Инструкция обслуживания Ei Electronics Ei 205ENA

32 страниц 0.19 mb
Скачать

Перейти на страницу of 32

Summary
  • Ei Electronics Ei 205ENA - page 1

    Model Ei 204EN Model Ei 205EN Model Ei 205ENA Model Ei 205CEN - ST AND ARD - WITH MEMOR Y - WITH MEMOR Y & SEALED IN B A TTERIES - WITH MEMOR Y & INTERCONNECT Read and retain carefully f or as long as the product is being used. It contains vital inf or mation on the operation and installation. The leaflet should be regarded as par t of the ...

  • Ei Electronics Ei 205ENA - page 2

    3 4 5 10 15 19 21 22 24 26 28 28 30 1 2 3 4 5 6 7 8 9 10 11 12 13 READ THIS FIRST WHA T T O DO WHEN THE CO ALARM SOUNDS CARBON MONO XIDE - THE SILENT KILLER! WHERE T O PLA CE CARBON MONO XIDE ALARMS INST ALLA TION TESTING & MONIT ORING Y OUR CO ALARM MAINT AINANCE LIMIT A TIONS OF CARBON MONO XIDE ALARMS HO W T O PR O TECT Y OUR F AMIL Y TECHNI ...

  • Ei Electronics Ei 205ENA - page 3

    1. READ THIS FIRST P ower up the unit b y smoothly withdra wing the red “pull” tab at the top left hand cor ner of the unit. If the batteries are supplied separately install the three AA batteries by sliding the upper co v er off as shown in figure 5a page 15. The green, red & amber lights will immediately flash in sequence to show the y ar ...

  • Ei Electronics Ei 205ENA - page 4

    When the CO Alar m detects abnormal lev els of CO (abov e 50ppm CO) the red light star ts to flash immediately and the hor n will sound within 90 minutes . At higher le vels of CO the alarm will tur n on sooner (see tab le B - page 8). The CO Alar m will automatically reset once the CO has cleared. Pressing the test/hush b utton resets the CO Alar ...

  • Ei Electronics Ei 205ENA - page 5

    (5) Ring y our gas or other fuel supplier on their emergency number . K eep the number in a prominent place . (6) Do not re-enter the proper ty until the alar m has stopped. (If the alarm has been silenced b y pressing the test/hush button, wait at least 5 min utes so the alar m can chec k that the CO has cleared). (7) Do not use the fuel appliance ...

  • Ei Electronics Ei 205ENA - page 6

    High levels of CO in a house can be caused b y: • Incorrectly or poorly installed fuel-bur ning appliances . • Bloc ked or crac ked chimne ys/flues. • Bloc ked v ents or draught-proofing which mak es areas with fuel b ur ning appliances or fireplaces air tight. • Engines of cars, la wnmow ers etc. left running in confined spaces. • P or t ...

  • Ei Electronics Ei 205ENA - page 7

    Many cases of repor ted Carbon Mono xide poisoning indicate that while victims are a ware they are not w ell, they become so disorientated that they are unab le to sav e themselv es by either lea ving the building or calling f or assistance. Y oung children and household pets ma y be the first aff ected. T able A: Eff ects of Carbon Monoxide P oiso ...

  • Ei Electronics Ei 205ENA - page 8

    3.3 What happens when y our CO Alarm detects Carbon Monoxide ? When the Alar m detects potentally dangerous le v els of CO , it flashes the red alar m light immediately and then sounds a loud alar m if the CO persists . T ab le B below shows how the CO Alarm reacts to diff erent lev els of CO gas and e xposure time. At higher le vels of CO the alar ...

  • Ei Electronics Ei 205ENA - page 9

    NEVER IGNORE THE ALARM. Pre-Alarm: When the alar m detects o ver 50ppm CO the red light flashes e v er y 2 seconds. This helps locate CO leaks as the unit giv es an indication straight a wa y . (Without this f eature the CO le vel w ould need to be at 50ppm CO f or 90 minutes f or an indication to be giv en). Note the Pre-Alarm signal ma y be trigg ...

