Инструкция обслуживания Acroprint Data Collection Terminal DC7000

36 страниц 0.25 mb
Скачать

Перейти на страницу of 36

Summary
  • Acroprint Data Collection Terminal DC7000 - page 1

    DC7000 Dat a Collection T erminal Hardwar e Manual ...

  • Acroprint Data Collection Terminal DC7000 - page 2

    2 FCC Warning: Note: This equ i pment has bee n tested and fo und to com ply with th e limits f or a Cl ass A digital device, pursuant to Part 15 of the FCC rules. These lim its are designed to provide reasonabl e prot ection agains t harmful i nterfer ence when the e quipment is operat ed in a commer cial envi ronment . This e quipment genera tes, ...

  • Acroprint Data Collection Terminal DC7000 - page 3

    3 The telephone c ompany may make change s in its facil ities, equipment, operations or procedure s that coul d aff ect the ope rati on of the equipment. If this happens the tele phone company will provide advanc e noti c e in orde r for you to make n ecessar y mod ifications to mainta in uninterru pted serv ice. If troubl e is experience d with th ...

  • Acroprint Data Collection Terminal DC7000 - page 4

    4 Declar ation Of Conf ormity Accordi ng To EMC Di rective 89/ 336/EEC We declare under our sole responsibi lity that the DC7000 magnetic stripe and/or barc ode readin g and/or d ata recordin g equipm ent to which this dec laration relates a re in conformity with the following sta ndards: EN61000-6-1, EN55022-1998 with Amendmen t A1: 2000( CISPR-22 ...

  • Acroprint Data Collection Terminal DC7000 - page 5

    5 Table of Contents 1. Introd uction ................... .................................... ............... ............ 6 Basic Hardware an d Vari ations ...................... ............................................6 General Specif ications ................................................................................6 2. Se tup ........ ...

  • Acroprint Data Collection Terminal DC7000 - page 6

    6 1. Introduction Basic h ardware and vari ati ons The elec tronic hard ware is a n ew, versat ile platform designed for use with va rious applications. This manual describes, in deta il, the e lectronic hard ware aspects of the terminal you have purchased. The details concerning terminal firmware and host software are addressed in the m anu al, wh ...

  • Acroprint Data Collection Terminal DC7000 - page 7

    7 F. Display: Backlit, Blue Ba ckgrou nd, 2 lines with 20 charac ters on each line. G. Keypad: Full travel keys with elasto meric cont act pad, 4 rows x 4 columns. H. Seri al Port: RS- 232 using 6 positi on (4 contact) RJ-11 mo dul ar connection. I. Serial Por t: RS-485 ( Local Area Networ k) usi ng RJ-11 mod ular connec tion. J. Parallel por t: 25 ...

  • Acroprint Data Collection Terminal DC7000 - page 8

    8 2. Setup Operating Environment The terminal can be inst alled in any normal office or controlled factory environment. However, do not use the terminal under the following conditions: • extremely high or low temperature [operating temperature range: 0° to 50° C (32° to 122° F)] [storage temperature range: - 20° to 60° C (-4° to 140° F)] ...

  • Acroprint Data Collection Terminal DC7000 - page 9

    9 Mounting Unscrew the access door. With the d oor off, the main unit can slide upward and be removed from the mount ing brack et. The bracket can be used for wall mounting, or it can be reversed to tilt the unit on a desktop. Power up This product is intended to be supp lied by a Listed Direct Plug-in Power Unit marked “Class 2” or “LPS” R ...

  • Acroprint Data Collection Terminal DC7000 - page 10

    10 3. Operator Interface Keypads The standard terminal keypad has 16 keys for entering alphabetical and numeric data as illustrated below. S tandard Alpha-Numeric Keypad MEN U MENU O p tional Numeric Ke yp ad ...

  • Acroprint Data Collection Terminal DC7000 - page 11

    11 Card Readers The DC7000 is availa ble with (3) types of ca rd readers. a) Magnetic stripe card reader . The magnetic stripe on the card should be on the right side as shown in the illustration. b) Internal barcode reader. Infrared or visible barcode readers are available. The card is sw iped thro ugh in the same fashion, but the barcode should b ...

  • Acroprint Data Collection Terminal DC7000 - page 12

    12 c) Proximity Readers Two Proximity Readers are available on the DC7000. The first Proximity Reader uses 125kHz, Read Only, ISO Proximity C ard, 64 Bit Encoding (Manchester). Serial Output Data String contains a 9 Bit Header, 40 Bits of Data, 14 Pa rity Bits and 1 Stop Bit. The second reader is a HID Read er that uses HID Badges: 125kHz, Read Onl ...

