    T ereScope700 and T er eScope800 Wireless Optical Communication Links Models TS700/100, T S700/155, T S 700/G, T S 800/155 User Man ual ...

  • MRV Communications TS700/100 - page 2

    WIRELESS OPTICAL COMMUNICA TIONS User Manual Docum ent Nu mber ML 48237 (4703700), Rev. 4.0 February 2006  MRV Communications, Inc . Web site: www. mrv.c om ...

  • MRV Communications TS700/100 - page 3

    MR V Co mm unica tions , In c. – Inst allat ion Ma nual Table of Contents STANDARDS Standards Compliance ............................................................................ i FCC Notice ............................................................................................... i CE Mark ............................................... ...

  • MRV Communications TS700/100 - page 4

    MR V Co mm unica tions , In c. – Inst allat ion Ma nual Data/Signal Cabling .............................................................................. 24 For TS700/155, TS700/G, TS800/155, TS800/155-F ............................24 For TS700/100.........................................................................................25 CHAP TE ...

  • MRV Communications TS700/100 - page 5

    MR V Co mm unica tions , In c. – Inst allat ion Ma nual i Standards Standards Compliance UL 1950; CSA 22.2 No 950; FCC Part 15 C lass B; CE-89/336/EEC, 73/ 23/ EEC FCC Notice WARNING : This eq u ipment has been tested and found to com ply with the lim its for a Class B digital device, pursuant t o Part 15 of t he FCC Rules. These limits are d esi ...

  • MRV Communications TS700/100 - page 6

    MR V Co mm unica tions , In c. – Inst allat ion Ma nual ii Other St andard s 1. CISPR 22: 1993 AS/NZS 3548: 1995, Class B Joint Amendment No. 1: 1997, Joint Amendment No. 2: 1997 2. EN 60950+A1+A2+A3+A4+A11 ACA TS001-1997 AS/NZS 3260: 1993 A4: 1997 3. ITU G.703, G.704, G.706,G.736, G.737, G.738, G739, G740, G.775, G.823. MRV     Laser ...

  • MRV Communications TS700/100 - page 7

    MR V Co mm unica tions , In c. – Inst allat ion Ma nual iii About this User Manual Audience This manual is intended for the user who wishes to install, operate, manage and troubleshoot the TereScope700 and TereScope800. Qualifications Users of this guide are expected to have: • Working knowledge of Electro-optical equipment • Working knowledg ...

  • MRV Communications TS700/100 - page 8

    MR V Co mm unica tions , In c. – Inst allat ion Ma nual iv Safety Requirements All requirements stipulated in the safety laws of the country of ins tallation must be abided by when installing the TereScopes . Caution! In addition, ensure that the requirements noted in this chapter are met in order to reduce risk of electrical shock and fire and t ...

  • MRV Communications TS700/100 - page 9

    MR V Co mm unica tions , In c. – Inst allat ion Ma nual v casual passersby. Examples of restricted locations are: sides of buildings at sufficient heights, restricted rooftops, and telephone poles. This definition of a restricted location is in accordance with the proposed IEC 60825-I Part 12 requirements. • Avoid using controls, adjustments, o ...

  • MRV Communications TS700/100 - page 10

    MR V Co mm unica tions , In c. – Inst allat ion Ma nual vi Introduction CAREFULL Y READ THE ENTIRE MANU AL BEFORE INST ALLING n InfraRed (IR) link allows connection without any cable between two distant sites. For that, two identical transceivers, each installed on one site and aligned to face each other, provide point-to-point connectivity. This ...

  • MRV Communications TS700/100 - page 11

    MR V Co mm unica tions , In c. – Inst allat ion Ma nual 1 The Product Caution! W hen handling the T ereScope, tak e special care not to dam age the poly carbonate window! Models Table 1: Models of the TereScope 1 Models Part Num ber Description TS700/100 TS100/A/FET/VS TereScope700 for Fast Ethernet 100Base-T X connectivity up to a distance of 36 ...

  • MRV Communications TS700/100 - page 12

    MR V Co mm unica tions , In c. – Inst allat ion Ma nual 2 S (for SingleMode) ‘U’ represents operating wavelength. Instead of U use one of the following: 8 (for 850 nm) 3 (for 1310 nm) 5 (for 1550 nm) ‘W’ represents connector type. Instead of W use one of the following: C (for SC) T (for ST) ‘FET’ (Fast ether net) represents 100B ase-T ...

