    No .1 EN, SP Printed in China © 2008 Matsushita Electric W orks, Ltd. All Rights Reserved. Impreso en China For questions or assistance with your b lood pressure monitor , call us at 1-800-338-0552. P anasonic Consumer Electronics Compan y Division of P anasonic Corporation of North America One P anasonic W ay 1H-1 Secaucus , NJ 07094 35 2008/01/1 ...

  • Panasonic EW3153W - page 2

    1 English 2 English P anasonic Oscillometric Diagnostec™ Automatic Arm Blood Pressure Monitor Model EW3153 is a device intended to measure systolic and diastolic blood pressure and pulse rate of an adult individual b y using a pressurized cuff on the arm. The device is not intended for use on infants and children. The device is designed f or home ...

  • Panasonic EW3153W - page 3

    1 English 2 English P anasonic Oscillometric Diagnostec™ Automatic Arm Blood Pressure Monitor Model EW3153 is a device intended to measure systolic and diastolic blood pressure and pulse rate of an adult individual b y using a pressurized cuff on the arm. The device is not intended for use on infants and children. The de vice is designed for home ...

  • Panasonic EW3153W - page 4

    3 English 4 English Introduction Thank you f or purchasing the Panasonic A utomatic Arm Blood Pressure Monitor EW3153. Measuring your own b lood pressure is an impor tant wa y of monitoring your health. High blood pressure (h yper tension) is a major health problem which can be treated effectiv ely once detected. Measuring your blood pressure betwe ...

  • Panasonic EW3153W - page 5

    3 English 4 English Introduction Thank you f or purchasing the Panasonic A utomatic Arm Blood Pressure Monitor EW3153. Measuring your own b lood pressure is an impor tant wa y of monitoring your health. High blood pressure (h yper tension) is a major health problem which can be treated effectiv ely once detected. Measuring your blood pressure betwe ...

  • Panasonic EW3153W - page 6

    5 English 6 English 30 minutes prior to taking your b lood pressure. Blood pressure will be higher than usual: - when you are e xcited or tense - when you are taking a bath - during ex ercising or soon after e x ercising - when it is cold - within one hour after eating - after drinking coffee, tea or other be verages containing caff eine - after sm ...

  • Panasonic EW3153W - page 7

    5 English 6 English 30 minutes prior to taking your b lood pressure. Blood pressure will be higher than usual: - when you are e xcited or tense - when you are taking a bath - during ex ercising or soon after e x ercising - when it is cold - within one hour after eating - after drinking coffee, tea or other be verages containing caff eine - after sm ...

  • Panasonic EW3153W - page 8

    7 English 8 English Easily Chec k Y our Blood Pressure Readings Against the JNC 7* Classification 90 100 80 160 140 120 Stage 2 Hypertension SBP 165 DBP 105 Blood Pressure Categories e.g. : e.g. : e.g. : e.g. : Stage 1 Hypertension SBP 150 DBP 95 Prehypertension SBP 13 0 DBP 85 Normal SBP 1 1 5 DBP 75 Systolic Blood Pressure (SBP) Diastolic Blood P ...

  • Panasonic EW3153W - page 9

    7 English 8 English Easily Chec k Y our Blood Pressure Readings Against the JNC 7* Classification 90 100 80 160 140 120 Stage 2 Hypertension SBP 165 DBP 105 Blood Pressure Categories e.g. : e.g. : e.g. : e.g. : Stage 1 Hypertension SBP 150 DBP 95 Prehypertension SBP 13 0 DBP 85 Normal SBP 1 1 5 DBP 75 Systolic Blood Pressure (SBP) Diastolic Blood P ...

  • Panasonic EW3153W - page 10

    9 English 10 English Preparations Prior to T aking Measurements T o use this product, the power supplies are required for both the main unit and the wireless display . Main unit P ower supply Exclusive A C adapter (EW31555) (included) or 4 AA-size P anasonic LR6 batter ies Approximately 150 measurements can be taken. Depending on the conditions, ba ...

