    TORNADO INDUSTRIES 7401 W. LAWRENCE AVENUE CHICAGO, IL 60706 (708) 867-5100 FAX (708) 867-6968 www.tornadovac.com Tornado £ Operation & Maintenance Manual For Commercial Use Only Marathon 2000 Forward Only Extractor CATALOG NO. 98190 (115V, 60 HZ) For parts list see L8190GHP Effective 12/19/2005 L8190GH Revised 12/05 ¤ 2006 Tornado Industries ...

  • Tornado 98190 - page 2

    2 NOTES ...

  • Tornado 98190 - page 3

    3 Write your machine’s serial number here:_________________________________ This illustrated instruction book covers: CATALOG NO. 98190 SERIES H SIZE 22” CAPACITY 20 Gal. VOLTS 115V AMPS 15 All specifications are subject to change without notice. TABLE OF CONTENTS: Warranty 4 Safety Instructions 5 Preparation & General Precautions 6 Cleanin ...

  • Tornado 98190 - page 4

    4 Thank you for choosing Tornado products. We are proud to offer the most complete line of commercial and industrial cleaning equipment in the industry. Our reputation for quality, innovation and durability is unsurpassed. * Effective Januar y 1 st , 2005. Terms subject t o change without notice. 1) Windshear™ Blower-Dryer, I nsulation Blowers, T ...

  • Tornado 98190 - page 5

    5 IMPORTANT SAFETY INSTRUCTIONS FOR COMMERCIAL USE WHEN USING AN ELECTRICAL APPLIANCE, BASIC PRECAUTIONS SHOUL D ALWAYS BE FOLLOWED INCLUDING THE FOLLOWING: READ ALL INSTRUCTIONS BEFORE USING THIS MACHINE WARNING: TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY: 1. Do not leave machine when plugged in. Unplug from outlet when not in use and b ...

  • Tornado 98190 - page 6

    6 SAVE THESE INSTRUCTIONS BEFORE OPERATING THE MACHINE Read the manual carefully and completely before attempting to operate the unit. This manual has important information for the use and safe operation of the machine. Keep this manual on file and handy. This machine will assure years of satisfactory service if operated and maintained according to ...

  • Tornado 98190 - page 7

    7 GENERAL PRECAUTIONS x Make sure the machine is plugged into an electrical outlet with the same voltage and frequency rating as shown on the nameplate of the machine. Do not attempt to plug a 115-volt machine in a 230-volt outlet. x Disconnect power cord from the outlet before attempting maintenance or repair work. Do not leave machine connected t ...

  • Tornado 98190 - page 8

    8 ELECTRICAL This machine operates on a standard, 15 AMP, 115 volt AC circuit and has a grounded plug.* Make sure the machine is connected to an outlet having the same configuration as the plug. No ungrounded adapter should be used with this machine. * Special voltage models available. GROUNDING INSTRUCTIONS This machine must be grounded. If it sho ...

  • Tornado 98190 - page 9

    9 Sketch A S ketch B Sketch C STRAIN RELIEF Attaching the strain relief/cord retainer to the 50’ power cord. 1. Make a loop in power cord approximately 12” from receptacle end. 2. Slide cord loop through slot in retainer and over retainer arm. Pull slack cord back through slot to secure. Attach re tainer to handle. EXTENSION CORD If an extensio ...

  • Tornado 98190 - page 10

    10 CLEANING TIPS x Check the condition of the carpeting. If the carpet is loose, heavily soiled, stained, spotted or badly worn, point this out to the person in charge. x Locate an inconspicuous spot on the area to be cleaned. Test carpet for colorfastness before proceeding. Pour the concentrated cleaning solution on the spot, cover with a white to ...

  • Tornado 98190 - page 11

    11 MACHINE SPECIFICATIONS Q ELECTRICAL: 115 V, 15 A, 60 HZ. Q DURABLE EXTENSION CORD: 75 ’ Q DRIVE SYSTEM: TRANSAXLE W/ VARIABLE SPEED, (0-100 FT/MIN) Q VACUUM MOTOR: 3 STAGE, 1 HP., 120 CFM Q VACUUM SHOE: 22” WIDE, CAST AL UMINUM, ADJUSTABLE, FLOATING ARM Q BRUSH: 19” LONG Q BRUSH SPEED /HP: 1000 RPM / 1/4 HP Q SOLUTION PUMP: 100 PSI, DIAPHR ...

