Инструкция обслуживания Generac Power Systems 004987-2, 005396-0

36 страниц 2.67 mb
Скачать

Перейти на страницу of 36

Summary
  • Generac Power Systems 004987-2, 005396-0 - page 1

    • Safety • Assembly • Operation • Maintenance • Troubleshooting • Electrical Data • Par ts • W arranty FOR THE NEAREST A UTHORIZED SER VICE CENTER 1-800-333-1322 Owner ’s Man ual MODELS: 004987-2 (15,000 W att) 005396-0 (17,500 W att) www .centuriongenerators.com COMMERCIAL • INDUSTRIAL • RESIDENTIAL ...

  • Generac Power Systems 004987-2, 005396-0 - page 2

    T able of Contents Introduction .................................................................. 1 Read This Manual Thor oughly ..................................... 1 Safety Rules .................................................................. 2 Standards Index ........................................................................... 3 Sect ...

  • Generac Power Systems 004987-2, 005396-0 - page 3

    INTRODUCTION Thank you f or purchasing this model b y Generac P o wer Systems, Inc. ® This model is a compact, high perf ormance, air-cooled, engine driven generator designed to supply electrical power to oper ate electrical loads where no utility power is av ailab le or in place of utility due to a power outage . READ THIS MANU AL THOR OUGHL Y If ...

  • Generac Power Systems 004987-2, 005396-0 - page 4

    2 Nev er start or stop the unit with electr ical loads connected to receptacles AND with connected devices turned ON. Star t the engine and let it stabilize bef ore connecting electrical loads. Disconnect all electr ical loads before shutting do wn the generator . Do not inser t objects through unit's cooling slots. Never operate generator: In ...

  • Generac Power Systems 004987-2, 005396-0 - page 5

     ELECTRICAL HAZARDS  All generators cov ered b y this manual produce dangerous electrical voltages and can cause f atal electrical shock. Utility power deliv ers extremely high and dangerous v oltages as does the gener ator when it is in operation. Av oid contact with bare wires, terminals, connections, etc., while the unit is running. Ensure ...

  • Generac Power Systems 004987-2, 005396-0 - page 6

    4 1.1 UNP A CKING Set the palleted car ton on a rigid flat surface. Remov e staples along bottom of car ton that fasten carton to pallet. Open car ton from top. Remov e all packaging material. Remov e separate accessory box. Lift car ton off the generator . Remov e generator from shipping pallet b y removing bolts through the shipping brack ets (Fi ...

  • Generac Power Systems 004987-2, 005396-0 - page 7

    5 5 1.2.3 B A TTER Y CONNECTION The battery shipped with the generator has been provided fully charged. Caution m ust be taken when connecting the battery . NO TE: A battery may lose some of it’ s charge when not in use for prolonged periods of time. Cut the tie wrap cable holding the RED and BLA CK battery cables to the stator . Connect the RED ...

  • Generac Power Systems 004987-2, 005396-0 - page 8

    6 6 Section 2 – Operation 2.1 KNO W THE GENERA T OR Read the Owner’ s Man ual and Safety Rules before operating this generator . Compare the generator to Figures 4 through 6 to become f amiliarized with the locations of various controls and adjustments. Sav e this manual f or future ref erence. Figure 4 - Control P anel 1. 12 V olt DC, 10 Amp R ...

  • Generac Power Systems 004987-2, 005396-0 - page 9

    7 2.2 CORD SETS AND CONNECTION PLUGS 2.2.1 120 V A C, 20 AMP , DUPLEX RECEPT A CLE This is a 120 V olt outlet protected against overload by a 20 Amp push-to-reset circuit breaker (Figure 7). Use each socket to po wer 120 V olt AC , single phase, 60 Hz electrical loads requiring up to a combined 2400 watts (2.4 kW) or 20 Amps of current. Use only hi ...

  • Generac Power Systems 004987-2, 005396-0 - page 10

    8 Use this receptacle to operate 120 V olt AC , 60 Hz, single phase loads requiring up to 3600 watts (3.6 kW) of power at 30 Amps . The outlet is protected by a 30 Amp push-to-reset circuit break er . 2.2.4 120/240 V A C, 30 AMP RECEPT A CLE Use a NEMA L14-30 plug with this receptacle. Connect a suitable 4- wire grounded cord set to the plug and to ...

