Инструкция обслуживания Soleus Air GM-PAC-08E3

16 страниц 6.32 mb
Скачать

Перейти на страницу of 16

Summary
  • Soleus Air GM-PAC-08E3 - page 1

    8,000 BTU Portable Air Conditioner Operating Instructions Model GM-P AC-08E3 ...

  • Soleus Air GM-PAC-08E3 - page 2

    Thank you for choosing a Soleus Air Powered by Gree Portable Air Conditioner. This owner’s man- ual will provide you with valuable information necessary for the proper care and maintenance of your new product. Please take a few mome nts to thoroughly read the instructions and familiarize yourself with all the operational aspects of your new Porta ...

  • Soleus Air GM-PAC-08E3 - page 3

    3 SPEC IFICA TIONS • The cooling capacity is measured at an ambient tem perature of DB 95 °F, WB 83 °F. • Noise level is measured at a distance of 3.28 ft away from the front of the unit, when the unit is in coolin g mode. • Power consumption is measured when the fan runs at the highest speed setting. • These specifications are for refere ...

  • Soleus Air GM-PAC-08E3 - page 4

    LCDI POWER CORD AND PLUG This air conditioner is equipped with an LCDI (Leakage Current Detection and Interruption) power cord and plug as required by US National Electric Code 440.65. This cord consists of a length of shielded flexible cord with no termination on the load side and a LCDI attachment plug on the line side. The LCDI power cord and pl ...

  • Soleus Air GM-PAC-08E3 - page 5

    PRODUCT DIAGRAM Control Panel 5 Louvers Louver Guides Casters Power Cord Filters Upper Air Intake Lower Air Intake Remote Control Holder Air Exhaust V ent ...

  • Soleus Air GM-PAC-08E3 - page 6

    P ARTS & WINDOW KIT ASSEMBL Y PARTS EXHAUST HOSE & ADAPTERS ASSEMBLY & INSTALLATION INSTALLATION When the unit is operating as an air conditioner or dehumidifier, the window kit and exhaust hose must be install ed. When the unit is operating in fan mode, the win dow kit and exhaust hose do not need to be installed . MOUNTING THE EXHAUST ...

  • Soleus Air GM-PAC-08E3 - page 7

    7 SINGLE HOSE WINDOW KIT INSTALLATION When installing the exhaust hose, try and keep it as flat as possible. The less angles and bends in the hose, the better the unit will perform. If be nding or an angle is necessary , use single 90 ° angles like the pictures above and below . Multip le bends will decrease performance and effi- ciency This insta ...

  • Soleus Air GM-PAC-08E3 - page 8

    CONTROL P ANEL, DISPLA Y , & OPERA TING INSTRUCTIONS CONTROL PANEL & LED DISPLAY CONTROL PANEL OPERATING INSTRUCTIONS 1) Power On and Off - Press the POWER button once to manually turn the unit on. Press the POWER button once more to turn the unit off. 2) Mode Selection - Press the MODE Button repeatedly to cycle betwee n the different m od ...

  • Soleus Air GM-PAC-08E3 - page 9

    Cool, Dry, Cool, Dry, ...

  • Soleus Air GM-PAC-08E3 - page 10

    Sleep Mode - Press the SLEEP mode button to engage S LEEP mode. Sleep m ode automatically rises the set temperature by 2 ° F after one hour and 4 ° F after two hours. This feat ure limits compressor usage and enhances energy savings while you are sleeping. Auto Mode - When AUTO mode is selected th e air cond ition er will automatically ch oose th ...

  • Soleus Air GM-PAC-08E3 - page 11

    11 When the temperature or humidity is too high, the air conditioner may not be able to evaporate all of the water as quickly as needed. All moisture th at is unable to be evaporated is placed in a sm all bank up water tank in- side the unit. When this tank is com pletely full, an alarm will s ound, the compressor will shut off, and the bucket full ...

  • Soleus Air GM-PAC-08E3 - page 12

    MAINTENANCE Note: Make sure power is off and the power cord is not plugged into an el ectrical outlet prior to performing any maintenance on the unit. Clean or replace filter - If the air filter is blocked with a dust, the airflow volum e may reduce. It is recommended to clean the filter onc e every two weeks or as needed. 1) Remove the filter from ...