  • Ei Electronics Ei 205ENA - page 10

    Reset Memory by holding do wn the test button f or ov er 20 seconds until the red light stops flashing. Cov er the hor n with a cloth to muffle the alarm dur ing this time. Please note that the memor y will also be reset when the unit is unpo wered. 4. WHERE T O PLA CE CO ALARMS 4.1 Ideally a Carbon Mono xide Alar m should be installed in: - Ev er ...

  • Ei Electronics Ei 205ENA - page 11

    4.2 Unsuitable Locations Do not place the CO Alar m in an y of the follo wing areas. (1) In the immediate vicinity of a cooking appliance (k eep it at least 1 metre horizontally from it). (2) Outside the b uilding. (3) In an enclosed space (e.g. in or below a cupboard). (4) In a damp or humid area. (5) Directly abov e a sink or cook er . (6) Ne xt ...

  • Ei Electronics Ei 205ENA - page 12

    4.31 If locating the CO alarm in a r oom with a fuel b urning appliance (see figure 2) • If it is mounted on a wall, it should be located at a height g reater than the height of any door or windo w but still be at least 150mm from the ceiling. • If it is mounted on the ceiling it should be at least 300mm from any w all or light fitting. • The ...

  • Ei Electronics Ei 205ENA - page 13

    13 300mm 150mm 1 to 3 m 1 to 3 m DEAD AIR DON'T LOCA TE HERE CO Alarm Figure 2. Location in room with a fuel b ur ning appliance B15583/R0/204EN&205EN/U&C 8/6/06 1:54 PM Page 13 ...

  • Ei Electronics Ei 205ENA - page 14

    14 CO Alarm about 1 to 2m Figure 4. Location in bedrooms & other rooms remote from the appliance (i.e. at breathing le vel) 300mm CO Alarm Figure 3. Location in rooms with sloped ceilings, the CO alarm should be located at the high side of the room B15583/R0/204EN&205EN/U&C 8/6/06 1:54 PM Page 14 ...

  • Ei Electronics Ei 205ENA - page 15

    5. INST ALLA TION W ARNING: Do not use the CO Alar m on an intermittent basis, or as a por table detec- tor f or the spillage of combustion products from fuel b ur ning appliances or chimne ys. 5.1 INST ALLA TION PR OCEDURE Once y ou hav e selected a suitab le location, power up the unit b y smoothly withdra wing the red “PULL ” tab at the top ...

  • Ei Electronics Ei 205ENA - page 16

    Mark the position of the two mounting holes by using the unit as a template. Dr ill tw o holes using a 6mm drill for the plastic plugs supplied, (ensure y ou don’t drill into the house wir ing). Scre w the unit to the wall. Chec k that the CO Alar m can be heard in all the bedrooms. If not another CO Alar m should be located nearer the bedrooms. ...

  • Ei Electronics Ei 205ENA - page 17

    ( Note: The Ei205EN, Ei205ENA & Ei205CEN are supplied with 2 loc king r iv ets. Inser t the other loc king r iv et similar ly after remo ving the other post). 5.3 INTERCONNECTING (Model Ei205CEN only) Up to 12 Ei 205CEN Carbon Mono xide Alar ms can be interconnected so that when one senses CO , all alar m. This helps to ensure that the alar m w ...

  • Ei Electronics Ei 205ENA - page 18

    1. Slide off the batter y cov er as sho wn in Figure 5a. 2. On the first unit connect twin core cab le to the ter minals mar k ed 1 and 2 as shown in Figure 8 and bring the cab le out through the hole abov e the ter minal b lock. 3. If the y are being surf ace wired, break one of the three knoc kouts on the rear side wall. (W e do not recommend bri ...

  • Ei Electronics Ei 205ENA - page 19

    6. TESTING & MONIT ORING Y OUR CO ALARM Button T est It is recommended that y ou test your CO Alar m after installation and then once a w eek to mak e sure the unit is wor king. It will also help you and y our f amily to become f amiliar with the sound of the alar m. Press and hold the test b utton until the alar m sounds (it ma y take up to 5 ...

  • Ei Electronics Ei 205ENA - page 20

    (The batteries will usually last ov er 4 years in standb y under nor mal conditions. An undepleted batter y can po wer a unit in alarm for o ver 100 hours . The lif e will be reduced if the unit regularly goes into alar m or if it is e xposed to excessiv e temperatures f or long periods). Amber F ault Indicator If the unit beeps and the amber light ...

