Инструкция обслуживания Parker Hannifin vm24

30 страниц 0.35 mb
Скачать

Перейти на страницу of 30

Summary
  • Parker Hannifin vm24 - page 1

    Compumotor VM24 Series User Guide Compumotor Division Parker Hannifin Corporation p/n 88-015965-01A July 1997 External Input/Output Interface Module for 6000 Series Controllers ...

  • Parker Hannifin vm24 - page 2

    VM24 I/O Module Information in this document is subject to change without notice and does not represent a commitment on the part of Parker Hannifin Corporation. No part of this document may be reproduced or transmitted in any form or by any means, electronic or mechanical, including photocopying, recording, or information storage and retrieval syst ...

  • Parker Hannifin vm24 - page 3

    CO NT E NT S Chapter 1. Installation What You Should Have (ship kit) ................................................... 2 Overview — VM24 ..................................................................... 3 Specification Summary ............................................................... 4 VM24 Assembly Configuration...................... ...

  • Parker Hannifin vm24 - page 4

    ...

  • Parker Hannifin vm24 - page 5

    1 C HAP TE R ONE Installation ...

  • Parker Hannifin vm24 - page 6

    2 VM24 I/O Module What You Should Have (ship kit) Part Name Part Number One of the following line items: VM24S single axis I/O module ...................................... VM24S VM24IN multi axis I/O module ...................................... VM24-IN VM24OUT multi axis I/O module.................................. VM24-OUT VM8/16 multi-axis I/O ...

  • Parker Hannifin vm24 - page 7

    Installing the VM24 3 Overview — VM24 The VM24 external I/O modules act as an interface for the general-purpose programmable inputs and outputs of all the 6000 Series servo and microstepping products. The VM24 module consists of a base board and one to three SIM (single in-line module) style boards that can be inserted to provide the user with a ...

  • Parker Hannifin vm24 - page 8

    4 VM24 I/O Module Specification Summary Parameter Specification Power Requirements V o ........................ User-supplied voltage that drives output circuitry. V o does not affect input circuitry, so it is not necessary for the VM24-IN. V o Range................ 5-24VDC V o Current .............. 144mA, plus the sum of the load currents outputs ...

  • Parker Hannifin vm24 - page 9

    Installing the VM24 5 Impedance................ 6 k Ω , minimum. Requires input current (sourcing or sinking) of 0.111mA per volt of user-supplied voltage Vi. (e.g., 1.11mA for V i =10V). Status: .................... Check with the TIN or INFNC command. Active Level: ........... Set by 6000 Series Controller/Indexer. Default is active low, but ca ...

  • Parker Hannifin vm24 - page 10

    6 VM24 I/O Module Undervoltage Protection......... The under-voltage lockout circuit is meant to prevent the output driver from sinking or sourcing unless the user-supplied voltage V o is between 5VDC and 24VDC. Thermal Shutdown .... The thermal shutdown protection is intended to protect the device from marginal environmental factors. It must not b ...

  • Parker Hannifin vm24 - page 11

    Installing the VM24 7 VM24 Assembly Configurations The VM24 is available in five different configurations, as shown in the following table. Each configuration uses the same base unit. The combination of SIM boards installed in the base unit determine the I/O configuration. Description P/N I/O Boards Cable Type Single Axis (16 IN / 8 OUT) VM24S 2 SI ...

  • Parker Hannifin vm24 - page 12

    8 VM24 I/O Module I/O Pin Out Table Screw Terminal Number VM24IN VM24OUT VM24S VM16/8 VM8/16 1 IN #1 OUT #1 IN #1 OUT #1 IN #1 2 IN #2 OUT #2 IN #2 OUT #2 IN #2 3 IN #3 OUT #3 IN #3 OUT #3 IN #3 4 IN #4 OUT #4 IN #4 OUT #4 IN #4 5 IN # 5 OUT #5 OUT #1 OUT #5 IN #5 6 IN # 6 OUT #6 OUT #2 OUT #6 IN #6 7 IN # 7 OUT #7 OUT #3 OUT #7 IN #7 8 IN # 8 OUT ...

  • Parker Hannifin vm24 - page 13

    Installing the VM24 9 Electrical Connections JU1 1 JU2 1 JU3 1 1–8 9–16 17–24 J1 J3 J4 J5 J6 Fig. 2: Top View of the VM24 (shown without boards inserted) J 1 ..... SIM socket for I/O board 1, screw terminals 1-8. J 2 ..... SIM socket for I/O board 2, screw terminals 9-16. J 3 ..... SIM socket for I/O board 3, screw terminals 17-24. J 4 ..... ...

