    ® Home Theatre In-W all P owerCenter ™ 15 Amp And 20 Amp Models Owner’ s Manual ...

  • Monster Cable 15 Amp - page 2

    ...

  • Monster Cable 15 Amp - page 3

    T ABLE OF CONTENTS P age Important Safety Information i Proper Grounding and Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . iii A Note from The Head Monster . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ...

  • Monster Cable 15 Amp - page 4

    i IMPOR T ANT SAFETY INFORMA TION Please read and observe the following safety points at all times . W ARNING – Installation Monster recommends the In-Wall P owerCenter be installed by a licensed electrician. W ARNING – P ower Sources Suitable for use on a circuit capable of delivering not more than 5000 rms symmetrical amperes, 125 volts maxim ...

  • Monster Cable 15 Amp - page 5

    ii W ARNING – P ower Cord Safety T his In-Wall P owerCenter includes a high-current IEC P owerLine TM 200 A C Power Cable with a low-profile , right angle plug. If the cable’ s protective jack et begins to rip or fray , exposing the internal wiring, shielding, etc., disconnect it immediately . See the W arranty Information section of this owner ...

  • Monster Cable 15 Amp - page 6

    iii PROPER GROUNDING AND INST ALLA TION W ARNING – Proper Grounding A Monster PowerCenter requires a properly grounded outlet for safety and to protect connected equipment. If you’re not sure if your home’ s electrical wiring is properly grounded, have it check ed by a qualified electrician. IMPORT ANT NOTE – Proper P ower and Protection T ...

  • Monster Cable 15 Amp - page 7

    1 A NO TE FROM THE HEAD MONSTER Dear Enthusiast, THANK Y OU for purchasing the Monster P ower ® Home T heatre In-W all P owerCenter ™ . T his PowerCenter reflects our commitment to creating performance-enhancing solutions for home theater systems that deliver superior sound and picture quality . As a long-time audiophile and serious home theater ...

  • Monster Cable 15 Amp - page 8

    2 MONSTER’S P A TENTED CLEAN POWER ™ ST AGES Monster Clean Power ™ performs two tasks that are vital to maintaining optimum home theater performance: 1) noise filtration and 2) noise isolation. The higher the Clean Power stage number (1-5), the more sophisticated and advanced the filters are that reject noise generated on the A C powerline . ...

  • Monster Cable 15 Amp - page 9

    3 THE MINDS BEHIND THE MONSTER POWERCENTER DESIGN Richard Marsh – T here are few experts able to solve the complex problems associated with AC power and complex home theater systems. Richard Marsh is one of these illustrious few . He has designed best selling power conditioning components costing more than $3,000 and now brings his expertise to M ...

  • Monster Cable 15 Amp - page 10

    4 IN-W ALL POWERCENTER FEA TURES 7 1 2 4 5 6 INSERTS INCLUDED 3 1 0 1 2 13 1 0 IEC CABLE 9 8 1 1 1 4 ...

  • Monster Cable 15 Amp - page 11

    5 IN-W ALL POWERCENTER FEA TURES 1. Monster Clean P ower TM and Surge Suppression Module: F eatures patented Monster Clean Power Stage 1 v .2.0 to reduce interference coming through the A C power line, and a 1260 joule rating with new T ri-Mode MOVs to offer superior surge absorption. 2. “Clean P ower” On Indicator: Indicates Monster Clean Powe ...

  • Monster Cable 15 Amp - page 12

    6 HOOK-UP GUIDE – ST ANDALONE APPLICA TIONS Outlet Box Installation F or existing construction environments, you will need to cut a hole in your wall to first install the two gang outlet box that will go behind your Monster In-Wall P owerCenter . Monster strongly recommends you enlist the help of a licensed electrician, or someone experienced wit ...

  • Monster Cable 15 Amp - page 13

    7 B) Fish the line (Black), neutral (White), and ground (Green) wires out from behind the wall. Punch out the two gang outlet box’ s entry holes as necessary for wire routing, and thread the wires through. C) Place the two gang outlet box into the wall hole with the tabs retracted. Carefully turn the screws clockwise until the tabs rotate upright ...

  • Monster Cable 15 Amp - page 14

    8 Surge Module Installation T he Surge Module features patented Monster Clean P ower Stage 1 v .2.0 to reduce interference coming through the AC power line to your components and provides surge protection against damaging voltage surges and spik es . A) Strip about a half inch of insulation off the ends of the line (Black), neutral (White), and gro ...

  • Monster Cable 15 Amp - page 15

    9 T wo-Outlet Receptacle Installation Monster In-Wall P owerCenters are available with either 15-amp or 20-amp outlet. Be sure to use the outlet that matches your existing branch circuit. A) Connect the output wires extending from the Surge Module to the two-outlet receptacle as follows: 1. Remove the three screws from the side of the two-outlet re ...

