Инструкция обслуживания Dyna-Glo RMC-KFA120TDLX, RMC-KFA170TDLX

12 страниц 0.65 mb
Скачать

Перейти на страницу of 12

Summary
  • Dyna-Glo RMC-KFA120TDLX, RMC-KFA170TDLX - page 1

    4 2 2 1- 0 0 5 9 - 0 0 06/04 Rev. 00 EDITION 2004 PORTABLE FORCED AIR HEA TERS “USER’S MANUAL” Before the first use of this heater, please read this USER’S MANUAL very carefully. This USER’S MANUAL has been designed to instruct you as to the proper manner in which to assemble, maintain, store, and most importantly, how to operate the heat ...

  • Dyna-Glo RMC-KFA120TDLX, RMC-KFA170TDLX - page 2

    2 NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING! ITEM P AGE # PRECAUTIONS - SAFETY GUIDE 1 1. INTRODUCTION 2 2. FEATURES 2 3. UNPACKING AND ASSEMBLY 4 4. KEROSENE (1-K OR NO. 1 FUEL OIL) 6 5. OVERVIEW OF HEATER DESIGN 7 6. FUELING YOUR HEATER 7 7. OPERATION 8 8. LONG TERM STORAGE OF YOUR HEATER 9 9. MAINTENANCE 10 10. TROUBLE SHOOTING GUIDE 14 11 ...

  • Dyna-Glo RMC-KFA120TDLX, RMC-KFA170TDLX - page 3

    4 NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING! Figure 5. RMC-KFA120TDLX / RMC-KFA170TDLX MODELS Handle Wheels Wheels Caps Cord Wrap Cord Wrap Screws Hardware Kit Part No : HW-KFA1001 Hardware Kit Part No : HW-KFA1008 Screws(A) Screws(B) Bushing Washers Cotter Pins Front Handle 3. UNP ACKING AND ASSEMBL Y 1. REMOVE THE HEATER AND ALL PACKING MAT ...

  • Dyna-Glo RMC-KFA120TDLX, RMC-KFA170TDLX - page 4

    6 NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING! 4. KEROSENE (1-K) For optimal performance of this heater, it is strongly suggested that 1-K kerosene be used. 1-K kerosene has been refined to virtually eliminate contaminants, such as sulpher. Which can cause a rotten egg odor during the operation of the heater. However, #1 or #2 fuel oil (diesel ...

  • Dyna-Glo RMC-KFA120TDLX, RMC-KFA170TDLX - page 5

    7. OPERA TION A.) VENTILATION RISK OF INDOOR AIR POLLUTION/USE HEATER ONLY IN WELL VENTILATED AREAS. Provide a fresh air opening of at least three square feet (2,800 sq. cm) for each 100,000 BTU/Hr. rating. Provide extra fresh air if more heaters are being used. Example : A RMC-KFA170T-DLX heater requires one of the following: • a two-car garage ...

  • Dyna-Glo RMC-KFA120TDLX, RMC-KFA170TDLX - page 6

    A.) FUEL TANK FLUSH EVERY 200 HOURS OF OPERATION OR AS NEEDED (SEE STORAGE, PAGE 9) B.) UPPER SHELL REMOVAL -Remove Screw that secure Side Cover. -Push out for arrow direction and extract Side Cover's Bracket from Rectancle Hole and Separate Side Cover(R). -Side Cover(L) in opposite of Side Cover(R) Separates by same method. (RMC-KFA120T/170TD ...

  • Dyna-Glo RMC-KFA120TDLX, RMC-KFA170TDLX - page 7

    12 NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING! F.) SPARK PLUG CLEAN AND REGAP EVERY 600 HOURS OF OPERATION OR REPLACE AS NEEDED. -Remove upper shell(See 10 page). -Remove Fan Blade(See 11 Page). -Remove Ignitor Wire from Spark Plug. -Remove Spark Plug from Burner Head using medium phillips screwdriver. -Clean and regap Spark plug electrodes to ...

  • Dyna-Glo RMC-KFA120TDLX, RMC-KFA170TDLX - page 8

    14 NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING! 10. TROUBLE SHOOTING GUIDE 13 NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING! H.) FUEL FILTER CLEAN OR REPLACE TWICE A HEATING SEASON OR AS NEED. -Remove upper shell(See 10 page). -Remove Fan Blade(See 11 Page). -Pull Fuel Line off from Fuel Filter Neck. -Remove Fuel Filter. -Wash Fuel Filter wit ...

  • Dyna-Glo RMC-KFA120TDLX, RMC-KFA170TDLX - page 9

    16 NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING! RMC-KFA65TDLX RMC-KFA120TDLX / RMC-KFA170TDLX K FA 1 2 0 T- D L X K FA 1 7 0 T- D L X 25" 32.1" 18.5" 25" 36.9" 18.5" H D W M O D E L R M C - K FA 6 5 T D L X R M C - K FA 1 2 0 T D L X R M C - K FA 1 7 0 T D L X B T U / H r . 6 5 , 0 0 0 1 2 0 , 0 0 0 1 7 0 , 0 0 0 F ...

  • Dyna-Glo RMC-KFA120TDLX, RMC-KFA170TDLX - page 10

    ACCESSORIES Air Pressure Gauge SP-KFA1011 (all models) Thermostat SP-KFA1010 (all models) FOR TECHNICAL ASSISTANCE SEE YOUR LOCAL RETAILER OR CONTACT US AT: Phone : 1-800-668-5323 18 NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING! 14. P AR TS LIST(RMC-KF A65TDLX Model Only) KEY NO. D E S C R I P T I O N P A R TN O . KEY NO. D E S C R I P T I O N P ...

