    1 OWNER ’ S OPERA TION AND INST ALLA TION MANUAL COMP ACT L.P .& NA TURAL GAS VENT -FREE STOVE W ARNING: If the infor mation in this manual is not follo wed exactly,a fire or explosion may result causing prop erty damage, personal injury, or loss of life. W ARNING: This is an unvented gas-fired heater. It uses air (oxygen) from the room in wh ...

  • Procom QL300RYLA-W - page 2

    2 Safety information warnings--------------------3 Air for conbustion & V entilation----------------5 Installation-------------------------------------------7 Operation Heater---------------------------- -----1 1 Cleaning and Maintenance-------------------- 13 Specification----------------------------------------15 T roubleshooting------------- ...

  • Procom QL300RYLA-W - page 3

    3 IMPORT ANT : Read this owner’s manual carefully and completely before trying to assemble, operate, or service this heater. Improper use of this heater can cause serious injury or death from burns, fire, explosion, electrical shock, and carbon monoxide poisoning. SAFETY INFORMA TION W ARNINGS DANGER: Carbon monoxide poisoning may lead to death! ...

  • Procom QL300RYLA-W - page 4

    4 SAFETY INFORMA TION Continued 15. Turn off and unplug heater and let cool before servicing. Only a qualified service person should service and repair heater. 16. Operating heater above elevations of 4,500 feet could cause pilot outage. 17. Do not operate heater if any log is broken. Do not operate heater if a log is chipped (dime-sized or larger) ...

  • Procom QL300RYLA-W - page 5

    5 AIR FOR COMBUSTION AND VENTILA TION W ARNING: This heater shall not be installed in a confined space or unusually tight con- struction unless provisions are provided for adequate combus- tion and ventilation air. Read the following instructions to insure proper fresh air for this and other fuel-burning appliances in your PROVIDING ADEQUA TE VENTI ...

  • Procom QL300RYLA-W - page 6

    6 W ARNING: Rework worksheet, adding the space of the adjoining unconfined space. The combined spaces must have enough fresh air to supply all appliances in both spaces. If the actual Btu/Hr used is less than the maximum Btu/Hr the space can support, the space is an unconfined space. Y ou will need no additional fresh air ventilation. 3. Add the Bt ...

  • Procom QL300RYLA-W - page 7

    7 W A TER V APOR:A BY -PRODUCT OF UNVENTED ROOM HEA TERS Water vapor is by-product of gas combustion.an unvented room heater prodrces approximately one (1) ounce (30ml) of water for every 1, 000BTU’s (.3kw’s) of gas input per hour. Unvented room heaters are recom- mended as supplemtal heat (a room) rather that a primary heat source(an entire ho ...

  • Procom QL300RYLA-W - page 8

    8 CLEARANCES TO COMBUSTIBLES (V ent-Free Operation Only) Carefully follow the instructions below. This stove is a freestanding unit designed to set directly on the floor. IMPORT ANT : Y ou must maintain minimum wall and ceiling clearances during installation. The minimum clearances are shown in Figure 4. Measure from outermost point of stove top. M ...

  • Procom QL300RYLA-W - page 9

    9 W ARNING: Never connect heater to private (non-utility) gas wells. This gas is commonly known as wellhead gas. CAUTION: Use only new, black iron or steel pipe. Internally-tinned copper tubing may be used in certain areas. Check your local codes. Use pipe of 1/2 " diameter or greater to allow proper volume gas to heater. If pipe is too small, ...

  • Procom QL300RYLA-W - page 10

    10 2. Open gas supply tank valve. 3. Make sure control knob of heater is in the OFF position. 4. Check all joints from equipment shutoff valve to control valve (LP GAS see Figure 9.1 NA TURAL GAS see Figure 9.2). Apply mixture of liquid soap and water to gas joints. Bubbles forming show a leak. 5. Correct all leaks at once. 6. Light heater (see Ope ...