  • MRV Communications TS700/100 - page 13

    MR V Co mm unica tions , In c. – Inst allat ion Ma nual 3 HI G H VOL T . LO W VOL T . MRV Swi tch Ip Address Fas t Eth er n e t Posi tion Data Rat e UP Nor ma l DO WN Loc al Loopback 1 23 Mode of Def au l t IP AT M OC3 E3 T3 4,5 4 5 Nor ma l Ali gn men t - 4,5 - 4 5 TX RX TE LESCO PE TORQUE VALU E 7 Lb-I nch L G N +/~ -/~ USE COPP ER CO NDUC T OR ...

  • MRV Communications TS700/100 - page 14

    MR V Co mm unica tions , In c. – Inst allat ion Ma nual 4 Back Panel Description Table 2: TS700/155 Standard Model Back Panel Controls, Interfaces, and Indicators Air RX Flag LED Green LED indicates data received by th e Airlink receiver. Turns ON at the t hreshol d level. Air RX Sync L ED Yello w LED. Turn s ON if th e rate of th e received Data ...

  • MRV Communications TS700/100 - page 15

    MR V Co mm unica tions , In c. – Inst allat ion Ma nual 5 B. TS800/155 Standard Model The TS800/155 supports most of the prevalent protocols in the 34-155 Mbps range. Support for a special protocol, which is not on the list, can be ordered after coordination with the factory. This model can be used for Open Protocol applications which ensures com ...

  • MRV Communications TS700/100 - page 16

    MR V Co mm unica tions , In c. – Inst allat ion Ma nual 6 Note: Pins (4,5) and (7,8) of the management RJ45 connector can be used for dry contact purposes, fo r Airlink flag and F/O f lag alarms res pectively. Selectors (DIP Swit ch DS1 Toggles) -- shown in Figure 1.3and 1.4 Data Rate (Toggles 1,2,3,4) S e t the transmission rate of the transceiv ...

  • MRV Communications TS700/100 - page 17

    MR V Co mm unica tions , In c. – Inst allat ion Ma nual 7 Air RX Flag LED Green LED indicates data received by th e Airlink receiver. Turns ON at the t hreshol d level. Air RX Sync L ED Yello w LED. Turn s ON if th e rate of th e received Data matche s the Data Rate se t on the Data Rate DIP switch. F/O Main, RX Flag LED Up per green LE D indicat ...

  • MRV Communications TS700/100 - page 18

    MR V Co mm unica tions , In c. – Inst allat ion Ma nual 8 C. TS800/155-F (Standard Model including Fusion option) This special T S800/155-F model can be connected to the back-up radio system without a special MRV switch and card supporting Fusion. This TereScope can be connected to any switch (supporting 10/100 Mbps data rate) via a standard conv ...

  • MRV Communications TS700/100 - page 19

    MR V Co mm unica tions , In c. – Inst allat ion Ma nual 9 That’s what happens when the air channel is interrupted. F/O Network RF T ransce i ver 10/100TX- 100FX Media Converter Switch 10/100 Base-T MC 10 Base-T STP F/O Mai n TS TS IR = 100 Mbps Network Mai n RF T ransce i ver RF = 2-10 Mbps F/O F/O 10 Base-T STP Redundant Redundant Figure 1.5a: ...

  • MRV Communications TS700/100 - page 20

    MR V Co mm unica tions , In c. – Inst allat ion Ma nual 10 Fusion Maximizing Link Availability in All Weather Conditions. The TereScope Fus ion was designed to combine the best features of two transport mediums, l aser light and ra dio waves, to form a single, seaml ess, wireless communication link between network devices . By leveraging both tec ...

  • MRV Communications TS700/100 - page 21

    MR V Co mm unica tions , In c. – Inst allat ion Ma nual 11 D. TS700/100 - Fast-Ethernet System Figure 1.6: TS700/100 Model Back Panel Back Panel Description Table 4: TS700/100 Back Panel Controls, Interfaces, and Indicators Power Power sourc e Terminal Block (Main or UPS) AC power supp ly (100 to 240 Vac) or DC power supply (24 to 60 Vdc). 100Bas ...

  • MRV Communications TS700/100 - page 22

    MR V Co mm unica tions , In c. – Inst allat ion Ma nual 12 Air RX Link LED Green LE D indicates signal received by the A irlink receiver. Turns ON at the t hreshol d level. Air RX Data LED Yellow LED blinking indic ates Data transfer via the Ai rlink receiver to the int erface. TP RX Link LE D Green LE D indicates Link est ablish ed at the 100Bas ...