  • Dyna-Glo RMC-KFA120TDLX, RMC-KFA170TDLX - page 11

    20 NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING! 16. P AR TS LIST(RMC-KF A120T/170TDLX Models Only) Fuel Tank Assembly Fuel Gauge Fuel Gauge Cap Fuel Cap Filter Fuel Cap Fuel Filter Assembly Shell Lower Assembly Bushing Grommet(S) Bushing Grommet(L) Twist Lock Stand Off Nut Clip Cord Bushing Power Cord Air Line Temperature Limit Control Flange S ...

  • Dyna-Glo RMC-KFA120TDLX, RMC-KFA170TDLX - page 12

    22 NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING! 17. P AR TS LIST (WHEELS AND HANDLE) 1) RMC-KFA65TDLX MODEL 2) RMC-KFA120T/170TDLX MODELS 1 Handle 3231-0125-00 1 2 Cord Wrap 3231-0056-00 1 3 Hardware Kit HW-KFA1001 1 KEY NO. DESCRIPTION PART NO. RMC-KFA120TDLX RMC-KFA170TDLX QTY 1 Handle Front 3551-0039-00 3551-0040-00 1 2 Handle 3231-0126-00 3 ...

Производитель Dyna-Glo Категория Electric Heater

Документы, которые мы получаем от производителя устройства Dyna-Glo RMC-KFA120TDLX, RMC-KFA170TDLX мы можем разделить на несколько групп. Это в частности:
- технические чертежи Dyna-Glo
- инструкции обслуживания RMC-KFA120TDLX, RMC-KFA170TDLX
- паспорта изделия Dyna-Glo
- информационные брошюры
- энергетические этикетки Dyna-Glo RMC-KFA120TDLX, RMC-KFA170TDLX
Все из них важны, однако самую важную информацию с точки зрения пользователя мы найдем в инструкции обслуживания Dyna-Glo RMC-KFA120TDLX, RMC-KFA170TDLX.

Группа документов, определяемая как инструкции обслуживания, делится также на более подробные типы, такие как: Инструкции монтажа Dyna-Glo RMC-KFA120TDLX, RMC-KFA170TDLX, инструкции обслуживания, короткие инструкции или инструкции пользователя Dyna-Glo RMC-KFA120TDLX, RMC-KFA170TDLX. В зависимости от потребностей, Вам необходимо поискать требуемый документ. На нашем сайте Вы можете просмотреть самую популярную инструкцию использования изделия Dyna-Glo RMC-KFA120TDLX, RMC-KFA170TDLX.

Полная инструкция обслуживания устройства Dyna-Glo RMC-KFA120TDLX, RMC-KFA170TDLX, как должна выглядеть?
Инструкция обслуживания, определяемая также как пособие пользователя, или просто "руководство" - это технический документ, цель которого заключается в использовании Dyna-Glo RMC-KFA120TDLX, RMC-KFA170TDLX пользователями. Инструкции пишет, как правило технический писатель, языком, доступным для всех пользователей Dyna-Glo RMC-KFA120TDLX, RMC-KFA170TDLX.

Полная инструкция обслуживания Dyna-Glo, должна заключать несколько основных элементов. Часть из них менее важная, как например: обложка / титульный лист или авторские страницы. Однако остальная часть, должна дать нам важную с точки зрения пользователя информацию.

1. Вступление и рекомендации, как пользоваться инструкцией Dyna-Glo RMC-KFA120TDLX, RMC-KFA170TDLX - В начале каждой инструкции, необходимо найти указания, как пользоваться данным пособием. Здесь должна находится информация, касающаяся местонахождения содержания Dyna-Glo RMC-KFA120TDLX, RMC-KFA170TDLX, FAQ и самых распространенных проблем - то есть мест, которые чаще всего ищут пользователи в каждой инструкции обслуживания
2. Содержание - индекс всех советов, касающихся Dyna-Glo RMC-KFA120TDLX, RMC-KFA170TDLX, которое найдем в данном документе
3. Советы по использованию основных функций устройства Dyna-Glo RMC-KFA120TDLX, RMC-KFA170TDLX - которые должны облегчить нам первые шаги во время использования Dyna-Glo RMC-KFA120TDLX, RMC-KFA170TDLX
4. Troubleshooting - систематизированный ряд действия, который поможет нам диагностировать а в дальнейшем очередность решения важнейших проблем Dyna-Glo RMC-KFA120TDLX, RMC-KFA170TDLX
5. FAQ - чаще всего задаваемые вопросы
6. Контактные данные Информация о том, где искать контактные данные производителя / сервисного центра Dyna-Glo RMC-KFA120TDLX, RMC-KFA170TDLX в данной стране, если самостоятельно не получится решить проблему.

У вас вопрос, касающийся Dyna-Glo RMC-KFA120TDLX, RMC-KFA170TDLX?

Воспользуйтесь формуляром, находящимся ниже

Если с помощью найденной инструкции Вы не решили свою проблему с Dyna-Glo RMC-KFA120TDLX, RMC-KFA170TDLX, задайте вопрос, заполнив следующий формуляр. Если у какого то из пользователей была похожая проблема с Dyna-Glo RMC-KFA120TDLX, RMC-KFA170TDLX со всей вероятностью он захочет поделиться методом ее решения.

Перепишите текст с картинки

Комментарии (0)