  • Parker Hannifin vm24 - page 14

    10 VM24 I/O Module J4 J5 J1 J2 J3 JU1 JU2 JU3 Fig. 3: Left-Side View of the VM24 (shown with boards inserted) JU1 Jumper for SIM slot J1. JU2 Jumper for SIM slot J2 JU3 Jumper for SIM slot J3 See page 11 for the description of jumper configurations. GND V o V i RIGHT SIDE J5 J6 J3 J2 J1 Fig. 4: Right-Side View of the VM24 (shown with boards inserte ...

  • Parker Hannifin vm24 - page 15

    Installing the VM24 11 Jumper Configuration The jumpers are used to configure the inputs for the I/O boards as sinking or sourcing. Each socket has its own corresponding jumper, allowing each board with inputs to be independently configured for sinking or sourcing. Sinking Inputs: Position 3 (shown) Jumps pull-up to V i (pin 3) Sourcing Inputs: Pos ...

  • Parker Hannifin vm24 - page 16

    12 VM24 I/O Module Ribbon Cable Connection Caution Remove power to the VM24 before attaching or removing the cable. The VM24 is shipped with a 2-foot ribbon cable, with mating connectors. Connectors are keyed to ensure that they are inserted into mating connectors correctly. Cable installation for the VM24S, VM24-IN, and VM24-OUT consists of simply ...

  • Parker Hannifin vm24 - page 17

    Installing the VM24 13 Connect to Output Connector on 6000 Controller Connect to Input Connector on 6000 Controller Connect to J4 Connector on VM16/8 Red Stripe Fig. 6: Split Cable for the VM16/8 ...

  • Parker Hannifin vm24 - page 18

    14 VM24 I/O Module Red Stripe Connect to Output Connector on 6000 Controller Connect to Input Connector on 6000 Controller Connect to J4 Connector on VM8/16 Fig. 7: Split Cable for the VM8/16 ...

  • Parker Hannifin vm24 - page 19

    Installing the VM24 15 Input Connections Caution Remove power to the VM24 before making any connections. Sinking 12 . 1 K Ω 6.81 K Ω 1500 pF 10 . 0 K Ω + - Out 5-24 Volts Output Ground The output should be able to sink at least 3mA of current. Electronic Device 6000 Series Controller ISO Ground VM24 External Supply (up to 24VDC) + – Ground ...

  • Parker Hannifin vm24 - page 20

    16 VM24 I/O Module Output Connections Caution Remove power to the VM24 before making any connections. Connect the output pull-up pin OUT-P of the 6000 Series unit to V o on the VM24 module to ensure the proper sequencing of output signals upon application of power to the VM24. The Output, Ground, and +5V connections between the 6000 Controller and ...

  • Parker Hannifin vm24 - page 21

    Installing the VM24 17 VM24 Module Configuration Summary The VM24 is shipped with the SIM8 boards already installed. 1 . Mount the VM24 module (standard DIN rail). 2 . Set the jumpers to position 3 (default) for sinking inputs or to position 1 for sourcing inputs. (See page 11). 3 . Connect the 50-pin ribbon cable to the I/O connector(s) of the 600 ...

  • Parker Hannifin vm24 - page 22

    ...

  • Parker Hannifin vm24 - page 23

    2 C HAP TER TWO Troubleshooting ...

  • Parker Hannifin vm24 - page 24

    20 VM24 I/O Module Basic Troubleshooting When your system does not function properly (or as you expect it to operate), the first thing that you must do is identify and isolate the problem. When you have accomplished this, you can effectively begin to resolve the problem. • Is the 50-pin ribbon cable connected properly to the 6000 Series Controlle ...

  • Parker Hannifin vm24 - page 25

    Troubleshooting 21 6000 Series Controller/Indexer First, verify that 6000 Series Controller/Indexer I/O is functioning properly to aid in isolating the problem. Disconnect the 50-pin ribbon cable, or just disconnect the cable from connector J4 of the VM24, before performing this test. Outputs: Use the Transfer Output Status ( TOUT ) command to chec ...

  • Parker Hannifin vm24 - page 26

    22 VM24 I/O Module 50-pin Ribbon Cable Next, verify that the ribbon cable is relaying the signals properly. Connect the 50-pin ribbon cable to the 6000 Series unit, but do not connect the other end of the cable to the VM24. Repeat the above test, applying and checking voltages at the connector that would plug into J4. (The red stripe on the ribbon ...

  • Parker Hannifin vm24 - page 27

    Troubleshooting 23 Outputs Use the Transfer Output Status ( TOUT ) command to check the status of the outputs. Use the Output State ( OUT ) command to change the outputs. Use a voltage meter to check individual outputs at the screw terminals (J4) of the VM24 to verify that the voltage level toggles between Ground and ( V o -2). [The output level sh ...

