Инструкция обслуживания Patton electronic 3012/V24, 3014/V24, 3018/V24

16 страниц 0.19 mb
Скачать

Перейти на страницу of 16

Summary
  • Patton electronic 3012/V24, 3014/V24, 3018/V24 - page 1

    Doc #: 137001UA Part #: 07M3012-A M ODEM S HARING D EVICE 3012/V24 (CTS MSD-2C) 3014/V24 (CTS MSD-4C) 3018/V24 (CTS MSD-8C) I NST ALLA TION AND O PERA TIONS M ANUAL B An ISO-9001 Certified Company Copyright© 2000 Patton Electronics Co., All Rights Reserved January 3, 2000 ...

  • Patton electronic 3012/V24, 3014/V24, 3018/V24 - page 2

    Doc #: 137001UA Part #: 07M3012-A M ODEM S HARING D EVICE 3012/V24 (CTS MSD-2C) 3014/V24 (CTS MSD-4C) 3018/V24 (CTS MSD-8C) I NST ALLA TION AND O PERA TIONS M ANUAL B An ISO-9001 Certified Company Copyright© 2000 Patton Electronics Co., All Rights Reserved ...

  • Patton electronic 3012/V24, 3014/V24, 3018/V24 - page 3

    137001UA i P ATTON E LECTRONICS C O .I NSTALLATION A ND O PERATIONS M ANUAL 3012-14-18/V24 COPYRIGHT NOTICE Copyright© 2000 Patton Electronics Co., All Rights Reserved. PROPRIET ARY NOTICE The information contained herein is proprietary and confidential to Patton Electronics Co. Any reproduction or redistribution of this publication, in whole or i ...

  • Patton electronic 3012/V24, 3014/V24, 3018/V24 - page 4

    137001UA iii P ATTON E LECTRONICS C O .I NSTALLATION A ND O PERATIONS M ANUAL 3012-14-18/V24 T able of Contents CHAPTER 1 - OPERA TON Channel Selection Modes (4 and 8 port only) .................................................. 1- 2 Anti-Streaming ............................................................................................ 1 -2 Fro ...

  • Patton electronic 3012/V24, 3014/V24, 3018/V24 - page 5

    137001UA 1-1 Operation P ATTON E LECTRONICS C O .I NSTALLATION A ND O PERATIONS M ANUAL 3012-14-18/V24 CHAPTER 1 - OPERA TON The Patton MSDs are network enhancement accessories intended for DCE sharing applications. The Patton MSDs allows up to eight terminals or DTE devices to share a single point to point or multi-drop polled communication link. ...

  • Patton electronic 3012/V24, 3014/V24, 3018/V24 - page 6

    137001UA 1-2 Operation P ATTON E LECTRONICS C O .I NSTALLATION A ND O PERATIONS M ANUAL 3012-14-18/V24 Channel Selection Modes (4 and 8 port only) The Patton MSD provides two selectable sub-channel service modes of operation: Scanning Mode and Priority Mode. Depending on system requirements, either mode may be selected by internal DIP switch settin ...

  • Patton electronic 3012/V24, 3014/V24, 3018/V24 - page 7

    137001UA 1-3 Operation P ATTON E LECTRONICS C O .I NSTALLATION A ND O PERATIONS M ANUAL 3012-14-18/V24 Front Panel Indicators and Switches The front panel LED indicators associated with each sub-channel identify the active port. A green POWER ON LED indicates when AC voltage is applied. Two adjacent green LED indicators illuminate in union with ind ...

  • Patton electronic 3012/V24, 3014/V24, 3018/V24 - page 8

    137001UA 2-1 Setup & Installation P ATTON E LECTRONICS C O . 3012-14-18/V24 I NSTALLATION A ND O PERATIONS M ANUAL Power Connection Before connecting the MSD to an AC power source the top cover must be installed and secured with the supplied screws. The unit is supplied with a 110/220V voltage switch. Turn the switch with a coin or screw driver ...

