Инструкция обслуживания Haier AD092AMBHA

24 страниц 0.65 mb
Скачать

Перейти на страницу of 24

Summary
  • Haier AD092AMBHA - page 1

    Operation & Installation Manual No. 0010572410 D DUCT TYPE AIR CONDITIONING AD122AMBHA AU122AABHA (HDU-12HA03/M(R1)(B)) AD092AMBHA AU092AABHA (HDU-09HA03/M(R1)(B)) ...

  • Haier AD092AMBHA - page 2

    1 T ABLE OF CONTENTS MALFUNCTION 7-8 CARE AND MAINTENANCE 9-10 INST ALLA TION MANUAL FOR OUTDOOR UNIT 1 1-14 INST ALLA TION MANUAL FOR INDOOR UNIT 15-20 SAFETY PRECAUTIONS 3-5 P ARTS AND FUNCTIONS 6 CAUTIONS 2 INST ALLA TION MANUAL FOR ELECTRIC WIRING 21 INST ALLA TION MANUAL FOR WIRE CONTROLLER 22 CHECK AND TEST RUN 23 ...

  • Haier AD092AMBHA - page 3

    CAUTIONS 2 All electrical ropairs must be carried out by qualified electricians. Inadequate repairs may result in a major source of danger for the user of the air conditoiner . Do not damage any parts of the air conditioner that carry refrigerant by piercing or perforating the air conditioner's tubes with sharp or pointed items, crushing or tw ...

  • Haier AD092AMBHA - page 4

    SAFETY PRECAUTIONS Before starting to use the system, read carefully this"SAFETY PRECAUTIONS" to ensure a proper operation of the system. Safety precautions described here are classified to " W ARNING" and " CAUTION". Precautions which are shown in the column of " W ANING" means that an improper handing could ...

  • Haier AD092AMBHA - page 5

    SAFETY PRECAUTIONS 4 CAUTION Do not wash the air conditioner with water . Do not install the system where the air outlet reaches directly the flora and fauna. Make sure to use a fuse of proper electric rating. Do not operate the system while the air outlet grill is removed. It is strictly prohibited to place a container of combustible gas or liquid ...

  • Haier AD092AMBHA - page 6

    SAFETY PRECAUTIONS 5 2. If the supply cord is damaged, it must be replaced by the manufacturer or its service agent or a similar qualified person. An extend cord is not recommended, the requirement of the power supply cord is H07RN-F 3G 2.5 mm 2 (suitable for installation in European region) 3. If the fuse on PC board is broken please change it wit ...

  • Haier AD092AMBHA - page 7

    P ARTS AND FUNCTIONS 6 Indoor Unit Outdoor Unit Motor(inside) Fan(inside) Air inlet Air outlet Drain hose Connecting piping and electrical wiring ...

  • Haier AD092AMBHA - page 8

    7 please check the following things about your air conditioner before making a servie call. MALFUNCTION Flickering F1 Note: This unit has a function of automatic restart system after recovering power stoppage. Please contact the sales dealer if it is not required. Content of defect F2 The trouble of the room temp.sensor F4 The trouble of the pipe t ...

  • Haier AD092AMBHA - page 9

    8 MALFUNCTION The followings are not malfunction Shuru Shuru When the air conditioner is started, when the compressor starts or stops during operation or when the air conditioner is stopped, it sometimes sounds "shuru shuru" or "gobo gobo". It is the flowing sound of the refrigerant, and it is not a trouble. W ater flowing sound ...

  • Haier AD092AMBHA - page 10

    9 CARE AND MAINTENANCE Points to observe T urn off the power supply switch. Do not touch with wet hand. Do not use hot water or volatileliquid. ON OFF Thinner Do not use! Benzine T ooth powder Cleaning 1. Clean the air filter by lightly tapping it or with the cleaner . It is more effective to clean the air filter with water . If the air filter is v ...

  • Haier AD092AMBHA - page 11

    10 "HOT KEEP"is operated in the following cases. When heating is started: In order to prevent blowing out of cool wind, the indoor unit fan stopped according to the room temperature which heating operation is started. W ait for approx. 2 to 3 minute, and the operation will be automatically changed to the ordinary heating mode. Defrosting ...