  • Tornado 98190 - page 12

    12 OPERATION INSTRUCTIONS Main Controls: Your Marathon 2000 extractor is equipped with (4) main switches, which control the spray bar, the brush motor, the vacuum motor and the main power. The main switch must be activated before operating the transaxle drive. The machine will glide easily across the floor when pushed forward (without power). The m ...

  • Tornado 98190 - page 13

    13 Set Up and Operation: Your Marathon 2000 is shipped complete and ready for carpet cleaning. This style of machine is sometimes referred to as a self-contained extractor, since everything is included in the body of the Marathon 2000 extractor. 1. Install recovery tank cover to the top of the tank and connect the suction hose to the cover. 2. Impo ...

  • Tornado 98190 - page 14

    14 15. While cleaning, pre-spray traffic areas and spots using the spray wand. The spray wand is attached to a quick disconnect and is pressurized when the MAIN SWITCH is turned on. WARNING: To avoid serious injury: Disconnect power before servicing. Electrical service must be performed by an authorized service station or electrician. Use only nonf ...

  • Tornado 98190 - page 15

    15 x Be sure to use Tornado genuine parts and service is provided by an authorized Tornado Service Center. Use of non-O.E.M. parts will void the warranty. PROTECT FROM FREEZING - Caution! If it becomes necessary to store in temperatures that could drop below 40 degrees F, the pumping system, hoses and valves must be protected from freezing with a m ...

  • Tornado 98190 - page 16

    16 Troubleshooting Table: Problem Solution No Power, Nothing Works * Plug in Cord, Check Circuit Breakers * Activate Main Power Switch * Check For Loose Wiring * Call Service Machine Will Not Move Forward * Reset Circuit Breaker * Turn Speed Control Knob Clockwise * Call Service Brush Does Not Rotate * Reset Circuit Breaker * Activate Brush Switch ...

Производитель Tornado Категория Vacuum Cleaner

Документы, которые мы получаем от производителя устройства Tornado 98190 мы можем разделить на несколько групп. Это в частности:
- технические чертежи Tornado
- инструкции обслуживания 98190
- паспорта изделия Tornado
- информационные брошюры
- энергетические этикетки Tornado 98190
Все из них важны, однако самую важную информацию с точки зрения пользователя мы найдем в инструкции обслуживания Tornado 98190.

Группа документов, определяемая как инструкции обслуживания, делится также на более подробные типы, такие как: Инструкции монтажа Tornado 98190, инструкции обслуживания, короткие инструкции или инструкции пользователя Tornado 98190. В зависимости от потребностей, Вам необходимо поискать требуемый документ. На нашем сайте Вы можете просмотреть самую популярную инструкцию использования изделия Tornado 98190.

Похожие инструкции обслуживания

Полная инструкция обслуживания устройства Tornado 98190, как должна выглядеть?
Инструкция обслуживания, определяемая также как пособие пользователя, или просто "руководство" - это технический документ, цель которого заключается в использовании Tornado 98190 пользователями. Инструкции пишет, как правило технический писатель, языком, доступным для всех пользователей Tornado 98190.

Полная инструкция обслуживания Tornado, должна заключать несколько основных элементов. Часть из них менее важная, как например: обложка / титульный лист или авторские страницы. Однако остальная часть, должна дать нам важную с точки зрения пользователя информацию.

1. Вступление и рекомендации, как пользоваться инструкцией Tornado 98190 - В начале каждой инструкции, необходимо найти указания, как пользоваться данным пособием. Здесь должна находится информация, касающаяся местонахождения содержания Tornado 98190, FAQ и самых распространенных проблем - то есть мест, которые чаще всего ищут пользователи в каждой инструкции обслуживания
2. Содержание - индекс всех советов, касающихся Tornado 98190, которое найдем в данном документе
3. Советы по использованию основных функций устройства Tornado 98190 - которые должны облегчить нам первые шаги во время использования Tornado 98190
4. Troubleshooting - систематизированный ряд действия, который поможет нам диагностировать а в дальнейшем очередность решения важнейших проблем Tornado 98190
5. FAQ - чаще всего задаваемые вопросы
6. Контактные данные Информация о том, где искать контактные данные производителя / сервисного центра Tornado 98190 в данной стране, если самостоятельно не получится решить проблему.

У вас вопрос, касающийся Tornado 98190?

Воспользуйтесь формуляром, находящимся ниже

Если с помощью найденной инструкции Вы не решили свою проблему с Tornado 98190, задайте вопрос, заполнив следующий формуляр. Если у какого то из пользователей была похожая проблема с Tornado 98190 со всей вероятностью он захочет поделиться методом ее решения.

Перепишите текст с картинки

Комментарии (0)