    H200 & H200HF SERIES W A TER CONDITIONERS Apartment Buildings Boiler W ater T reatment Car W ashes Commercial Buildings Condominiums Factories Hospitals Laundries Mobile Home Parks Motels and Hotels Nursing and Rest Homes Ofce Buildings Restaurants Schools For Commer cial & Industrial Applications H200 T op Mount H200 Side Mount H200HF S ...

  • Argosy Research H200 Series - page 2

    Hellenbrand Means Quality and Reliability Since 1967, Hellenbrand, Inc. has provided water solutions to the water tr eatment industry in the U.S. and around the world. Our gr owth in the water tr eatment industry is a direct r esult of pro- viding high quality products and supporting the applications for those pr oducts with over 200+ years of indu ...

  • Argosy Research H200 Series - page 3

    • Solid state micropr ocessor can control fr om one to four units allowing you system add on capabilities as your needs grow . • Regeneration may be initiated with a time clock, meter delayed or meter immediate. • Up to nine fully programmable cycle times, that can be moved around and r epeated in various orders for your particular applicatio ...

  • Argosy Research H200 Series - page 4

    H200/H200HF Diagnostic and Histor y Screens provide the water treatment operator with a wealth of information. Diagnostic Screens • Days since last regeneration • T otal volume treated since last regeneration • Reserve history for the current day and previous six-days • Usage history by the hour for each of the last 63 days • Maximum o ...

  • Argosy Research H200 Series - page 5

    H200/H200HF Diagnostic and Histor y Screens provide the water treatment operator with a wealth of information. DIAGNOSTIC 5 DIAGNOSTIC 6 DIAGNOSTIC 7 DIAGNOSTIC 7-B WS2H Control V alve Manual Page 21 Diagnostic Screens (continued) DIAGNOSTICS 5 Maximum fl ow rate for the last 28 days. Max fl ow rate of the day DIAGNOSTICS 5-B Hourly history of ma ...

  • Argosy Research H200 Series - page 6

    H200/H200HF Diagnostic and Histor y Screens provide the water treatment operator with a wealth of information. HISTOR Y 1 HISTOR Y 2 HISTOR Y 3 Page 22 WS2H Control V alve Manual V alve History Returns to normal operation after 5 minutes. Accessed by pressing UP and DOWN simultaneously for >3 seconds, then by pressing UP and DOWN simultaneously ...

  • Argosy Research H200 Series - page 7

    Modes of Regeneration Time Clock - 7 or 28 day calendar clock shall initiate regeneration at a pr e-set time of day . Parallel Individual Meters - All units are in service at the same time with either delayed or immediate r e- generation. A lockout feature or of fsetting time of regeneration pr events more than one unit to r egenerate at a time. Un ...

  • Argosy Research H200 Series - page 8

    A . MINERAL T ANK: Fiberglass tank with Polyethylene Inner Shell and Fiberglass Roving Manufactured to Operate at 150 psi. NSF Approved. B. DISTRIBUTOR SYSTEM: T wo-Inch Hub & Lateral Dis - tributor for Maximum Service Flow and Minimal Pressure Loss. C. MINERAL: High Capacity Ion Exchange Resin. Uniform and stable beads assure long life, high s ...

  • Argosy Research H200 Series - page 9

    Brine T ank(s) Inlet Bypass V alve Brine T ank(s) Outlet Isolation V alves Flex Connectors MA V V alve H200 T win/T riple x/Fourple x Installation T op-Mount - First-in, Last-Out Piping Arrangement. H200 Single Installation - Side Mount Brine T ank Inlet Outlet Bypass V alve Isolation V alves Sidemount Adapter Base Brine Line 1" MNPT 2” FNPT ...

  • Argosy Research H200 Series - page 10

    H200 T win Alternating - Side Mount H200 T win/T riple x/Fourple x Installation - Side Mount First-in, Last-Out Piping Arrangement. Brine T ank See NOTE Figure 7 Figure 6 Brine T ank(s) Figure 7 NOTE: System connections to the tank must accommodate longitudinal movement between side, top and bot- tom openings, exibility in piping or ex connec ...

  • Argosy Research H200 Series - page 11

    H200 HF Single T ank Installation H200 HF T win Alternating Installation H200 HF T riple x/Fourple x Installation Brine T ank See NOTE Figure 7 Figure 8 See NOTE Figure 7 Figure 9 See NOTE Figure 7 Figure 10 Outlet Meter High Flow Service V alve 1 Bypass V alve Inlet Outlet is Plugged High Flow Service V alve Pipe is on an angle Isolation V alve 1 ...

