    VMC1 V ideo Security Intercom System f or the Home Rough - In Instructions USA & Canada (800) 421-1587 & (800) 392-0123 (760) 438-7000 - T oll Free F AX (800) 468-1340 www .linearcorp.com POWER BAND MEM ALARM DOWN UP 12 34 5 5 ME-UP + TUNER AUX MUSIC RADIO FIL TER GATE ST ATUS AUX OUTPUT 1 AUX OUTPUT 2 - + VOLUME AUX 1 AUX 2 INPUT FIL TER V ...

  • Linear VMC-1 - page 2

    Keep this manual in a safe place for future reference. T o replace this manual, download available from Linear W eb site:www .linearcorp.com Read Instructions - All saf ety and operating instructions should be read bef ore installing or operating the VMC1 Video Intercom system. Retain Instructions - The saf ety and operating instructions should be ...

  • Linear VMC-1 - page 3

    1 ✔ DO ensure that all instructions hav e been f ollowed bef ore power is applied to system. The installation shall be carried out in accordance with all applicable installation rules. ✔ DO use only Cat-5 & RG-6 and specifi ed wires called out in these instructions. The cable is designed and constructed with electrical specifi cations nec ...

  • Linear VMC-1 - page 4

    2 T able of Contents Block Dia gram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 Rough-in Kit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 Materials Required . . . . ...

  • Linear VMC-1 - page 5

    3 Block Diagram - + 1 VOLUME PRIV MON MUS CLEAR HOUSE DOOR AUX 23 4 5 6 7 AM ANTENNA FM ANTENNA MASTER ST A TION TE6D PO WER SUPPL Y H628 D A T A HUB ROOM ST A TION DOOR ST A TION DEDICA TED POWER VIDEO DOOR ST A TION DOOR LOCK - + 1 VOLUME PRIV MON MUS CLEAR HOUSE DOOR AUX 23 4 5 6 7 - + 1 VOLUME PRIV MON MUS CLEAR HOUSE DOOR AUX 23 4 5 6 7 - + 1 ...

  • Linear VMC-1 - page 6

    4 Introduction VMC1MB TE6D 101093 226804 250106-2 233103 The VMC1H installation rough-in prepares the home to accommodate the video intercom system. A VMC1MB mounting brac ket is necessary for the Master Station. Room stations and the Alloy Color V ideo Door Station (VMC1VDS) can be mounted directly onto fi nished walls. All other door stations re ...

  • Linear VMC-1 - page 7

    5 Materials Required T ools Most are required for purposes of this installation, but may vary according to installer preferences. PO WER DRILL WITH 1” A UGER WIRE STRIPPERS/CUTTER T APE MEASURE PHILLIPS SCREWDRIVER 14/18 GA UGE WIRE 110 PUNCH-DO WN T OOL CA T -5 CABLE DR YW ALL SA W HAMMER LEVEL 0-M 0.5 10 50 200 500 50 250 10 50 250 600 + - MOUN ...

  • Linear VMC-1 - page 8

    6 Overview The VMC1 S ystem Designed for installation in new homes, the VMC1 is a Whole House Color Video Security Intercom system that pro vides room to room communication, multiple camera support, basic home automation controls, and video security for mid to large residential applications. VMC1 provide years of service and security for the homeow ...

  • Linear VMC-1 - page 9

    7 Wiring Information Cables and Wir ing Excellent locations to run cables include: • Roof space • False ceilings/ bulkhead area • Through and/or around external walls • Under fl oor s (subject to access being available) • Underground in conduit ✓ NO TE: K eep Intercom cab les far from any A C wiring. Av oid running intercom cab le in p ...

  • Linear VMC-1 - page 10

    8 Master Station Rough-In VMC1MB Master Station Mounting Br ack et The VMC1MB mounts fl ush with the wall stud and holds the Master Station and P ower Supply (See Figure 1). Position the VMC1MB at a suggested height of 4-1/2 to 5-1/2 feet from the fl oor to center of the unit. As all wiring from other stations is generally terminated at the rear ...

  • Linear VMC-1 - page 11

    9 Master Station Rough-In VMC1MB Installation - Finished W all Cut out an opening in the drywall (Height 7 -1/4” x Width 1 1”) but do not cut right up against the w all stud. Allow 5/8” clearance between drywall opening and stud. This ensures that drywall will o verlap bracket (See Figure 2). Slide the VMC1MB vertically , then turn cloc kwise ...

