    FOR DISTRIBUTION USE ONLY - NOT TO BE USED AT POINT OF RETAIL SALE 360101-XT G-A-0108 TECHNICAL GUIDE ® DESCRIPTION These packaged cooling air conditi oners are designed for outdoor installation. Only ut i lity and duct connections are required at the point of installation. Field-installed electric he ater accessories are availabl e to provide ele ...

  • York AFFINITY 360101-XTG-A-0108 - page 2

    360101-XTG-A-0108 2 Johnson Controls Unitary Products TABLE OF CONTENTS DESCRIPTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 STANDARD FEATURES / BENEFITS . . . . . . . . . . . . . . . . . 1 FIELD-INSTALLED ACCESSORIES . . . . . . . . . . . . . . . . . . 3 TYPICAL APPLICATIONS . . . . . . . . . . . . . . . . . . . . . ...

  • York AFFINITY 360101-XTG-A-0108 - page 3

    360101-XTG-A-0108 Johnson Controls Unitary Products 3 STANDARD FEATURES/BENEFITS (CONT.) UTILITY CONNECTIONS MADE EASY - Electri c al utility knockouts are provided through the bottom as well as the side of the unit. Utility connections can be made quickly and with a minimum amount of field labor. A field supplie d and field installed electrical di ...

  • York AFFINITY 360101-XTG-A-0108 - page 4

    360101-XTG-A-0108 4 Johnson Controls Unitary Products operation. Independe nt blade desig n insures p roper control and less than 1% leak rate. Includes hood an d me sh bird screen filter integrated into the ho od, dry bulb senso r and relie f damper. Separate field a ccessories of single enthalpy and dual enthalpy are also available. SINGLE ENTHAL ...

  • York AFFINITY 360101-XTG-A-0108 - page 5

    360101-XTG-A-0108 Johnson Controls Unitary Products 5 SEER = Seasonal Energy Efficiency Ratio - the total coolin g output in BTU's during a normal annual usage period for cooling div ided by the total electric power input in watt-hours dur ing the same period. T ABLE 1: PHYSICAL DA T A MODELS DEB 018 024 030 036 042 048 060 EVAPORATOR BLOWER C ...

  • York AFFINITY 360101-XTG-A-0108 - page 6

    360101-XTG-A-0108 6 Johnson Controls Unitary Products ALL SENSIBLE CAPACITIES T ABLE 3: COOLING CAP ACITIES - 1 -1/2 T ON (DEB018) TEMPERATURE OF AIR ON OUTDOOR COIL AIR ON INDOOR COIL 450 CFM 525 CFM 600 CFM 675 CFM 750 CFM WB °F WB °F WB °F WB °F WB °F 72 67 62 57 72 67 6 2 57 72 67 62 57 72 67 62 57 72 67 6 2 57 85 °F Net Cap MBH 18.1 17.3 ...

  • York AFFINITY 360101-XTG-A-0108 - page 7

    360101-XTG-A-0108 Johnson Controls Unitary Products 7 ALL SENSIBLE CAPACITIES T ABLE 4: COOLING CAP ACITIES - 2 T ON (DEB024) TEMPERATURE OF AIR ON OUTDOOR COIL AIR ON INDOOR COIL 600 CFM 700 CFM 800 CFM 900 CFM 1,000 CFM WB °F WB °F WB °F WB °F WB °F 72 67 62 57 72 67 6 2 57 72 67 62 57 72 67 62 57 72 67 6 2 57 85 °F Net Cap MBH 25.1 23.0 21 ...

  • York AFFINITY 360101-XTG-A-0108 - page 8

    360101-XTG-A-0108 8 Johnson Controls Unitary Products ALL SENSIBLE CAPACITIES T ABLE 5: COOLING CAP ACITIES - 2 -1/2 T ON (DEB030) TEMPERATURE OF AIR ON OUTDOOR COIL AIR ON INDOOR COIL 750 CFM 875 CFM 1,000 CFM 1,125 CFM 1,250 CFM WB °F WB °F WB °F WB °F WB °F 72 67 62 57 72 67 6 2 57 72 67 62 57 72 67 62 57 72 67 6 2 57 85 °F Net Cap MBH 32. ...