  • Acroprint Data Collection Terminal DC7000 - page 13

    13 Wireless WiFi Connection The Wireless Ethe rnet connection is established via Wireless 802.11b. RS-232 Serial port The RS-232 serial port is located on the lower left corner of the terminal. It is a six posi tion 4-pin female port, wh ich wi ll accept a male RJ-11 modular connector. The DC7000 Terminal can use RS -232 serial communication to con ...

  • Acroprint Data Collection Terminal DC7000 - page 14

    14 See Page 24 for USB to RS-232 Adaptor. (Use DB-25 RS -232 Host Ca ble Ass y . See pp. 24-25) Cabling to Host Computer with DB-25 Port NOTE: S chemati c c onnect ions are shown fr om END V IEW (a s viewed from the out side of t he connector s). Schematic Schematic (Use DB-25 R S-232 Host C able Ass y . See pp. 24-25) Cabling to Host Computer with ...

  • Acroprint Data Collection Terminal DC7000 - page 15

    15 Local Area Network: RS-485 Serial Port The RS-485 serial port is located on the lower left corner of the terminal. It is a six position 6-pin fe male port with the outer 2 pins to Ground. It will accept a male RJ-11 modular connector. The terminal can use RS-485 2-wire se rial communication, allowing up to 32 terminals to be connected to one hos ...

  • Acroprint Data Collection Terminal DC7000 - page 16

    16 RS-485 Serial Cables Junction Box “Daisy Chai n” Wiring Diagram RS485 Wiring Diagram The RS485 Serial port i s locat ed on t he left corner of the te rminal. RS485 i s imprinted on the terminal casing. A A RS485 communication all ows up to 32 termina l s to be conn ected t o one seri al por t. An RS232 po rt on t he host PC is used with an R ...

  • Acroprint Data Collection Terminal DC7000 - page 17

    17 Modem Port The port depicted may have either an RS- 485, a Modem, or an Ethernet Communication Device. Terminals, which are equipped with a Modem port, will not have an Ethernet or RS-485 port. The Modem Port is a 6 position 4-pin female port, which will accept a male RJ-11 modular connector. The internal modem (modulator/dem odulator) converts ...

  • Acroprint Data Collection Terminal DC7000 - page 18

    18 Modem Cables Caution – To reduce the risk of fire, use only 26 AWG or larger telecommun ication line cord. The cabling for modem operation is t ypically very simple. The modular connection uses the two inner wires of the RJ- 11 jack for “tip” and “ring.” Connect one end of the cable to the terminal and plug the other end into your RJ-1 ...

  • Acroprint Data Collection Terminal DC7000 - page 19

    19 Wand Port The Wand port is located on the left si de of the terminal. I t is a 6-pin DIN port that accepts a ci rcular DIN connector. The Wand, when connected, uses only 3 of the 6 pins available on the DIN connection. If a Ba rcode Gun (non-contact reader) is used, the center pin supplies add itional power. The termin al uses 2 of the remaining ...

  • Acroprint Data Collection Terminal DC7000 - page 20

    20 Wand and Y-Cable Disconnect power to the terminal before connecting the Barcode W a nd. The wand is capable of readi ng bar code stripes by passing it directly ove r the label. Check th e software manual to i dentify the codes your terminal will read. The Y -cable shown below allows for connection of both a wand and other external devices. The s ...

  • Acroprint Data Collection Terminal DC7000 - page 21

    21 Parallel Port The parallel port is located on the ba ck right of the DC7000 Terminal. It is a 25 pin female port, which will ac cept a 25-pin male connector . This type of parallel port is typically used on IBM ® PC or IBM-PC compatible computers. The DC7000 te rminal provides strain relief if the connector is locked in by the se curing screws. ...

  • Acroprint Data Collection Terminal DC7000 - page 22

    22 Parallel Cable The parallel port is used for additi onal digital I/O or for printing. A standard parallel p rint cable is used with a simple ASCII parallel printer. Shown below is a parallel inte rfa ce cable. Since this is the same cable that is used to connect an IBM- PC or compatible to a printer, it will likely be availabl e from most co mpu ...

  • Acroprint Data Collection Terminal DC7000 - page 23

    23 5. CompanionPr oducts Read er s Description / Illustration P a r t N u m b e r Barcode Wa nd 74-0106-002 and Hold er Power Supplies Descripti on/Illustrati on Part Number 120VAC t o 9VAC, 1A 56-0113-000 Power Supply 120/240 VAC to 12VAC, 3A 56-0128-000 Power Supply (Requi red f or Term inal s with Fi ngerpr int Reader, Modem or Wireless Co mmuni ...

