Инструкция обслуживания Zephyr COK-E48SX

23 страниц 0.87 mb
Скачать

Перейти на страницу of 23

Summary
  • Zephyr COK-E48SX - page 1

    Okeanito C O K -E36SX C O K-E42SX C O K -E48SX U s e , C a r e , a n d I n s t a lla t ion G u id e MAY07.0101 ww w .zephyronline.com Model number: Serial number: Date of Purchase: Sales Dealer: © Zep hyr Corpo ration. ...

  • Zephyr COK-E48SX - page 2

    www .zephyronline.com ...

  • Zephyr COK-E48SX - page 3

    Ta b l e o f C o n t e n t s 1 SAFET Y NOTICE .............................................. LIST OF MA TERIALS ....................................... INST ALLA TION Ducting Calculation Sheet ............................... Mounting Height and Clearance ..................... Ducting ................................................................. ...

  • Zephyr COK-E48SX - page 4

    www .zephyronline.com Im p or tan t s afety N o t i c e 2 TO R E D U C E T H E R I S K O F F I R E O R E L E C T R IC SH OC K, D O N O T USE T H IS FAN W ITH ANY S O L ID- S T A TE SP E E D CONTRO L DE V I C E . TO R E DU C E T H E R IS K O F F I R E, E L E C T R I C SH O C K, O R INJ U R Y T O P E R S ON S, O B S E RVE T H E FO L LO W I N G: a. Us ...

  • Zephyr COK-E48SX - page 5

    Li s t of M a t e r ia l s 3 MODEL: COK-ExxS 1 - Hood 1 - Bae Filter (2 on 48” model) 2 - 50W 120V Halogen Light Bulbs G U-10 2 - 40W 120V Appliance Bulbs 1 - Utensil Rail 2 - T elescopic Duct Covers 1 - Ceiling Mounting Bracket (pre attac hed to duct cover) 1 - W all Mounting Bracket 1-H A R D W A R EP A C K E T 7 - 2” W ood Screws 7 - Anch ...

  • Zephyr COK-E48SX - page 6

    www .zephyronline.com 4 I ns t a lla t io n - Duct wo rk C a lcula t io n S he e t Duct pieces To t a l Equivalent number length x used = 31 / 4 ”x1 0 ” Rect., straight 1 F t. x ( ) = Ft. 7” Round, straight 1 Ft. x ( ) = Ft. 31 / 4 ”x1 0 ” Rect. 90 0 elbow 15 Ft. x ( ) = Ft. 31 / 4 ”x1 0 ” Rect. 45 0 elb ow 9 Ft. x ( ) = Ft. 31 / 4 ? ...

  • Zephyr COK-E48SX - page 7

    5 I ns t a l l a t i o n - M o unt i ng H e i ght & C l e a ra nc e DUC T I N G 36" M in 96"-Max 124 ” M in 28"-Max 36" Min 32"-Max 52" 14 1/2" Minimum mount height between range top to hood bot- tom should be no less than 28". Maximum mount height should be no higher than 36". It is important to i ...

  • Zephyr COK-E48SX - page 8

    Installation - Ducting www .zephyronline.com side wall cap with gravity damper Soffit or crawl space Roof Pitch w/ Flashing & Cap 6 Soffit or crawl space External Blower External Blower W ARNING FIRE HAZARD NEVER exhaust air or terminate duct work into spaces between walls, crawl spaces, ceiling, attics, or garages. All exhaust must be ducted t ...

  • Zephyr COK-E48SX - page 9

    7 I n s t a lla tion - Sp ec ific at ion s R I H P E Z Y B N G I S E D G N E H C O G O L 19 3 / 4” 19 3/4” 10” 36” , 42” , 48 ” 22 5 / 8” 11 7 / 8” 95 ° 16 5/8” 13 3 / 8” 14 1 / 2” 15” 5" - 3 6 " 8" - 42" 31 / 2 " - 4 8 " 6" 9 3/16” ” 6 1 / 5 O 8 5/16” ” 8 / 1 4 R ” 2 3 / 1 1 4 R ...