  • Panasonic EW3153W - page 11

    9 English 10 English Preparations Prior to T aking Measurements T o use this product, the power supplies are required for both the main unit and the wireless display . Main unit P ower supply Exclusive A C adapter (EW31555) (included) or 4 AA-size P anasonic LR6 batter ies Approximately 150 measurements can be taken. Depending on the conditions, ba ...

  • Panasonic EW3153W - page 12

    11 English 12 English When Using the Main Unit with Batteries *Alwa ys use alkaline batteries. (4 AA-size Panasonic LR6 alkaline batteries) When replacing batteries, alwa ys use 4 fresh alkaline batteries of the same type from the same manuf acturer , and replace them simultaneously . 1. T urn the main unit over and remove the battery cover b y sli ...

  • Panasonic EW3153W - page 13

    11 English 12 English When Using the Main Unit with Batteries *Alwa ys use alkaline batteries. (4 AA-size Panasonic LR6 alkaline batteries) When replacing batteries, alwa ys use 4 fresh alkaline batteries of the same type from the same manuf acturer , and replace them simultaneously . 1. T urn the main unit over and remove the battery cover b y sli ...

  • Panasonic EW3153W - page 14

    13 English 14 English Inserting the Batteries into the Wireless Display *Alwa ys use alkaline batteries. (2 AA-size LR6 alkaline batteries) When replacing batteries, alwa ys use 2 fresh alkaline batteries of the same type from the same manuf acturer , and replace them simultaneously . 1. T urn the wireless display over and remo ve the battery cover ...

  • Panasonic EW3153W - page 15

    13 English 14 English Inserting the Batteries into the Wireless Display *Alwa ys use alkaline batteries. (2 AA-size LR6 alkaline batteries) When replacing batteries, alwa ys use 2 fresh alkaline batteries of the same type from the same manuf acturer , and replace them simultaneously . 1. T urn the wireless display over and remo ve the battery cover ...

  • Panasonic EW3153W - page 16

    15 English 16 English T aking a Reading Advice: In general, blood pressure measurements are lo wer on the second attempt because you are calmer . For people who easily get tense, measuring twice each time is advised. When two measurements are taken, normally the smaller measurement is stored. When taking two measurements, alw a ys stay quiet f or 4 ...

  • Panasonic EW3153W - page 17

    15 English 16 English T aking a Reading Advice: In general, blood pressure measurements are lo wer on the second attempt because you are calmer . For people who easily get tense, measuring twice each time is advised. When two measurements are taken, normally the smaller measurement is stored. When taking two measurements, alw a ys stay quiet f or 4 ...

  • Panasonic EW3153W - page 18

    17 English 18 English T aking a Reading (continued) Do not take measurements. Within 1 hour of eating or drinking alcohol Immediately after drinking coffee or tea, or smoking In a moving v ehicle Immediately after ex ercising or taking a bath (W ait at least 20 minutes and tak e a measurement while staying quiet.) In cold places [T ake measurements ...

  • Panasonic EW3153W - page 19

    17 English 18 English T aking a Reading (continued) Do not take measurements. Within 1 hour of eating or drinking alcohol Immediately after drinking coffee or tea, or smoking In a moving v ehicle Immediately after ex ercising or taking a bath (W ait at least 20 minutes and tak e a measurement while staying quiet.) In cold places [T ake measurements ...

  • Panasonic EW3153W - page 20

    19 English 20 English T aking a Reading (continued) Measurement The hear t mark will blink when pulse is detected during pressurization. The pressure cuff will be tightened automatically . The entire display will light for appro x. 1 second. 1 Press the On/Off and Start button on the main unit. (1) After the entire display on the wireless displa y ...

  • Panasonic EW3153W - page 21

    19 English 20 English T aking a Reading (continued) Measurement The hear t mark will blink when pulse is detected during pressurization. The pressure cuff will be tightened automatically . The entire display will light for appro x. 1 second. 1 Press the On/Off and Start button on the main unit. (1) After the entire display on the wireless displa y ...

  • Panasonic EW3153W - page 22

    21 English 22 English T aking a Reading (continued) Irregular pulse function If the pulse r ate v aries by more than ±25% from the av erage while a measurement is being taken, when measurement is completed the mark will be display ed. The mark will be lit after approx. 6 seconds of blinking when the measurement is completed. If the mark is lit, pl ...