  • Haier AD092AMBHA - page 12

    1 1 For inspection and maintenance When you change your address or the installation place Electric work Confirm the following items for safe and comfortable use of air conditioner . The installation work is to be burden on the sales dealer , and do not conduct it by yourself. Installation place A void installing the air conditioner near the place w ...

  • Haier AD092AMBHA - page 13

    INST ALLA TION MANUAL FOR OUTDOOR UNIT Edging (2) Installation where the area with strong winds. Install the unit so that the air outlet section of the unit must NOT be faced toward wind direction. (1) Open space requirement around the unit 2. Selection of the place of installation 1. Accessories "Edging" for protection of electric wires ...

  • Haier AD092AMBHA - page 14

    13 INST ALLA TION MANUAL FOR OUTDOOR UNIT (1) Outline piping 4. Refrigerant piping (2) Piping size (3) Limitations for one way piping length and vertical height One way piping length: less than 15m. 90 + 0.5 Install the removed flared nuts to the pipes to be connected, then flare the pipes. Precautions for refrigerant piping Gas piping Liquid pipin ...

  • Haier AD092AMBHA - page 15

    14 INST ALLA TION MANUAL FOR OUTDOOR UNIT 7 90 for 6 sec. 4 (5) Purging method ( the refrigerant is R407C) If it does not stop gas leakage, discharge whole refrigerants from the serice port. After flaring work again and vacuumize, fill up prescribed refrigerant from the gas cylinder . Detach the charge hose from the service port, open 3-way valve a ...

  • Haier AD092AMBHA - page 16

    15 INST ALLA TION MANUAL FOR INDOOR UNIT 1. Safety precautions W ARNING Please read these "Safety Precautions" first then accurately execute the installation work. Though the precautionary points indicated herein are divided under two headings, and , those points which are related to the strong possibility of an installation done in error ...

  • Haier AD092AMBHA - page 17

    16 INST ALLA TION MANUAL FOR INDOOR UNIT NOTICE All Wiring of this installation must comply with NA TIONAL, ST A TE AND LOCAL REGULA TIONS . These instructions do not cover all variations for every kind of installation circumstance. Should further information be desired or should particular problems occur , the matter should be referred to your loc ...

  • Haier AD092AMBHA - page 18

    17 INST ALLA TION MANUAL FOR INDOOR UNIT (4) Preparation for suspending the unit There should be no obstacles within 250 (a) Figure of installation dimension: (unit: mm) When install the duct hidden type indoor unit, the return air box must be designed and installed, as Figure3, Figure4. The distance between the air outlet of duct and the air outle ...

  • Haier AD092AMBHA - page 19

    18 INST ALLA TION MANUAL FOR INDOOR UNIT 28 B C Air outlet grille T op panel of unit C amplified Use screw to fix top panel (Figure 6) B Air supply passage Rivet Unit M8 screw nut M8 wide expansion screw bolt (Figure 5) A amplified B amplified Air supply passage B M8 wide lock washer M8 hoisting screw Install the hoisting screw * Use M8 or M10 hois ...

  • Haier AD092AMBHA - page 20

    19 INST ALLA TION MANUAL FOR INDOOR UNIT Angle steel for support Hoisting screw Suspending bolt Requirements: The indoor side drain hose should be thermal insulated. The parts connected with indoor unit should be thermal insulated. Improper thermal insulation may cause dew-forming phenomenon. The drain hose should be downwards slant (over 1/100) an ...

  • Haier AD092AMBHA - page 21

    20 INST ALLA TION MANUAL FOR INDOOR UNIT Material of connection pipe and thermal insulation Foam polyethylene pipe, thickness over 10mm Stiff PVC pipe VP 20mm (inside diameter) Material of connection pipe Material of thermal insulation W arning ! Perform with two spanners Depenbing on the outdoor unit.For details,please refer to the operation manua ...