  • Ei Electronics Ei 205ENA - page 21

    How to distinguish between CO Alarm and Smoke Alarm warnings The CO Alar m has a distinctiv e on-off sound of 3 pulses, f ollow ed by a pause as compared with a typical Smok e Alar m which has a rapid pulsing sound. In addition, when y our CO Alar m detects CO the red light will be flashing. T esting both your CO Alarm and Smoke Alarms weekly will ...

  • Ei Electronics Ei 205ENA - page 22

    End of Life When the unit has completed up to 6 y ears of operation the amber light will flash e ver y 40 seconds. The entire unit must then be replaced. It must also be replaced when the date on the “Replace Unit b y” label on the side wall is e xceeded. When the batter y is depleted the unit will beep e v er y 45 seconds when the green light ...

  • Ei Electronics Ei 205ENA - page 23

    (2) Carbon Mono xide must enter the unit f or it to be detected. There ma y be Carbon Mono xide in other areas of the house (e.g. downstairs , in a closed room etc). but not in the vicinity of the CO Alar m. Doors, air dr aughts and obstr uctions can pre v ent the CO reaching the Alar m. F or these reasons we recommend. CO Alar ms are fitted both n ...

  • Ei Electronics Ei 205ENA - page 24

    Carbon Mono xide, b ut the response characteristics of these CO Alar ms are such that the y would not give sufficient w ar ning of fire. Smoke Alar ms m ust be fitted to give early warning of fire. The CO Alar m does not detect the presence of natural gas (methane), bottled gas (propane, butane) or other comb ustible gases . Fit combustion gas alar ...

  • Ei Electronics Ei 205ENA - page 25

    If any of these signs are present get the appliance chec ked out b y an e xper t bef ore fur ther use. If f amily members are ill get medical help . (2) Choose all appliances and v ehicles which burn fossil fuels such as coal, oil, natural/bottled gas , paraffin, wood, petrol, diesel, charcoal etc. with care and ha ve them prof essionally installed ...

  • Ei Electronics Ei 205ENA - page 26

    (9) Lea ving windows or doors slightly open (e ven a f ew inches) will significantly reduce the risk of high lev els of CO occurring. The high le vels of dr aught-proofing in moder n houses reduces v entilation and can allow dangerous gases to b uild up . (10) Install CO Alar ms in all the areas recommended in this leaflet. (11) Recognise that CO p ...

  • Ei Electronics Ei 205ENA - page 27

    T esting with CO : The red light flashes (as per T able B) within 10 seconds of unit detecting CO . Initialisation Time : 70 seconds. On power up red and amber lights flash momentarily to show the y are operational. Operating T emperature : -10°C to 40°C Humidity Range : 15% to 95% R.H. (non-condensing) A udible Alarm : 85dB(A) at 3m minimum Self ...

  • Ei Electronics Ei 205ENA - page 28

    End of Lif e Indication: Amber light flashes e very 45 seconds after 6 years to show the unit m ust be replaced. Dimensions : 135 x 105 x 71 mm. W eight : 260g. 11. GETTING THE CO ALARM SER VICED If y our CO Alar m f ails to wor k after y ou hav e carefully read all the instructions, chec k ed the unit has been installed correctly , and ensured tha ...

  • Ei Electronics Ei 205ENA - page 29

    These guarantees only apply to normal conditions of use and ser vice, and do not include damage resulting from accident, neglect, misuse, unauthorised dismantling, or contamination howsoe ver caused. These guarantees e xclude incidental and consequential damage. If the Carbon Monoxide Alarm should become defectiv e within the guarantee period, it m ...

  • Ei Electronics Ei 205ENA - page 30

    13. TR OUBLESHOO TING ALARM DOES NO T WORK WITH THE TEST BUTT ON: (1) Hold b utton down fir mly f or at least 5 seconds. (2) Chec k the ‘pull’ tag is remov ed and/or the batteries are correctly connected. (3) Replace batteries (if they are accessib le). ALARM BEEPS EVER Y 45 SECONDS: If the Alar m beeps e very 45 seconds and green light flashes ...