  • MRV Communications TS700/100 - page 23

    MR V Co mm unica tions , In c. – Inst allat ion Ma nual 13 E. TS700/G - Gigabit-Ethernet System The TereScope 700/G supports Gigabit Ethernet and FiberChannel protocols. The physical design and configuration of the TS700/G is similar to the other members of the series, and its operational principles are essentially the same. However, The T S700/G ...

  • MRV Communications TS700/100 - page 24

    MR V Co mm unica tions , In c. – Inst allat ion Ma nual 14 Air RX Flag LED Green LED indicates s ignal recei ved by the Ai rlink receiver. Turns ON at the t hreshol d level. Laser En abled LED Red L ED. Turns ON to indicate tha t la se r in enabled to transmit light. F/O RX Flag LED Green LED indicates Data received by t he Fiber Optic receiver. ...

  • MRV Communications TS700/100 - page 25

    MR V Co mm unica tions , In c. – Inst allat ion Ma nual 15 Monitoring and Management options 1 – Management 2 - Dry contact (Only TS800) 3 – RSM (Only TS800) The T S is ma nagea ble by us ing SNMP option. SNMP monitor ing can be perf ormed via Me gaVision, MRV’s SNMP software. The T S can be connecte d to dry contact box (RSM-DC). The RSM-D ...

  • MRV Communications TS700/100 - page 26

    MR V Co mm unica tions , In c. – Inst allat ion Ma nual 16 Typical Connection 1 - Fiber Connection In order to implement a connection, each transceiver must be connected to the peripheral/testing equipment through fiber optic cables. A correct connection is indicated by the display on the back panel of the trans ceiver (see the section Display a ...

  • MRV Communications TS700/100 - page 27

    MR V Co mm unica tions , In c. – Inst allat ion Ma nual 17 Site Survey The first ste p before every install ation is to visit the sites to be linked. in order to make sure that the connection is feasible, to find out potential obstacles or difficulties and to decide on the location and mounting points of the t ransceivers. Line of Sig ht A necess ...

  • MRV Communications TS700/100 - page 28

    MR V Co mm unica tions , In c. – Inst allat ion Ma nual 18 Prefer Avoid Pay attention to Concrete Parapet Structural wall or column Old constructions Soft material (asphalt, etc.) Non-uniform surfaces Wooden and metal structur es Colored windows Double glazing The proximity of powe r radio antennas For reasons of conven ience, it is always p refe ...

  • MRV Communications TS700/100 - page 29

    MR V Co mm unica tions , In c. – Inst allat ion Ma nual 19 Figure 2.1: Optimal Mounting Figure 2.2: Acceptable Mounting Figure 2.3 shows an unrecommended TereScope link location because of interference by I R. Notice that the TereScopes are mounted far from the rooftop edges or are too close to the g round. Figure 2.3: Unrecommended Mounting Tere ...

  • MRV Communications TS700/100 - page 30

    MR V Co mm unica tions , In c. – Inst allat ion Ma nual 20 Figure 2.4 shows an unacceptable TereScope link location because of interf erence by passing vehicles. Notice that the TereScopes are mounted far from the rooftop edges and not high enough above the ground. Figure 2.4: Unacceptable Mounting Mounting Environment & Stability 1. When dec ...

  • MRV Communications TS700/100 - page 31

    MR V Co mm unica tions , In c. – Inst allat ion Ma nual 21 Note: If the only option to mount the TereScope is at points 5, 6 or 7, it has to be mounted at least 2 m above the rooftop to avoid roof scintillations and people crossing the link beam (If pos sible, avoid placing the TereScope on a mast). 3. Avoid surfaces with high reflectivity (e.g., ...

  • MRV Communications TS700/100 - page 32

    MR V Co mm unica tions , In c. – Inst allat ion Ma nual 22 Figure 2.8: Wall Mounting (usi ng JMP and JMB) Figure 2.9: Wall Pedestal Mounting (using JMP and MO54C) Figure 2.10: Extended Wall Mounting (usi ng JMP and MO62C) Figure 2.11: Angle Bracket Mounting (using JMP and M001) Transmitting through a Window 1. Determine the number of surfaces the ...

  • MRV Communications TS700/100 - page 33

    MR V Co mm unica tions , In c. – Inst allat ion Ma nual 23 Figure 2.12 shows the arrangement for transmitting through a window Figure 2.12: Arrangement for transmitti ng through a window. ...