  • Panasonic EW3153W - page 23

    21 English 22 English T aking a Reading (continued) Irregular pulse function If the pulse r ate v aries by more than ±25% from the av erage while a measurement is being taken, when measurement is completed the mark will be display ed. The mark will be lit after approx. 6 seconds of blinking when the measurement is completed. If the mark is lit, pl ...

  • Panasonic EW3153W - page 24

    23 English 24 English T aking a Reading (continued) T o interrupt measurements quickl y Press the Quick air release b utton. If pressure cuff will not deflate quickly enough ev en if the On/Off and Star t button is pressed, press and hold the quick air release b utton on top of the unit. The air will be released in approximately 4 seconds . If the ...

  • Panasonic EW3153W - page 25

    23 English 24 English T aking a Reading (continued) T o interrupt measurements quickl y Press the Quick air release b utton. If pressure cuff will not deflate quickly enough ev en if the On/Off and Star t button is pressed, press and hold the quick air release b utton on top of the unit. The air will be released in approximately 4 seconds . If the ...

  • Panasonic EW3153W - page 26

    25 English 26 English Storing and Calling up Blood Pressure Readings (continued) Calling up readings from memory Readings can be recalled after being sav ed without having to s witch the unit on. (After approx. 2 seconds.) (After approx. 2 seconds.) (After approx. 2 seconds.) 1. Press the user selection button on the wireless display to select the ...

  • Panasonic EW3153W - page 27

    25 English 26 English Storing and Calling up Blood Pressure Readings (continued) Calling up readings from memory Readings can be recalled after being sav ed without having to s witch the unit on. (After approx. 2 seconds.) (After approx. 2 seconds.) (After approx. 2 seconds.) 1. Press the user selection button on the wireless display to select the ...

  • Panasonic EW3153W - page 28

    27 English 28 English Comparing AM and PM A verage Systolic Blood Pressure A ver age AM and PM systolic blood pressure is displa yed in order to allow you to compare readings from both time periods. Use of the AM and PM av erage systolic b lood pressure comparison function can aid in the detection of a blood pressure pattern known as “early mor n ...

  • Panasonic EW3153W - page 29

    27 English 28 English Comparing AM and PM A verage Systolic Blood Pressure A ver age AM and PM systolic blood pressure is displa yed in order to allow you to compare readings from both time periods. Use of the AM and PM av erage systolic b lood pressure comparison function can aid in the detection of a blood pressure pattern known as “early mor n ...

  • Panasonic EW3153W - page 30

    29 English 30 English Specifications P ower source DC 6 V (Main unit: F our AA/LR6 size alkaline batteries) AC 120 V 60 Hz (when using A C adapter) DC 3 V (Wireless display: T wo AA/LR6 size alkaline batteries) Display Digital LCD Method of measurement Oscillometric system Measurement range Blood pressure: 0 mmH g to 280 mmH g Pulse rate: 30 to 160 ...

  • Panasonic EW3153W - page 31

    29 English 30 English Specifications P ower source DC 6 V (Main unit: F our AA/LR6 size alkaline batteries) AC 120 V 60 Hz (when using A C adapter) DC 3 V (Wireless display: T wo AA/LR6 size alkaline batteries) Display Digital LCD Method of measurement Oscillometric system Measurement range Blood pressure: 0 mmH g to 280 mmH g Pulse rate: 30 to 160 ...

  • Panasonic EW3153W - page 32

    31 English 32 English Q & A (continued) Q Since the mark was displayed, I retried the measurement by setting m y arm on the unit properly . But the indicated value is still higher than usual. A The mark is just a guide f or the proper measurement method. (See page 20.) If you correct y our posture when the mar k is display ed but the measured v ...

  • Panasonic EW3153W - page 33

    31 English 32 English Q & A (continued) Q Since the mark was displayed, I retried the measurement by setting m y arm on the unit properly . But the indicated value is still higher than usual. A The mark is just a guide f or the proper measurement method. (See page 20.) If you correct y our posture when the mar k is display ed but the measured v ...

