    Marshall E lectronics NCB-1004 Network Contr ol Box for IMD M onitors Operating Instr uctions ...

  • Marshall Electronics Network Control Box for IMD Monitors NCB-1004 - page 2

    ...

  • Marshall Electronics Network Control Box for IMD Monitors NCB-1004 - page 3

    3 3 Contents Product Ov erview .............................................................. ....................................................................... ............................. 4 Features ....................................................................... ....................................................................... ...

  • Marshall Electronics Network Control Box for IMD Monitors NCB-1004 - page 4

    4 Product Over view The NCB-10 04 Net work Control box is a com prehensiv e remote c ontrol solutio n for Mars hall’s IMD (In- Monitor Display) line of m onitors. T he NCB-1004 of fers complete contr ol of each monitor's menu settings and adj ustm ents such as contrast, col or, curtain c olor, as pect ratio, and more. T he NCB-10 04 can cont ...

  • Marshall Electronics Network Control Box for IMD Monitors NCB-1004 - page 5

    5 Install ation and Power- On ■ Unpacking Carefull y unpack the NC B-1004 and verif y that the f ollowing i tems are included: • NCB-1004 Network Control Box • V-PS12-5V-1 Power S uppl y with 2-Pin T wist Lock Connector • Operating Instructions Inspect the u nit for an y phys ical dam age that ma y have occurred d uring shi pping. Shoul d t ...

  • Marshall Electronics Network Control Box for IMD Monitors NCB-1004 - page 6

    6 Front and Rear Panel Features RS-422 Out puts The RS-422 outputs sen d MEI pr otocol com mands to Marshal l’s IMD line of monitor s. Each out put has exactly the s am e signal. Up to 1 28 screens c an be connected to each outp ut. T hese output ports a lso pass Im age Video or T SL v4.0 pro tocol com mands from the Control Input, embedded i n t ...

  • Marshall Electronics Network Control Box for IMD Monitors NCB-1004 - page 7

    7 Connecting to the NCB-1004 Overview The NCB-10 04 can be operated b y any com puter with a web bro wser, via a T CP/IP net work connec tion. No a dditional software is needed. T he NCB-10 04 ma y be connecte d directl y to a singl e com puter, or connec ted to a l ocal area net work and acces sed by mult iple com puters . The NCB-100 4 is shipped ...

  • Marshall Electronics Network Control Box for IMD Monitors NCB-1004 - page 8

    8 Connecti ng to t he NCB-100 4 (conti nued) Connecting the NCB-1004 to a Single Computer (cont inued) 8. Click O K in the Intern et Prot ocol (T CP/IP) Propertie s window, an d then cl ick Close i n the Local Area Connection Propertie s windo w. 9. Open an y web browser application (Internet Explorer, Firefox , etc.) 10. Enter the address http://1 ...

  • Marshall Electronics Network Control Box for IMD Monitors NCB-1004 - page 9

    9 Connecti ng to t he NCB-100 4 (conti nued) Connecting the NCB-1004 to a Local A rea Netw ork If the networ k portion of the unit’s IP addres s (firs t three number s) matc hes your network , the NCB- 1004 can be connected to a local ar ea net work and acc essed fr om any com puter on th e network . The unit’s I P address m ust also be availab ...

  • Marshall Electronics Network Control Box for IMD Monitors NCB-1004 - page 10

    10 Changing t he IP Address of the NCB-1004 Overview The NCB-10 04 is ship ped with a d efault IP addr ess of 192. 168.0.233 . T his IP a ddress can be chang ed via t he network connection. Note that t he existing IP add ress must be known to make th is change. If the existin g IP ad dress is unknown , please cont act Marsh all Electron ics for a s ...

  • Marshall Electronics Network Control Box for IMD Monitors NCB-1004 - page 11

    11 Changing t he IP Address o f the NCB-1004 ( cont inued) Procedure (continued) 5. At the pass word prom pt shown bel ow, do not e nter a password a nd sim ply click O K : 6. Then, the fol lowing com m and line interfac e should app ear: 7. T y pe the follo wing com mand at the com m and prom pt, and press enter : vi /etc/network/interfaces ...

  • Marshall Electronics Network Control Box for IMD Monitors NCB-1004 - page 12

    12 Changing t he IP Address o f the NCB-1004 ( cont inued) Procedure (continued) 8. The f ollowing file inf ormation s hould appear : 9. This f ile must be edited t o save the new IP ad dress. Us e the followin g comm ands to ed it the file. Ed it only the numbers. Do not pres s the enter key after each co mmand. To move the cursor , use arr ow key ...

