodman Mfg GSC13 - page 2

    2 www .goodmanmfg.com SS-GSC13 P roduct S Pecifica tionS n omenClA ture Brand Engineering * G Goodman ® (Standard Minor Revision Feature Set Models) Engineering * Product Category Major Revision S Split System Electrical Unit T ype 1 208/230 V , 1 Phase, 60 Hz C Condenser R-22 H Heat Pump R-22 Nominal Capacity 018 1 ½ T ons 042 3 ½ T ons Efficie ...

  • Goodman Mfg GSC13 - page 3

    SS-GSC13 www .goodmanmfg.com 3 P roduct S Pecifica tionS S peCifiCA tionS GSC13 0181G* GSC13 0241F* GSC13 0301E* GSC13 0361G* GSC13 0421C* GSC13 0481C* GSC13 0601D* Cooling Cap acities T onnage 1½ 2 2½ 3 3½ 4 5 Decibels 76 76 72 75 76 76 77 Compre ssor RLA 6.8 10.8 13.5 13.4 15.4 19.2 21.8 LRA 40 56 68 74 87 112 137 Condenser F an Mo tor Horsepo ...

  • Goodman Mfg GSC13 - page 4

    4 www .goodmanmfg.com SS-GSC13 P roduct S Pecifica tionS e xp Anded r AtinGS — GSC1 301 81G* Outdoor Ambient Temper a ture 65 75 85 95 105 115 Entering Indoor Wet Bulb Temper ature IDB Airflow 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 70 525 MBh 15.8 16.4 17.9 - 15.4 16.0 17.5 - 15.1 15.6 17.1 - 14.7 15.2 16.7 - 14.0 ...

  • Goodman Mfg GSC13 - page 5

    SS-GSC13 www .goodmanmfg.com 5 P roduct S Pecifica tionS e xp Anded r AtinGS — GSC1 301 81G* ( Cont .) Outdoor Ambient Temper a ture 65 75 85 95 105 115 Entering Indoor Wet Bulb Temper ature IDB Airflow 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 80 525 MBh 16.4 16.7 17.9 19.1 16.0 16.3 17.4 18.6 15.6 15.9 17.0 18.2 15 ...

  • Goodman Mfg GSC13 - page 6

    6 www .goodmanmfg.com SS-GSC13 P roduct S Pecifica tionS e xp Anded r AtinGS — GSC1 302 4 1f* Outdoor Ambient Temper a ture 65 75 85 95 105 115 Entering Indoor Wet Bulb Temper ature IDB Airflow 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 70 700 MBh 20.0 20.8 22.7 - 19.6 20.3 22.2 - 19.1 19.8 21.7 - 18.6 19.3 21.1 - 17. ...

  • Goodman Mfg GSC13 - page 7

    SS-GSC13 www .goodmanmfg.com 7 P roduct S Pecifica tionS e xp Anded r AtinGS — GSC1 302 4 1f* ( Cont .) Outdoor Ambient Temper a ture 65 75 85 95 105 115 Entering Indoor Wet Bulb Temper ature IDB Airflow 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 80 700 MBh 20.7 21.2 22.6 24.2 20.2 20.7 22.1 23.6 19.8 20.2 21.6 23.1 1 ...

  • Goodman Mfg GSC13 - page 8

    8 www .goodmanmfg.com SS-GSC13 P roduct S Pecifica tionS e xp Anded r AtinGS — GSC1 30 3 01** Outdoor Ambient Temper a ture 65 75 85 95 105 115 Entering Indoor Wet Bulb Temper ature IDB Airflow 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 70 831 MBh 25.1 26.0 28.5 - 24.5 25.4 27.9 - 23.9 24.8 27.2 - 23.4 24.2 26.5 - 22. ...

  • Goodman Mfg GSC13 - page 9

    SS-GSC13 www .goodmanmfg.com 9 P roduct S Pecifica tionS e xp Anded r AtinGS — GSC1 30 3 01** ( Cont .) Outdoor Ambient Temper a ture 65 75 85 95 105 115 Entering Indoor Wet Bulb Temper ature IDB Airflow 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 80 831 MBh 26.0 26.6 28.4 30.3 25.4 25.9 27.7 29.6 24.8 25.3 27.1 28.9 2 ...