  • Generac Power Systems 004987-2, 005396-0 - page 11

    9 Proper gr ounding of the generator will help prevent electrical shock in the e v ent of a ground f ault condition in the generator or in connected electrical devices. Proper grounding also helps dissipate static electricity , which often builds up in ungrounded de vices . 2.3.2 CONNECTING ELECTRICAL LO ADS DO NO T connect 240 V olt loads to 120 V ...

  • Generac Power Systems 004987-2, 005396-0 - page 12

    10 10 Section 2 – Operation 2.6 BEFORE ST ARTING THE GENERA T OR Prior to operating the generator , engine oil and gasoline will need to be added, as follo ws: 2.6.1 ADDING ENGINE OIL NO TE: When adding oil to the engine crankcase in the future, use only high quality detergent oil rated with API service classification SG, SH or SL. Use no special ...

  • Generac Power Systems 004987-2, 005396-0 - page 13

    11 2.7 T O ST AR T THE ENGINE  Never start or stop engine with electrical devices plugged into the receptacles AND de vices turned on. Unplug all electrical loads from the unit's receptacles before star ting the engine. Make sure the unit is in a le v el position. Open the fuel shut-off valv e (Figure 15). Figure 15 - Fuel Shut-off V alve L ...

  • Generac Power Systems 004987-2, 005396-0 - page 14

    12 2.9 A UT OMA TIC IDLE CONTROL This feature is designed to g reatly improv e fuel economy . When this switch is turned “ On , ” the engine will only run at its normal fast gov erned engine speed when electr ical load is connected. When the load is remov ed, the engine will run at a reduced speed of 2100 RPM. With the switch “ Off , ” the ...

  • Generac Power Systems 004987-2, 005396-0 - page 15

    13 13 Section 3 — Maintenance 3.1 MAINTENANCE SCHEDULE Follo w the calendar intervals. More frequent ser vice is required when operating in adv erse conditions noted below . Maintenance Daily Every Season Check Oil Le v el  Ser vice Air Pre-Cleaner  ** Change Oil and Oil Filter‡  * Clean Spark Arrestor Screen  Check V alve Clearance ...

  • Generac Power Systems 004987-2, 005396-0 - page 16

    14 14 Section 3 — Maintenance NO TE: DO NO T use a garden hose to c lean generator . W ater can enter the engine fuel system and cause problems. In addition, if water enters the generator through cooling air slots, some water will be retained in voids and cre vices of the rotor and stator winding insulation. W ater and dirt buildup on the generat ...

  • Generac Power Systems 004987-2, 005396-0 - page 17

    15 15 T o clean or replace foam pre-c leaner: Remov e air cleaner cov er , then f oam pre-filter . W ash pre-cleaner in soap y water . Squeeze pre-filter dry in clean cloth (DO NO T TWIST). Clean air cleaner cov er bef ore re-installing it. T o clean or replace paper air filter: Remov e air cleaner cov er; then remo v e f oam pre-filter (ser vice i ...

  • Generac Power Systems 004987-2, 005396-0 - page 18

    16 When valv e clearance is correct, hold the piv ot ball stud in place with the allen wrench and tighten the rock er arm jam nut. Tighten the jam nut to 174 in/lbs. torque. After tightening the jam n ut, recheck v alv e clearance to make sure it did not change . Install new v alv e cov er gasket. Re-attach the valv e cov er . NO TE: Start all four ...

  • Generac Power Systems 004987-2, 005396-0 - page 19

    17 17 Section 4 — T r oubleshooting 4.1 TROUBLESHOO TING GUIDE PROBLEM CA USE CORRECTION Engine is running, but no A C output is av ailable. 1. Circuit break er is open. 2. P oor connection or defectiv e cord set. 3. Connected de vice is bad. 4. F ault in generator . 1. Reset circuit break er . 2. Chec k and repair . 3. Connect another de vice th ...

  • Generac Power Systems 004987-2, 005396-0 - page 20

    18 Section 5 — Notes ...

  • Generac Power Systems 004987-2, 005396-0 - page 21

    19 Section 6 — Electrical Data Schematic – Drawing No. 0G2894-A ...

  • Generac Power Systems 004987-2, 005396-0 - page 22

    20 20 Section 6 — Electrical Data Wiring Diagram – Drawing No. 0G2892-A ...

  • Generac Power Systems 004987-2, 005396-0 - page 23

    21 21 Section 6 — Electrical Data Wiring Diagram – Drawing No. 0G2892-A ...