  • Soleus Air GM-PAC-08E3 - page 13

    PROBLEM The Air Conditioner will not start POSSIBLE CAUSES The air conditioner is unplu gged or not connected well. The fuse is blown/circuit breaker is tripped. Power Failure The current interrupter device is tripped. SOLUTIONS • Make sure the air conditio ner plug is pushed completely into the out- let • Check the house fuse/ci rcuit breaker ...

  • Soleus Air GM-PAC-08E3 - page 14

    PROBLEM The LED Display is showing “E5” POSSIBLE CAUSES Over Current Protection SOLUTIONS • Unplug for 10 minutes and then turn on the unit. If “E5” is still dis- played, contact customer service. TROUBLESHOOTING (CONT .) The LED Display is showing “H8” The backup water tank is full • Drain the water tank • If the “H8” I still ...

  • Soleus Air GM-PAC-08E3 - page 15

    W ARRANTY One Year Limited Warranty Soleus International Inc. warrants the ac companying Soleus Air Powered by Gree Portable Air Conditioner to be free of defects in material and workmanship for the applications sp ecified in its operation instruction for a period of ONE (1) year from the date of original retail purchase in the United States. If th ...

  • Soleus Air GM-PAC-08E3 - page 16

    66129906894 ...

Производитель Soleus Air Категория Air Conditioner

Документы, которые мы получаем от производителя устройства Soleus Air GM-PAC-08E3 мы можем разделить на несколько групп. Это в частности:
- технические чертежи Soleus Air
- инструкции обслуживания GM-PAC-08E3
- паспорта изделия Soleus Air
- информационные брошюры
- энергетические этикетки Soleus Air GM-PAC-08E3
Все из них важны, однако самую важную информацию с точки зрения пользователя мы найдем в инструкции обслуживания Soleus Air GM-PAC-08E3.

Группа документов, определяемая как инструкции обслуживания, делится также на более подробные типы, такие как: Инструкции монтажа Soleus Air GM-PAC-08E3, инструкции обслуживания, короткие инструкции или инструкции пользователя Soleus Air GM-PAC-08E3. В зависимости от потребностей, Вам необходимо поискать требуемый документ. На нашем сайте Вы можете просмотреть самую популярную инструкцию использования изделия Soleus Air GM-PAC-08E3.

Похожие инструкции обслуживания

Полная инструкция обслуживания устройства Soleus Air GM-PAC-08E3, как должна выглядеть?
Инструкция обслуживания, определяемая также как пособие пользователя, или просто "руководство" - это технический документ, цель которого заключается в использовании Soleus Air GM-PAC-08E3 пользователями. Инструкции пишет, как правило технический писатель, языком, доступным для всех пользователей Soleus Air GM-PAC-08E3.

Полная инструкция обслуживания Soleus Air, должна заключать несколько основных элементов. Часть из них менее важная, как например: обложка / титульный лист или авторские страницы. Однако остальная часть, должна дать нам важную с точки зрения пользователя информацию.

1. Вступление и рекомендации, как пользоваться инструкцией Soleus Air GM-PAC-08E3 - В начале каждой инструкции, необходимо найти указания, как пользоваться данным пособием. Здесь должна находится информация, касающаяся местонахождения содержания Soleus Air GM-PAC-08E3, FAQ и самых распространенных проблем - то есть мест, которые чаще всего ищут пользователи в каждой инструкции обслуживания
2. Содержание - индекс всех советов, касающихся Soleus Air GM-PAC-08E3, которое найдем в данном документе
3. Советы по использованию основных функций устройства Soleus Air GM-PAC-08E3 - которые должны облегчить нам первые шаги во время использования Soleus Air GM-PAC-08E3
4. Troubleshooting - систематизированный ряд действия, который поможет нам диагностировать а в дальнейшем очередность решения важнейших проблем Soleus Air GM-PAC-08E3
5. FAQ - чаще всего задаваемые вопросы
6. Контактные данные Информация о том, где искать контактные данные производителя / сервисного центра Soleus Air GM-PAC-08E3 в данной стране, если самостоятельно не получится решить проблему.

У вас вопрос, касающийся Soleus Air GM-PAC-08E3?

Воспользуйтесь формуляром, находящимся ниже

Если с помощью найденной инструкции Вы не решили свою проблему с Soleus Air GM-PAC-08E3, задайте вопрос, заполнив следующий формуляр. Если у какого то из пользователей была похожая проблема с Soleus Air GM-PAC-08E3 со всей вероятностью он захочет поделиться методом ее решения.

Перепишите текст с картинки

Комментарии (0)