  • Ei Electronics Ei 205ENA - page 31

    (2) Ensure there are no fumes in the area (e.g. paint, thinners, hair spra y , chemical cleaners aerosol spra ys etc). (3) Ensure there is no outdoor source of CO in the vicinity (e.g. a car with engine running, heavy traffic , heavy air pollution, barbecue fumes etc). (4) Press the test/hush b utton to silence the alar m. If the unit continues to ...

  • Ei Electronics Ei 205ENA - page 32

    Ei Electr onics Shannon, Co . Clare, Ireland. T el: (061) 471277 F ax: (061) 471053 E-mail. helpdesk@eiltd.ie www .eielectronics.com Aico Ltd. Mile End Business P ark, Maesbur y Rd, Os westry , Shropshire, SY10 8NN, U .K. T el: 0870 7584000 F ax: 0870 7584010 E-mail: suppor t@aico .co .uk www .aico .co .uk © Ei Electronics 2005 P/N B15583 Re v 0 B ...

Производитель Ei Electronics Категория Smoke Alarm

Документы, которые мы получаем от производителя устройства Ei Electronics Ei 205ENA мы можем разделить на несколько групп. Это в частности:
- технические чертежи Ei Electronics
- инструкции обслуживания Ei 205ENA
- паспорта изделия Ei Electronics
- информационные брошюры
- энергетические этикетки Ei Electronics Ei 205ENA
Все из них важны, однако самую важную информацию с точки зрения пользователя мы найдем в инструкции обслуживания Ei Electronics Ei 205ENA.

Группа документов, определяемая как инструкции обслуживания, делится также на более подробные типы, такие как: Инструкции монтажа Ei Electronics Ei 205ENA, инструкции обслуживания, короткие инструкции или инструкции пользователя Ei Electronics Ei 205ENA. В зависимости от потребностей, Вам необходимо поискать требуемый документ. На нашем сайте Вы можете просмотреть самую популярную инструкцию использования изделия Ei Electronics Ei 205ENA.

Похожие инструкции обслуживания

Полная инструкция обслуживания устройства Ei Electronics Ei 205ENA, как должна выглядеть?
Инструкция обслуживания, определяемая также как пособие пользователя, или просто "руководство" - это технический документ, цель которого заключается в использовании Ei Electronics Ei 205ENA пользователями. Инструкции пишет, как правило технический писатель, языком, доступным для всех пользователей Ei Electronics Ei 205ENA.

Полная инструкция обслуживания Ei Electronics, должна заключать несколько основных элементов. Часть из них менее важная, как например: обложка / титульный лист или авторские страницы. Однако остальная часть, должна дать нам важную с точки зрения пользователя информацию.

1. Вступление и рекомендации, как пользоваться инструкцией Ei Electronics Ei 205ENA - В начале каждой инструкции, необходимо найти указания, как пользоваться данным пособием. Здесь должна находится информация, касающаяся местонахождения содержания Ei Electronics Ei 205ENA, FAQ и самых распространенных проблем - то есть мест, которые чаще всего ищут пользователи в каждой инструкции обслуживания
2. Содержание - индекс всех советов, касающихся Ei Electronics Ei 205ENA, которое найдем в данном документе
3. Советы по использованию основных функций устройства Ei Electronics Ei 205ENA - которые должны облегчить нам первые шаги во время использования Ei Electronics Ei 205ENA
4. Troubleshooting - систематизированный ряд действия, который поможет нам диагностировать а в дальнейшем очередность решения важнейших проблем Ei Electronics Ei 205ENA
5. FAQ - чаще всего задаваемые вопросы
6. Контактные данные Информация о том, где искать контактные данные производителя / сервисного центра Ei Electronics Ei 205ENA в данной стране, если самостоятельно не получится решить проблему.

У вас вопрос, касающийся Ei Electronics Ei 205ENA?

Воспользуйтесь формуляром, находящимся ниже

Если с помощью найденной инструкции Вы не решили свою проблему с Ei Electronics Ei 205ENA, задайте вопрос, заполнив следующий формуляр. Если у какого то из пользователей была похожая проблема с Ei Electronics Ei 205ENA со всей вероятностью он захочет поделиться методом ее решения.

Перепишите текст с картинки

Комментарии (0)