    EP A Wood-Burning Fireplace P/ N 85 0,0 37 M RE V . K 05 /20 10 MONTE MODEL MONTECITO™ INST ALLA TION AND OPERA TION INSTRUCTIONS SA VE THESE INSTRUCTIONS FOR FUTURE REFERENCE Listed to standards: ULC-S610 and UL-127 Report No. 307-4084 EP A Cert. No. 537 W ARNINGS • Hot! Do not touch! The glass and surfaces of this appliance will be hot during ...

  • Lennox Hearth ULC-S610 - page 2

    IMPORT ANT! GENERAL SAFETY PRECAUTIONS. READ AND UNDERST AND THESE SAFETY R UL ES B EF OR E Y OU R F IR S T F IR E . W ARNING T o avoid the risk of damaging fireplace materials and increas- ing the risk of fire, do not use the fireplace to cook or warm food. IMPOR T ANT Wh e n b ur n in g wo od , us e S O LI D NA TU RA L DR Y WEL L -S E AS ON E ...

  • Lennox Hearth ULC-S610 - page 3

    T ABLE OF CONTENTS Safety Rules and Specifications for Mobile or Manufactured Home Installation ......................... Page 2 Introduction ...................................... Page 3 Parts Required ................................. Page 3 Optional Equipment ........................... Page 3 Operating The Montecito Fireplace .... Page 3 Fuel ...

  • Lennox Hearth ULC-S610 - page 4

    Building a Fire (starting and maintaining a fire) T o start a fire, place several crumpled up balls of newspa per in the firebox. Place small dry pieces of kindli ng on top of the paper , criss-c rossi ng the kindling so that there are air spaces in between. Keep the fuel far back enough so that air can get underneath. Open the air controls full ...

  • Lennox Hearth ULC-S610 - page 5

    A. Negative pressure in the house - As the fire burns, air goes up the chimney . This air must be replaced through leakage into the hous e or throug h the outsi de air duct. When operating the Montecito fireplace, open a nearby window temporaril y to check if there is adequate replacement air supply . B. Fans operating (e.g.: range hood) - These ...

  • Lennox Hearth ULC-S610 - page 6

    REFRACTORY REPLACEMENT The intense heat of the fire will normally cause hairline cracks in the refractory . These cracks can be minimized by proper curing as described in“First Fires”.They willnot normallydimin - ish the effectiveness of the refractory . If large cracks develop, then the refracto ...

  • Lennox Hearth ULC-S610 - page 7

    Facade Installation In sta ll the Fac ade pe r i nst ruc ti ons pr ovi ded in Fa cad e K it (o rde red se pa rat ely - se e P age 2 0 ). Framing, Facing And Mantel The construction of the framing, facing, and mantel must be in accordance with the stan- dards and the following illustrations ( Figures 10 and 11 ): A. Frame the replace ...

  • Lennox Hearth ULC-S610 - page 8

    FRAMING DIMENSIONS Fireplace Opening Width A 36-1/4” 921 mm B 42” 1067 mm C 30-1/16” 764 mm D 13-1/2” 343 mm E 77” 1956 mm F 37-1/2” 953 mm G *24-1/2” 603 mm J 53-3/4” 1365 mm K 8” 203 mm L 1” 25 mm Fireplace Framing Header B A OUTSIDE CHASE G C A Back Wal l of C hase/Enclosur e In clu din g F in isi ng Mat er ial s i f any Roug ...

  • Lennox Hearth ULC-S610 - page 9

    Figure 9 Insulated Chase Construction Figure 11 Floor Ceiling Wall • Must have the same firestopping resistance as adjacent wall. • Must have the same insulation as adjacent ceiling. • Follow local rules regarding framing construction. Attic Radiation Shield Roof Support Storm Collar Flashing Drywall or Any Rigid Material 2” x 4” FIREPLAC ...

  • Lennox Hearth ULC-S610 - page 10

    HOT AIR DUCTING INST ALLA TION The Montecito™ wood burning fireplace is approved for use with a Gravity kit (hot air ducting system). Gravity Kit The gravity kit is designed for double hot air outlets and includes: (See Figure 14 ).  - T wo(2)telescopiclengths8”I.D.  - T wo(2)90ºelbows8”I.D ...

  • Lennox Hearth ULC-S610 - page 11

    Figure 17 OUTSIDE AIR KIT It is mandatory to install an outside air connec- tion to the Montecito™ wood burning fireplace. The following components are required and are included with the fireplace: • Outside air kit (includes 40 inch ex that goes up to ten (10) feet long) • 4”Adaptorforreplace? ...