  • Panasonic EW3153W - page 34

    33 English 34 English T roubleshooting Display Status before err or Cause and solution is display ed. The indication disappears in the middle of the operation. (the or mark is display ed.) Batteries are exhausted. (See pages 11–13.) is display ed. Pressurization to more than 2 80 mmH g was perf ormed. Were measurements tak en according to the pro ...

  • Panasonic EW3153W - page 35

    33 English 34 English T roubleshooting Display Status before err or Cause and solution is display ed. The indication disappears in the middle of the operation. (the or mark is display ed.) Batteries are exhausted. (See pages 11–13.) is display ed. Pressurization to more than 2 80 mmH g was perf ormed. Were measurements tak en according to the pro ...

  • Panasonic EW3153W - page 36

    No .1 EN, SP Printed in China © 2008 Matsushita Electric W or ks, Ltd. All Rights Reser ved. Impreso en China For questions or assistance with your b lood pressure monitor , call us at 1-800-338-0552. P anasonic Consumer Electronics Compan y Division of P anasonic Corporation of North America One P anasonic W ay 1H-1 Secaucus , NJ 07094 35 2008/01 ...

Производитель Panasonic Категория Blood Pressure Monitor

Документы, которые мы получаем от производителя устройства Panasonic EW3153W мы можем разделить на несколько групп. Это в частности:
- технические чертежи Panasonic
- инструкции обслуживания EW3153W
- паспорта изделия Panasonic
- информационные брошюры
- энергетические этикетки Panasonic EW3153W
Все из них важны, однако самую важную информацию с точки зрения пользователя мы найдем в инструкции обслуживания Panasonic EW3153W.

Группа документов, определяемая как инструкции обслуживания, делится также на более подробные типы, такие как: Инструкции монтажа Panasonic EW3153W, инструкции обслуживания, короткие инструкции или инструкции пользователя Panasonic EW3153W. В зависимости от потребностей, Вам необходимо поискать требуемый документ. На нашем сайте Вы можете просмотреть самую популярную инструкцию использования изделия Panasonic EW3153W.

Похожие инструкции обслуживания

Полная инструкция обслуживания устройства Panasonic EW3153W, как должна выглядеть?
Инструкция обслуживания, определяемая также как пособие пользователя, или просто "руководство" - это технический документ, цель которого заключается в использовании Panasonic EW3153W пользователями. Инструкции пишет, как правило технический писатель, языком, доступным для всех пользователей Panasonic EW3153W.

Полная инструкция обслуживания Panasonic, должна заключать несколько основных элементов. Часть из них менее важная, как например: обложка / титульный лист или авторские страницы. Однако остальная часть, должна дать нам важную с точки зрения пользователя информацию.

1. Вступление и рекомендации, как пользоваться инструкцией Panasonic EW3153W - В начале каждой инструкции, необходимо найти указания, как пользоваться данным пособием. Здесь должна находится информация, касающаяся местонахождения содержания Panasonic EW3153W, FAQ и самых распространенных проблем - то есть мест, которые чаще всего ищут пользователи в каждой инструкции обслуживания
2. Содержание - индекс всех советов, касающихся Panasonic EW3153W, которое найдем в данном документе
3. Советы по использованию основных функций устройства Panasonic EW3153W - которые должны облегчить нам первые шаги во время использования Panasonic EW3153W
4. Troubleshooting - систематизированный ряд действия, который поможет нам диагностировать а в дальнейшем очередность решения важнейших проблем Panasonic EW3153W
5. FAQ - чаще всего задаваемые вопросы
6. Контактные данные Информация о том, где искать контактные данные производителя / сервисного центра Panasonic EW3153W в данной стране, если самостоятельно не получится решить проблему.

У вас вопрос, касающийся Panasonic EW3153W?

Воспользуйтесь формуляром, находящимся ниже

Если с помощью найденной инструкции Вы не решили свою проблему с Panasonic EW3153W, задайте вопрос, заполнив следующий формуляр. Если у какого то из пользователей была похожая проблема с Panasonic EW3153W со всей вероятностью он захочет поделиться методом ее решения.

Перепишите текст с картинки

Комментарии (0)