    026-1307 Rev 1 11-30-07 Modular Refrigerant Leak Detection Sensor (MRLDS) Inst allation and Operation Manual ...

  • Emerson MRLDS - page 2

    ...

  • Emerson MRLDS - page 3

    Computer Process Controls, Inc. 1640 Airport Road Suite #104 Kennesaw, GA 31044 Phone 770-425-2724 Fax 770-425-9319 ALL RIGHTS RESERVED The information contained in this manual ha s been carefully chec ked and is believed to be accurate. However, Com puter Process Controls, Inc. assumes no resp onsibility for any inaccuracies t hat may be contained ...

  • Emerson MRLDS - page 4

    ...

  • Emerson MRLDS - page 5

    MRLDS I&O Manual Table of Contents • v Table Of Contents 1 OVERVIEW ............ .............. .............. .............. .............. .............. ............... .............. ........... .............. .............. ............. 1 1.1 S PECIFICATIONS .............. .............. ............... .............. .............. ... ...

  • Emerson MRLDS - page 6

    ...

  • Emerson MRLDS - page 7

    Specifications Overvi ew • 1 1 Overview CPC specs a modular refrigerant leak detection sensor (MRLDS) that continuously monitors for low levels of refrigerants most commonl y us ed in commercial refrigera- tion systems. The MRLDS communicates with the E2 controller via a Gateway board connected to the RS485 I/O Network, or via the analog input on ...

  • Emerson MRLDS - page 8

    2 • MRLDS I&O Manual 026-1307 Rev 1 11-30-07 2 Choosing a Mounting Location Proper location of the refriger ant sensor is necessary to ensure accurate measurement of representative air sam- ples. Mount the sensor: • Indoors, inside a room area where air circulates freely . • On a flat, interior surface. • Approximately 12-18 inches (30- ...

  • Emerson MRLDS - page 9

    MRLDS Dimensions MRLDS Analog Version (809-100x) • 3 2.2 MRLDS Dimensions 3 MRLDS Analog V ersion (809-100x) 3.1 Network Layout 3.2 MRLDS W iring For analog MRLDS units, connect to a MultiFlex board via the analog input (use Belden 87 61 cable). Figure 2-2 - Attaching and Removing Cover Figure 2-3 - MRLDS Mounting Dimensions Figure 3-1 - Analog M ...

  • Emerson MRLDS - page 10

    4 • MRLDS I&O Manual 026-1307 Rev 1 11-30-07 3.3 R efrigerant Jumper Settings The jumper set tings for refr igerant types are located on the label inside the MRLDS sensor cover (shown in Fig- ure 1-1 ). Set the jumpers according to how they are indi- cated on the label. The MRLDS supports th ree different refrigerant types. Select the desired ...

  • Emerson MRLDS - page 11

    Network Layout MRLDS Mo dbus Version (809-101x) • 5 3.4.3 RMCC Controllers For RMCC-type controllers, set the Gain parame ter to 250 and Offset to -10 00 . 4M R L D S M o d b u s V ersion (809-101x) 4.1 Network Layout 4.2 MRLDS Setup 4.2.1 MRLDS W iring 4.2.2 MRLDS Network A ddressing Modbus network settings are set on jumpers J5 , J4 , and J3 . ...

  • Emerson MRLDS - page 12

    6 • MRLDS I&O Manual 026-1307 Rev 1 11-30-07 4.2.3 Address Settings 4.2.4 Refrigerant Jumper Settings The jumper set tings for refr igerant types are located on the label inside the MRLDS sensor cover (shown in Fig- ure 1-1 ). Set the jumpers according to how they are indi- cated on the label. The MRLDS supports th ree different refrigerant t ...

  • Emerson MRLDS - page 13

    MRLDS Gateway MRLDS Modbus Version (809-101x) • 7 bits with no parity and 2 (two) stop b its. 4.3 MRLDS Gateway 4.3.1 MRLDS Gateway Setup on I/O Network Modbus versions of the MRLDS must be connected to the 810-3040 MRLDS Gateway . The MRLDS Gateway can be mapped in either of two ways: it can be set up on I/O Net as an IRLDS applicat ion or as a ...

  • Emerson MRLDS - page 14

    8 • MRLDS I&O Manual 026-1307 Rev 1 11-30-07 The Gateway Board commun icates with the MRLDS via the Modbus network, which is connected to the Gate- way’ s “Receiver Bus” network terminal. The Gateway communicates with the E2 via the RS485 I/O Network. 4.3.4 P owering the Gateway Board The Gateway board requires 24V AC power from a Class ...

  • Emerson MRLDS - page 15

    MRLDS Gateway MRLDS Modbus Version (809-101x) • 9 controller ’ s user manual. T o connect the Gateway to an MRLDS, feed the wires through the rectangular opening in the sen s or base as in di- cated in Figure 1-1 . Locate the RS485 connector and secure the wire leads to the connector orienting them as shown in Figure 4-10 . Connect multiple MRL ...