  • York AFFINITY 360101-XTG-A-0108 - page 9

    360101-XTG-A-0108 Johnson Controls Unitary Products 9 ALL SENSIBLE CAPACITIES T ABLE 6: COOLING CAP ACITIES - 3 T ON (DEB036) TEMPERATURE OF AIR ON OUTDOOR COIL AIR ON INDOOR COIL 900 CFM 1,050 1,200 1,350 1,500 WB °F WB °F WB °F WB °F WB °F 72 67 62 57 72 67 6 2 57 72 67 62 57 72 67 62 57 72 67 6 2 57 85 °F Net Cap MBH 34.7 32.3 28.5 28.4 36 ...

  • York AFFINITY 360101-XTG-A-0108 - page 10

    360101-XTG-A-0108 10 Johnson Controls Unitary Products ALL SENSIBLE CAPACITIES T ABLE 7: COOLING CAP ACITIES - 3 -1/2 T ON (DEB042) TEMPERATURE OF AIR ON OUTDOOR COIL AIR ON INDOOR COIL 1,050 CFM 1,225 1,400 1,575 1,750 WB °F WB °F WB °F WB °F WB °F 72 67 62 57 72 67 6 2 57 72 67 62 57 72 67 62 57 72 67 6 2 57 85 °F Net Cap MBH 40.7 39.0 36.5 ...

  • York AFFINITY 360101-XTG-A-0108 - page 11

    360101-XTG-A-0108 Johnson Controls Unitary Products 11 ALL SENSIBLE CAPACITIES T ABLE 8: COOLING CAP ACITIES - 4 T ON (DEB048) TEMPERATURE OF AIR ON OUTDOOR COIL AIR ON INDOOR COIL 1200 CFM 1400 CFM 1600 CFM 1800 CFM 2000 CFM WB °F WB °F WB °F WB °F WB °F 72 67 62 57 72 67 6 2 57 72 67 62 57 72 67 62 57 72 67 6 2 57 85 °F Net Cap MBH 49.2 46. ...

  • York AFFINITY 360101-XTG-A-0108 - page 12

    360101-XTG-A-0108 12 Johnson Controls Unitary Products ALL SENSIBLE CAPACITIES T ABLE 9: COOLING CAP ACITIES - 5 T ON (DEB060) TEMPERATURE OF AIR ON OUTDOOR COIL AIR ON INDOOR COIL 1200 CFM 1400 CFM 1600 CFM 1800 CFM 2000 CFM WB °F WB °F WB °F WB °F WB °F 72 67 62 57 72 67 6 2 57 72 67 62 57 72 67 62 57 72 67 6 2 57 85 °F Net Cap MBH 65.2 59. ...

  • York AFFINITY 360101-XTG-A-0108 - page 13

    360101-XTG-A-0108 Johnson Controls Unitary Products 13 Note: 1. D educt these resistance values from t he available external static pressure show n in the respective Blower Performance T able. 2. The pressure thru the economizer is greater for 100 % outdoor air then for 100% return air. If the resistance of the return a ir duct system is less then ...

  • York AFFINITY 360101-XTG-A-0108 - page 14

    360101-XTG-A-0108 14 Johnson Controls Unitary Products * KW listed is for 240 volts, use tabl e at top of p age for 208 or 230 volts. T ABLE 12: ELECTRICAL DA T A (BASIC UNIT) Model DEB Volt Voltage Limitations 1 1. Rated in accordance with ARI St andard 110, utilization ran ge “A”. Compressors Cond. Fan Motors Supply Air Blower Motor MCA (Amps ...

