  • A.O. Smith BTR 151 THRU 201/A - page 1

    1 MODELS BTR 151 THRU 201/A COMMERCIAL GAS, GLASS-LINED, TANK-TYPE WATER HEATER • INSTALLATION • OPERATION • MAINTENANCE • LIMITED WARRANTY PLACE THESE INSTRUCTIONS ADJACENT TO HEATER AND NOTIFY OWNER TO KEEP FOR FUTURE REFERENCE. Printed in U.S.A. 1004 P ART NO. 196308-001 A DIVISION OF A. O. SMITH CORPORA TION McBEE, SOUTH CAROLINA, USA w ...

  • A.O. Smith BTR 151 THRU 201/A - page 2

    2 FOREWORD These designs comply with ANSI Z21.10.3 as a Booster type water heater . Detailed installation diagrams are found in this manual. These diagrams will serve to provide the installer with a reference for the materials and methods of piping necessary . It is highly essential that all water , gas piping and wiring be installed as shown on th ...

  • A.O. Smith BTR 151 THRU 201/A - page 3

    3 GENERAL SAFETY INFORMA TION PRECAUTIONS DO NOT USE THIS APPLIANCE IF ANY P ART HAS BEEN UNDER W A TER. Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water . IF THE UNIT IS EXPOSED TO THE FOLLOWING, DO NOT OPERA TE HEA TER UNTIL ALL CO ...

  • A.O. Smith BTR 151 THRU 201/A - page 4

    4 OPERA TION OF THESE F ANS CAN PRODUCE A NEGA TIVE DRAFT IN THE AREA OF THE W A TER HEA TER PREVENTING THE PRODUCTS OF COMBUSTION FROM EXHAUSTING THROUGH THE CHIMNEY OR VENT PIPE. The venting of the water heater should be inspected by a qualified service technician at the time of installation and periodically thereafter to ensure a down-draft cond ...

  • A.O. Smith BTR 151 THRU 201/A - page 5

    5 possibility of changing the orientation by accidentally overtightening the inlet supply . Improper orientation of the Eliminator may cause temperature buildup issues or spells of colder than usual water temperatures. HIGH LIMIT SWITCH The digital thermostat (see Figure 3) contains the high limit (energy cutoff) sensor . The high limit switch inte ...

  • A.O. Smith BTR 151 THRU 201/A - page 6

    6 INST ALLA TION INSTRUCTIONS REQUIRED ABILITY INST ALLA TION OR SERVICE OF THIS W A TER HEA TER REQUIRES ABILITY EQUIV ALENT TO THA T OF A LICENSED TRADESMAN IN THE FIELD INVOL VED. PLUMBING , AIR SUPPL Y , VENTING , GAS SUPPL Y AND ELECTRICAL WORK A RE REQUIRED. WARNING F AILURE TO FOLLOW THESE INSTRUCTIONS CAN RESUL T IN SERIOUS PERSONAL INJUR Y ...

  • A.O. Smith BTR 151 THRU 201/A - page 7

    7 CARBONING OR SOOTING OF THE COMBUSTION CHAMBER, BURNERS AND FLUE TUBES AND CREA TES A RISK OF ASPHYXIA TION. Where an exhaust fan is supplied in the same room with a heater , sufficient openings for air must be provided in the walls. UNDERSIZED OPENINGS WILL CAUSE AIR TO BE DRA WN INTO THE ROOM THROUGH THE CHIMNEY , CAUSING POOR COMBUSTION. SOOTI ...

  • A.O. Smith BTR 151 THRU 201/A - page 8

    8 FIGURE 7 • Where a separate vent connection is not available and the vent pipe from the heater must be connected to a common vent with an oil burning furnace, the vent pipe should enter the smaller common vent or chimney at a point above the large vent pipe. MUL TIPLE HEA TER MANIFOLD When horizontally manifolding two or more heaters vent as sh ...

  • A.O. Smith BTR 151 THRU 201/A - page 9

    9 GAS PIPING Contact your local gas service company to ensure that adequate gas service is available and to review applicable installation codes for your area. Size the main gas line in accordance with T able 2. The figures shown are for straight lengths of pipe at 0.5 in. W .C. pressure drop, which is considered normal for low pressure systems. No ...