  • Linear VMC-1 - page 12

    10 Room Station Rough-In Room Station Mounting The Room Stations are normally mounted at a height from the fl oor of: 4-1/2’ to 5’ . The Room Stations are not designed to be installed outdoors. Room Station Installation - Unfi nished W all For an unfi nished wall it is recommended that the VMC1HR rough-in enclosure be used. Identify the loca ...

  • Linear VMC-1 - page 13

    11 Door Station Rough-In VMC1VDS Door Station Rough-in The VMC1VDS is a metal door station with a 90 degree horizontal viewing area. It is normally mounted at a height from the fl oor of: 55” – 60” . When installing the VMC1VDS be aware of the camera location and the direction of sunlight and other ambient light. Direct sun or lighting into ...

  • Linear VMC-1 - page 14

    12 VMC1VDS-S/BZ Door Station Rough-in The VMC1VDS-S and VMC1VDS-BZ incorporate a wide angle 120 degree horiz ontal viewing camera into a Door Station. It is normally mounted at a height from the fl oor of: 55” – 60” . Installation of this unit on an exterior wall requires 4 screws and anc hors (See Figure 6). When installing these units, be ...

  • Linear VMC-1 - page 15

    13 Po wer Supply Rough-In TE6D P ow er Supply The P ower Supply unit is pre-wired and self contained, and the wires are tuc ked inside. T o access connection wires, open the P ower Supply unit by removing four screws as shown in Figure 6. In the unlikely case that the TE6D electrical connectors become unplugged, the 3-pin and 6-pin connector bloc k ...

  • Linear VMC-1 - page 16

    14 Po wer Supply Rough-In Figure 7 - TE6D P ower Supply Wiring P ow er Supply Wir ing 1. R un a 14 AWG 120 V AC power cable (including ground) from a dedicated 15-amp circuit breaker to the Master Station Mounting Brac ket location. The VMC1 requires a dedicated power source so there’ s no interference from other equipment. 2. R oute incoming pow ...

  • Linear VMC-1 - page 17

    15 Data Hub Wiring TIA-568A WIRING ST ANDARD D A T A HUB RJ-45 MODULAR PLUG Cat-5 WIRE COLOR Pin 1 White/Green Pin 2 Green Pin 3 White/Orange Pin 4 Blue Pin 5 White/Blue Pin 6 Orange Pin 7 White/Brown Pin 8 Brown Figure 8. H628 Data Hub Wiring H628 D ata Hub The H628 Data Hub is used to connect eac h station to the Master Station. Pull Wir es Pull ...

  • Linear VMC-1 - page 18

    16 Antenna Installation Radio Antennas VMC1 requires two antennas, one for AM and one for FM reception. The AM antenna is a 25-foot wire the FM antenna is a 25-foot length of coax with a “T” shaped wire dipole at one end that attac hes between rafters in the attic. Antenna arrangement is crucial to quality radio reception. AM and FM antennas sh ...

  • Linear VMC-1 - page 19

    17 Auxiliary Output Rough-In Figure 10. Electric Door Strike Wiring Chime Activ ated Control Output Rough-In The Chime Activated Control Output allows for any number of security related automation functions including 1 0 available door c himes. T o connect an auxiliary Chime refer to Figure 1 0. Refer to the hook-up instructions supplied with the c ...

  • Linear VMC-1 - page 20

    18 Appendix A – A vailable Components System Master Station with 5.6” TFT LED color screen suppor ting up to 20 remote stations. P oint-to-P oint, P oint-to-Group and All Call intercom with hands free response. UL 60950 cer tifi ed VMC1 (White pictured) VMC1-BK (Black) VMC1-BZ (Bronze) Color Video Door Station with 10 diff erent door chimes, 9 ...

  • Linear VMC-1 - page 21

    19 Ple xiglas weather shield increases the weather resistance of VMC1VDS to IP31 Smoke Color (VDSWS-T) Appendix A – A vailable Components Ple xiglas weather shield increases the weather resistance of VMC1VDS-BZ/S to IP31 Clear (DSWS) Nightstand station. Provides all of the function of the intercom f or use on a nightstand or desk Black (VMC1TTS) ...