  • York AFFINITY 360101-XTG-A-0108 - page 15

    360101-XTG-A-0108 Johnson Controls Unitary Products 15 FIGURE 3 - UNIT DIMENSIONS HIGH VO L TAGE CONN. “ x " DIA. KNOCKOUT 6 DRAIN “ NPTI CONDENS A TE LOW VO L TAGE CONN. “ DIA. KNOCKOUT FRONT CONDENSER COIL 15 4 BACK SIDE RETURN AIR OPENING SIDE SUPP L Y AIR OPENING BOT T OM RETURN AIR OPENING 15 2 1 1 1 15 BOT T OM SUPP L Y AIR OPENING ...

  • York AFFINITY 360101-XTG-A-0108 - page 16

    360101-XTG-A-0108 16 Johnson Controls Unitary Products FIGURE 4 - CENTER OF GRAVITY T ABLE 14: UNIT WEIGHTS Unit Size Shipping Weight Operating Weight Corner Weights Economizer (lbs.) Roof Curb (lbs.) ABC D 018 318 313 86 76 73 83 40 8" - 70 14" - 75 024 324 319 88 77 75 85 030 333 328 85 81 82 86 036 338 333 91 80 78 88 042 347 342 94 83 ...

  • York AFFINITY 360101-XTG-A-0108 - page 17

    360101-XTG-A-0108 Johnson Controls Unitary Products 17 TYPICAL APPLICATIONS FIGURE 5 - TYPICAL SLAB ON GROUND INSTALLATION FIGURE 6 - TYPICAL ROOF CURB INSTALLATION TO POWER SUPPL Y SUPPL Y AIR DUCT RETURN AIR DUCT FIELD SUPPLIED DISCONNECT SWITCH LOCA TED TO REAR OF UNIT CONTROL WIRING TO INDOOR THERMOST A T SLAB ON GROUND INST ALLATION ROOF CURB ...

  • York AFFINITY 360101-XTG-A-0108 - page 18

    360101-XTG-A-0108 18 Johnson Controls Unitary Products FIGURE 7 - ROOF CURB DIMENSIONS (8 ” Roof curb al so available) FIGURE 8 - ROOF CURB APPLICATION FRONT 1 1 WOOD NAILER 4 INSULA TED P ANELS 22 14 OPENING FOR RETURN AIR DUCT OPENING FOR SUPPL Y AIR DUCT RECOMMENDED DUCT SIZE SUPPL Y AIR DUCT " x " RETURN AIR DUCT " x " UNI ...

  • York AFFINITY 360101-XTG-A-0108 - page 19

    360101-XTG-A-0108 Johnson Controls Unitary Products 19 FIGURE 9 - TYPICAL WIRING DIAGRAM ( 208/230-1-60 POWER SUPPLY) DEB MODEL S 15695BASH0301 SEE DET AIL "A" T2 M1 - 2 DET AIL "A" BLK BLK CCH L1 T1 OPTIONAL CCH S / P CONFIGURA TION BLK BLK CCH L1 D / P CONFIGURA TION L 2 L 2 ...

  • York AFFINITY 360101-XTG-A-0108 - page 20

    360101-XTG-A-0108 20 Johnson Controls Unitary Products MECHANICAL SPECIFICATIONS GENERAL DESCRIPTION Units shall be factory-assembl ed, single packaged, Electric Cooling units, desi gned for outdo or mounted installation . They shall have built in, equal size, field convertibl e duct connections for down discharge supply/return or horizontal discha ...

  • York AFFINITY 360101-XTG-A-0108 - page 21

    360101-XTG-A-0108 Johnson Controls Unitary Products 21 4. Unit Controls: a. Unit shall contain a large, l ow voltage Te rmi nal Board for easy connection of fi eld low voltage wiring. b. Controls shall be moun ted in a large co ntrol box with tilt- out, hinged access door, allowing easy acce ss for trouble shooting and mainte nance without affectin ...

  • York AFFINITY 360101-XTG-A-0108 - page 22

    360101-XTG-A-0108 22 Johnson Controls Unitary Products ...