  • Generac Power Systems 004987-2, 005396-0 - page 24

    22 Section 7 — Exploded Views and P arts Lists GT -990 Engine – Drawing No. 0G2963-G (Part 1) ...

  • Generac Power Systems 004987-2, 005396-0 - page 25

    23 Section 7 — Exploded Views and P arts Lists GT -990 Engine – Drawing No. 0G2963-G (Part 1) ITEM P ART NO. QTY . DESCRIPTION 1 0C5729 1 ASSY , CRANKCASE WITH SLEEVE 2 0E9843A 1 SEAL, 38 I.D . CRANKSHAFT GREEN 3 0G0919 7 SCREW , HHFCS M6-1.0 X 12 G8.8 4 0C5372 1 ASSEMBL Y , BREA THER 5 0C3005 1 GASKET , BREA THER CO VER 6 0E3372B 1 SEP ARA T O ...

  • Generac Power Systems 004987-2, 005396-0 - page 26

    24 Section 7 — Exploded Views and P arts Lists GT -990 Engine – Drawing No. 0G2963-G (Part 2) ...

  • Generac Power Systems 004987-2, 005396-0 - page 27

    25 Section 7 — Exploded Views and P arts Lists GT -990 Engine – Drawing No. 0G2963-F (Part 2) ITEM P ART NO. QTY . DESCRIPTION 66 0D6592 1 WINGNUT , AIRBO X 67 0D4511 1 PRECLEANER, AIR 68 0D9723 1 ELEMENT , AIR CLEANER 69 0E5302 1 STUD M6-1.0 X 73 70 0D4183 1 ADAPT OR, SPIT BA CK 71 0D6327 1 GASKET , SPITBACK 72 0D2774B 1 BASE, AIRBO X 73 0D512 ...

  • Generac Power Systems 004987-2, 005396-0 - page 28

    26 Section 7 — Exploded Views and P arts Lists Generator – Drawing No. 0G2964 ...

  • Generac Power Systems 004987-2, 005396-0 - page 29

    27 Section 7 — Exploded Views and P arts Lists Generator – Drawing No. 0G2964 ITEM P ART NO . QTY . DESCRIPTION 1 066849 2 SCREW HHTT M5-0.8 X 16 2 0G2921 1 ST A T OR 15KW 0G2923 ST A TOR 17.5KW 3 0G29220SR V 1 ASSEMBL Y , RO T OR WITH F AN 15KW 0G29240SR V ASSEMBL Y , ROT OR WITH F AN 17.5KW 4 0C6043B 1 CARRIER, REAR BEARING 5 0D2492 1 EXHA US ...

  • Generac Power Systems 004987-2, 005396-0 - page 30

    28 Section 7 — Exploded Views and P arts Lists Control P anel – Drawing No. 0G2965-B ...

  • Generac Power Systems 004987-2, 005396-0 - page 31

    29 Section 7 — Exploded Views and P arts Lists Control P anel – Drawing No. 0G2965-B ITEM P ART NO. QTY . DESCRIPTION 1 0G28880ST03 1 CONTROL P ANEL BOX (15 KW & 005396) 0G28900ST03 1 CONTROL P ANEL BO X (17.5 KW) 2 0D4409 1 ELECTRONIC GO VERNOR / IDLE CONTROLLER 3 0F9719 1 ASSY PCB VREG AIR COOLED 4 0F3100 1 RELA Y 3PDT 12VDC 5 0F3101 1 RE ...

  • Generac Power Systems 004987-2, 005396-0 - page 32

    30 Section 7 — Exploded Views and P arts Lists Frame, Handle & Wheel Kit – Drawing No. 0E0695-B ...

  • Generac Power Systems 004987-2, 005396-0 - page 33

    31 ITEM P ART NO . QTY . DESCRIPTION 1 057058 4 SCREW HHC M6-1.0 X 55 2 0D5315 4 R UBBER T ANK MOUNT 3 0D4570 1 CAP , FUEL WITH GA UGE & VENT 4 0D22850SR V 1 KIT , FUEL T ANK 5 045771 4 NUT HEX M8-1.25 6 022129 10 WASHER LOCK M8-5/16 7 022145 14 WASHER FLA T 5/16 8 0D4565 1 BRACKET BA TTERY 9 0D3545 2 BOL T ,BA TTERY J-BOL T 10 022287 2 SCREW H ...

  • Generac Power Systems 004987-2, 005396-0 - page 34

    32 CALIFORNIA EMISSION CONTROL W ARRANTY ST A TEMENT Y OUR W ARRANTY RIGHTS AND OBLIGA TIONS The Calif ornia Air Resources Board (CARB) and Generac P ow er Systems, Inc. (Generac) are pleased to e xplain the Emission Control System warranty on y our ne w engine. In California, new off-road Large Spark-Ignition (LSI) engines must be designed, b uilt ...

