    Agilent E6474A Wireless Network Optimization Platform Configuration Guide ...

  • Agilent Technologies E6474A - page 2

    2 The purpose of this configuration guide is to assist you in ordering the correct system configuration for your application. The Agilent E6474A wireless network optimization platform is used to obtain RF coverage measurements and service performance measurements for wireless communications networks. The Windows ® based software runs on a PC that ...

  • Agilent Technologies E6474A - page 3

    3 This configuration guide is set-out to show the decision process flow you use when choosing your system. See Part 1 See Part 2 See Part 3 See Part 4 See Part 5 See Part 6 See Part 7 See Part 8 Part 9 shows some ordering examples. Support and T raining Options Choose Hardware Accessory Options Choose Mobile V oice Quality T est Choose Phone Option ...

  • Agilent Technologies E6474A - page 4

    4 Part 1: Software Options Select which E6474A software options match your technology and measurement requirements. Review the upgrade section for additional options. cdma cdma W -CDMA License Description One 2000 GSM /UMTS iDEN GPRS Phone measurements 100 101 200 300 400 600 Receiver measurements 110 111 210 310 410 Receiver and phone measurements ...

  • Agilent Technologies E6474A - page 5

    5 Part 2: Platform Software Options Select which E6474A platform software option matches your system needs. License Description Option Number Initialized parallel license key 1 005 1 Multiple phone license 010 Indoor mapping license 030 MapX Mapping software license 040 2 Client data measurement software license 700 Server data measurement software ...

  • Agilent Technologies E6474A - page 6

    6 Part 3: Post-Processing Options Select which post-processing software you require. License Description Option Number Analysis Reporter E6474A -758 Example: T o add Analysis Reporter capability to your system select E6474A -758. R R e e f f e e r r r r a a l l S S t t a a t t e e m m e e n n t t f f o o r r A A c c t t i i x x U U s s e e r r s s ...

  • Agilent Technologies E6474A - page 7

    7 Part 4: Receiver Options Agilent’ s new multi-technology and multi-band receivers support up to four RF bands in a single compact package. The combination of uplink and downlink bands depends on the configuration chosen. All receivers include a integral 12 channel GPS and four-port USB hub. The receivers are listed by option number and by techn ...

  • Agilent Technologies E6474A - page 8

    8 Part 5: Phone Options Select which phone type you require for your system from the E6473B parts below . Alternatively source a supported phone directly from a third party; please refer to the agilent.com website or contact your Agilent representative for a list of supported phones. Phone Descriptions (test mobile) Option Number Sagem GSM 900/1800 ...

  • Agilent Technologies E6474A - page 9

    9 Part 7: Hardware Accessory Options Select which hardware accessories you need with your system. Drive-test System Accessories Direct Connect GPS DR w/Mag Mount Antenna - External GPS device with dead reckoning that can connect to either the Agilent direct connect hub or directly to the laptop via serial port. This option includes a magnetic mount ...

  • Agilent Technologies E6474A - page 10

    10 Part 9: Ordering examples These examples are not a complete list of all possible configurations, they show typical configurations to illustrate the ordering process. CDMA ordering examples Y ou want a cdmaOne phone-based measurement system (single phone). Y ou will provide your own GPS, laptop and phone. Y ou need to order Quantity E6474A : Wire ...

  • Agilent Technologies E6474A - page 11

    11 cdma2000 ordering example Y ou want a cdma2000 phone and receiver-based measurement system for the cellular and PCS bands. Y ou will use the receiver GPS and provide your own laptop. Y ou need to order Quantity E6474A : Wireless network optimization platform E6474A -121: cdma2000 phone & receiver measurement sw license 1 E6474A -040: MapX ma ...

  • Agilent Technologies E6474A - page 12

    12 Y ou want a GPRS combination phone and receiver-based measurement system for the 900/1800MHz band (single phone), with data test capability . Receiver , and phone hardware required. Wireless data measurement software required. Y ou will supply both laptops for drive-test and for the test server . Y ou need to order Quantity E6474A: Wireless netw ...

