  • Westinghouse UL-ES-Xavier-WH05 - page 1

    UL-ES-Xavier-WH05 MR OWNER'S MANUAL MANUAL DEL USUARIO Xavier TM Please write model number here for future reference: / Por favor , incluya el número del modelo aquí para futura referencia: Net W eight: 17.18 LBS Peso Neto: 7.81 KGS UL_Xavier_72265 12/13/05 9:18 AM Page 1 ...

  • Westinghouse UL-ES-Xavier-WH05 - page 2

    2 UL-ES-Xavier-WH05 1. Installation work and electrical wiring must be done by qualified person(s) in accordance with all applicable codes and standards (ANSI/NFPA 70-1996), including fire-rated construction. 2. Use this unit only in the manner intended by the manufacturer . If you have any questions contact the manufacturer . 3. After making the w ...

  • Westinghouse UL-ES-Xavier-WH05 - page 3

    3 UL-ES-Xavier-WH05 1. El trabajo de instalación y el cableado eléctrico los deben efectuar personas calificadas cumpliendo con todos los códigos y las normas aplicables (ANSI/NFPA 70-1996), incluyendo las de incendio. 2. Use esta unidad sólo de la manera en que el fabricante quiere que se haga. Si tiene dudas, llame al fabricante. 3. Después ...

  • Westinghouse UL-ES-Xavier-WH05 - page 4

    4 UL-ES-Xavier-WH05 FEA TURES CARACTERÍSTICAS DOWNROD INST ALLATION INST ALACIÓN CON V ARILLA VERTICAL For normal ceilings Para cielorrasos normales V AUL TED CEILING INST ALLATION INST ALACIÓN PARA CIELORRASOS ABOVEDADOS May require a longer downrod (sold separately) Podría requerir una varilla vertical más larga (se vende por separado) FLUSH ...

  • Westinghouse UL-ES-Xavier-WH05 - page 5

    5 UL-ES-Xavier-WH05 Unpack and inspect fan carefully to be certain all contents are included. T urn off power at fuse box to avoid possible electrical shock. 1 Use metal outlet box suitable for fan support (must support 35 lbs). Before attaching fan to outlet box, ensure the outlet box is securely fastened by at least two points to a structural cei ...

  • Westinghouse UL-ES-Xavier-WH05 - page 6

    6 UL-ES-Xavier-WH05 MOUNTING BRACKET INST ALLA TION INST ALACIÓN CON SOPOR TE DE MONT AJE 3 Remove the screws and star washers from the two mating holes (1) on the canopy . Loosen (do not remove) the screws in the mating slots (2) on the canopy . Rotate the mounting bracket and remove from the canopy . Quite los tornillos y las dos arandelas en es ...

  • Westinghouse UL-ES-Xavier-WH05 - page 7

    7 UL-ES-Xavier-WH05 MOUNTING BRACKET INST ALLA TION INST ALACIÓN CON SOPOR TE DE MONT AJE 5 MOUNTING OPTIONS OPCIONES DE MONT AJE Choose a MOUNTING OPTION Elija una OPCIÓN DE MONT AJE FLUSH MOUNT OPTION If flush mount option is selected, proceed to page 8, step 6. OPCIÓN DE INST ALACIÓN AL RAS Si elige la opción de montaje al ras, proceda a la ...

  • Westinghouse UL-ES-Xavier-WH05 - page 8

    8 8 UL-ES-Xavier-WH05 FLUSH MOUNT OPTION OPCIÓN DE INST ALACIÓN AL RAS Remove three flush mount screws and lock washers from the top of the motor housing (1) and save for later use. Quite tres tornillos de montaje al ras y arandelas de presión de la parte superior del acoplamiento del motor (1) y guárdelos para usarlos más tarde. 7 Guide motor ...