  • York AFFINITY 360101-XTG-A-0108 - page 23

    360101-XTG-A-0108 Johnson Controls Unitary Products 23 ...

  • York AFFINITY 360101-XTG-A-0108 - page 24

    Subject to change without notice. Print ed in U. S.A. 360101-XTG-A-0108 Copyright © 2008 by Johnson Controls, In c. All rights rese rved. Supersedes: 263146-X TG-A-0206/036-21753-0 01-A-0206 Johnson Cont rols Unitary Pr oducts 5005 York Drive Norman, OK 73069 ...

Производитель York Категория Air Conditioner

Документы, которые мы получаем от производителя устройства York AFFINITY 360101-XTG-A-0108 мы можем разделить на несколько групп. Это в частности:
- технические чертежи York
- инструкции обслуживания AFFINITY 360101-XTG-A-0108
- паспорта изделия York
- информационные брошюры
- энергетические этикетки York AFFINITY 360101-XTG-A-0108
Все из них важны, однако самую важную информацию с точки зрения пользователя мы найдем в инструкции обслуживания York AFFINITY 360101-XTG-A-0108.

Группа документов, определяемая как инструкции обслуживания, делится также на более подробные типы, такие как: Инструкции монтажа York AFFINITY 360101-XTG-A-0108, инструкции обслуживания, короткие инструкции или инструкции пользователя York AFFINITY 360101-XTG-A-0108. В зависимости от потребностей, Вам необходимо поискать требуемый документ. На нашем сайте Вы можете просмотреть самую популярную инструкцию использования изделия York AFFINITY 360101-XTG-A-0108.

Похожие инструкции обслуживания

Полная инструкция обслуживания устройства York AFFINITY 360101-XTG-A-0108, как должна выглядеть?
Инструкция обслуживания, определяемая также как пособие пользователя, или просто "руководство" - это технический документ, цель которого заключается в использовании York AFFINITY 360101-XTG-A-0108 пользователями. Инструкции пишет, как правило технический писатель, языком, доступным для всех пользователей York AFFINITY 360101-XTG-A-0108.

Полная инструкция обслуживания York, должна заключать несколько основных элементов. Часть из них менее важная, как например: обложка / титульный лист или авторские страницы. Однако остальная часть, должна дать нам важную с точки зрения пользователя информацию.

1. Вступление и рекомендации, как пользоваться инструкцией York AFFINITY 360101-XTG-A-0108 - В начале каждой инструкции, необходимо найти указания, как пользоваться данным пособием. Здесь должна находится информация, касающаяся местонахождения содержания York AFFINITY 360101-XTG-A-0108, FAQ и самых распространенных проблем - то есть мест, которые чаще всего ищут пользователи в каждой инструкции обслуживания
2. Содержание - индекс всех советов, касающихся York AFFINITY 360101-XTG-A-0108, которое найдем в данном документе
3. Советы по использованию основных функций устройства York AFFINITY 360101-XTG-A-0108 - которые должны облегчить нам первые шаги во время использования York AFFINITY 360101-XTG-A-0108
4. Troubleshooting - систематизированный ряд действия, который поможет нам диагностировать а в дальнейшем очередность решения важнейших проблем York AFFINITY 360101-XTG-A-0108
5. FAQ - чаще всего задаваемые вопросы
6. Контактные данные Информация о том, где искать контактные данные производителя / сервисного центра York AFFINITY 360101-XTG-A-0108 в данной стране, если самостоятельно не получится решить проблему.

У вас вопрос, касающийся York AFFINITY 360101-XTG-A-0108?

Воспользуйтесь формуляром, находящимся ниже

Если с помощью найденной инструкции Вы не решили свою проблему с York AFFINITY 360101-XTG-A-0108, задайте вопрос, заполнив следующий формуляр. Если у какого то из пользователей была похожая проблема с York AFFINITY 360101-XTG-A-0108 со всей вероятностью он захочет поделиться методом ее решения.

Перепишите текст с картинки

Комментарии (0)