  • MRV Communications TS700/100 - page 34

    MR V Co mm unica tions , In c. – Inst allat ion Ma nual 24 Infrastructure The only infrastructure required for operating the transceiv er and linking the sites is Pow er and Data/Signal connection to the peripheral netw orking equipment. This must be ready prior to the airlink installation . IN OUTDOOR INSTALLATIONS, USE SHIELDED AND WEATHERPROOF ...

  • MRV Communications TS700/100 - page 35

    MR V Co mm unica tions , In c. – Inst allat ion Ma nual 25 A simple power loss test can inform us about the condition of the fibers. This tes t consists in measuring (with an optical power meter) the output power at one end of the tested fiber when a fiber s ource is connected at the other end. If the values are in dB m, the difference between th ...

  • MRV Communications TS700/100 - page 36

    MR V Co mm unica tions , In c. – Inst allat ion Ma nual 26 Bench T est It is alw ay s easier and more convenient to locat e a failure and solv e a problem in a lab on a bench than on a roof under bad conditions. A ccordingly , it is strongly recommended to perform a bench test with all the modules prior to installation in order to check the equip ...

  • MRV Communications TS700/100 - page 37

    MR V Co mm unica tions , In c. – Inst allat ion Ma nual 27 Table 6: DIP Switch Setting for TereS cope TS700/155 T S800/155 Function OFF ON OFF ON Fast Ethernet 4,5 – 1,2,3,4 – ATM/OC3/ STM1: 155 Mbps – 4,5 2,3,4 1 SMPTE 143 Mbps – 3,4 1,2 E3:34.368 Mbps 5 4 1,2,4 3 T3:44.736 4 5 2,4 1,3 OC1/S TMO:51.840 Mbps – 1,4 2,3 Cus tom ized 1 – ...

  • MRV Communications TS700/100 - page 38

    MR V Co mm unica tions , In c. – Inst allat ion Ma nual 28 3 – TS700/G Compatibility Peripheral equipment Check the operation of the peripheral equipment connected with cables (see Configuration 1 below). Interf aces Check the specifications compatibility (type, data r ate) between the TereScope and the peripheral equipment interfaces . Test eq ...

  • MRV Communications TS700/100 - page 39

    MR V Co mm unica tions , In c. – Inst allat ion Ma nual 29 Or F/O Cable Or F/O Cable Configu ratio n 3: (Ap plica ble to all m odels) UWIN RX TX UWIN RX TX IR link BER Tester TX RX Configu ratio n 4: (Ap plica ble to all m odels) Peripheral Equipment UWIN RX TX TX RX Peripheral Equipment UWIN RX TX TX RX IR link Workstation Workstation Configu ra ...

  • MRV Communications TS700/100 - page 40

    MR V Co mm unica tions , In c. – Inst allat ion Ma nual 30 2. Received power 100 < OPTICAL P OWER < 1000 Expected Results The BER must be less than 10E -12 (10 -12 ) for on-g oing tests and error-free for short tests. 2 . TS700/100 Proper Display 2. Indicators I ndicator → AI R RX 100baseT Position ↓ Flag TX Flag T X Alignment Loopback ...

  • MRV Communications TS700/100 - page 41

    MR V Co mm unica tions , In c. – Inst allat ion Ma nual 31 Figure 5.1a: JMP-L Installation This chapter show s how to mount the TereScope and and accessories at the site ( see A ppendix D for the required mat erial). See Unpacking Instructions in Appendix C . CAUTION : TereScope must be mounted in the horizontal position only; max angle 45 o Acce ...

  • MRV Communications TS700/100 - page 42

    MR V Co mm unica tions , In c. – Inst allat ion Ma nual 32 Fi g . 5.3a: Rear door fix a tion Fi g . 5.3b: Rear door fixed Figure 5.2: TereScope Parts – External view Table 9: TereScope Parts Part Description Part Description A Scre w for Grounding H(x5) Door lock Captive Screws B Right-Lef t Fine Alignment Scr ews I Door Axis C Up-Down Fine Ali ...