  • Emerson MRLDS - page 16

    10 • MRLDS I&O Manual 026-1307 Rev 1 11-30-07 4.3.9 Setting the Baud Rate Dip Switches Dip switches 6 and 7 control the baud rate at which th e Gateway communicates w ith the site co ntroller on the RS485 Network. These switches must be set to the same baud rate setting as the controller you are usin g (Ein stein, RMCC, or E2), and defaults t ...

  • Emerson MRLDS - page 17

    Controller Setup for Modbus MRLDS MRLDS Modbus Version (809-101x) • 11 4.3.10.4 Setup/Online Screen 2 - The Setup/Online screen displays the addressing of the devices and whether they are enabled. Press the right/ left arrows to select the first address in the list. T ogg le the minus button to enable the first address in the list ( Figure 4-18 ) ...

  • Emerson MRLDS - page 18

    12 • MRLDS I&O Manual 026-1307 Rev 1 11-30-07 ways. Navigate to the controller ’ s Input Status screen and highlight the board and point that yo u wish to map. Press F1 to go to the Input Setup screen for that board/ point. Each point will increase incr ementally to co rrespond with each board. ( For example, wher e the MRLDS is addr ess 1 ...

  • Emerson MRLDS - page 19

    Controller Setup for Modbus MRLDS MRLDS Modbus Version (809-101x) • 13 field to change the name, and press the down or right arrow to move to the (sensor) Type field. Use the “.” and “ — ” keys to scroll through the options and select IRLDS . (The Gain and Offset parameters are automatically configured for you.) 13. Use the arrow keys t ...

  • Emerson MRLDS - page 20

    14 • MRLDS I&O Manual 026-1307 Rev 1 11-30-07 “MV” should be entered for sensor inputs that read fault status. Gain and Offset Since the output terminals emit one volt fo r every 250 ppm of refrigerant detect ed, the gain for the refrigeran t leak sensors must be set to 250 and the O ffset to 0. The sensors configured to det ect faults mu ...

Производитель Emerson Категория Stud Sensor

Документы, которые мы получаем от производителя устройства Emerson MRLDS мы можем разделить на несколько групп. Это в частности:
- технические чертежи Emerson
- инструкции обслуживания MRLDS
- паспорта изделия Emerson
- информационные брошюры
- энергетические этикетки Emerson MRLDS
Все из них важны, однако самую важную информацию с точки зрения пользователя мы найдем в инструкции обслуживания Emerson MRLDS.

Группа документов, определяемая как инструкции обслуживания, делится также на более подробные типы, такие как: Инструкции монтажа Emerson MRLDS, инструкции обслуживания, короткие инструкции или инструкции пользователя Emerson MRLDS. В зависимости от потребностей, Вам необходимо поискать требуемый документ. На нашем сайте Вы можете просмотреть самую популярную инструкцию использования изделия Emerson MRLDS.

Похожие инструкции обслуживания

Полная инструкция обслуживания устройства Emerson MRLDS, как должна выглядеть?
Инструкция обслуживания, определяемая также как пособие пользователя, или просто "руководство" - это технический документ, цель которого заключается в использовании Emerson MRLDS пользователями. Инструкции пишет, как правило технический писатель, языком, доступным для всех пользователей Emerson MRLDS.

Полная инструкция обслуживания Emerson, должна заключать несколько основных элементов. Часть из них менее важная, как например: обложка / титульный лист или авторские страницы. Однако остальная часть, должна дать нам важную с точки зрения пользователя информацию.

1. Вступление и рекомендации, как пользоваться инструкцией Emerson MRLDS - В начале каждой инструкции, необходимо найти указания, как пользоваться данным пособием. Здесь должна находится информация, касающаяся местонахождения содержания Emerson MRLDS, FAQ и самых распространенных проблем - то есть мест, которые чаще всего ищут пользователи в каждой инструкции обслуживания
2. Содержание - индекс всех советов, касающихся Emerson MRLDS, которое найдем в данном документе
3. Советы по использованию основных функций устройства Emerson MRLDS - которые должны облегчить нам первые шаги во время использования Emerson MRLDS
4. Troubleshooting - систематизированный ряд действия, который поможет нам диагностировать а в дальнейшем очередность решения важнейших проблем Emerson MRLDS
5. FAQ - чаще всего задаваемые вопросы
6. Контактные данные Информация о том, где искать контактные данные производителя / сервисного центра Emerson MRLDS в данной стране, если самостоятельно не получится решить проблему.

У вас вопрос, касающийся Emerson MRLDS?

Воспользуйтесь формуляром, находящимся ниже

Если с помощью найденной инструкции Вы не решили свою проблему с Emerson MRLDS, задайте вопрос, заполнив следующий формуляр. Если у какого то из пользователей была похожая проблема с Emerson MRLDS со всей вероятностью он захочет поделиться методом ее решения.

Перепишите текст с картинки

Комментарии (0)