  • Zephyr COK-E48SX - page 10

    www .zephyronline.com I ns t a lla t io n - In t e r n a l B l ow e r 8 The internal blower kit consists of the blower and capacitor box with wiring. 1. Position blower as shown. 2. Att ach blower to ange as shown using the provided 1/2” 5x15mm screws with washers. 3. P osition capacitor bo x as shown. 4. Secure capacitor bo x to hood using th ...

  • Zephyr COK-E48SX - page 11

    I n s t a lla tion - I n te r n al B lower 9 5. Remove existing grounding screw and att ach grounding wire from capacitor bo x. 6. Re-attach grounding screw to nish installation of capacitor box. Refer to Fig-A on previous page. 7 . Attach short capacitor connector to blower connector. 8. Att ach long capacitor connector to control board connect ...

  • Zephyr COK-E48SX - page 12

    www .zephyronline.com 10 I ns t a lla t io n - P re p a ring E xt e rn a l B lo we r The external blower kit consists of an 8” collar , and external blower wiring box. T he external blower is purchased separately . A T TE NTI O N The following are intructions on preparing your hood for installation with e xternal blower model CB E-1000. F or inst ...

  • Zephyr COK-E48SX - page 13

    11 6. Position cover onto external blower wiring box. 7 . Secure cover to box with provided screw . 8. Attach connector from external blower wiring bo x to control board box connector inside hood. 9. Attach grounding wire from external blower wiring bo x to grounding screw of the junction bo x. Refer on Fig-A in diagram below . 10. Final view of ex ...

  • Zephyr COK-E48SX - page 14

    A B min 28” max 36” C/L C/L 14 1/2” Duct Cover Ceiling Bracket 7 1/2” Attach screws to ceiling bracket C/L C 21” Duct Cover Ceiling Bracket www .zephyronline.com 1. Measure from cooking surface to hood bottom, level and mark line A. 2. Plum and mark center line. 3. Mark mounting height, line B (14 1/2” from line A). This is the top of t ...

  • Zephyr COK-E48SX - page 15

    13 In s t a l l a t i on - Mo u n t i n g H o o d gap between bracket and wall To p Bottom 1. Place wall brac ket on line C. P osition t o p of wall brac ket so it is even with the 21” mounting spread. Make sure bracket is atta c hed to wall as shown in the diagram. T he top of the wall bra c ket should have a gap between it and the wall. T he bo ...

  • Zephyr COK-E48SX - page 16

    www .zephyronline.com 14 I ns t a lla t io n - A t t a c hing U t e ns il R a il 1. Attac h utensil rail to hood canopy . A small hole has been pre-drilled into the canopy to provide a starting point to attach the rst utensil rail post. A fter the rst post is lined up with the hole, gently slide the rest of the rail onto the canopy . (note: b ...

  • Zephyr COK-E48SX - page 17

    15 2 3 4 6 1 5 The standard Baffle Filters are required to be cleaned frequently and as recommended in order to maintain blower efficiency . If improperly maintained, residue from cooking will sift through filters and cause damage to hood blowers and other sensitive components; and possibly clog duct work and create a fire hazard. Blower On/Off Dis ...

  • Zephyr COK-E48SX - page 18

    16 Filter Clean Reminder (Standard Bae Filters tted): A set of bae lters are tted by the factory . These Bae Filters are intended to lter out residue from cooking. T hey need not be replaced on a regular basis but are required to be kept clean. The Filter Clean Reminder function in the microprocessor will automatically indicate ...

  • Zephyr COK-E48SX - page 19

    17 M a i n t e n a n c e - C l e a n i n g S urface M aintenance : C l ean p eriodicall y w i t hh ot s oap y wate r a n d c l ean cotto n c l ot h . Do n ot use co rr os iv e o r ab r as iv e deter g en t , o r stee l woo l /scourin g p a ds whi c i i h will s cra t c h an d d amag e surface . F or h ea vi er so il use liquid de g rease r . A fte ...

  • Zephyr COK-E48SX - page 20

    18 Replacing Light Bulbs: CA UTION: Light bulbs become extremely hot when turned on. DO NO T tou c h bulbs until swit c hed o and cooled. T ouc hing hot bulbs may cause serious burns. Make sure all power is turned o and bulbs are not hot. Remove bulb by pressing both ends of the metal retaining clip togethe r , the light so c ket will now pro ...