  • Westinghouse UL-ES-Xavier-WH05 - page 9

    9 UL-ES-Xavier-WH05 NORMAL DOWNROD OPTION OPCIÓN CON V ARILLA VER TICAL P ARA CIELORRASO NORMAL Place downrod assembly (1) into canopy (2), canopy cover ring (3) and coupling cover (4).Feed motor wires though the downrod assembly (1). Coloque el conjunto de la varilla vertical (1) dentro del dosel (2), el anillo de la cubierta del dosel (3) y la c ...

  • Westinghouse UL-ES-Xavier-WH05 - page 10

    10 UL-ES-Xavier-WH05 EXTENDED DOWNROD OPTION OPCIÓN CON V ARILLA VER TICAL MÁS LARGA 11 12 Loosen downrod ball (1) from downrod (2) by removing set screw (3). Afloje la esfera de la varilla vertical (1) de la varilla vertical (2) quitando el tornillo (3). 2 1 2 1 Slide downrod ball (1) off of downrod and remove pin (2). Deslice la esfera de la va ...

  • Westinghouse UL-ES-Xavier-WH05 - page 11

    11 UL-ES-Xavier-WH05 MOUNTING MONT AJE Carefully lift fan assembly onto mounting bracket. Rotate fan until notch on downrod ball (1) engages the ridge on the mounting bracket (2). This will allow for hands free wiring. With bracket holding fan assembly , make electrical connections using the following step for wiring instructions. Levante con cuida ...

  • Westinghouse UL-ES-Xavier-WH05 - page 12

    12 UL-ES-Xavier-WH05 WIRING OPTIONS OPCIÓN DE CABLEADO 16 White (common) Black (hot) Blue* (hot) Main (ground) White (common) Fan Switch (hot) Light Switch (hot) Green (ground) From Fan: From House: (connect) (connect) (connect) (connect) *Attach blue wire only if attaching light kit with fan. Wall Control Follow diagram above to make wiring conne ...

  • Westinghouse UL-ES-Xavier-WH05 - page 13

    2 3 1 13 UL-ES-Xavier-WH05 17 The canopy has two mating slots (1) and two mating holes (2). Position both slots on canopy directly under and in line with two screws in the mounting bracket (3). Lift the canopy , allowing the two screws to slide into the mating slots. Rotate the canopy until both screws from the mounting bracket drop into the slot r ...

  • Westinghouse UL-ES-Xavier-WH05 - page 14

    14 UL-ES-Xavier-WH05 18 T o install the canopy cover ring, peel the backing off the adhesive tape strips on the inside of the cover ring. Slide the cover ring up the downrod and secure to the canopy by gently pressing the adhesive tape to the bottom of the canopy . CAUTION! : Be careful and precise when attaching the canopy cover ring to the canopy ...

  • Westinghouse UL-ES-Xavier-WH05 - page 15

    15 UL-ES-Xavier-WH05 BLADE INST ALLA TION INST ALACIÓN DE LAS P ALET AS 19 Attach blade brackets to blades using the blade bracket screws (1) and fabric washers (2). Fije los soportes para paletas a las paletas con los tornillos (1) y las arandelas de tela (2). 2 1 21 Attach blade assembly to motor using motor screws provided. Tighten screws secur ...

  • Westinghouse UL-ES-Xavier-WH05 - page 16

    16 UL-ES-Xavier-WH05 LIGHT FIXTURE INST ALLA TION INST ALACIÓN DEL AR TEF ACTO LUMINOSO Insert the wires from the motor through the hole in the switch housing, and connect the wires in switching housing to the wires from motor , using the 9 pin molex plug. Pase los cables del motor a través del orificio del alojamiento del interruptor y use el co ...

  • Westinghouse UL-ES-Xavier-WH05 - page 17

    17 UL-ES-Xavier-WH05 Attach the switch housing (1) to the switch housing plate (2) by placing the keyslot holes from the switch housing (3) onto the two protruding screw heads on the switch housing plate (4). T wist the switch housing until the screwheads engage the keyslots. Install screw removed from switch housing plate (step 22) into the closed ...