  • Argosy Research H200 Series - page 12

    RECOMMENDED BRINE T ANK APPROXIMA TE PIPE SIZE MINERAL T ANK SIZE SAL T STORAGE SHIPPING WEIGHT -TOP MOUNT MODEL (INCHES) (INCHES) (INCHES) ( LBS) SINGLE TWIN H200-240 2 24 X 72 24 X 50 715 674 1325 H200-300-24 2 24 X 72 24 X 50 715 776 1529 H200-300-30 2 30 X 72 30 X 50 1,1 10 1059 2064 H200-450-30 2 30 X 72 39 X 48 2,030 1333 2593 H200-450-36 2 3 ...

  • Argosy Research H200 Series - page 13

    RA TED CAP ACITY FLOW RA TES (gpm) RESIN LOW SAL T MEDIUM SAL T HIGH SAL T BKW MODEL CU.FT . GRAINS/LBS GRAINS/LBS GRAINS/LBS 15 PSI 25 PSI GPM H200HF-300-24-3 10 190,000/60 280,000/100 320,000/150 120 170 12 H200HF-300-30-3 10 190,000/60 280,000/100 320,000/150 175 225 20 H200HF-450-30-3 15 285,000/90 420,000/150 480,000/225 158 212 20 H200HF-450- ...

Производитель Argosy Research Категория Water System

Документы, которые мы получаем от производителя устройства Argosy Research H200 Series мы можем разделить на несколько групп. Это в частности:
- технические чертежи Argosy Research
- инструкции обслуживания H200 Series
- паспорта изделия Argosy Research
- информационные брошюры
- энергетические этикетки Argosy Research H200 Series
Все из них важны, однако самую важную информацию с точки зрения пользователя мы найдем в инструкции обслуживания Argosy Research H200 Series.

Группа документов, определяемая как инструкции обслуживания, делится также на более подробные типы, такие как: Инструкции монтажа Argosy Research H200 Series, инструкции обслуживания, короткие инструкции или инструкции пользователя Argosy Research H200 Series. В зависимости от потребностей, Вам необходимо поискать требуемый документ. На нашем сайте Вы можете просмотреть самую популярную инструкцию использования изделия Argosy Research H200 Series.

Похожие инструкции обслуживания

Полная инструкция обслуживания устройства Argosy Research H200 Series, как должна выглядеть?
Инструкция обслуживания, определяемая также как пособие пользователя, или просто "руководство" - это технический документ, цель которого заключается в использовании Argosy Research H200 Series пользователями. Инструкции пишет, как правило технический писатель, языком, доступным для всех пользователей Argosy Research H200 Series.

Полная инструкция обслуживания Argosy Research, должна заключать несколько основных элементов. Часть из них менее важная, как например: обложка / титульный лист или авторские страницы. Однако остальная часть, должна дать нам важную с точки зрения пользователя информацию.

1. Вступление и рекомендации, как пользоваться инструкцией Argosy Research H200 Series - В начале каждой инструкции, необходимо найти указания, как пользоваться данным пособием. Здесь должна находится информация, касающаяся местонахождения содержания Argosy Research H200 Series, FAQ и самых распространенных проблем - то есть мест, которые чаще всего ищут пользователи в каждой инструкции обслуживания
2. Содержание - индекс всех советов, касающихся Argosy Research H200 Series, которое найдем в данном документе
3. Советы по использованию основных функций устройства Argosy Research H200 Series - которые должны облегчить нам первые шаги во время использования Argosy Research H200 Series
4. Troubleshooting - систематизированный ряд действия, который поможет нам диагностировать а в дальнейшем очередность решения важнейших проблем Argosy Research H200 Series
5. FAQ - чаще всего задаваемые вопросы
6. Контактные данные Информация о том, где искать контактные данные производителя / сервисного центра Argosy Research H200 Series в данной стране, если самостоятельно не получится решить проблему.

У вас вопрос, касающийся Argosy Research H200 Series?

Воспользуйтесь формуляром, находящимся ниже

Если с помощью найденной инструкции Вы не решили свою проблему с Argosy Research H200 Series, задайте вопрос, заполнив следующий формуляр. Если у какого то из пользователей была похожая проблема с Argosy Research H200 Series со всей вероятностью он захочет поделиться методом ее решения.

Перепишите текст с картинки

Комментарии (0)