  • Marshall Electronics Network Control Box for IMD Monitors NCB-1004 - page 13

    13 System C onfiguration Overview The NCB-10 04 can be used in thr ee diff erent system configurat ions. The f ollowing di agram s show the dif ferent configurat ions: Basic Remote Control of IMD Monito rs ■ Overview Use the follo wing conf iguration for basic r emote c ontrol of Mars hall IMD ser ies m onitors. T his setup a llows re mote contro ...

  • Marshall Electronics Network Control Box for IMD Monitors NCB-1004 - page 14

    14 System Co nfigu ration (conti nued) Remote Control with Image Video Pass-Through ■ Overview Use the follo wing conf iguration for basic r emote c ontrol of Mars hall IMD ser ies m onitors, whi le also pas sing thr ough Image Video pr otoco l. This setup a llows rem ote control of the IMD m onitor, and p ass -through of Im age Video text and ta ...

  • Marshall Electronics Network Control Box for IMD Monitors NCB-1004 - page 15

    15 System Co nfigu ration (conti nued) Remote Control with TSL Pass-Through ■ Overview Use the follo wing conf iguration for basic r emote c ontrol of Mars hall IMD ser ies m onitors, whi le also pas sing thr ough TSL v4.0 prot ocol. This s etup allo ws rem ote control of the IMD m onitor along with pass- through of TSL text a nd tally comm ands ...

  • Marshall Electronics Network Control Box for IMD Monitors NCB-1004 - page 16

    16 Web Int erface Overview The web inter face is use d to op erate the NC B-1004. O nce the NCB-100 4 is conne cted to a net work, acc ess the web interface b y entering the units IP address in any web b rowser on a ny com puter on the network . The web interfac e allows rem ote control of all o n-screen m enu featur es of ind ividual m onitors or ...

  • Marshall Electronics Network Control Box for IMD Monitors NCB-1004 - page 17

    17 Web Inter face ( continued) Window Management The W indow Managem ent page is shown b elow: Use the butt ons and m enus sho wn above for th e follo wing settings : o As pect Ratio ( 4:3, Scaled 4:3, 16:9, Centered 16:9 / Fu ll Screen) o O n-Screen Mar kers (Aspect Rat io and Safe Ar ea Mark ers) o C enter Mark er o Mar ker Bac kground o C urtain ...

  • Marshall Electronics Network Control Box for IMD Monitors NCB-1004 - page 18

    18 Web Inter face ( continued) Preset Configuration The Preset Co nfigurat ion page is shown be low: Use the butt ons shown a bove to l oad and s ave prese ts in each m onitor. Note that thes e controls af fect the pr esets in each m onitor onl y. There are no presets in th e NCB-10 04 itself. o Load (Load pres ets Us er1 – User 6, or Factor y De ...

  • Marshall Electronics Network Control Box for IMD Monitors NCB-1004 - page 19

    19 Web Inter face ( continued) OSD Configuration & IMD The OSD Conf igurat ion & IMD page is sho wn below: Use the first s ection of the OSD & IMD pag e to set th e protoco l pass-th rough s ettings : o Set Protoco l (Image V ideo, T SL) – Select th e protoc ol type to be passed thr ough the NCB- 1004. No te that this option m ust be ...

  • Marshall Electronics Network Control Box for IMD Monitors NCB-1004 - page 20

    20 Web Inter face ( continued) S y stem The System page is s hown bel ow: Use the butt ons shown a bove to s end the f ollowing co mm ands: o Ping (Healt hy, Unhe althy) – T est a comm and and respons e with a m onitor. o Get Softw are Version – Reads th e m ain software ver sion of a m onitor. o Get Protocol Version – Reads th e protocol ver ...

  • Marshall Electronics Network Control Box for IMD Monitors NCB-1004 - page 21

    21 Web Inter face ( continued) Table of Web Interface Commands Aspect Rat io 4:3, Scaled 4:3, 16:9, 16:9 Center ed Set Marker Off, On Window Managemen t Set Center Off, On Set Backgroun d Transparent, 50% Gray, Black Set Curtain Color Blue, Red, Green, White, Black Men u Controls Menu, Select, Up, Dow n, F1, F2 Power Color Increase Value, Decrease ...

  • Marshall Electronics Network Control Box for IMD Monitors NCB-1004 - page 22

    22 Specifications ■ CONT ROL INPUT Connector 1 x RJ12 (Modular 6 P6C) Ph y sical Layer RS-422 Data Protoco ls Image Video: Start Bits 1 Data Bits 7 Parity Even Stop Bits 1 Baud Rate 3840 0 TSL v4.0 Protoc ol: Start Bits 1 Data Bits 8 Parity Even Stop Bits 1 Baud Rate 3840 0 Pinout ■ MONITO R OUT PUTS Connectors 4 x RJ12 (Modular 6 P6C) Ph y sic ...