  • Linear VMC-1 - page 22

    20 Appendix A – A vailable Components Model H275 Univ ersal Brack et for Data Hub Installation Indoor Bo x Color Camera (left) & Color Video Cameras w/nite vision (r ight) (ML TL2DN49IR) Rough in kit f or the VMC1 Master . Includes mounting frame , TE6D pow er supply , FM Dipole antenna, AM antenna wire and installation hardware (VMC1H) Metal ...

  • Linear VMC-1 - page 23

    21 Miniature door / window tr ansmitter (DXS-32) 2-Channel Receiv er (DXR-702) 12V Control Output s witched 110V outlets for lights and other “notifi cation” devices Remote T ur n On for Lights A C1 (1 outlet) AC3 (2 outlets) MFG: Xantec/Niles Wire Rela y The 284 Leaded Accessor y Rela y is a 5 amp F or m C relay with wire leads pre-attached. ...

  • Linear VMC-1 - page 24

    2 - Y ear Limited Warr anty Linear LLC war rants these products to be free of defects for 2 years. The warranty period begins on either (a) the date of purc hase or installation date of this product or (b) the date of closing on a new residence in whic h this product was originally installed. The war ranty extends to the original user of the produc ...

Производитель Linear Категория Intercom System

Документы, которые мы получаем от производителя устройства Linear VMC-1 мы можем разделить на несколько групп. Это в частности:
- технические чертежи Linear
- инструкции обслуживания VMC-1
- паспорта изделия Linear
- информационные брошюры
- энергетические этикетки Linear VMC-1
Все из них важны, однако самую важную информацию с точки зрения пользователя мы найдем в инструкции обслуживания Linear VMC-1.

Группа документов, определяемая как инструкции обслуживания, делится также на более подробные типы, такие как: Инструкции монтажа Linear VMC-1, инструкции обслуживания, короткие инструкции или инструкции пользователя Linear VMC-1. В зависимости от потребностей, Вам необходимо поискать требуемый документ. На нашем сайте Вы можете просмотреть самую популярную инструкцию использования изделия Linear VMC-1.

Похожие инструкции обслуживания

Полная инструкция обслуживания устройства Linear VMC-1, как должна выглядеть?
Инструкция обслуживания, определяемая также как пособие пользователя, или просто "руководство" - это технический документ, цель которого заключается в использовании Linear VMC-1 пользователями. Инструкции пишет, как правило технический писатель, языком, доступным для всех пользователей Linear VMC-1.

Полная инструкция обслуживания Linear, должна заключать несколько основных элементов. Часть из них менее важная, как например: обложка / титульный лист или авторские страницы. Однако остальная часть, должна дать нам важную с точки зрения пользователя информацию.

1. Вступление и рекомендации, как пользоваться инструкцией Linear VMC-1 - В начале каждой инструкции, необходимо найти указания, как пользоваться данным пособием. Здесь должна находится информация, касающаяся местонахождения содержания Linear VMC-1, FAQ и самых распространенных проблем - то есть мест, которые чаще всего ищут пользователи в каждой инструкции обслуживания
2. Содержание - индекс всех советов, касающихся Linear VMC-1, которое найдем в данном документе
3. Советы по использованию основных функций устройства Linear VMC-1 - которые должны облегчить нам первые шаги во время использования Linear VMC-1
4. Troubleshooting - систематизированный ряд действия, который поможет нам диагностировать а в дальнейшем очередность решения важнейших проблем Linear VMC-1
5. FAQ - чаще всего задаваемые вопросы
6. Контактные данные Информация о том, где искать контактные данные производителя / сервисного центра Linear VMC-1 в данной стране, если самостоятельно не получится решить проблему.

У вас вопрос, касающийся Linear VMC-1?

Воспользуйтесь формуляром, находящимся ниже

Если с помощью найденной инструкции Вы не решили свою проблему с Linear VMC-1, задайте вопрос, заполнив следующий формуляр. Если у какого то из пользователей была похожая проблема с Linear VMC-1 со всей вероятностью он захочет поделиться методом ее решения.

Перепишите текст с картинки

Комментарии (0)