  • MRV Communications TS700/100 - page 43

    MR V Co mm unica tions , In c. – Inst allat ion Ma nual 33 Fi g . 5.4: Mountin g kit Fi g . 5.5: Mountin g kit – To p view Fi g . 5.6: Mountin g kit – Back view Fi g . 5.7: Mountin g kit – Side view Fi g ures 5.7a – 5.7b: Mountin g kit – detailed views Fi g . 5.8a Fi g . 5.8b Fi g . 5.8c AIMING HEAD ADJUSTMENT AND LOCKS: B: Right-Left ( ...

  • MRV Communications TS700/100 - page 44

    MR V Co mm unica tions , In c. – Inst allat ion Ma nual 34 The Installer Tool Kit (JITK-L) The JITK-L tool kit includes the work tools required for opening and closing nuts and screws of the TereScope for optimal installation. It is recommended that these tools be used. MRV supplies this tool kit with each TereScope head. In addition to the tool ...

  • MRV Communications TS700/100 - page 45

    MR V Co mm unica tions , In c. – Inst allat ion Ma nual 35 2- Mounting the accessories ) Horizontal surfaces (parapet, ...): Figure 5.11: TereScope Detached from the Aimi ng Head G2 (x2) JMP-L Aiming Head Figure 5.12: Aim ing Head Cradle for TereSc ope Head CAUTION! Do not loosen Screws M (x8). F2 (x2) N: Gr ounding screw on T S T here are three ...

  • MRV Communications TS700/100 - page 46

    MR V Co mm unica tions , In c. – Inst allat ion Ma nual 36 THE J MP-L SHOULD BE ORIENT ED IN SUCH A W AY THAT THE GROUNDING SCREW IS LOCATED ON THE BAC K (CLOS E TO THE INS TALLER) AND THE FRONT FACING THE OPPOSITE SI TE. ) Vertical surfaces (wall, rectangular column, ...): No t e For more convenience it is suggested to as semble the 3 parts of t ...

  • MRV Communications TS700/100 - page 47

    MR V Co mm unica tions , In c. – Inst allat ion Ma nual 37 To use the floor, a very stable tower standing on the floor is required. The transceiver will be fixed on the top of the tower. Two techniques using a small concrete block are suggested for stabilizing the tower on the floor. • The concrete slab material is poured directly on the base o ...

  • MRV Communications TS700/100 - page 48

    MR V Co mm unica tions , In c. – Inst allat ion Ma nual 38 No t e The Tower M ount and the Clamping Plate are not provided with the equipment and should be supplied by the installer. 3- Attachment of the Transceiver (TereScope Head) After securely attaching JMP-L to the mounting surface choose one of the three possible directions for installation ...

  • MRV Communications TS700/100 - page 49

    MR V Co mm unica tions , In c. – Inst allat ion Ma nual 39 1 – Make sure that t he power cable is disconnected from the electr ical power source. 2 – Undo the five screws H -- see Figure 6.1. Holding the Rear Door, Pull the door, turn it clockwise ¼ of a turn around the axis (I), so that a s crew will be opposite hole ”O”. Fixe the door ...

  • MRV Communications TS700/100 - page 50

    MR V Co mm unica tions , In c. – Inst allat ion Ma nual 40 Fi g . 6.8a and 6.8b: Screws for coarse ali g nment Transceiver Alignment General Point-to-point connections require face-to-face orientation of both transceiving ends of the link. With wireless optical links, the beam spot should be positioned symmetrically on the remote r eceiver, as ac ...

  • MRV Communications TS700/100 - page 51

    MR V Co mm unica tions , In c. – Inst allat ion Ma nual 41 Fi g . 6.9: Telesco p e crosshair on the o pp osite TereSco p e 2. While looking (see fig 6.9 below) through the telescope, rotate and tilt the TereScope to bring the telescope crosshairs on the left side (your right side) of the opposite TereScope. 3. Tighten firml y 4 Bolts K and D in s ...

  • MRV Communications TS700/100 - page 52

    MR V Co mm unica tions , In c. – Inst allat ion Ma nual 42 Fine Alignment Vertical Motion Screws – Two screws (‘C’). Used for fine rotation of the TereScope in the vertical plane. Fine Alignment Horizontal Motion Screws – Two scre ws (‘B’). Used for fine rotation of the TereScope in the horizontal plane.. Note # Two installe rs are re ...

  • MRV Communications TS700/100 - page 53

    MR V Co mm unica tions , In c. – Inst allat ion Ma nual 43 Fi g . 6.15a and 6.15b: Al i g nm ent screws Repeat this process for the vertical positioning (middle of segment [V1,V2]). H1 H2 V1 V2 Once the position is reached, tighten firmly the 4 Fine Locking Screws (2xF2, 2xF1 and G1). Repeat this procedure interchanging roles with the second inst ...