  • Lennox Hearth ULC-S610 - page 12

    Figure 18 OUTSIDE CONNECTION Figure 19 Aluminum T ape Aluminum T ape Fireplace Connection Plastic Cover Insulation Flexible Pipe Fireplace 5. All chimney installations must include at least one support. Re- ducing the amount of chimney weight on the fireplace will help avoid the noise created when the fireplace expands. This can be achieved by ha ...

  • Lennox Hearth ULC-S610 - page 13

    CHIMNEY INST ALLA TION INSTRUCTIONS 1. Cut and frame the holes in the ceiling, floor and roof where the chimney will pass (see Figure 21 ). Use aplumb-bob tolineup the centerof theholes. The sizesare indicated in T able 2 for the floor and ceiling holes and T able 3 ( Page 15 ) for the roof holes ...

  • Lennox Hearth ULC-S610 - page 14

    Roof Down Slope Hole Size S L O P E A S H T + / H T 6 1 0 3 + S - 2 1 00 + / H T 6 0 0 0 + A C R o o f P it c h 6 ” 6 ” 6 ” 0 * 1 2 - 3 /8 ” ( 3 1 4 m m ) 1 4 - 1 /8 ” ( 3 5 9 m m ) 1 5 ” ( 38 0 m m ) 2 / 1 2 1 2 - 9 /1 6” ( 3 1 9 m m ) 1 4 - 3 /8 ” ( 3 6 5 m m ) 1 5 3 /8 ” ( 3 9 0 m m ) 4 / 1 2 1 3 ” (3 30 m m ) 1 4 - 7 / 8 ” ...

  • Lennox Hearth ULC-S610 - page 15

    Figure 26 Ch im ne y 6” Elbo w Offset & Height One Length Between Elbows T wo Lengths Between Elbows 8” 12” 18” 24” 36” 48” 8” & 48” 1 2” & 4 8 ” 1 8” & 4 8 ” 24 ” & 48 ” 36” & 48” 48” & 48” Se c ur e T em p AS H T No v a T em p HT 6 10 3 + 15º A 3- 5 /1 6” (8 4 mm ) 4- 5 /1 6? ...

  • Lennox Hearth ULC-S610 - page 16

    Figure 27 OFFSET CHIMNEY INST ALLA TION Chimney AC Support ACRS Starter Section Rain Cap Collar Roof Flashing Offset Support Insulated Wall Radiation Shield Framing 2” x 3” Figure 28 Straps Straps OF FSE T CHI MN EY IN ST ALLA TIO N WIT H W ALL P ENE TR A TIO N Note: In cold areas it is recom- mended to protect the chimney in a insulated chase. ...

  • Lennox Hearth ULC-S610 - page 17

    If possible, you should choose a location where the chimney will pass throu gh the house without cutting floor or roof joists (see fireplace dimen- sions Page 9 ). Usually , no additional oor support is needed for the fireplace. The adequacy of the floor can be checked by first estimating the weight of the fireplace sy ...

  • Lennox Hearth ULC-S610 - page 18

    CHIMNEY SUPPORT INST ALLA TION Universal Roof Support This support has three possible uses: 1. ForASHT+/ HT6103+andS-2100+/ HT6000+,itmust beusedon a roof to support the chimney . 2. It may be used on a floor , ceiling or roof above an offset to support the chimney above the offset. 3. It may be used on ...

  • Lennox Hearth ULC-S610 - page 19

    INST ALLA TION INSTRUCTIONS FOR MASONRY APPLICA TION WARNING: Before starting the installation, the masonry chimney must be inspected by a qualified chimney sweep. The following requirements must be respected: 1. The chimney must be absolutely clear of any soot residue or creosote. Check for cracks, loose or missing bricks that could inhibit corre ...

  • Lennox Hearth ULC-S610 - page 20

    Installation Accessories Description Cat./ Part No. Facades (Required - Order Separately) Montecito™ Facade Black, MFBK H4843 Montecito Facade Brushed Nickel, MFBN H4844 Montecito Facade Hammered Steel, MFMC H4845 Doors (Required - Order Separately) Montecito Door , Black, MCBK H4846 Montecito Door , Brushed Nickel, MCBN H4847 Montecito Door , Ha ...

  • Lennox Hearth ULC-S610 - page 21

    CHIMNEY - P ARTS AND COMPONENTS LISTS Firep lace Model MONTE - Approved Venti ng Compone nts manufa ctured by Security Chimneys International only . • 6” diameter chimney - AC (air cooled), Secure T emp™ ASHT+ (or Nova T emp™ HT6103+) and Secure T emp S-2100+ (or Nova T emp HT6000+). • 6” di a me te r chi m ne y for rel in in g ...