  • Acroprint Data Collection Terminal DC7000 - page 24

    24 External Rela y Box, External Buzzer External Relay Box 120 V 01-0121-000 External Buzzer 01-0122-000 ...

  • Acroprint Data Collection Terminal DC7000 - page 25

    25 Cables Descripti on/Illustrati on Part Number “Standard” Modula r Cable length - 7 feet 72-0146-000 - 5 0 f eet 72-0146-004 Y-Cable (s plitter) 72-0159-000 DB-25 RS-232 Host Cable Assembl y Includes DB-2 5 Female (RS- 232/host) to RJ-11 Female adaptor and “Standard” Modular Cable. lengt h - 7 feet 25- 0116-000 - 5 0 f eet 25-0116-007 DB- ...

  • Acroprint Data Collection Terminal DC7000 - page 26

    26 Cables, Converter, Badge Racks Descr ipti on / Il lustrat ion Part Number Modem Adapto r Cable Assembl y Includes DB-25 Male (modem) to RJ-11 male adaptor and “Sta ndar d” Modular Cable. length - 7 feet 25-0123-000 Teflo n Cable (avai lab le by the f oot) 55-0124-000 Juncti on Box 63-0169-000 RS-232 to RS-485 Converter Assembly Includes RS-2 ...

  • Acroprint Data Collection Terminal DC7000 - page 27

    27 6. Appendix Units with Acroprint Data Co llecti on Firmware Acroprint Data Collection Terminal Setup Instructions Configuring procedure for en tering the DA TE & TIME: Swipe the C o nfiguration Badge 00000 0 000 (This badge is provided with e ach terminal) Select opti on 1 for DA TE <Press ENTER> Sele ct the Day , Month, Y ear DDMMYY Y ...

  • Acroprint Data Collection Terminal DC7000 - page 28

    28 (For RS485 terminals only) Select opti on 1 for RS485 <pre ss ENTER> Select the baud rate 0 for 1200, 1 for 2400, 2 for 48 00, 3 for 9600 and 4 for 19,200 baud. <pre ss ENTER> (For Ethernet term inals only) Select opti on 2 for Etherne t <press ENTER> Select the baud rate option 3 for 9600 baud < press EN TER> (Leave this ...

  • Acroprint Data Collection Terminal DC7000 - page 29

    29 Configuring procedure fo r selecting the READERS: Swipe the C o nfiguration Badge 00000 0 000 (This badge is provided w ith each terminal.) Select opti on 3 to ACTIV A TE READERS <press ENTER >. (Select any combination 1234 to activat e the r eaders. 1 for Internal Barcode, 2 for External Ba rcode, 3 for Interna l Magne tic S tripe and 4 f ...

  • Acroprint Data Collection Terminal DC7000 - page 30

    30 Electrical Connections Parallel Port Connector on DC7000 Digital IO Mode Printer Mode 1 Digital I O #7 1 St robe 2 Dig ital IO #8 2 Printer D ata 0 3 Dig ital IO #9 3 Printer D ata 1 4 Dig ital IO #1 0 4 Printe r Data 2 5 Dig ital IO #1 1 5 Printe r Data 3 6 Dig ital IO #1 2 6 Printe r Data 4 7 Dig ital IO #1 3 7 Printe r Data 5 8 Dig ital IO #1 ...

  • Acroprint Data Collection Terminal DC7000 - page 31

    31 DC7000 Wand Connector Socket 1 +5 Volts 2 Signal Control Logi c Line (Dig ital IO #0 - Output On ly) 3 Barcode Wand Receive Date 4 Ground 5 Access Logic Line (Dig ital IO #1 - Output On ly) 6 +12 Volts Unregu lated (Max Curr ent Draw 220mA wit h 3A Transformer Only) DC7000 RS232 Connector 1 Not Used 2 CTS 3 Transmit Data (from DC7000) 4 Receive ...

  • Acroprint Data Collection Terminal DC7000 - page 32

    32 DC7000 RS485 / Modem C onnector Modem R S 4 8 5 1 Not Used 1 GND 2 N/A 2 N/A 3 TIP 3 Data (-) 4 RING 4 Data (+) 5 N/A 5 N/A 6 Not Used 6 GND DC7000 Ethernet Connector 1 Data (TX +) 2 Data (TX -) 3 Data (RX +) 4 Ground (-) 5 Ground (-) 6 Data (RX -) 7 Power (+) 8 Power (+) 1 2 3 4 5 6 7 8 ...