  • MRV Communications TS700/100 - page 54

    MR V Co mm unica tions , In c. – Inst allat ion Ma nual 44 Captive Screws H Link Oper ating Test Set back the Mode Select Dip-Switch on the Normal position (the Alignment indicator should switch OFF (if exists depending on the model)). At both sites, connect with fiberoptic or STP cables coming from the peripheral equipment to the fiberoptic or c ...

  • MRV Communications TS700/100 - page 55

    MR V Co mm unica tions , In c. – Inst allat ion Ma nual 45 Fig. 6.17: Mounted TereScope – Left View Fig. 6.18: Mounted TereScope – Back View Fig. 6.19: Mounted TereScope – Front View ...

  • MRV Communications TS700/100 - page 56

    MR V Co mm unica tions , In c. – Inst allat ion Ma nual 46 Maintenance Periodic V isits Periodic visits (every three/six months, depending on the installation environment) should be planned for: • Checking the display • Checking the mounting • Cleaning the optical aperture of the trans ceivers • Cleaning the building windows for indoors i ...

  • MRV Communications TS700/100 - page 57

    MR V Co mm unica tions , In c. – Inst allat ion Ma nual 47 Product Specifications ) high speed Light ( 700/155 TS Part Number Model TS155/A/YUW / VS TS700/155 A pplication / Data Protocol T3, E3, Fas t Ethernet and ATM Performa nce Rate 1-155 Mbps Range (1) @ 3dB/km 880 m @ 5dB/km 770 m @ 10dB/km 600 m @ 17dB/km 480 m @ 30dB/km 360 m Minimum Rang ...

  • MRV Communications TS700/100 - page 58

    MR V Co mm unica tions , In c. – Inst allat ion Ma nual 48 TS700/100 (Fast-Ethernet Light) Part Number Model TS100/A/FET /VS TS700/100 A pplication / Data Protocol Fast Ethernet Performa nce Rate 100 Mbps Range (1) @ 3dB/km 880 m @ 5dB/km 770 m @ 10dB/km 600 m @ 17dB/km 480 m @ 30dB/km 360 m Minimum Range 10 m Bit Error Ra te Less than 1E-12 ( un ...

  • MRV Communications TS700/100 - page 59

    MR V Co mm unica tions , In c. – Inst allat ion Ma nual 49 TS800/155 (high speed Light) Part Number Model TS155/C2/YUW /VS or T S155/C2/YUW /FS TS800/155 or T S800/155-F A pplication / Data Protocol Fast Ethernet, AT M, OC3,ST M1, SMPTE, E3, T3, O C1/STM0 & Open Protocol Performa nce Rate 1-155 Mbps Range (1) @ 3dB/km 1900 m @ 5dB/km 1600 m @ ...

  • MRV Communications TS700/100 - page 60

    MR V Co mm unica tions , In c. – Inst allat ion Ma nual 50 TS700/G (Giga-Light) Part Number Model TS1000/A/YUW / VS TS700/G A pplication / Data Protocol Gigabit-Ethernet, Fiber Channel Performa nce Rate 1.0625Gbps & 1.25 Gbps Range (1) @ 3dB/km 1000 m @ 5dB/km 900 m @ 10dB/km 690 m @ 17dB/km 540 m @ 30dB/km 400 m Minimum Range 40 m Bit Error ...

  • MRV Communications TS700/100 - page 61

    MR V Co mm unica tions , In c. – Inst allat ion Ma nual 51 Digital Readout vs. Distance These tables ar e only intended to give you an idea of what digital r eadout you could expect according to the distance to link. D= Distance [m] R= Reading (Digital readout) D 50 100 150 200 250 300 350 400 450 500 550 600 650 700 R 560 520 420 360 300 240 180 ...

  • MRV Communications TS700/100 - page 62

    MR V Co mm unica tions , In c. – Inst allat ion Ma nual 52 Unpacking Instructions for TereScope The TereSc ope is shipped pre-assembl ed. See fig.C 2 1. Unpack all the accessori es. 2. .Before mounting, in order to make installation on the mounting surface easier, the JMP-L mus t first be detached and connected to the fixation surface. To detach ...