  • Patton electronic 3012/V24, 3014/V24, 3018/V24 - page 9

    137001UA 2-2 Setup & Installation 3012-14-18/V24 I NSTALLATION A ND O PERATIONS M ANUAL P ATTON E LECTRONICS C O . JP4 and JP5 to IN IN IN IN IN Provided Pin 9 and 10 Test Voltage JP6 to OUT OUT OUT OUT OUT CTS delay = No Delay JP1, JP2 and JP3 to IN IN IN IN IN Factory Test Jumpers must be installed 3018/V24 (CTS MSD-8C) Switch 9 - positions 4 ...

  • Patton electronic 3012/V24, 3014/V24, 3018/V24 - page 10

    137001UA 2-3 Setup & Installation P ATTON E LECTRONICS C O . 3012-14-18/V24 I NSTALLATION A ND O PERATIONS M ANUAL Installation Select an appropriate location accessible to and within six feet of an AC power outlet. The outlet must have a ground pin receptacle for product warranty. The DCE- to-DTE cabling between each attached device and the MS ...

  • Patton electronic 3012/V24, 3014/V24, 3018/V24 - page 11

    137001UA 2-4 Setup & Installation 3012-14-18/V24 I NSTALLATION A ND O PERATIONS M ANUAL P ATTON E LECTRONICS C O . Switching Mode Selection (Switch Pos 5) 3014/V24 (CTS MSD-4C) & 3018/ V24 (CTS MSD-8C) Only To select Priority Mode, set switch position 5 to ON ON ON ON ON . To select Scanning Mode, set switch position 5 to OFF OFF OFF OFF OF ...

  • Patton electronic 3012/V24, 3014/V24, 3018/V24 - page 12

    137001UA A-1 Appendix P ATTON E LECTRONICS C O .I NSTALLATION A ND O PERATIONS M ANUAL 3012-14-18/V24 Applications Multiple Sync/Async devices operating in a polled environment, sharing one RS-232 DCE interface Capacity One to Eight RS-232 Synch/Async Terminals; Standard DB-25 V.24 (female) connectors for each channel Data Format Data transparent a ...

  • Patton electronic 3012/V24, 3014/V24, 3018/V24 - page 13

    137001UA A-2 Appendix P ATTON E LECTRONICS C O .I NSTALLATION A ND O PERATIONS M ANUAL 3012-14-18/V24 Typical Application RS-232 Pin Out Leased or Dial L ine V.24 MOD EM V.24 V.24 V.24 V.24 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 Sh i el d ( c om m o n) Tr a ns m i t D a t a ( f r om D T E) Re c e i v e D a t a ( f r o m D ...

  • Patton electronic 3012/V24, 3014/V24, 3018/V24 - page 14

    137001UA A-3 Appendix P ATTON E LECTRONICS C O .I NSTALLATION A ND O PERATIONS M ANUAL 3012-14-18/V24 JP2 JP3 JP4 JP5 +8 V -8V Ne g at ive Te s t Volt a g e P osi t ive Te s t Volt a g e A nt i - St r eam T im er A n t i-Stream E n able=ON / Disa bl e= OF F Si g nal t o C ha ss is Ground ON OFF 1 2 3 4 5 6 SW3 3012/ V24 (C T S M SD - 2C) CTS D elay ...

  • Patton electronic 3012/V24, 3014/V24, 3018/V24 - page 15

    137001UA A-4 Appendix P ATTON E LECTRONICS C O .I NSTALLATION A ND O PERATIONS M ANUAL 3012-14-18/V24 JP1 JP2 JP3 JP4 JP 5 +5 V +8 V -8V Ne g at ive Te s t Volt a g e P osi t ive Te s t Volt a g e A nt i - St r eam T im er A n ti- S t r eam E n able=ON/Disable= O F F P r i or i t y M ode= O N/ Sc an Mode= OF F Si g nal t o C ha ss is Grou nd ON OFF ...