  • Westinghouse UL-ES-Xavier-WH05 - page 18

    18 UL-ES-Xavier-WH05 26 25 Find the wire plugs from the light kit and from the motor and slide together . Connect the blue wire from the switch housing, to the black wire from the light kit, and the white wire from the switch housing to the white wire from the light kit. Identifique los conectores para cables de salida del artefacto luminoso y del ...

  • Westinghouse UL-ES-Xavier-WH05 - page 19

    28 Assemble decorative fob and extension chains from hardware bag to fan pull chains by inserting end of chain into chain coupling. Confirm chains are held by lightly pulling both chains in coupling. Sujetar las cadenas largas de tiro con las piezas finales correspondientes, a las cadenas del ventilador , introduciendo el extremo de la cadena larga ...

  • Westinghouse UL-ES-Xavier-WH05 - page 20

    20 UL-ES-Xavier-WH05 Operation T urn on the power and check operation of fan. The pull chain controls the fan speeds as follows: 1 pull - high; 2 pulls - medium; 3 pulls - low; 4 pulls - off. Speed settings for warm or cool weather depend on factors such as room size, ceiling height, number of fans and so on. The slide switch controls direction, fo ...

  • Westinghouse UL-ES-Xavier-WH05 - page 21

    21 UL-ES-Xavier-WH05 Operación Encienda el ventilador y verifique su funcionamiento. La cadenilla de tiro controla las velocidades del ventilador de la siguiente manera: 1 jalón – rápida; 2 jalones - mediana; 3 jalones - lenta; 4 jalones - apagado. Las velocidades para clima cálido o frío dependen de factores como el tamaño de la habitació ...

  • Westinghouse UL-ES-Xavier-WH05 - page 22

    22 UL-ES-Xavier-WH05 TROUBLESHOOTING GUIDE If you have difficulty operating your new ceiling fan, it may be the result of incorrect assembly , installation, or wiring. In some cases, these installation errors may be mistaken for defects. If you experience any faults, please check this T rouble Shooting Chart. If a problem cannot be remedied, please ...

  • Westinghouse UL-ES-Xavier-WH05 - page 23

    23 UL-ES-Xavier-WH05 GUÍA P ARA SOLUCIONAR PROBLEMAS Si tiene dificultades para hacer funcionar su nuevo ventilador , podría ser a causa del armado, instalación o cableado incorrectos. En algunos casos, estos errores de instalación podrían ser confundidos con defectos. Si experimenta alguna falla, consulte esta guía para solucionar problemas. ...

  • Westinghouse UL-ES-Xavier-WH05 - page 24

    24 UL-ES-Xavier-WH05 UL_Xavier_72265 12/13/05 9:18 AM Page 24 ...

  • Westinghouse UL-ES-Xavier-WH05 - page 25

    25 UL-ES-Xavier-WH05 UL_Xavier_72265 12/13/05 9:18 AM Page 25 ...

  • Westinghouse UL-ES-Xavier-WH05 - page 26

    26 UL-ES-Xavier-WH05 UL_Xavier_72265 12/13/05 9:18 AM Page 26 ...

  • Westinghouse UL-ES-Xavier-WH05 - page 27

    27 UL-ES-Xavier-WH05 P AR TS LIST LIST A DE REPUESTOS 1 2 3 # Description 1 . . . . . . . . . . . . . . . . . Mounting Bracket 2 . . . . . . . . . . . . . . . . . Blade Bracket 3 . . . . . . . . . . . . . . . . . Blade 4 . . . . . . . . . . . . . . . . . Fan Speed Switch 5 . . . . . . . . . . . . . . . . . Light Control Switch 6 . . . . . . . . . . ...