  • A.O. Smith BTR 151 THRU 201/A - page 10

    10 Do not subject the combination gas valve to inlet gas pressures of more than 14.0" W .C. - natural gas. A service regulator is necessary if higher gas pressures are encountered. Manifold gas pressure in inches of water column is 3.5. The gas pressure specified refers to flow pressure taken at pressure tap of automatic gas valve while heater ...

  • A.O. Smith BTR 151 THRU 201/A - page 11

    11 INST ALLA TION DIAGRAMS GENERAL The type, size and location of the relief valves must be in accordance with local codes. The locations of the relief valves shown in the installation diagrams are typical. The heater has a factory installed high temperature limit switch and temperature and pressure relief valve. Cold water lines to heater should b ...

  • A.O. Smith BTR 151 THRU 201/A - page 12

    12 VERTICAL ST ORAGE T ANK AND FORCED CIRCULA TION DANGER TEMPERA TURE SETTING SHOULD NOT EXCEED SAFE USE TEMPERATURE A T FIXTURES. SEE W A TER TEMPERATURE CONTROL WARNING ON P AGE 20. IF HIGHER PREHEA T TEMPERA TURES ARE NECESSAR Y TO OBT AIN ADEQUATE BOOSTER OUTPUT , ADD AN ANTI-SCALD V AL VE FOR HOT W A TER SUPPLIED TO FIXTURES. HORIZONT AL ST O ...

  • A.O. Smith BTR 151 THRU 201/A - page 13

    13 DANGER TEMPERA TURE SETTING SHOULD NOT EXCEED SAFE USE TEMPERA TURE A T FIXTURES. SEE W A TER TEMPERA TURE CONTROL W ARNING ON P AGE 20. IF HIGHER PREHEA T TEMPERA TURES ARE NECESSARY T O OBTAIN ADEQUA TE BOOSTER OUTPUT , ADD AN ANTI-SCALD V AL VE FOR HOT W A TER SUPPLIED TO FIXTURES. TWO TEMPERA TURE - ONE HEA TER HIGH TEMPERA TURE ST ORAGE WIT ...

  • A.O. Smith BTR 151 THRU 201/A - page 14

    14 INST ALLA TION DIAGRAMS-SIDE INLET/OUTLET USAGE DANGER TEMPERA TURE SETTING SHOULD NOT EXCEED SAFE USE TEMPERA TURE A T FIXTURES. SEE W A TER TEMPERA TURE CONTROL W ARNING ON PAGE 20. IF HIGHER PREHEA T TEMPERA TURES ARE NECESSARY TO OBT AIN ADEQUA TE BOOSTER OUTPUT , ADD AN ANTI-SCALD V AL VE FOR HOT W A TER SUPPLIED TO FIXTURES. A listed tempe ...

  • A.O. Smith BTR 151 THRU 201/A - page 15

    15 ONE OR TWO TEMPERATURE - ONE HEATERS,HIGH TEMPERATURE STORAGE WITH OR WITHOUT RECIRCULATION HEATER WITH OR WITHOUT MIXING VALVE HEATER WITH MIXING VALVE AND RECIRCULATED SANITIZING LOOP NOTE 1: TOGGLE SWITCH CONTROLS 180°F (82°C) W A TER CIRCULATION. INST ALL ON OR CLOSE TO DISHWASHING MACHINE. TOGGLE SWITCH MUST BE CLOSED (ON) DURING THE RINS ...

  • A.O. Smith BTR 151 THRU 201/A - page 16

    16 TWO TEMPERATURE - TWO PRE-HEATERS WITH MIXING VALVE OR BOOSTER HEATER WITH OR WITHOUT BUILING RECIRCULATION TWO PRE-HEATERS WITH MIXING VALVE TWO PRE-HEATERS WITH BOOSTER HEATER DANGER TEMPERA TURE SETTING SHOULD NOT EXCEED SAFE USE TEMPERA TURE A T FIXTURES. SEE WA TER TEMPERA TURE CONTROL W ARNING ON P AGE 20. IF HIGHER PREHEA T TEMPERA TURES ...

