Инструкция обслуживания AEG Protect A.500

18 страниц 1.7 mb
Скачать

Перейти на страницу of 18

Summary
  • AEG Protect A.500 - page 1

    1 PROTEC T A. PROTEC T A. PROTEC T A. PROTEC T A. PROTECT A. 500 PROTECT A. 700 OPERATING INS TRUCTION UPS ...

  • AEG Protect A.500 - page 2

    2 1 Notes on these Operating Instructions Duty to Provide Information Th e se o p e r at i n g i n st r u c t io n s w i l l h el p y o u to i n st a l l a n d op er a te th e U ni n te rr u pt i b l e P ow e r S up pl y ( UP S ), PR OT E C T A . 5 0 0 o r P RO TE C T A. 7 0 0, a l l r e fe r re d t o as P R OT EC T A . i n t hi s d o c u me n t, s ...

  • AEG Protect A.500 - page 3

    3 etc. entered into b y AEG and its repr esentatives without prior notification in the event of maintenance an d repair work being carried out with an ything other than orig inal AEG s pare parts or spare parts purc hased by AEG. Handling PROTECT A. is design ed an d cons tructed so that all necessar y steps for start-up and operation can be perfor ...

  • AEG Protect A.500 - page 4

    4 1.1 Declaration of Conformity ...

  • AEG Protect A.500 - page 5

    5 2 Safety 2.1 Important Safety Instructions Read these operatin g instructions c arefull y prior to commiss ioning of the PROT ECT A . UPS and observe th e safety instructions! Only use the unit if it is in a technica lly perfect condition and always in accordance with its intended purpose, while being aware of s afety and dang er aspects , and in ...

  • AEG Protect A.500 - page 6

    6 The outpu t m ay be live, e ven if the U PS is not connected to th e m ains supply, as the U PS has its own internal po wer suppl y (battery)! For hea lth a nd saf ety r easons, the u nit m ust be earthed correctl y! PROTECT A. may only be o perated with or connec ted to a 230 VAC mains with protective grounding usin g a mains connection cable wi ...

  • AEG Protect A.500 - page 7

    7 ♦ Never connect the m ains input to the UP S output! ♦ Ensure that no fluids or for eign bodies can p enetrate the UPS! ♦ Do not block the side air vents of the unit! Keep children awa y from the unit and ens ure that objects are never inserted throu gh the vents! ♦ Do not connect household appliances such as hairdryers to the UP S! ♦ T ...

  • AEG Protect A.500 - page 8

    8 Batteries can cause elec tric shocks and high short-circuit currents. Therefor e, take the follo wing s afety precautions when work ing with batteries: ♦ Take off watches, rings and other metallic o bjects! ♦ Always use tools with insu lated handl es! For personal saf ety reasons , never switch on th e main switch when t he mains connector of ...

  • AEG Protect A.500 - page 9

    9 3 System Descrip tion i P R OTE C T A. i s an u n i n te rr up ti bl e p ow e r su pp ly ( U P S ) fo r es se nt i a l lo ad s su ch as p e rs o na l c o mpu t e rs ( P Cs ) o r t el ec om mu ni ca ti on eq ui p me nt a nd si mi l a r d ev i ce s. I t co ns is ts o f: ♦ Mains filter in the m ains input incl. m ains energy backfeed protect ion ? ...

  • AEG Protect A.500 - page 10

    10 d ou b l e m ai ns fi lt e rs w h i ch pr ov id e e f f e cti ve pr ot ec ti o n ag ai ns t ma in s v o l t a g e p e a ks a n d h ig h - f re qu en cy f au l ts . In c ase of sustained m ains undervo ltage or ov ervoltage within defined ranges, the a utom atic voltage regulator ( A.V.R.) further stabilises the load volta ge. A s a result, volta ...

  • AEG Protect A.500 - page 11

    11 4 Set-Up and Oper ation Installing the UPS is as easy as follo wing the steps sho wn. 4.1 Inspection Remove the UPS f rom its pack aging and i nspect it for damage that ma y have oc curred during shipping. If an y damage is discovered, repack the unit a nd retur n i t to th e place of purchase. 4.2 Placement I n s t a l l t h e U P S u n i t i n ...

  • AEG Protect A.500 - page 12

    12 4.3 Charging This unit is shipped from the f actor y with its internal batter y fully c harged, however, som e power m ay be lost during shipping and the batter y s hould b e recharged prior to use. Plug the un it into an a ppropriate p ower suppl y and al low the UPS to c harge fully b y leaving it plugged in for at least 4 hours with no load ( ...

  • AEG Protect A.500 - page 13

    13 Use one more internet line cable and p lug one end of the internet line cab le to the “Out” s ock et at t he bac k of the PROTECT A. UPS. Plug t he other end of the modem input socket as sho wn below. 4.6 USB and serial cable connection To allow f or unattended s ystem shutdown f or your operating system, c onnect th e USB or the RS232 seria ...

