  • Maretron FFM100 - page 1

    Revision 1.2 Page i ® ® FFM100 Fuel Flow Monitor User’s Manual Revision 1.2 Copyright © 2012 Maretron, LLP All Rights Reserved Maretron, LLP 9014 N. 23 rd Ave #10 Phoenix, AZ 85021 http://www.maretron.com Maretron Manual Part #: M003010 ...

  • Maretron FFM100 - page 2

    FFM100 User’s Manual Page ii Revision 1.2 Revision History Revision Description 1.0 Release for Review 1.1 Public Release 1.2 Corrected formatting problems in certain figures Added notes about tamper-proof silicone seals on sensor screws Added information about location of sensors ...

  • Maretron FFM100 - page 3

    Revision 1.2 Page iii ® ® Table of Contents 1  General ....................................................................................................................... ......... 1  1.1  Introduc tion .................................................................................................................. .. 1  1.2  ...

  • Maretron FFM100 - page 4

    FFM100 User’s Manual Page iv Revision 1.2 3.5  Configuring Channel #1 ............................................................................................... 15  3.5.1  Enabling/Disabling Channel #1 ......................................................................... 15  3.5.2  Configuring Channel #1 Engine In stance . ...

  • Maretron FFM100 - page 5

    Revision 1.2 Page 1 ® ® 1 General 1.1 Introduction Congratulations on your purchas e of the Maretron Fuel Flow Monitor (FFM100). Maretron has designed and built your monitor to the highest standards for year s of reliable, dependable, and accurate service. Maretron’s Fuel Flow Monitor (FFM 100) is used to adapt up to tw o positive displacement ...

  • Maretron FFM100 - page 6

    FFM100 User’s Manual Page 2 Revision 1.2 1. Unpack the Box (Section 2.1 ) 2. Choose a Mounting Location (Section 2.2 ) 3. Mount the FFM100 (Section 2.3 ) 4. Mount the Flow Sensors and Connect Fluid Lines (Section 2.4 ) 5. Connect the Flow Sens ors to the FFM100 (Section 2.5.1 ) 6. Connect the FFM100 to the NMEA 2000 ® network (Section 2.5.1 ) 7. ...

  • Maretron FFM100 - page 7

    ® ® Figure 1 - M1RSP-2R-E8 and M2RSP- 2R-E8 Accuracy and Pressure Loss Please refer to Figure 2 below for a chart detailing typical accuracy and pressure loss versus flow rate for the M4ARP- 2-E8 fuel flow sensor. Revision 1.2 Page 3 ...

  • Maretron FFM100 - page 8

    FFM100 User’s Manual Figure 2 - M4ARP-2-E8 Typical Accuracy and Pressure Loss 1.6.3 Diesel Fuel Flow Measurement Most diesel engines do not use all of the fuel that is supplied to them by the fuel pump via the supply line. A portion of the fuel is consumed by t he engine, but the majority of the fuel is used for cooling the injection system and r ...

  • Maretron FFM100 - page 9

    ® ® Return Fuel Flow Sens or Fuel Tank Supply Fuel Flow Sens or Engi ne Dis p la y /MFD Fuel Filter Figure 3 - Diesel Fuel Rate Measurem ent Fluid Flow Sensor Locations 1.6.4 Temperature Compensation The task of computing fuel consumption for a diesel engine is further complicated by the following two factors: 1) Diesel fuel ex pands when heated ...

  • Maretron FFM100 - page 10

    FFM100 User’s Manual Page 6 Revision 1.2 into account will result in the fuel consum ption being underestimat ed. In fact, without compensating for temperature, if the engine were consuming no fuel, the return fuel flow rate is greater than the supply fuel rate, since the fuel is expanded by the engine’s heat as it passes through the injection ...

  • Maretron FFM100 - page 11

    Revision 1.2 Page 7 ® ® Max. return flow rate = 5 gall ons / 0.25 hours = 20 gallons per hour Now, add in the engine’s consumption fuel rate at this RPM, which should be readily available from the manufacturer’s documen tation for the engine, and calcul ate the maximum supply flow rate as follows: Max. supply flow rate = Ma x. return flow ra ...

  • Maretron FFM100 - page 12

    FFM100 User’s Manual Page 8 Revision 1.2 1.6.7 Choosing a Fluid Flow Se nsor Mounting Location Choosing a proper mounting location for fluid flow s ensors is critical to obtaining accurate tank level measurements. Because of the positive displacement design of the FFM100 sensors, no pulse dampening or flow straightening is necessary . The install ...