  • MRV Communications TS700/100 - page 63

    MR V Co mm unica tions , In c. – Inst allat ion Ma nual 53 Tool Kit, Equipment, and Materials TOOLS 1. Elec tric drill (im pact for masonr y ), reversible, with speed control and 0- 13mm chuck 2. Dr ills set High Speed Steel (HSS) 3- 13mm . 3. Conc rete carbide .bit drills 6,8,9 and 10mm (regular and long shank ). 4. Adj ustable (cres cent) wrenc ...

  • MRV Communications TS700/100 - page 64

    MR V Co mm unica tions , In c. – Inst allat ion Ma nual 54 A LIST OF THE TOOL S SUPP LIED BY MRV COMMUNICATIONS WITH EVERY T ereScope HEAD Description Qty Where to use a. WRENCH #8 for Aiming Head, (M5 nut) 1 N: Grounding screw on TereScope (see page 29) (Also for rear door axe : I) b BALLDRIVE R L, WRENCH 5mm for Allen Screw M6 1 F1 and F2: Scre ...

  • MRV Communications TS700/100 - page 65

    MR V Co mm unica tions , In c. – Inst allat ion Ma nual 55 TereScopes Bench Test Procedure Introduction All TS Products are bench tested indoors prior to outdoor installation to ensure that the syst em is fully functional. The bench test is a simple procedure whereby a link pair is aligned on the table and activated to simulate a channel of commu ...

  • MRV Communications TS700/100 - page 66

    MR V Co mm unica tions , In c. – Inst allat ion Ma nual 56 allows for testing each transmitter separately. By rota ting the devices 45 degrees, the next pair of transmitters is tested. Hence, testing all 8 transmitters in the link pair requires only 4 rotations. In the 8” setup, the two devices ar e not centrally aligned; instead, only one corn ...

  • MRV Communications TS700/100 - page 67

    MR V Co mm unica tions , In c. – Inst allat ion Ma nual 57 Figure E.3: Acti ve Transmitters (Sho wn Darkened). Figure E.2b : Bench Te st setup drawing for 10” TS model. Note that one d evice is higher tha n the other and shifte d over to the sid e so that only o ne transm itter from each device is facing opposite the other device’s receiver. ...

  • MRV Communications TS700/100 - page 68

    ...

  • MRV Communications TS700/100 - page 69

    MR V Co mm unica tions , In c. – Inst allat ion Ma nual 59 Ef fect of Wind on T erescopes I ntroduction The outdoor environment in which our devices are nor mally placed exposes the link to wind pressur es that may affect the accuracy of the link’ s alignment. Several f actors play a role in the deter mination of the extent to which the dir ect ...

  • MRV Communications TS700/100 - page 70

    MR V Co mm unica tions , In c. – Inst allat ion Ma nual 60 Appendix G FSO Chaining What is Chaining? The Chaining of FSO is required when the two sites are connected by more than one link using at least one additional building as a mid-point. When is the Chaining required? The Chaining of FSO links is required in the following cases: a) When t he ...

  • MRV Communications TS700/100 - page 71

    MR V Co mm unica tions , In c. – Inst allat ion Ma nual 61 Indirect Chaining Direct Chaining Chaining Limits The number of links that can be chained is limited due to the Jitter parameter. Sensitivity to jitter is different for every protocol and can var y with different manufacturers. T he typical number is 3- 4 chained links. If more chains are ...

  • MRV Communications TS700/100 - page 72

    MR V Co mm unica tions , In c. – Inst allat ion Ma nual 62 FSO products & Chaining Product series Chaining No of chained links TS155-PS (34-155 Mbps) Direct 3-4 TS 34 (Open Protocol, 1-34 Mbps) Indirect 3-4 TS 10 (Ethernet) Direct 3-4 TS Mux (Mux 4E1, 4T1) Direct No Limits* TS 2 (E1, T1) Direct No Limits* *No Limits – it refers to Networkin ...

  • MRV Communications TS700/100 - page 73

    MR V Co mm unica tions , In c. – Inst allat ion Ma nual 63 APPENDIX H Installation Log D.1. Client / Dealer details Customer Dealer Company Name Address City Country Contact Person Tel Fax e-mail D.2. Application details Ty pe of network E1 , Ethernet , Token Ring , Fast Ethernet , FDDI , ATM , Other (S pecify ) Product Evaluated distance by cust ...