  • AEG Protect A.500 - page 14

    14 After r emoving th e f ront c over, follow F ig. 2 above to rem ove partition by unsc rewing i t. Then follow Fi g. 3 to remove t he battery. 4.10 Shutdown- and UPS management soft ware The "Compu W atch" software s peciall y d eveloped for t hese purposes by AEG continuo usly check s the mains supply and the UPS status. Fig. 1 Fig. 2 ...

  • AEG Protect A.500 - page 15

    15 In conjunction with the "intelligent" UPS, th is ensures that the availability o f I T components and data security are guaranteed. The "CompuW atch" shutdo wn software sup ports diff erent operating systems: W indows 98SE/ME, W indows NT /2000/ XP, Linux SUSE, Linux RedHat , Nove ll NetW are, IBM AIX, HP-UX, SUN Sol aris, Ma ...

  • AEG Protect A.500 - page 16

    16 5.1 Specifications MODEL PROTECT A. 500 PROTECT A. 700 Ty pe p o we r 500 VA / 300 W 700 VA / 420 W Input voltage 220 Vac / 230 Vac / 240 Vac Input voltage range without battery mode 150 – 280 Vac U PS - in p u t Frequency (auto selection) 50 / 60 Hz ± 5 Hz Rated output voltage /AVR-technology 220 Vac / 230 Vac / 240 Vac Rated output voltage ...

  • AEG Protect A.500 - page 17

    17 6 T rouble shooting Symptom Cause Remedy Missing battery Charge battery up to 4 hours Battery fault Replace with the same type of battery No LED display on the front pa nel Power sw itch not pressed Turn on the sw itch again A larm buzzer beeps continuously when A C supply is normal UPS overload Verify that the load m atches the UPS capability a ...

  • AEG Protect A.500 - page 18

    18 Guarantee certificate T y pe: …….…… ……………....... ................................ ............... Serial-no.: ………… …………..…… ………............. .................. Date of purchase: … …………........... ..…………………… ........ Trading stam p / Signature Specifications are subject to chan ...

Производитель AEG Категория Power Supply

Документы, которые мы получаем от производителя устройства AEG Protect A.500 мы можем разделить на несколько групп. Это в частности:
- технические чертежи AEG
- инструкции обслуживания Protect A.500
- паспорта изделия AEG
- информационные брошюры
- энергетические этикетки AEG Protect A.500
Все из них важны, однако самую важную информацию с точки зрения пользователя мы найдем в инструкции обслуживания AEG Protect A.500.

Группа документов, определяемая как инструкции обслуживания, делится также на более подробные типы, такие как: Инструкции монтажа AEG Protect A.500, инструкции обслуживания, короткие инструкции или инструкции пользователя AEG Protect A.500. В зависимости от потребностей, Вам необходимо поискать требуемый документ. На нашем сайте Вы можете просмотреть самую популярную инструкцию использования изделия AEG Protect A.500.

Похожие инструкции обслуживания

Полная инструкция обслуживания устройства AEG Protect A.500, как должна выглядеть?
Инструкция обслуживания, определяемая также как пособие пользователя, или просто "руководство" - это технический документ, цель которого заключается в использовании AEG Protect A.500 пользователями. Инструкции пишет, как правило технический писатель, языком, доступным для всех пользователей AEG Protect A.500.

Полная инструкция обслуживания AEG, должна заключать несколько основных элементов. Часть из них менее важная, как например: обложка / титульный лист или авторские страницы. Однако остальная часть, должна дать нам важную с точки зрения пользователя информацию.

1. Вступление и рекомендации, как пользоваться инструкцией AEG Protect A.500 - В начале каждой инструкции, необходимо найти указания, как пользоваться данным пособием. Здесь должна находится информация, касающаяся местонахождения содержания AEG Protect A.500, FAQ и самых распространенных проблем - то есть мест, которые чаще всего ищут пользователи в каждой инструкции обслуживания
2. Содержание - индекс всех советов, касающихся AEG Protect A.500, которое найдем в данном документе
3. Советы по использованию основных функций устройства AEG Protect A.500 - которые должны облегчить нам первые шаги во время использования AEG Protect A.500
4. Troubleshooting - систематизированный ряд действия, который поможет нам диагностировать а в дальнейшем очередность решения важнейших проблем AEG Protect A.500
5. FAQ - чаще всего задаваемые вопросы
6. Контактные данные Информация о том, где искать контактные данные производителя / сервисного центра AEG Protect A.500 в данной стране, если самостоятельно не получится решить проблему.

У вас вопрос, касающийся AEG Protect A.500?

Воспользуйтесь формуляром, находящимся ниже

Если с помощью найденной инструкции Вы не решили свою проблему с AEG Protect A.500, задайте вопрос, заполнив следующий формуляр. Если у какого то из пользователей была похожая проблема с AEG Protect A.500 со всей вероятностью он захочет поделиться методом ее решения.

Перепишите текст с картинки

Комментарии (0)