  • Goodman Mfg GSC13 - page 10

    10 www .goodmanmfg .com SS-GSC13 P roduct S Pecifica tionS e xp Anded C oolinG d At A — GSC13 0 3 6 1G* Outdoor Ambient Temper a ture 65 75 85 95 105 115 Entering Indoor Wet Bulb Temper ature IDB Airflow 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 70 963 MBh 30.0 31.1 34.1 - 29.3 30.4 33.3 - 28.6 29.7 32.5 - 27.9 29.0 ...

  • Goodman Mfg GSC13 - page 11

    SS-GSC13 www .goodmanmfg.com 11 P roduct S Pecifica tionS e xp Anded C oolinG d At A — GSC13 0 3 6 1G* ( Cont .) Outdoor Ambient Temper a ture 65 75 85 95 105 115 Entering Indoor Wet Bulb Temper ature IDB Airflow 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 80 963 MBh 31.1 31.8 33.9 36.3 30.4 31.0 33.1 35.4 29.6 30.3 32 ...

  • Goodman Mfg GSC13 - page 12

    12 www .goodmanmfg .com SS-GSC13 P roduct S Pecifica tionS e xp Anded r AtinGS — GSC1 30421C* Outdoor Ambient Temper a ture 65 75 85 95 105 115 Entering Indoor Wet Bulb Temper ature IDB Airflow 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 70 1225 MBh 35.6 36.9 40.4 - 34.8 36.0 39.5 - 33.9 35.2 38.5 - 33.1 34.3 37.6 - 31 ...

  • Goodman Mfg GSC13 - page 13

    SS-GSC13 www .goodmanmfg.com 13 P roduct S Pecifica tionS e xp Anded r AtinGS — GSC1 30421C* ( Cont .) Outdoor Ambient Temper a ture 65 75 85 95 105 115 Entering Indoor Wet Bulb Temper ature IDB Airflow 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 80 1225 MBh 36.8 37.6 40.2 43.0 36.0 36.8 39.3 42.0 35.1 35.9 38.3 41.0 3 ...

  • Goodman Mfg GSC13 - page 14

    14 www .goodmanmfg .com SS-GSC13 P roduct S Pecifica tionS e xp Anded r AtinGS — GSC1 30481C* Outdoor Ambient Temper a ture 65 75 85 95 105 115 Entering Indoor Wet Bulb Temper ature IDB Airflow 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 70 1400 MBh 40.8 42.3 46.3 - 39.9 41.3 45.3 - 38.9 40.3 44.2 - 38.0 39.3 43.1 - 36 ...

  • Goodman Mfg GSC13 - page 15

    SS-GSC13 www .goodmanmfg.com 15 P roduct S Pecifica tionS e xp Anded r AtinGS — GSC1 30481C* ( Cont .) Outdoor Ambient Temper a ture 65 75 85 95 105 115 Entering Indoor Wet Bulb Temper ature IDB Airflow 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 80 1400 MBh 42.2 43.2 46.1 49.3 41.3 42.2 45.0 48.1 40.3 41.2 44.0 47.0 3 ...

  • Goodman Mfg GSC13 - page 16

    16 www .goodmanmfg .com SS-GSC13 P roduct S Pecifica tionS e xp Anded r AtinGS — GSC1 30601d* Outdoor Ambient Temper a ture 65 75 85 95 105 115 Entering Indoor Wet Bulb Temper ature IDB Airflow 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 70 1400 MBh 48.1 49.9 54.7 - 47.0 48.7 53.4 - 45.9 47.6 52.1 - 44.8 46.4 50.9 - 42 ...

  • Goodman Mfg GSC13 - page 17

    SS-GSC13 www .goodmanmfg.com 17 P roduct S Pecifica tionS e xp Anded r AtinGS — GSC1 30601d* ( Cont .) Outdoor Ambient Temper a ture 65 75 85 95 105 115 Entering Indoor Wet Bulb Temper ature IDB Airflow 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 80 1400 MBh 49.8 50.9 54.4 58.2 48.7 49.7 53.1 56.8 47.5 48.5 51.9 55.4 4 ...

  • Goodman Mfg GSC13 - page 18

    18 www .goodmanmfg .com SS-GSC13 P roduct S Pecifica tionS AHRI R A tIngs Outdoor Unit Coil C ooling Ra tings CFM AHRI # T ot al¹ Sens.¹ SEER² EER³ GSC130241F* CA*F1824*6B*+EEP 22,800 17,600 13 11 800 4700186 GSC130301(D,E)* CA*F3030*6B*+EEP 27,600 21,000 13 11 950 4705227 GSC130481C* CA*F4961*6A*+EEP 44,500 33,800 13 11 1,600 5528473 GSC130421 ...