  • MRV Communications TS700/100 - page 74

    MR V Co mm unica tions , In c. – Inst allat ion Ma nual 64 D.4. Site survey Done by Customer representati ve Distance Date Site A Site B Location Floor Orientation (NSEW) I nstallation site sche me I ndoor / Outdoor Plate J MP / Bracket JMB Window attenuation On-line UPS Voltage required (110V / 230V) Ground earthing Radio antenna field Associate ...

  • MRV Communications TS700/100 - page 75

    MR V Co mm unica tions , In c. – Inst allat ion Ma nual 65 D.5. Installation Done by Customer representati ve Date Site A Site B Sy stem model Serial number L ocation : Same as site survey , if not provide details Accessories : Same as site survey , if not provide details Digital readout Telescope c alibration : if cannot , sketch the telescope v ...

  • MRV Communications TS700/100 - page 76

    MR V Co mm unica tions , In c. – Inst allat ion Ma nual 66 D.6. System failure Visit made by Customer representati ve Date Site A Site B Sketch of telescope view Digital readout Failure detail Action items Visit made by Customer representati ve Date Site A Site B Sketch of telescope view Digital readout Failure detail Action items ...

  • MRV Communications TS700/100 - page 77

    MR V Co mm unica tions , In c. – Inst allat ion Ma nual 67 APPENDIX I Power over Ethernet The Power-over-Ethernet (PoE) option is available only for Low Voltage TereScope model 700/100 . PoE eliminates a separate DC power s upply cable at each Access P oint (AP) location, i.e., it allows f or a single Ethernet cable providing both data and power ...

Производитель MRV Communications Категория Network Card

Документы, которые мы получаем от производителя устройства MRV Communications TS700/100 мы можем разделить на несколько групп. Это в частности:
- технические чертежи MRV Communications
- инструкции обслуживания TS700/100
- паспорта изделия MRV Communications
- информационные брошюры
- энергетические этикетки MRV Communications TS700/100
Все из них важны, однако самую важную информацию с точки зрения пользователя мы найдем в инструкции обслуживания MRV Communications TS700/100.

Группа документов, определяемая как инструкции обслуживания, делится также на более подробные типы, такие как: Инструкции монтажа MRV Communications TS700/100, инструкции обслуживания, короткие инструкции или инструкции пользователя MRV Communications TS700/100. В зависимости от потребностей, Вам необходимо поискать требуемый документ. На нашем сайте Вы можете просмотреть самую популярную инструкцию использования изделия MRV Communications TS700/100.

Похожие инструкции обслуживания

Полная инструкция обслуживания устройства MRV Communications TS700/100, как должна выглядеть?
Инструкция обслуживания, определяемая также как пособие пользователя, или просто "руководство" - это технический документ, цель которого заключается в использовании MRV Communications TS700/100 пользователями. Инструкции пишет, как правило технический писатель, языком, доступным для всех пользователей MRV Communications TS700/100.

Полная инструкция обслуживания MRV Communications, должна заключать несколько основных элементов. Часть из них менее важная, как например: обложка / титульный лист или авторские страницы. Однако остальная часть, должна дать нам важную с точки зрения пользователя информацию.

1. Вступление и рекомендации, как пользоваться инструкцией MRV Communications TS700/100 - В начале каждой инструкции, необходимо найти указания, как пользоваться данным пособием. Здесь должна находится информация, касающаяся местонахождения содержания MRV Communications TS700/100, FAQ и самых распространенных проблем - то есть мест, которые чаще всего ищут пользователи в каждой инструкции обслуживания
2. Содержание - индекс всех советов, касающихся MRV Communications TS700/100, которое найдем в данном документе
3. Советы по использованию основных функций устройства MRV Communications TS700/100 - которые должны облегчить нам первые шаги во время использования MRV Communications TS700/100
4. Troubleshooting - систематизированный ряд действия, который поможет нам диагностировать а в дальнейшем очередность решения важнейших проблем MRV Communications TS700/100
5. FAQ - чаще всего задаваемые вопросы
6. Контактные данные Информация о том, где искать контактные данные производителя / сервисного центра MRV Communications TS700/100 в данной стране, если самостоятельно не получится решить проблему.

У вас вопрос, касающийся MRV Communications TS700/100?

Воспользуйтесь формуляром, находящимся ниже

Если с помощью найденной инструкции Вы не решили свою проблему с MRV Communications TS700/100, задайте вопрос, заполнив следующий формуляр. Если у какого то из пользователей была похожая проблема с MRV Communications TS700/100 со всей вероятностью он захочет поделиться методом ее решения.

Перепишите текст с картинки

Комментарии (0)