  • Monster Cable 15 Amp - page 16

    10 HOOK-UP GUIDE – ST AND ALONE APPLICA TIONS Coaxial Connections Installation In-W all PowerCenter comes with a decora plate and two coaxial connections units that provide surge protection against damaging voltage surges and spikes on incoming coax cables. If you have in-wall provisions for satellite TV , TV/cable , cable modem, etc., you can pr ...

  • Monster Cable 15 Amp - page 17

    11 HOOK-UP GUIDE – REMO TE APPLICA TIONS A Remote Application occurs when the TV display and components (receivers, PVRs, DVD players, VCRs , amplifiers , etc.) are connected to different A C outlet receptacle banks . In this application, and for ultimate system protection, two In-W all PowerCenters should be used for proper installation and syst ...

  • Monster Cable 15 Amp - page 18

    12 HOOK-UP GUIDE – REMO TE APPLICA TIONS Surge Module Installation T he Surge Module features patented Monster Clean P ower ™ Stage 1 v .2.0 to reduce interference coming through the AC power line to your components and provides surge protection against damaging voltage surges and spik es . A) Strip about a half inch of insulation off the ends ...

  • Monster Cable 15 Amp - page 19

    13 HOOK-UP GUIDE – REMO TE APPLICA TIONS B) Connect the output wires extending from the Surge Module to the two-outlet receptacle as follows: 1. Remove the three screws from the side of the two-outlet receptacle by turning each counterclockwise until loose. 2. Align the ring terminal holes on the output wires with the screw holes . 3. Reinsert th ...

  • Monster Cable 15 Amp - page 20

    14 Coaxial Connections and Decora Plate Installation In-W all PowerCenter comes with two coaxial connections units that provide surge protection against damaging voltage surges and spikes on incoming coax cables . If you have in-wall provisions for satellite TV , TV/cable , cable modem, etc., you can protect them by hooking them up through the P ow ...

  • Monster Cable 15 Amp - page 21

    15 TROUBLESHOO TING Symptom P ossible Cause Remedy Outlets not receiving power . • Surge Module input wires (line, neutral, ground) not connected to household line , neutral, and ground wiring. • Attach the output wires (line , neutral, ground) to the outlets. • Attach the household input wires (line, neutral, ground) to the Surge Module. Gro ...

  • Monster Cable 15 Amp - page 22

    16 IN-W ALL POWERCENTER SPECIFICA TIONS Continuous Duty Electrical Rating 120V/60Hzs not rec Maximum Current Rating 15A/1800W for 15 Amp In-Wall Module 20A/2400W for 20 Amp In-Wall Module Protection Modes Line-Neutral (L-N) Line-Ground (L-G) Neutral-Ground (N-G) T otal Energy Dissipation 1260 Joules Clamping Level (TVSS V oltage) 330 Volts Clamping ...

  • Monster Cable 15 Amp - page 23

    17 LIMITED W ARRANTY FOR CONSUMERS M on st er , L LC , 7 25 1 W es t L ak e Me ad B lv d ., L as V eg a s , NV , US A (“ Mo ns te r ”) e xt en ds Y ou t hi s Li m it ed W a r r an t y . S ta tu to ry o r c om mo n la w m ay p ro vi de Y ou w it h a dd it io na l ri g ht s or r em e di es , w hi ch s h al l no t be af fe ct ed b y t hi s Li mi t ...

  • Monster Cable 15 Amp - page 24

    18 “Connected Equipment Damage” means physical damage caused to Connected Equipment due to a Product Defect (i) by a transient A C power , cable , telephone , or lightning surge while connected to a properly installed Product, (ii) not by a defect or unrelated damaging of the Connected Equipment or a surge/spik e or lightning strike through a s ...

  • Monster Cable 15 Amp - page 25

    19 “W arranty P eriod” means the time period during which Monster must have received Y our F ormal Warr anty Claim. T he different W arranty P eriods related to Product Defects and Connected Equipment Damage are defined in the Specifications T able below . The W arranty P eriod commences on the date when Y ou purchased or received (whichever ...

  • Monster Cable 15 Amp - page 26

    20 CONNE CTED EQU IPMENT D AMA GE. Mo nster wi ll also provid e Y ou w ith a re medy re garding Connect ed Equi pment Damage if (i) Y ou ha ve a cl aim unde r the L imited Wa rran ty for Products becaus e of a Product Defect that cau ses Con nected Equip ment Dam age des pite Adeq uate Use , and (ii) Monster receiv es a F ormal War ran ty Claim fro ...