  • Maretron FFM100 - page 13

    Revision 1.2 Page 9 ® ® 2.3 Mounting the FFM100 Attach the FFM100 securely to the vessel usi ng the included stainle ss steel mounting screws or other fasteners as shown in Figure 5 below . Do not use threadlocking compounds containing methacrylate ester, such as Loctite Red (271), as they will cause stress cracking of the plastic enclosure. Figu ...

  • Maretron FFM100 - page 14

    FFM100 User’s Manual Pin # Signal Name Connection 1 P0 Fluid flow sensor 0 power connection 2 G0 Fluid flow sensor 0 ground connection 3 A0 Fluid flow sensor 0 phase A connection 4 B0 Fluid flow sensor 0 phase B connection 5 C0 Fluid flow sensor 0 phase C connection 6 T0 Fluid flow sensor 0 te mperature sensor connection 7 P1 Fluid flow sensor 1 ...

  • Maretron FFM100 - page 15

    ® ® connected or disconnected. Pl ease follow recommended practi ces for installing NMEA 2000 ® network products. Figure 7 – NMEA 2000 ® Connector Face Views 3 Configuring the FFM100 The FFM100 has several confi gurable parameters, which are shown below including the default values. If you are not using the defaul t values, then you will need ...

  • Maretron FFM100 - page 16

    FFM100 User’s Manual Page 12 Revision 1.2 5. Channel #1 (Section 3.5 ) a. Channel Enable/Disable (Section 3.5.1 ) b. Engine Instance (Section 3.5.2 ) c. Engine Label (Section 3.5.3 ) d. K-Factor (Section 3.5.4 ) e. Temperature Coefficient (Section 3.5.5 ) f. Data Damping Period (Section 3.5.6 ) g. Reset Total Volume Recorded (Section 3.5.7 ) h. T ...

  • Maretron FFM100 - page 17

    Revision 1.2 Page 13 ® ® 3.1.5 Configuring Channel #1 Allow Negative Flow The M1RSP-2R-E8, M2RSP-2R-E8, and M4ARP-2- E8 fuel flow sens ors are capable of sensing flow in both directions. When this param eter is in the default state of “Yes”, the FFM100 will report reverse flow on Channel #1 as a negative flow rate. If you do not wish to see n ...

  • Maretron FFM100 - page 18

    FFM100 User’s Manual Page 14 Revision 1.2 the two flow rate measurements as separate parameter s over the NMEA 2000 network. 3.4 Configuring Channel #0 3.4.1 Enabling/Disabling Channel #0 By default, the channel is enabled and will measure the flow ra te and transmit it over the NMEA 2000 network. If this param eter is programmed to “ Disable? ...

  • Maretron FFM100 - page 19

    Revision 1.2 Page 15 ® ® 3.4.9 Configuring Channel #0 Temperature Label Program this parameter with a te xt string which identifies the par ticular temperature parameter being monitored by this channel. Maretron display products will display this label text when you are selecting data to display. 3.5 Configuring Channel #1 3.5.1 Enabling/Disablin ...

  • Maretron FFM100 - page 20

    FFM100 User’s Manual Page 16 Revision 1.2 is programmed with the appropriate value for thermal expansion coefficient of the fluid being measured. The default value of this field is (0. 083%/°C), which is appropriate for diesel fuel. The configuration tools have predefined values for common flui ds: diesel, engine oil, gasoline, and water. You ma ...

  • Maretron FFM100 - page 21

    Revision 1.2 Page 17 ® ® • Ensure that the unit is mounted securely an d cannot be moved relative to the mounting surface. If the unit is loose, ti ghten the screws holding the cable ties. • Check the security of the cable connected to the NMEA 2000 ® interface and tighten if necessary. • Check the security of all of the fluid flow sensor ...

  • Maretron FFM100 - page 22

    FFM100 User’s Manual Page 18 Revision 1.2 5 Troubleshooting If you notice unexpected operation of the Mare tron FFM100, follow the troubleshooting procedures in this section to remedy simple problems. Symptom Troubleshooting Procedure No Fuel Flow data visible on NMEA 2000 ® network. 1. Ensure that the FFM100 is properly connected to the NMEA 20 ...

  • Maretron FFM100 - page 23

    Revision 1.2 Page 19 ® ® 6 Technical Specifications Specifications Parameter Value Comment Accuracy (Differential Mod e) ±1.75% of reading Using M1RSP-2R-E8 sen sors K factors programmed into FFM100 4:1 fuel supply/fuel consumption ratio Accuracy (Two Indepe nde nt Sensors) ±0.25% of reading Using M1RSP-2R-E8 sen sor K factors programmed into F ...