  • A.O. Smith BTR 151 THRU 201/A - page 17

    17 MEDIUM TEMPERATURE - ONE HEATER WITH AUXILIARY STORAGE TANK FORCED CIRCULATION WITH OR WITHOUT BUILDING RECIRCULATION VERTICAL STORAGE TANK HORIZONTAL STORAGE TANK DANGER TEMPERA TURE SETTING SHOULD NOT EXCEED SAFE USE TEMPERA TURE A T FIXTURES. SEE W A TER TEMPERA TURE CONTROL W ARNING ON P AGE 20. IF HIGHER PREHEA T TEMPERA TURES ARE NECESSAR ...

  • A.O. Smith BTR 151 THRU 201/A - page 18

    18 OPERA TION IMPORT ANT A qualified person must perform the initial firing of the heater . At this time the user should not hesitate to ask the individual any questions which they may have in regard to the operation and maintenance of the unit. An Operational Checklist is included at the rear of this manual. By using this checklist the user may be ...

  • A.O. Smith BTR 151 THRU 201/A - page 19

    19 A. This appliance does not have a pilot. It is equipped with an ignition device which automatically lights the burner . Do not try to light the burner by hand. B . BEFORE OPERA TING smell all around the appliance area for gas. Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor . “WHA T TO DO IF ...

  • A.O. Smith BTR 151 THRU 201/A - page 20

    20 set for 120° to 180°F water temperature, but 120°F is the recommended starting point. It is suggested the dial be placed on the lowest setting which produces an acceptable hot water supply . This will always give the most energy efficient operation. The temperature control has a 4°F (2°C) fixed differential. PREVENTIVE MAINTENANCE CHECK THE ...

  • A.O. Smith BTR 151 THRU 201/A - page 21

    21 NOTE: 1. Remove main burners from unit. 2. Check that burner venturi and ports are free of foreign debris. 3. Clean burners with bristle brush and/or vacuum cleaner - DO NOT distort burner ports or pilot location. 4. Reinstall burners in unit. Make sure front and rear of burners are installed correctly in burner support brackets. Also check for ...

  • A.O. Smith BTR 151 THRU 201/A - page 22

    22 RELIEF V AL VE At least once a year , the temperature and pressure relief valve should be checked to ensure that it is in operating condition. Lift the lever at the top of the valve several times until the valve seats properly and operates freely . If the appliance installation includes other relief valves, such as in “remote” storage tanks ...

  • A.O. Smith BTR 151 THRU 201/A - page 23

    23 FIGURE 14 DELIMING SOL VENTS A. O. Smith recommends the use of UN•LIME for deliming. UN•LIME is a patented food grade acid which is safe to handle and does not create the harmful fumes which are associated with other products. UN•LIME may be obtained from your dealer , distributor or the A. O. Smith Product Service Division. Order Part Num ...

  • A.O. Smith BTR 151 THRU 201/A - page 24

    24 the appliance. The indicator codes on the ignition module are as follows: 1 flash System lockout (retries or cycles exceeded) 2 flashes Pressure switch stuck close 3 flashes Pressure switch stuck open 4 flashes Open on high temperature limit switch (eco) 6 flashes 1 15 volt AC power reversed (check polarity) 7 flashes Low flame sense signal (mak ...

  • A.O. Smith BTR 151 THRU 201/A - page 25

    25 SEQUENCE OF OPERA TION FLOW CHART Description of this flow chart can be found in the “SEQUENCE OF OPERA TION” section found on page 18. Switch power on to unit. Thermostat calls for heat. Ignition Control Board performs diagnostic check on components Ignition Control Board sends power to Exhaust Inducer Exhaust Inducer engages Prover Switch ...

  • A.O. Smith BTR 151 THRU 201/A - page 26

    26 OPERA TIONAL CHECKLIST This checklist in conjunction with “TROUBLESHOOTING” and the “SEQUENCE OF OPERA TION” should be used as an on-the-job troubleshooting guide to identify the cause of incorrect system operation and suggest a remedy for its correction. Because improper piping and wiring can result in unsatisfactory system performance, ...