  • Marshall Electronics Network Control Box for IMD Monitors NCB-1004 - page 23

    Specifica tions (cont inued) Warrant y Marshall El ectronics warranties to th e first c onsum er that this NCB- 1004 LCD m onitor will, under norm al use, be f ree fr om defects in workm anship and m aterials, when recei ved in its origin al container, for a peri od of one year f rom the purchas e date. T his warrant y is extended t o the firs t co ...

  • Marshall Electronics Network Control Box for IMD Monitors NCB-1004 - page 24

    Marshall Electr onics, Inc . 1910 East Maple Ave. El Segundo, CA 90245 Tel: (800) 800-6608 / (310) 333-0606 • Fax : 310-333-0688 www.LCDRacks.com • sales@lcd racks.com ...

Производитель Marshall Electronics Категория Network Card

Документы, которые мы получаем от производителя устройства Marshall Electronics Network Control Box for IMD Monitors NCB-1004 мы можем разделить на несколько групп. Это в частности:
- технические чертежи Marshall Electronics
- инструкции обслуживания Network Control Box for IMD Monitors NCB-1004
- паспорта изделия Marshall Electronics
- информационные брошюры
- энергетические этикетки Marshall Electronics Network Control Box for IMD Monitors NCB-1004
Все из них важны, однако самую важную информацию с точки зрения пользователя мы найдем в инструкции обслуживания Marshall Electronics Network Control Box for IMD Monitors NCB-1004.

Группа документов, определяемая как инструкции обслуживания, делится также на более подробные типы, такие как: Инструкции монтажа Marshall Electronics Network Control Box for IMD Monitors NCB-1004, инструкции обслуживания, короткие инструкции или инструкции пользователя Marshall Electronics Network Control Box for IMD Monitors NCB-1004. В зависимости от потребностей, Вам необходимо поискать требуемый документ. На нашем сайте Вы можете просмотреть самую популярную инструкцию использования изделия Marshall Electronics Network Control Box for IMD Monitors NCB-1004.

Похожие инструкции обслуживания

Полная инструкция обслуживания устройства Marshall Electronics Network Control Box for IMD Monitors NCB-1004, как должна выглядеть?
Инструкция обслуживания, определяемая также как пособие пользователя, или просто "руководство" - это технический документ, цель которого заключается в использовании Marshall Electronics Network Control Box for IMD Monitors NCB-1004 пользователями. Инструкции пишет, как правило технический писатель, языком, доступным для всех пользователей Marshall Electronics Network Control Box for IMD Monitors NCB-1004.

Полная инструкция обслуживания Marshall Electronics, должна заключать несколько основных элементов. Часть из них менее важная, как например: обложка / титульный лист или авторские страницы. Однако остальная часть, должна дать нам важную с точки зрения пользователя информацию.

1. Вступление и рекомендации, как пользоваться инструкцией Marshall Electronics Network Control Box for IMD Monitors NCB-1004 - В начале каждой инструкции, необходимо найти указания, как пользоваться данным пособием. Здесь должна находится информация, касающаяся местонахождения содержания Marshall Electronics Network Control Box for IMD Monitors NCB-1004, FAQ и самых распространенных проблем - то есть мест, которые чаще всего ищут пользователи в каждой инструкции обслуживания
2. Содержание - индекс всех советов, касающихся Marshall Electronics Network Control Box for IMD Monitors NCB-1004, которое найдем в данном документе
3. Советы по использованию основных функций устройства Marshall Electronics Network Control Box for IMD Monitors NCB-1004 - которые должны облегчить нам первые шаги во время использования Marshall Electronics Network Control Box for IMD Monitors NCB-1004
4. Troubleshooting - систематизированный ряд действия, который поможет нам диагностировать а в дальнейшем очередность решения важнейших проблем Marshall Electronics Network Control Box for IMD Monitors NCB-1004
5. FAQ - чаще всего задаваемые вопросы
6. Контактные данные Информация о том, где искать контактные данные производителя / сервисного центра Marshall Electronics Network Control Box for IMD Monitors NCB-1004 в данной стране, если самостоятельно не получится решить проблему.

У вас вопрос, касающийся Marshall Electronics Network Control Box for IMD Monitors NCB-1004?

Воспользуйтесь формуляром, находящимся ниже

Если с помощью найденной инструкции Вы не решили свою проблему с Marshall Electronics Network Control Box for IMD Monitors NCB-1004, задайте вопрос, заполнив следующий формуляр. Если у какого то из пользователей была похожая проблема с Marshall Electronics Network Control Box for IMD Monitors NCB-1004 со всей вероятностью он захочет поделиться методом ее решения.

Перепишите текст с картинки

Комментарии (0)