  • Haier AD092AMBHA - page 22

    21 INST ALLA TION MANUAL FOR ELECTRIC WIRING 1(L) Cautions: Use copper wire only .Parameters of connecting line : H05RN-F 4G0.75mm 2 Power supply :1PH,220-230V~,50Hz, connect from outside. Wiring methods: 1.Wiring method of ring terminal For connecting line which end is a ring,its wiring method as shown in the right figure: remove wiring screw and ...

  • Haier AD092AMBHA - page 23

    22 INST ALLA TION MANUAL FOR WIRE CONTROLLER 1.Remove the upper cover of wire contr oller The PC board is installed on the back cover of wire controller . When remove the upper cover , pay attention not to damage PC board. 2.Install wire contr oller ** Drill 2 wall holes according to the position of the 2 screw holes on the back * cover of wire con ...

  • Haier AD092AMBHA - page 24

    23 CHECK AND TEST RUN Other instruction 1. Set of the air sending of the fan motor Before leaving factory , the rotation speed of fan motor has already been set at standard choice. When the indoor unit uses free air sending and not needing to connect with duct, the fan speed of indoor unit is set at standard choice. When the indoor unit needs to co ...

Производитель Haier Категория Air Conditioner

Документы, которые мы получаем от производителя устройства Haier AD092AMBHA мы можем разделить на несколько групп. Это в частности:
- технические чертежи Haier
- инструкции обслуживания AD092AMBHA
- паспорта изделия Haier
- информационные брошюры
- энергетические этикетки Haier AD092AMBHA
Все из них важны, однако самую важную информацию с точки зрения пользователя мы найдем в инструкции обслуживания Haier AD092AMBHA.

Группа документов, определяемая как инструкции обслуживания, делится также на более подробные типы, такие как: Инструкции монтажа Haier AD092AMBHA, инструкции обслуживания, короткие инструкции или инструкции пользователя Haier AD092AMBHA. В зависимости от потребностей, Вам необходимо поискать требуемый документ. На нашем сайте Вы можете просмотреть самую популярную инструкцию использования изделия Haier AD092AMBHA.

Похожие инструкции обслуживания

Полная инструкция обслуживания устройства Haier AD092AMBHA, как должна выглядеть?
Инструкция обслуживания, определяемая также как пособие пользователя, или просто "руководство" - это технический документ, цель которого заключается в использовании Haier AD092AMBHA пользователями. Инструкции пишет, как правило технический писатель, языком, доступным для всех пользователей Haier AD092AMBHA.

Полная инструкция обслуживания Haier, должна заключать несколько основных элементов. Часть из них менее важная, как например: обложка / титульный лист или авторские страницы. Однако остальная часть, должна дать нам важную с точки зрения пользователя информацию.

1. Вступление и рекомендации, как пользоваться инструкцией Haier AD092AMBHA - В начале каждой инструкции, необходимо найти указания, как пользоваться данным пособием. Здесь должна находится информация, касающаяся местонахождения содержания Haier AD092AMBHA, FAQ и самых распространенных проблем - то есть мест, которые чаще всего ищут пользователи в каждой инструкции обслуживания
2. Содержание - индекс всех советов, касающихся Haier AD092AMBHA, которое найдем в данном документе
3. Советы по использованию основных функций устройства Haier AD092AMBHA - которые должны облегчить нам первые шаги во время использования Haier AD092AMBHA
4. Troubleshooting - систематизированный ряд действия, который поможет нам диагностировать а в дальнейшем очередность решения важнейших проблем Haier AD092AMBHA
5. FAQ - чаще всего задаваемые вопросы
6. Контактные данные Информация о том, где искать контактные данные производителя / сервисного центра Haier AD092AMBHA в данной стране, если самостоятельно не получится решить проблему.

У вас вопрос, касающийся Haier AD092AMBHA?

Воспользуйтесь формуляром, находящимся ниже

Если с помощью найденной инструкции Вы не решили свою проблему с Haier AD092AMBHA, задайте вопрос, заполнив следующий формуляр. Если у какого то из пользователей была похожая проблема с Haier AD092AMBHA со всей вероятностью он захочет поделиться методом ее решения.

Перепишите текст с картинки

Комментарии (0)