  • A.O. Smith BTR 151 THRU 201/A - page 27

    27 Model BTR Limited Warranty A. O. Smith Corporation, the warrantor , extends the following LIMITED WARRANTY to the owner of this water heater . 1. THE T ANK If the glass-lined tank in this water heater shall prove upon examination by the warrantor to have leaked due to natural corrosion from potable water therein, during the first THREE years aft ...

  • A.O. Smith BTR 151 THRU 201/A - page 28

    28 A.O. SMITH WATER PRODUCTS COMPANY 5621 W. 115TH STREET • ALSIP, ILLINOIS 60803 PHONE: 1-800-433-2545 • FAX: 1-800-433-2515 www.aosmithwaterheaters.com • E-MAIL: parts@hotwater.com ...

Производитель A.O. Smith Категория Water Heater

Документы, которые мы получаем от производителя устройства A.O. Smith BTR 151 THRU 201/A мы можем разделить на несколько групп. Это в частности:
- технические чертежи A.O. Smith
- инструкции обслуживания BTR 151 THRU 201/A
- паспорта изделия A.O. Smith
- информационные брошюры
- энергетические этикетки A.O. Smith BTR 151 THRU 201/A
Все из них важны, однако самую важную информацию с точки зрения пользователя мы найдем в инструкции обслуживания A.O. Smith BTR 151 THRU 201/A.

Группа документов, определяемая как инструкции обслуживания, делится также на более подробные типы, такие как: Инструкции монтажа A.O. Smith BTR 151 THRU 201/A, инструкции обслуживания, короткие инструкции или инструкции пользователя A.O. Smith BTR 151 THRU 201/A. В зависимости от потребностей, Вам необходимо поискать требуемый документ. На нашем сайте Вы можете просмотреть самую популярную инструкцию использования изделия A.O. Smith BTR 151 THRU 201/A.

Похожие инструкции обслуживания

Полная инструкция обслуживания устройства A.O. Smith BTR 151 THRU 201/A, как должна выглядеть?
Инструкция обслуживания, определяемая также как пособие пользователя, или просто "руководство" - это технический документ, цель которого заключается в использовании A.O. Smith BTR 151 THRU 201/A пользователями. Инструкции пишет, как правило технический писатель, языком, доступным для всех пользователей A.O. Smith BTR 151 THRU 201/A.

Полная инструкция обслуживания A.O. Smith, должна заключать несколько основных элементов. Часть из них менее важная, как например: обложка / титульный лист или авторские страницы. Однако остальная часть, должна дать нам важную с точки зрения пользователя информацию.

1. Вступление и рекомендации, как пользоваться инструкцией A.O. Smith BTR 151 THRU 201/A - В начале каждой инструкции, необходимо найти указания, как пользоваться данным пособием. Здесь должна находится информация, касающаяся местонахождения содержания A.O. Smith BTR 151 THRU 201/A, FAQ и самых распространенных проблем - то есть мест, которые чаще всего ищут пользователи в каждой инструкции обслуживания
2. Содержание - индекс всех советов, касающихся A.O. Smith BTR 151 THRU 201/A, которое найдем в данном документе
3. Советы по использованию основных функций устройства A.O. Smith BTR 151 THRU 201/A - которые должны облегчить нам первые шаги во время использования A.O. Smith BTR 151 THRU 201/A
4. Troubleshooting - систематизированный ряд действия, который поможет нам диагностировать а в дальнейшем очередность решения важнейших проблем A.O. Smith BTR 151 THRU 201/A
5. FAQ - чаще всего задаваемые вопросы
6. Контактные данные Информация о том, где искать контактные данные производителя / сервисного центра A.O. Smith BTR 151 THRU 201/A в данной стране, если самостоятельно не получится решить проблему.

У вас вопрос, касающийся A.O. Smith BTR 151 THRU 201/A?

Воспользуйтесь формуляром, находящимся ниже

Если с помощью найденной инструкции Вы не решили свою проблему с A.O. Smith BTR 151 THRU 201/A, задайте вопрос, заполнив следующий формуляр. Если у какого то из пользователей была похожая проблема с A.O. Smith BTR 151 THRU 201/A со всей вероятностью он захочет поделиться методом ее решения.

Перепишите текст с картинки

Комментарии (0)