  • Patton electronic 3012/V24, 3014/V24, 3018/V24 - page 16

    B 7622 Rickenbacker Drive Gaithersburg, MD 20879 Sales: 301 975-1000 Suppor t: 301 975-1007 W eb Address: www .patton.com ...

Производитель Patton electronic Категория Network Card

Документы, которые мы получаем от производителя устройства Patton electronic 3012/V24, 3014/V24, 3018/V24 мы можем разделить на несколько групп. Это в частности:
- технические чертежи Patton electronic
- инструкции обслуживания 3012/V24, 3014/V24, 3018/V24
- паспорта изделия Patton electronic
- информационные брошюры
- энергетические этикетки Patton electronic 3012/V24, 3014/V24, 3018/V24
Все из них важны, однако самую важную информацию с точки зрения пользователя мы найдем в инструкции обслуживания Patton electronic 3012/V24, 3014/V24, 3018/V24.

Группа документов, определяемая как инструкции обслуживания, делится также на более подробные типы, такие как: Инструкции монтажа Patton electronic 3012/V24, 3014/V24, 3018/V24, инструкции обслуживания, короткие инструкции или инструкции пользователя Patton electronic 3012/V24, 3014/V24, 3018/V24. В зависимости от потребностей, Вам необходимо поискать требуемый документ. На нашем сайте Вы можете просмотреть самую популярную инструкцию использования изделия Patton electronic 3012/V24, 3014/V24, 3018/V24.

Похожие инструкции обслуживания

Полная инструкция обслуживания устройства Patton electronic 3012/V24, 3014/V24, 3018/V24, как должна выглядеть?
Инструкция обслуживания, определяемая также как пособие пользователя, или просто "руководство" - это технический документ, цель которого заключается в использовании Patton electronic 3012/V24, 3014/V24, 3018/V24 пользователями. Инструкции пишет, как правило технический писатель, языком, доступным для всех пользователей Patton electronic 3012/V24, 3014/V24, 3018/V24.

Полная инструкция обслуживания Patton electronic, должна заключать несколько основных элементов. Часть из них менее важная, как например: обложка / титульный лист или авторские страницы. Однако остальная часть, должна дать нам важную с точки зрения пользователя информацию.

1. Вступление и рекомендации, как пользоваться инструкцией Patton electronic 3012/V24, 3014/V24, 3018/V24 - В начале каждой инструкции, необходимо найти указания, как пользоваться данным пособием. Здесь должна находится информация, касающаяся местонахождения содержания Patton electronic 3012/V24, 3014/V24, 3018/V24, FAQ и самых распространенных проблем - то есть мест, которые чаще всего ищут пользователи в каждой инструкции обслуживания
2. Содержание - индекс всех советов, касающихся Patton electronic 3012/V24, 3014/V24, 3018/V24, которое найдем в данном документе
3. Советы по использованию основных функций устройства Patton electronic 3012/V24, 3014/V24, 3018/V24 - которые должны облегчить нам первые шаги во время использования Patton electronic 3012/V24, 3014/V24, 3018/V24
4. Troubleshooting - систематизированный ряд действия, который поможет нам диагностировать а в дальнейшем очередность решения важнейших проблем Patton electronic 3012/V24, 3014/V24, 3018/V24
5. FAQ - чаще всего задаваемые вопросы
6. Контактные данные Информация о том, где искать контактные данные производителя / сервисного центра Patton electronic 3012/V24, 3014/V24, 3018/V24 в данной стране, если самостоятельно не получится решить проблему.

У вас вопрос, касающийся Patton electronic 3012/V24, 3014/V24, 3018/V24?

Воспользуйтесь формуляром, находящимся ниже

Если с помощью найденной инструкции Вы не решили свою проблему с Patton electronic 3012/V24, 3014/V24, 3018/V24, задайте вопрос, заполнив следующий формуляр. Если у какого то из пользователей была похожая проблема с Patton electronic 3012/V24, 3014/V24, 3018/V24 со всей вероятностью он захочет поделиться методом ее решения.

Перепишите текст с картинки

Комментарии (0)