  • Parker Hannifin vm24 - page 28

    24 VM24 I/O Module P/N: SIM8-OUT PARKER COMPUMOTOR Notch Fig. 9: I/O Board and Socket To Insert I/O Boards 1. Insert the I/O board into the socket, as shown in Fig. 9 above, and in Fig. 10 below. Start the I/O board at an angle of approximately 30 ° . 2. Firmly press the board into the socket and rotate it forward until it snaps underneath the met ...

  • Parker Hannifin vm24 - page 29

    Troubleshooting 25 To Remove I/O Boards 1. Gently depress or push the metal socket clamps (see Fig. 11 below) to release the I/O board from the socket. 2. Tilt the I/O board toward the back of the socket and lift it out gently. Never force the I/O board out of the socket without releasing the clamps. Failure to release the clamps may break the sock ...

  • Parker Hannifin vm24 - page 30

    VM24 I/O Module Pin Out Table Screw Terminal Number VM24IN VM24OUT VM24S VM16/8 VM8/16 1 IN #1 OUT #1 IN #1 OUT #1 IN #1 2 IN #2 OUT #2 IN #2 OUT #2 IN #2 3 IN #3 OUT #3 IN #3 OUT #3 IN #3 4 IN #4 OUT #4 IN #4 OUT #4 IN #4 5 IN # 5 OUT #5 OUT #1 OUT #5 IN #5 6 IN # 6 OUT #6 OUT #2 OUT #6 IN #6 7 IN # 7 OUT #7 OUT #3 OUT #7 IN #7 8 IN # 8 OUT #8 OUT ...

Производитель Parker Hannifin Категория Webcam

Документы, которые мы получаем от производителя устройства Parker Hannifin vm24 мы можем разделить на несколько групп. Это в частности:
- технические чертежи Parker Hannifin
- инструкции обслуживания vm24
- паспорта изделия Parker Hannifin
- информационные брошюры
- энергетические этикетки Parker Hannifin vm24
Все из них важны, однако самую важную информацию с точки зрения пользователя мы найдем в инструкции обслуживания Parker Hannifin vm24.

Группа документов, определяемая как инструкции обслуживания, делится также на более подробные типы, такие как: Инструкции монтажа Parker Hannifin vm24, инструкции обслуживания, короткие инструкции или инструкции пользователя Parker Hannifin vm24. В зависимости от потребностей, Вам необходимо поискать требуемый документ. На нашем сайте Вы можете просмотреть самую популярную инструкцию использования изделия Parker Hannifin vm24.

Похожие инструкции обслуживания

Полная инструкция обслуживания устройства Parker Hannifin vm24, как должна выглядеть?
Инструкция обслуживания, определяемая также как пособие пользователя, или просто "руководство" - это технический документ, цель которого заключается в использовании Parker Hannifin vm24 пользователями. Инструкции пишет, как правило технический писатель, языком, доступным для всех пользователей Parker Hannifin vm24.

Полная инструкция обслуживания Parker Hannifin, должна заключать несколько основных элементов. Часть из них менее важная, как например: обложка / титульный лист или авторские страницы. Однако остальная часть, должна дать нам важную с точки зрения пользователя информацию.

1. Вступление и рекомендации, как пользоваться инструкцией Parker Hannifin vm24 - В начале каждой инструкции, необходимо найти указания, как пользоваться данным пособием. Здесь должна находится информация, касающаяся местонахождения содержания Parker Hannifin vm24, FAQ и самых распространенных проблем - то есть мест, которые чаще всего ищут пользователи в каждой инструкции обслуживания
2. Содержание - индекс всех советов, касающихся Parker Hannifin vm24, которое найдем в данном документе
3. Советы по использованию основных функций устройства Parker Hannifin vm24 - которые должны облегчить нам первые шаги во время использования Parker Hannifin vm24
4. Troubleshooting - систематизированный ряд действия, который поможет нам диагностировать а в дальнейшем очередность решения важнейших проблем Parker Hannifin vm24
5. FAQ - чаще всего задаваемые вопросы
6. Контактные данные Информация о том, где искать контактные данные производителя / сервисного центра Parker Hannifin vm24 в данной стране, если самостоятельно не получится решить проблему.

У вас вопрос, касающийся Parker Hannifin vm24?

Воспользуйтесь формуляром, находящимся ниже

Если с помощью найденной инструкции Вы не решили свою проблему с Parker Hannifin vm24, задайте вопрос, заполнив следующий формуляр. Если у какого то из пользователей была похожая проблема с Parker Hannifin vm24 со всей вероятностью он захочет поделиться методом ее решения.

Перепишите текст с картинки

Комментарии (0)