  • Lennox Hearth ULC-S610 - page 22

    CHIMNEY - P ARTS AND COMPONENTS LISTS (AC) Air -Cooled Chimney System* 6” I.D. and 11” O.D. Air Cooled, Stainl. Steel inner and zinc coated steel exterior * AC Ch i m ne y is N O T re co m m en d e d at el e va ti on s a bo v e 4 ,0 00 f ee t o r in co l d c li ma t e s ( cl i m at e s wh er e te mp er a t ur e s w i ll f al l be lo w 3 2 ° F ...

  • Lennox Hearth ULC-S610 - page 23

    CLEARANCE TO COMBUSTIBLES The following clearances meet the minimum requirements for a safe installation; Side wall: 17”(324mm)measuredfromthereplaceside Ceiling:  6’8”(2,032mm)measuredfromthebaseofthereplace Fireplace enclosure :  Bottom:0”  Side:0”tos ...

  • Lennox Hearth ULC-S610 - page 24

    Printed in Canada © 2006 Lennox Hearth Products P/N 850,037M REV . K 05/2010 24 Y our Fireplace's Model Number ________________________________________ Y our Fireplace's Serial Number ________________________________________ The Date On Which Y our Fireplace Was Installed ___________________________ Y our Dealer's Name _____________ ...

Производитель Lennox Hearth Категория Indoor Fireplace

Документы, которые мы получаем от производителя устройства Lennox Hearth ULC-S610 мы можем разделить на несколько групп. Это в частности:
- технические чертежи Lennox Hearth
- инструкции обслуживания ULC-S610
- паспорта изделия Lennox Hearth
- информационные брошюры
- энергетические этикетки Lennox Hearth ULC-S610
Все из них важны, однако самую важную информацию с точки зрения пользователя мы найдем в инструкции обслуживания Lennox Hearth ULC-S610.

Группа документов, определяемая как инструкции обслуживания, делится также на более подробные типы, такие как: Инструкции монтажа Lennox Hearth ULC-S610, инструкции обслуживания, короткие инструкции или инструкции пользователя Lennox Hearth ULC-S610. В зависимости от потребностей, Вам необходимо поискать требуемый документ. На нашем сайте Вы можете просмотреть самую популярную инструкцию использования изделия Lennox Hearth ULC-S610.

Похожие инструкции обслуживания

Полная инструкция обслуживания устройства Lennox Hearth ULC-S610, как должна выглядеть?
Инструкция обслуживания, определяемая также как пособие пользователя, или просто "руководство" - это технический документ, цель которого заключается в использовании Lennox Hearth ULC-S610 пользователями. Инструкции пишет, как правило технический писатель, языком, доступным для всех пользователей Lennox Hearth ULC-S610.

Полная инструкция обслуживания Lennox Hearth, должна заключать несколько основных элементов. Часть из них менее важная, как например: обложка / титульный лист или авторские страницы. Однако остальная часть, должна дать нам важную с точки зрения пользователя информацию.

1. Вступление и рекомендации, как пользоваться инструкцией Lennox Hearth ULC-S610 - В начале каждой инструкции, необходимо найти указания, как пользоваться данным пособием. Здесь должна находится информация, касающаяся местонахождения содержания Lennox Hearth ULC-S610, FAQ и самых распространенных проблем - то есть мест, которые чаще всего ищут пользователи в каждой инструкции обслуживания
2. Содержание - индекс всех советов, касающихся Lennox Hearth ULC-S610, которое найдем в данном документе
3. Советы по использованию основных функций устройства Lennox Hearth ULC-S610 - которые должны облегчить нам первые шаги во время использования Lennox Hearth ULC-S610
4. Troubleshooting - систематизированный ряд действия, который поможет нам диагностировать а в дальнейшем очередность решения важнейших проблем Lennox Hearth ULC-S610
5. FAQ - чаще всего задаваемые вопросы
6. Контактные данные Информация о том, где искать контактные данные производителя / сервисного центра Lennox Hearth ULC-S610 в данной стране, если самостоятельно не получится решить проблему.

У вас вопрос, касающийся Lennox Hearth ULC-S610?

Воспользуйтесь формуляром, находящимся ниже

Если с помощью найденной инструкции Вы не решили свою проблему с Lennox Hearth ULC-S610, задайте вопрос, заполнив следующий формуляр. Если у какого то из пользователей была похожая проблема с Lennox Hearth ULC-S610 со всей вероятностью он захочет поделиться методом ее решения.

Перепишите текст с картинки

Комментарии (0)