  • Acroprint Data Collection Terminal DC7000 - page 33

    33 Specific ations IO Points 0–1 Output High: 4.0 milliamps o ut of MA X, V o ut = 4.2 Volts MIN Low: 4.0 milliamps in MAX , V out = 0.4 Volts MAX Input: Not Applicable IO Points 2–15 Output High: 1.6 milliamps o ut of MA X, V o ut = 2.4 Volts MIN Low: 2.0 milliamps in MAX , V out = 0.4 Volts MAX Input: Input Voltage Range: 0–5 Volts High: 2. ...

  • Acroprint Data Collection Terminal DC7000 - page 34

    34 This page intentionally left blank ...

  • Acroprint Data Collection Terminal DC7000 - page 35

    35 This page intentionally left blank ...

  • Acroprint Data Collection Terminal DC7000 - page 36

    36 5640 Departure Drive Raleigh, NC 27616 919.872.5800 www.acroprint.com P/N 06-0333 -000 Rev. B ...

Производитель Acroprint Категория Switch

Документы, которые мы получаем от производителя устройства Acroprint Data Collection Terminal DC7000 мы можем разделить на несколько групп. Это в частности:
- технические чертежи Acroprint
- инструкции обслуживания Data Collection Terminal DC7000
- паспорта изделия Acroprint
- информационные брошюры
- энергетические этикетки Acroprint Data Collection Terminal DC7000
Все из них важны, однако самую важную информацию с точки зрения пользователя мы найдем в инструкции обслуживания Acroprint Data Collection Terminal DC7000.

Группа документов, определяемая как инструкции обслуживания, делится также на более подробные типы, такие как: Инструкции монтажа Acroprint Data Collection Terminal DC7000, инструкции обслуживания, короткие инструкции или инструкции пользователя Acroprint Data Collection Terminal DC7000. В зависимости от потребностей, Вам необходимо поискать требуемый документ. На нашем сайте Вы можете просмотреть самую популярную инструкцию использования изделия Acroprint Data Collection Terminal DC7000.

Похожие инструкции обслуживания

Полная инструкция обслуживания устройства Acroprint Data Collection Terminal DC7000, как должна выглядеть?
Инструкция обслуживания, определяемая также как пособие пользователя, или просто "руководство" - это технический документ, цель которого заключается в использовании Acroprint Data Collection Terminal DC7000 пользователями. Инструкции пишет, как правило технический писатель, языком, доступным для всех пользователей Acroprint Data Collection Terminal DC7000.

Полная инструкция обслуживания Acroprint, должна заключать несколько основных элементов. Часть из них менее важная, как например: обложка / титульный лист или авторские страницы. Однако остальная часть, должна дать нам важную с точки зрения пользователя информацию.

1. Вступление и рекомендации, как пользоваться инструкцией Acroprint Data Collection Terminal DC7000 - В начале каждой инструкции, необходимо найти указания, как пользоваться данным пособием. Здесь должна находится информация, касающаяся местонахождения содержания Acroprint Data Collection Terminal DC7000, FAQ и самых распространенных проблем - то есть мест, которые чаще всего ищут пользователи в каждой инструкции обслуживания
2. Содержание - индекс всех советов, касающихся Acroprint Data Collection Terminal DC7000, которое найдем в данном документе
3. Советы по использованию основных функций устройства Acroprint Data Collection Terminal DC7000 - которые должны облегчить нам первые шаги во время использования Acroprint Data Collection Terminal DC7000
4. Troubleshooting - систематизированный ряд действия, который поможет нам диагностировать а в дальнейшем очередность решения важнейших проблем Acroprint Data Collection Terminal DC7000
5. FAQ - чаще всего задаваемые вопросы
6. Контактные данные Информация о том, где искать контактные данные производителя / сервисного центра Acroprint Data Collection Terminal DC7000 в данной стране, если самостоятельно не получится решить проблему.

У вас вопрос, касающийся Acroprint Data Collection Terminal DC7000?

Воспользуйтесь формуляром, находящимся ниже

Если с помощью найденной инструкции Вы не решили свою проблему с Acroprint Data Collection Terminal DC7000, задайте вопрос, заполнив следующий формуляр. Если у какого то из пользователей была похожая проблема с Acroprint Data Collection Terminal DC7000 со всей вероятностью он захочет поделиться методом ее решения.

Перепишите текст с картинки

Комментарии (0)