  • Generac Power Systems 004987-2, 005396-0 - page 35

    33 Section 8 – Warranty EMISSION CONTROL SYSTEM W ARRANTY Emission Control System W arr anty (ECS warranty) f or 2001 and later model y ear LSI engines: (a) Applicability: This warranty shall apply to 2001 and later model y ear engines. The ECS W arranty period shall begin on the d ate the new engine or equipment is purchased by/deliv ered to its ...

  • Generac Power Systems 004987-2, 005396-0 - page 36

    Section 8 – Warranty P ar t No . 0G2955 Re v . B GENERA C PO WER SYSTEMS “TWO YEAR” LIMITED W ARRANTY FOR CENTURION ® “15,000 AND 17,500 W A TT PORT ABLE GENERA T ORS” For a period of two y ears from the date of original sale, Generac P o wer Systems, Inc. (Generac) warrants its Centurion generator will be free from def ects in materials ...

Производитель Generac Power Systems Категория Portable Generator

Документы, которые мы получаем от производителя устройства Generac Power Systems 004987-2, 005396-0 мы можем разделить на несколько групп. Это в частности:
- технические чертежи Generac Power Systems
- инструкции обслуживания 004987-2, 005396-0
- паспорта изделия Generac Power Systems
- информационные брошюры
- энергетические этикетки Generac Power Systems 004987-2, 005396-0
Все из них важны, однако самую важную информацию с точки зрения пользователя мы найдем в инструкции обслуживания Generac Power Systems 004987-2, 005396-0.

Группа документов, определяемая как инструкции обслуживания, делится также на более подробные типы, такие как: Инструкции монтажа Generac Power Systems 004987-2, 005396-0, инструкции обслуживания, короткие инструкции или инструкции пользователя Generac Power Systems 004987-2, 005396-0. В зависимости от потребностей, Вам необходимо поискать требуемый документ. На нашем сайте Вы можете просмотреть самую популярную инструкцию использования изделия Generac Power Systems 004987-2, 005396-0.

Похожие инструкции обслуживания

Полная инструкция обслуживания устройства Generac Power Systems 004987-2, 005396-0, как должна выглядеть?
Инструкция обслуживания, определяемая также как пособие пользователя, или просто "руководство" - это технический документ, цель которого заключается в использовании Generac Power Systems 004987-2, 005396-0 пользователями. Инструкции пишет, как правило технический писатель, языком, доступным для всех пользователей Generac Power Systems 004987-2, 005396-0.

Полная инструкция обслуживания Generac Power Systems, должна заключать несколько основных элементов. Часть из них менее важная, как например: обложка / титульный лист или авторские страницы. Однако остальная часть, должна дать нам важную с точки зрения пользователя информацию.

1. Вступление и рекомендации, как пользоваться инструкцией Generac Power Systems 004987-2, 005396-0 - В начале каждой инструкции, необходимо найти указания, как пользоваться данным пособием. Здесь должна находится информация, касающаяся местонахождения содержания Generac Power Systems 004987-2, 005396-0, FAQ и самых распространенных проблем - то есть мест, которые чаще всего ищут пользователи в каждой инструкции обслуживания
2. Содержание - индекс всех советов, касающихся Generac Power Systems 004987-2, 005396-0, которое найдем в данном документе
3. Советы по использованию основных функций устройства Generac Power Systems 004987-2, 005396-0 - которые должны облегчить нам первые шаги во время использования Generac Power Systems 004987-2, 005396-0
4. Troubleshooting - систематизированный ряд действия, который поможет нам диагностировать а в дальнейшем очередность решения важнейших проблем Generac Power Systems 004987-2, 005396-0
5. FAQ - чаще всего задаваемые вопросы
6. Контактные данные Информация о том, где искать контактные данные производителя / сервисного центра Generac Power Systems 004987-2, 005396-0 в данной стране, если самостоятельно не получится решить проблему.

У вас вопрос, касающийся Generac Power Systems 004987-2, 005396-0?

Воспользуйтесь формуляром, находящимся ниже

Если с помощью найденной инструкции Вы не решили свою проблему с Generac Power Systems 004987-2, 005396-0, задайте вопрос, заполнив следующий формуляр. Если у какого то из пользователей была похожая проблема с Generac Power Systems 004987-2, 005396-0 со всей вероятностью он захочет поделиться методом ее решения.

Перепишите текст с картинки

Комментарии (0)