  • Zephyr COK-E48SX - page 21

    19 T ro uble S ho o t ing After installation, the unit doesn’t work? Light works, but motor is not turning. The unit is vibrating. The motor is working, but the lights are not. The hood is not venting out properly . Filter is vibrating. After hood has been installed for a period of time, it stopped working. 1. The power source is not turned ON. 2 ...

  • Zephyr COK-E48SX - page 22

    20 www .zephyronline.com Part Desc r iption P art# Halogen Bulb G U-10, 120V, 50W Z0B-0020 Incadescent Bulb T29 127V 40 W Z0B-0003 Internal Blower, 600 cfm CBI-600 External Blower, 1000 cfm CBE-1000 Duct Cover Extension Kit Z1C-00OK Accessory Desc r iption P art# List of Parts and Accessories ...

  • Zephyr COK-E48SX - page 23

    www.zephyronline.com Warranty One Y ear Service Repair W arranty: F or one year from date of original purchase, we will provide free of charge, service lab or to repair any failed parts or components due to manufacturing defects. T wo Y ears Parts W arr anty: F or two years from date of original purchase, we will provide free of charge, nonconsumab ...

Производитель Zephyr Категория Ventilation Hood

Документы, которые мы получаем от производителя устройства Zephyr COK-E48SX мы можем разделить на несколько групп. Это в частности:
- технические чертежи Zephyr
- инструкции обслуживания COK-E48SX
- паспорта изделия Zephyr
- информационные брошюры
- энергетические этикетки Zephyr COK-E48SX
Все из них важны, однако самую важную информацию с точки зрения пользователя мы найдем в инструкции обслуживания Zephyr COK-E48SX.

Группа документов, определяемая как инструкции обслуживания, делится также на более подробные типы, такие как: Инструкции монтажа Zephyr COK-E48SX, инструкции обслуживания, короткие инструкции или инструкции пользователя Zephyr COK-E48SX. В зависимости от потребностей, Вам необходимо поискать требуемый документ. На нашем сайте Вы можете просмотреть самую популярную инструкцию использования изделия Zephyr COK-E48SX.

Похожие инструкции обслуживания

Полная инструкция обслуживания устройства Zephyr COK-E48SX, как должна выглядеть?
Инструкция обслуживания, определяемая также как пособие пользователя, или просто "руководство" - это технический документ, цель которого заключается в использовании Zephyr COK-E48SX пользователями. Инструкции пишет, как правило технический писатель, языком, доступным для всех пользователей Zephyr COK-E48SX.

Полная инструкция обслуживания Zephyr, должна заключать несколько основных элементов. Часть из них менее важная, как например: обложка / титульный лист или авторские страницы. Однако остальная часть, должна дать нам важную с точки зрения пользователя информацию.

1. Вступление и рекомендации, как пользоваться инструкцией Zephyr COK-E48SX - В начале каждой инструкции, необходимо найти указания, как пользоваться данным пособием. Здесь должна находится информация, касающаяся местонахождения содержания Zephyr COK-E48SX, FAQ и самых распространенных проблем - то есть мест, которые чаще всего ищут пользователи в каждой инструкции обслуживания
2. Содержание - индекс всех советов, касающихся Zephyr COK-E48SX, которое найдем в данном документе
3. Советы по использованию основных функций устройства Zephyr COK-E48SX - которые должны облегчить нам первые шаги во время использования Zephyr COK-E48SX
4. Troubleshooting - систематизированный ряд действия, который поможет нам диагностировать а в дальнейшем очередность решения важнейших проблем Zephyr COK-E48SX
5. FAQ - чаще всего задаваемые вопросы
6. Контактные данные Информация о том, где искать контактные данные производителя / сервисного центра Zephyr COK-E48SX в данной стране, если самостоятельно не получится решить проблему.

У вас вопрос, касающийся Zephyr COK-E48SX?

Воспользуйтесь формуляром, находящимся ниже

Если с помощью найденной инструкции Вы не решили свою проблему с Zephyr COK-E48SX, задайте вопрос, заполнив следующий формуляр. Если у какого то из пользователей была похожая проблема с Zephyr COK-E48SX со всей вероятностью он захочет поделиться методом ее решения.

Перепишите текст с картинки

Комментарии (0)