  • Procom QL300RYLA-W - page 11

    11 OPERA TING HEA TER FOR YOUR SAFETY READ BEFORE LIGHTING A. This appliance has a pilot which must be lighted by control system, When lighting the pilot, follow these instructions exactly. B. BEFORE LIGHTING smell all around the appliance area for gas. Be sure to smell next to the floor because some gas is heavier than air and will settle on the f ...

  • Procom QL300RYLA-W - page 12

    12 b. manual select of main burner: Press BURNER button, the flame is on “MAN” select. At this selection, the main burner will keep working no matter what the temperature is set at. If there is a need to shut off the main burner, just press the “BURNER” button to make the burner on the “OFF” select. c.shut off the main burner: the main ...

  • Procom QL300RYLA-W - page 13

    13 INSPECTING BURNERS Check pilot flame pattern and burner flame patterns often. PILOT FLAME P A TTERN Figure 18 shows a correct pilot flame pattern. Figure 19 shows an incorrect pilot flame pattern. The incorrect pilot flame is not touching the thermocouple.This will cause the thermocouple to cool. When the thermocouple cools, the heater will shut ...

  • Procom QL300RYLA-W - page 14

    14 Air Passageways  Use a vacuum cleaner or pressurized air to clean. Exterior  Use a soft cloth dampened with a mild soap and water mixture. Wipe the cabinet to remove dust. LOGS  If you remove logs for cleaning, refer to Installing Logs to properly replace logs.  Replace logs if broken or chipped (dimesized or larger). REPLACEMENT P A ...

  • Procom QL300RYLA-W - page 15

    15 SPECIFICA TIONS QL300R YLA QN300R YLA QL300R YLA-W QN300R YLA-W Btu(V ariable) Gas T ype LP Gas Natural Gas Ignition Automatic Automatic Manifold Pressure 8"W.C. 3"W.C. Inlet Gas Pressure (In. of water)* Maximum 14" 10.5" Minimum 1 1" 5" Dimensions, Inches (H × W × D) Heater 25 4/5" × 32 1/4” × 13" 2 ...

  • Procom QL300RYLA-W - page 16

    16 TROUBLESHOOTING REMEDY W ARNING :Make sure that power is turn off before proceeding.... W ARNING: T urn off and let cool before servicing. Only a qualified service person should service and repair fireplace. CAUTION: Never use a wire, needle, or similar object to clean ODS/pilot. This can damage ODS/ pilot unit. When pressing the button of ignit ...

  • Procom QL300RYLA-W - page 17

    17 TROUBLESHOOTING Continued OBSERVED PROBLEM POSSIBLE CAUSE REMEDY Delayed ignition burner 1. Manifold pressure is too low 2. Burner orifice clogged 1 . Contact local gas company 2. Clean burner (see Cleaning and Maintenance, page 13) Burner backfiring during combustion 1. Damaged burner 2. Gas regulator defective 1. Clean burner orifice ( see Cle ...

  • Procom QL300RYLA-W - page 18

    18 ILLUSTRA TED P ARTS BREAKDOWN QL300R YLA QN300R YLA QL300R YLA-W QN300R YLA-W ...

  • Procom QL300RYLA-W - page 19

    19 P ARTS LIST QL300R YLA QN300R YLA QL300R YLA-W QN300R YLA-W ...

  • Procom QL300RYLA-W - page 20

    20 ILLUSTRA TED P ARTS BREAKDOWN QL300R YLA QN300R YLA QL300R YLA-W QN300R YLA-W ...

  • Procom QL300RYLA-W - page 21

    21 P ARTS LIST QL300R YLA QN300R YLA QL300R YLA-W QN300R YLA-W ...

  • Procom QL300RYLA-W - page 22

    22 PLACING INSTRUCTION Follow the procedures below and the instruction drawings to put log sets in place to the gas stove(indoor vent-free). NOTICE: THE CORRECT POSITION OF THE LOGS SHOULD NOT IM- PINGE ON THE FLAME. THE LOG’S P ACKAGE IS LOCA TED INSIDE THE UNIT THEN REMOVE SCREEN AND T AKE OUT THE LOG’S P ACKAGE FIRST REMOVE TWO TOP SCREWS FR ...