  • Maretron FFM100 - page 24

    FFM100 User’s Manual Page 20 Revision 1.2 Environmental Parameter Value IEC 60945 Classification Exposed Degree of Protection IP64 Operating Temperature -25°C to 55°C Storage Temperature -40°C to 70°C Relative Humidity 93%RH @40° per IEC60945-8.2 Vibration 2-13.2Hz @ ±1mm, 13.2- 100 Hz @ 7m/s 2 per IEC 60945-8.7 Solar Radiation Ultraviolet ...

  • Maretron FFM100 - page 25

    ® ® 8 Installation Template Please check the dimensions before using the fo llowing diagram as a template for drilling the mounting holes because the printing proc ess may have distorted the dimensions. Figure 9 – Mounting Surface Template Revision 1.2 Page 21 ...

  • Maretron FFM100 - page 26

    FFM100 User’s Manual Page 22 Revision 1.2 9 Maretron (2 Year) Limited Warranty Maretron warrants the FFM100 to b e free from defects in materials and workm anship for t wo (2) years from the date of original purchase. If within the applicable per iod any such products shall be p roved to Maretron’s satisfaction to fail to meet the above lim ite ...

  • Maretron FFM100 - page 27

    Revision 1.2 Appendix A – NMEA 2000 ® Interfacing Page A1 ® ® Appendix A – NMEA 2000 ® Interfacing FFM100 NMEA 2000 ® Periodic Data Transmitted PGNs PGN 130312 –Temperature The FFM100 uses this PGN to provide a regular transmission of fluid temperatures. The factory default for periodic transmission rate is once every two seconds. The tr ...

  • Maretron FFM100 - page 28

    FFM100 User’s Manual Page A2 Appendix A – NMEA 2000 ® Interfacing Revision 1.2 6: Fuel Rate – (16-bit signed integer) This fi eld indicates the fuel consumption rate of the engine in units of 0.0001 cubic meters / hour. 7: Total Engine Hours – ( 32-bit unsigned integer) The FFM100 sets this field to a reserved NMEA 2000 value indicating ? ...

Производитель Maretron Категория GPS Receiver

Документы, которые мы получаем от производителя устройства Maretron FFM100 мы можем разделить на несколько групп. Это в частности:
- технические чертежи Maretron
- инструкции обслуживания FFM100
- паспорта изделия Maretron
- информационные брошюры
- энергетические этикетки Maretron FFM100
Все из них важны, однако самую важную информацию с точки зрения пользователя мы найдем в инструкции обслуживания Maretron FFM100.

Группа документов, определяемая как инструкции обслуживания, делится также на более подробные типы, такие как: Инструкции монтажа Maretron FFM100, инструкции обслуживания, короткие инструкции или инструкции пользователя Maretron FFM100. В зависимости от потребностей, Вам необходимо поискать требуемый документ. На нашем сайте Вы можете просмотреть самую популярную инструкцию использования изделия Maretron FFM100.

Похожие инструкции обслуживания

Полная инструкция обслуживания устройства Maretron FFM100, как должна выглядеть?
Инструкция обслуживания, определяемая также как пособие пользователя, или просто "руководство" - это технический документ, цель которого заключается в использовании Maretron FFM100 пользователями. Инструкции пишет, как правило технический писатель, языком, доступным для всех пользователей Maretron FFM100.

Полная инструкция обслуживания Maretron, должна заключать несколько основных элементов. Часть из них менее важная, как например: обложка / титульный лист или авторские страницы. Однако остальная часть, должна дать нам важную с точки зрения пользователя информацию.

1. Вступление и рекомендации, как пользоваться инструкцией Maretron FFM100 - В начале каждой инструкции, необходимо найти указания, как пользоваться данным пособием. Здесь должна находится информация, касающаяся местонахождения содержания Maretron FFM100, FAQ и самых распространенных проблем - то есть мест, которые чаще всего ищут пользователи в каждой инструкции обслуживания
2. Содержание - индекс всех советов, касающихся Maretron FFM100, которое найдем в данном документе
3. Советы по использованию основных функций устройства Maretron FFM100 - которые должны облегчить нам первые шаги во время использования Maretron FFM100
4. Troubleshooting - систематизированный ряд действия, который поможет нам диагностировать а в дальнейшем очередность решения важнейших проблем Maretron FFM100
5. FAQ - чаще всего задаваемые вопросы
6. Контактные данные Информация о том, где искать контактные данные производителя / сервисного центра Maretron FFM100 в данной стране, если самостоятельно не получится решить проблему.

У вас вопрос, касающийся Maretron FFM100?

Воспользуйтесь формуляром, находящимся ниже

Если с помощью найденной инструкции Вы не решили свою проблему с Maretron FFM100, задайте вопрос, заполнив следующий формуляр. Если у какого то из пользователей была похожая проблема с Maretron FFM100 со всей вероятностью он захочет поделиться методом ее решения.

Перепишите текст с картинки

Комментарии (0)