  • Monster Cable 15 Amp - page 27

    21 SPECIFICA TIONS T ABLE Product Model No . W arranty P eriod for Products Maximum Coverage Amount W arranty P eriod for Connected Equipment Damage In-W all PowerCenter (15 Amp) 2 Y ears $250,000 Maximum 2 Y ears In-W all PowerCenter (20 Amp) 2 Y ears $250,000 Maximum 2 Y ears ...

  • Monster Cable 15 Amp - page 28

    22 FORMAL WARRANTY CLAIM HOW T O MAKE A CLAIM. In the event damage has occurred to Products , Y ou must follow these instructions: (1) Call Monster within two (2) months after Y ou discover a Product Defect (or should have discovered it, if such Product Defect was obvious); (2) Give a detailed explanation of how the damage occurred; (3) Obtain a Re ...

  • Monster Cable 15 Amp - page 29

    NO TES ...

  • Monster Cable 15 Amp - page 30

    NO TES ...

  • Monster Cable 15 Amp - page 31

    NO TES ...

  • Monster Cable 15 Amp - page 32

    Monster , LLC 7251 W est Lake Mead Blvd. • Las V egas, NV 89128 • USA V isit us on the web at: MonsterP ower .com. Call us toll-free in the U. S. at 877-800-8989. The Monster Power Home T heatre In-Wall PowerCenter is protected under U.S . P at. No. 5,589,718. Other Patents Pending. Designed in the USA by the Monster Power Dream T eam and manuf ...

Производитель Monster Cable Категория Home Theater System

Документы, которые мы получаем от производителя устройства Monster Cable 15 Amp мы можем разделить на несколько групп. Это в частности:
- технические чертежи Monster Cable
- инструкции обслуживания 15 Amp
- паспорта изделия Monster Cable
- информационные брошюры
- энергетические этикетки Monster Cable 15 Amp
Все из них важны, однако самую важную информацию с точки зрения пользователя мы найдем в инструкции обслуживания Monster Cable 15 Amp.

Группа документов, определяемая как инструкции обслуживания, делится также на более подробные типы, такие как: Инструкции монтажа Monster Cable 15 Amp, инструкции обслуживания, короткие инструкции или инструкции пользователя Monster Cable 15 Amp. В зависимости от потребностей, Вам необходимо поискать требуемый документ. На нашем сайте Вы можете просмотреть самую популярную инструкцию использования изделия Monster Cable 15 Amp.

Похожие инструкции обслуживания

Полная инструкция обслуживания устройства Monster Cable 15 Amp, как должна выглядеть?
Инструкция обслуживания, определяемая также как пособие пользователя, или просто "руководство" - это технический документ, цель которого заключается в использовании Monster Cable 15 Amp пользователями. Инструкции пишет, как правило технический писатель, языком, доступным для всех пользователей Monster Cable 15 Amp.

Полная инструкция обслуживания Monster Cable, должна заключать несколько основных элементов. Часть из них менее важная, как например: обложка / титульный лист или авторские страницы. Однако остальная часть, должна дать нам важную с точки зрения пользователя информацию.

1. Вступление и рекомендации, как пользоваться инструкцией Monster Cable 15 Amp - В начале каждой инструкции, необходимо найти указания, как пользоваться данным пособием. Здесь должна находится информация, касающаяся местонахождения содержания Monster Cable 15 Amp, FAQ и самых распространенных проблем - то есть мест, которые чаще всего ищут пользователи в каждой инструкции обслуживания
2. Содержание - индекс всех советов, касающихся Monster Cable 15 Amp, которое найдем в данном документе
3. Советы по использованию основных функций устройства Monster Cable 15 Amp - которые должны облегчить нам первые шаги во время использования Monster Cable 15 Amp
4. Troubleshooting - систематизированный ряд действия, который поможет нам диагностировать а в дальнейшем очередность решения важнейших проблем Monster Cable 15 Amp
5. FAQ - чаще всего задаваемые вопросы
6. Контактные данные Информация о том, где искать контактные данные производителя / сервисного центра Monster Cable 15 Amp в данной стране, если самостоятельно не получится решить проблему.

У вас вопрос, касающийся Monster Cable 15 Amp?

Воспользуйтесь формуляром, находящимся ниже

Если с помощью найденной инструкции Вы не решили свою проблему с Monster Cable 15 Amp, задайте вопрос, заполнив следующий формуляр. Если у какого то из пользователей была похожая проблема с Monster Cable 15 Amp со всей вероятностью он захочет поделиться методом ее решения.

Перепишите текст с картинки

Комментарии (0)