  • Procom QL300RYLA-W - page 23

    23 Q SERIES LOG SET INST ALLA TION INSTRUCTIONS ...

  • Procom QL300RYLA-W - page 24

    24 FIG(3) FIG(4) STEP 2: Install the log 2 on the right rear angle iron. see FIG(3) STEP 3: Install the log 3 on the front angle iron. See FIG(4). 1 INST ALLA TION INSTRUCTIONS FOR LOG SETS 1. All logs FIG(1) FIG(2) STEP 1: Install the log 1 on the left rear angle iron. see FIG(2) ...

  • Procom QL300RYLA-W - page 25

    25 2 2 FIG(5) STEP 4: Insert the pinhole on the upper part of log 4 into the pin on the left side of log 1. Place the lower part of log 4 on the flat roof at the left side of log 3 See FIG(5). STEP 4: Insert the pinhole on the upper part of log 5 into the pin on the log 2. Place the lower part of log 5 on the flat roof at the left side of log 3 . S ...

Производитель Procom Категория Stove

Документы, которые мы получаем от производителя устройства Procom QL300RYLA-W мы можем разделить на несколько групп. Это в частности:
- технические чертежи Procom
- инструкции обслуживания QL300RYLA-W
- паспорта изделия Procom
- информационные брошюры
- энергетические этикетки Procom QL300RYLA-W
Все из них важны, однако самую важную информацию с точки зрения пользователя мы найдем в инструкции обслуживания Procom QL300RYLA-W.

Группа документов, определяемая как инструкции обслуживания, делится также на более подробные типы, такие как: Инструкции монтажа Procom QL300RYLA-W, инструкции обслуживания, короткие инструкции или инструкции пользователя Procom QL300RYLA-W. В зависимости от потребностей, Вам необходимо поискать требуемый документ. На нашем сайте Вы можете просмотреть самую популярную инструкцию использования изделия Procom QL300RYLA-W.

Похожие инструкции обслуживания

Полная инструкция обслуживания устройства Procom QL300RYLA-W, как должна выглядеть?
Инструкция обслуживания, определяемая также как пособие пользователя, или просто "руководство" - это технический документ, цель которого заключается в использовании Procom QL300RYLA-W пользователями. Инструкции пишет, как правило технический писатель, языком, доступным для всех пользователей Procom QL300RYLA-W.

Полная инструкция обслуживания Procom, должна заключать несколько основных элементов. Часть из них менее важная, как например: обложка / титульный лист или авторские страницы. Однако остальная часть, должна дать нам важную с точки зрения пользователя информацию.

1. Вступление и рекомендации, как пользоваться инструкцией Procom QL300RYLA-W - В начале каждой инструкции, необходимо найти указания, как пользоваться данным пособием. Здесь должна находится информация, касающаяся местонахождения содержания Procom QL300RYLA-W, FAQ и самых распространенных проблем - то есть мест, которые чаще всего ищут пользователи в каждой инструкции обслуживания
2. Содержание - индекс всех советов, касающихся Procom QL300RYLA-W, которое найдем в данном документе
3. Советы по использованию основных функций устройства Procom QL300RYLA-W - которые должны облегчить нам первые шаги во время использования Procom QL300RYLA-W
4. Troubleshooting - систематизированный ряд действия, который поможет нам диагностировать а в дальнейшем очередность решения важнейших проблем Procom QL300RYLA-W
5. FAQ - чаще всего задаваемые вопросы
6. Контактные данные Информация о том, где искать контактные данные производителя / сервисного центра Procom QL300RYLA-W в данной стране, если самостоятельно не получится решить проблему.

У вас вопрос, касающийся Procom QL300RYLA-W?

Воспользуйтесь формуляром, находящимся ниже

Если с помощью найденной инструкции Вы не решили свою проблему с Procom QL300RYLA-W, задайте вопрос, заполнив следующий формуляр. Если у какого то из пользователей была похожая проблема с Procom QL300RYLA-W со всей вероятностью он захочет поделиться методом ее решения.

Перепишите текст с картинки

Комментарии (0)