  • Westinghouse UL-ES-Xavier-WH05 - page 28

    UL-ES-Xavier-WH05 Westinghouse Lighting Corporation 12401 McNulty Road Philadelphia, P A 19154 U.S.A. Westinghouse Lighting Corporation, a Westinghouse Electric Corporation licensee is a registered trademark of Westinghouse Electric Corporation Made in China © 2005 Westinghouse Lighting Corporation Westinghouse Lighting Corporation 12401 McNulty R ...

Производитель Westinghouse Категория Fan

Документы, которые мы получаем от производителя устройства Westinghouse UL-ES-Xavier-WH05 мы можем разделить на несколько групп. Это в частности:
- технические чертежи Westinghouse
- инструкции обслуживания UL-ES-Xavier-WH05
- паспорта изделия Westinghouse
- информационные брошюры
- энергетические этикетки Westinghouse UL-ES-Xavier-WH05
Все из них важны, однако самую важную информацию с точки зрения пользователя мы найдем в инструкции обслуживания Westinghouse UL-ES-Xavier-WH05.

Группа документов, определяемая как инструкции обслуживания, делится также на более подробные типы, такие как: Инструкции монтажа Westinghouse UL-ES-Xavier-WH05, инструкции обслуживания, короткие инструкции или инструкции пользователя Westinghouse UL-ES-Xavier-WH05. В зависимости от потребностей, Вам необходимо поискать требуемый документ. На нашем сайте Вы можете просмотреть самую популярную инструкцию использования изделия Westinghouse UL-ES-Xavier-WH05.

Похожие инструкции обслуживания

Полная инструкция обслуживания устройства Westinghouse UL-ES-Xavier-WH05, как должна выглядеть?
Инструкция обслуживания, определяемая также как пособие пользователя, или просто "руководство" - это технический документ, цель которого заключается в использовании Westinghouse UL-ES-Xavier-WH05 пользователями. Инструкции пишет, как правило технический писатель, языком, доступным для всех пользователей Westinghouse UL-ES-Xavier-WH05.

Полная инструкция обслуживания Westinghouse, должна заключать несколько основных элементов. Часть из них менее важная, как например: обложка / титульный лист или авторские страницы. Однако остальная часть, должна дать нам важную с точки зрения пользователя информацию.

1. Вступление и рекомендации, как пользоваться инструкцией Westinghouse UL-ES-Xavier-WH05 - В начале каждой инструкции, необходимо найти указания, как пользоваться данным пособием. Здесь должна находится информация, касающаяся местонахождения содержания Westinghouse UL-ES-Xavier-WH05, FAQ и самых распространенных проблем - то есть мест, которые чаще всего ищут пользователи в каждой инструкции обслуживания
2. Содержание - индекс всех советов, касающихся Westinghouse UL-ES-Xavier-WH05, которое найдем в данном документе
3. Советы по использованию основных функций устройства Westinghouse UL-ES-Xavier-WH05 - которые должны облегчить нам первые шаги во время использования Westinghouse UL-ES-Xavier-WH05
4. Troubleshooting - систематизированный ряд действия, который поможет нам диагностировать а в дальнейшем очередность решения важнейших проблем Westinghouse UL-ES-Xavier-WH05
5. FAQ - чаще всего задаваемые вопросы
6. Контактные данные Информация о том, где искать контактные данные производителя / сервисного центра Westinghouse UL-ES-Xavier-WH05 в данной стране, если самостоятельно не получится решить проблему.

У вас вопрос, касающийся Westinghouse UL-ES-Xavier-WH05?

Воспользуйтесь формуляром, находящимся ниже

Если с помощью найденной инструкции Вы не решили свою проблему с Westinghouse UL-ES-Xavier-WH05, задайте вопрос, заполнив следующий формуляр. Если у какого то из пользователей была похожая проблема с Westinghouse UL-ES-Xavier-WH05 со всей вероятностью он захочет поделиться методом ее решения.

Перепишите текст с картинки

Комментарии (0)