  • Agilent Technologies E6474A - page 13

    13 iDEN ordering examples Y ou want a iDEN phone-based measurement system (single phone). Y ou will provide your own GPS and laptop. Y ou need to order Quantity E6474A: Wireless network optimization platform E6474A -400: iDEN phone measurement software license 1 E6474A -040: MapX mapping software license 1 Y ou want a iDEN combination phone and rec ...

  • Agilent Technologies E6474A - page 14

    www .agilent.com/find/contactus Product information subject to change without notice. © Agilent T echnologies, Inc. 2007 Printed in UK. March 13, 2007 5989-5545EN Additional Agilent literature Product Overviews Agilent E6474A Wireless Network Optimization Platform Product Overview 5988-3558EN Deploy next generation wireless networks Agilent E6474A ...

Производитель Agilent Technologies Категория Network Router

Документы, которые мы получаем от производителя устройства Agilent Technologies E6474A мы можем разделить на несколько групп. Это в частности:
- технические чертежи Agilent Technologies
- инструкции обслуживания E6474A
- паспорта изделия Agilent Technologies
- информационные брошюры
- энергетические этикетки Agilent Technologies E6474A
Все из них важны, однако самую важную информацию с точки зрения пользователя мы найдем в инструкции обслуживания Agilent Technologies E6474A.

Группа документов, определяемая как инструкции обслуживания, делится также на более подробные типы, такие как: Инструкции монтажа Agilent Technologies E6474A, инструкции обслуживания, короткие инструкции или инструкции пользователя Agilent Technologies E6474A. В зависимости от потребностей, Вам необходимо поискать требуемый документ. На нашем сайте Вы можете просмотреть самую популярную инструкцию использования изделия Agilent Technologies E6474A.

Похожие инструкции обслуживания

Полная инструкция обслуживания устройства Agilent Technologies E6474A, как должна выглядеть?
Инструкция обслуживания, определяемая также как пособие пользователя, или просто "руководство" - это технический документ, цель которого заключается в использовании Agilent Technologies E6474A пользователями. Инструкции пишет, как правило технический писатель, языком, доступным для всех пользователей Agilent Technologies E6474A.

Полная инструкция обслуживания Agilent Technologies, должна заключать несколько основных элементов. Часть из них менее важная, как например: обложка / титульный лист или авторские страницы. Однако остальная часть, должна дать нам важную с точки зрения пользователя информацию.

1. Вступление и рекомендации, как пользоваться инструкцией Agilent Technologies E6474A - В начале каждой инструкции, необходимо найти указания, как пользоваться данным пособием. Здесь должна находится информация, касающаяся местонахождения содержания Agilent Technologies E6474A, FAQ и самых распространенных проблем - то есть мест, которые чаще всего ищут пользователи в каждой инструкции обслуживания
2. Содержание - индекс всех советов, касающихся Agilent Technologies E6474A, которое найдем в данном документе
3. Советы по использованию основных функций устройства Agilent Technologies E6474A - которые должны облегчить нам первые шаги во время использования Agilent Technologies E6474A
4. Troubleshooting - систематизированный ряд действия, который поможет нам диагностировать а в дальнейшем очередность решения важнейших проблем Agilent Technologies E6474A
5. FAQ - чаще всего задаваемые вопросы
6. Контактные данные Информация о том, где искать контактные данные производителя / сервисного центра Agilent Technologies E6474A в данной стране, если самостоятельно не получится решить проблему.

У вас вопрос, касающийся Agilent Technologies E6474A?

Воспользуйтесь формуляром, находящимся ниже

Если с помощью найденной инструкции Вы не решили свою проблему с Agilent Technologies E6474A, задайте вопрос, заполнив следующий формуляр. Если у какого то из пользователей была похожая проблема с Agilent Technologies E6474A со всей вероятностью он захочет поделиться методом ее решения.

Перепишите текст с картинки

Комментарии (0)