  • Goodman Mfg GSC13 - page 19

    SS-GSC13 www .goodmanmfg.com 19 P roduct S Pecifica tionS W IRIng D IAgRAm USE N.E .C. CLAS S 2 W IRE COMP ALTERNAT E DO UBLE POLE CO NTACT OR ONLY IO T1 C M A I N R A U X 5 S SR SA 2 1 RCCF SC T2 C L1 L2 (IF USED) CH C F M A I N A U X C C 0140R 0001 5P-A BL Y C LVJB COLOR CODE BK -------- ------- BLACK BL ----- --------- - BLUE BR ----- ------ --- ...

  • Goodman Mfg GSC13 - page 20

    20 www .goodmanmfg .com SS-GSC13 P roduct S Pecifica tionS Goodman Manufacturing Company , L.P ., r eserves the right to discontinue, or change at any time, specications or designs without notice or without incurring obligations. © 2013 • Goodman Manufacturing Company , L.P . • Houston, T exas • Printed in the USA. A ccessoRIes Model Desc ...

Производитель Goodman Mfg Категория Air Conditioner

Документы, которые мы получаем от производителя устройства Goodman Mfg GSC13 мы можем разделить на несколько групп. Это в частности:
- технические чертежи Goodman Mfg
- инструкции обслуживания GSC13
- паспорта изделия Goodman Mfg
- информационные брошюры
- энергетические этикетки Goodman Mfg GSC13
Все из них важны, однако самую важную информацию с точки зрения пользователя мы найдем в инструкции обслуживания Goodman Mfg GSC13.

Группа документов, определяемая как инструкции обслуживания, делится также на более подробные типы, такие как: Инструкции монтажа Goodman Mfg GSC13, инструкции обслуживания, короткие инструкции или инструкции пользователя Goodman Mfg GSC13. В зависимости от потребностей, Вам необходимо поискать требуемый документ. На нашем сайте Вы можете просмотреть самую популярную инструкцию использования изделия Goodman Mfg GSC13.

Похожие инструкции обслуживания

Полная инструкция обслуживания устройства Goodman Mfg GSC13, как должна выглядеть?
Инструкция обслуживания, определяемая также как пособие пользователя, или просто "руководство" - это технический документ, цель которого заключается в использовании Goodman Mfg GSC13 пользователями. Инструкции пишет, как правило технический писатель, языком, доступным для всех пользователей Goodman Mfg GSC13.

Полная инструкция обслуживания Goodman Mfg, должна заключать несколько основных элементов. Часть из них менее важная, как например: обложка / титульный лист или авторские страницы. Однако остальная часть, должна дать нам важную с точки зрения пользователя информацию.

1. Вступление и рекомендации, как пользоваться инструкцией Goodman Mfg GSC13 - В начале каждой инструкции, необходимо найти указания, как пользоваться данным пособием. Здесь должна находится информация, касающаяся местонахождения содержания Goodman Mfg GSC13, FAQ и самых распространенных проблем - то есть мест, которые чаще всего ищут пользователи в каждой инструкции обслуживания
2. Содержание - индекс всех советов, касающихся Goodman Mfg GSC13, которое найдем в данном документе
3. Советы по использованию основных функций устройства Goodman Mfg GSC13 - которые должны облегчить нам первые шаги во время использования Goodman Mfg GSC13
4. Troubleshooting - систематизированный ряд действия, который поможет нам диагностировать а в дальнейшем очередность решения важнейших проблем Goodman Mfg GSC13
5. FAQ - чаще всего задаваемые вопросы
6. Контактные данные Информация о том, где искать контактные данные производителя / сервисного центра Goodman Mfg GSC13 в данной стране, если самостоятельно не получится решить проблему.

У вас вопрос, касающийся Goodman Mfg GSC13?

Воспользуйтесь формуляром, находящимся ниже

Если с помощью найденной инструкции Вы не решили свою проблему с Goodman Mfg GSC13, задайте вопрос, заполнив следующий формуляр. Если у какого то из пользователей была похожая проблема с Goodman Mfg GSC13 со всей вероятностью он захочет поделиться методом ее решения.

Перепишите текст с картинки

Комментарии (0)