  • American Power Conversion MXA002 - page 1

    The world's most reliable power protection ® Matrix TM UPS Hard-wire kit accessory MXA001 MXA002 User's Manual American Power Conversion ...

  • American Power Conversion MXA002 - page 2

    Important safety instructions! Please read this manual! V euillez lire ce manuel! Bitte lesen Sie dieses Anleitungshandbuch! ¡Se ruega leer este manual de instrucciones! PLEASE SA VE THIS MANUAL ! It includes important instructions for the safe use and installation of the UPS and its accessories. CONSERVER CES INSTRUCTIONS ! Cette notice contient ...

  • American Power Conversion MXA002 - page 3

    Page 1 T able of contents 1.0 Introduction ................................................................................. 2 2.0 Presentation ................................................................................. 3 3. 0 Installation ................................................................................... 4 Input voltage requ ...

  • American Power Conversion MXA002 - page 4

    Page 2 1.0 Introduction The hard-wire kit allows the UPS's input and/or output terminals to be permanently secured to building service wiring. This kit is used in place of the power distribution plate and/or input cable plate originally furnished with the UPS. The kit contains input cable and output power distribution plates with "knock-o ...

  • American Power Conversion MXA002 - page 5

    Page 3 2.0 Presentation Power distribution plate Provides an interface for output hard-wiring of loads. It is used in place of the power distribution plate for cord connected equipment originally furnished with the UPS. Input cable plate Used to replace the input cable plate originally furnished with the UPS. It allows hard-wiring of the input conn ...

  • American Power Conversion MXA002 - page 6

    Page 4 3.0 Installation ■ W arning: Risk of electric shock exists inside the UPS. Input voltage tap selection and power distribution panel replacement should be performed only by qualified service personnel. ■ A vertissement: Un risque de choc électrique existe à lintérieur de lUPS. La sélection des fils de tension dentrée et le r ...

  • American Power Conversion MXA002 - page 7

    Page 5 3.0 Installation T able 3.2.1 Cable Size S tri p Length UP S M ode l Min im um Ma x i m um Input cable Output cable 300 0VA 2. 5 m m 2 12 A W G 1 0 .0 m m 2 8 AW G 12 m m 1/2" 9 m m 3/8" 500 0VA 6. 0 m m 2 10 A W G 1 0 .0 m m 2 8 AW G ■ Cable clamps The UPS is not furnished with cable clamps for strain relief. Use only approved ? ...

  • American Power Conversion MXA002 - page 8

    Page 6 3.0 Installation Input cable connections 3.3 Input wiring procedure - continued T o remove a knock-out, strike in the area shown with a nail set tool and hammer . Grasp the edge of the knock-out with pliers and twist until the knock-out is separated from the plate. Caution: The edge of the knock-out may be sharp! Example showing removal of ? ...

  • American Power Conversion MXA002 - page 9

    Page 7 3.0 Installation 3.3 Input wiring procedure - continued 3.3.4 Remove all three input cable wire connections from terminal block labeled L1 , and L2/N . 3.3.5 Remove all screws that secure the input cable plate. Use a pair of wire cutters to remove "tie wraps" binding the input cable to wires inside the Isolation Unit. T ake care no ...

  • American Power Conversion MXA002 - page 10

    Page 8 Unmating of UPS output power connector 3.0 Installation 3.4 Output wiring procedure 3.4.1 Be sure the input circuit breaker is switched off (0) and the input cable is unplugged and/ or has no power applied. Caution: Switching the circuit breaker to off (0) does not remove power to all of the Isolation Unit. Power to the UPS must be disconnec ...

  • American Power Conversion MXA002 - page 11

    Page 9 Diagram showing power distribution plate earth connection 3.0 Installation 3.4 Output wiring procedure - continued 3.4.4 Use a 3/8" wrench to remove the protective earth wire (green with yellow stripes) ring terminal fastened at the earthing stud on the Isolation Unit. 3.4.5 Remove the desired knock-out from the new power distribution p ...

  • American Power Conversion MXA002 - page 12

    Page 10 3.0 Installation 3.4 Output wiring procedure - continued 3.4.9 Choose the desired wiring connections from the illustrations on the following pages (Figure 3.4.1 through Figure 3.4.6 ). Insert the stripped wire ends into the appropriate output terminations block terminal and tighten the terminal screws. Caution: Overcurrent protection for ou ...

  • American Power Conversion MXA002 - page 13

    Page 11 3.0 Installation 3.4 Output wiring procedure - continued Figure 3.4.1 1 f , 208 V ac loads only 3000 V A model with MXA002 hard- wire kit: 15 Amp maximum. 5000 V A model with MXA001 hard- wire kit: 24 Amp maximum. Figure 3.4.2 1 f , 240 V ac loads only 3000 V A model with MXA002 hard- wire kit: 12.5 Amp maximum. 5000 V A model with MXA001 h ...

  • American Power Conversion MXA002 - page 14

    Page 12 3.0 Installation 3.4 Output wiring procedure - continued Figure 3.4.5 1 f , 120/240 V ac loads ■ ■ ■ ■ ■ 3000 V A model with MXA002 hard- wire kit Each 120 V ac output: 25 Amp maxi- mum. 240 V ac output: 12.5 Amp maximum. T otal output: not to exceed 3000 V A . ■ ■ ■ ■ ■ 5000 V A model with MXA001 hard- wire kit Each 120 ...

  • American Power Conversion MXA002 - page 15

    Limited W arranty American Power Conversion (APC) warrants its products to be free from defects in materials and workmanship for a period of two years from the date of purchase. Its obligation under this warranty is limited to repairing or replacing, at its own sole option, any such defective products. To obtain service under warranty you must obta ...

  • American Power Conversion MXA002 - page 16

    Customer Service Note: Before calling the customer service number , please have available your UPS's serial number (see the label at the rear of the UPS). ( PHONE (+33) 1.64.62.59.00 in Europe (401) 789-5735 world wide * MAILING American Power Conversion 4, rue Ste Claire Deville Zac du Mandinet-Bâtiment Espace LOGNES 77447 MARNE LA V ALLEE C ...

Производитель American Power Conversion Категория Power Supply

Документы, которые мы получаем от производителя устройства American Power Conversion MXA002 мы можем разделить на несколько групп. Это в частности:
- технические чертежи American Power Conversion
- инструкции обслуживания MXA002
- паспорта изделия American Power Conversion
- информационные брошюры
- энергетические этикетки American Power Conversion MXA002
Все из них важны, однако самую важную информацию с точки зрения пользователя мы найдем в инструкции обслуживания American Power Conversion MXA002.

Группа документов, определяемая как инструкции обслуживания, делится также на более подробные типы, такие как: Инструкции монтажа American Power Conversion MXA002, инструкции обслуживания, короткие инструкции или инструкции пользователя American Power Conversion MXA002. В зависимости от потребностей, Вам необходимо поискать требуемый документ. На нашем сайте Вы можете просмотреть самую популярную инструкцию использования изделия American Power Conversion MXA002.

Похожие инструкции обслуживания

Полная инструкция обслуживания устройства American Power Conversion MXA002, как должна выглядеть?
Инструкция обслуживания, определяемая также как пособие пользователя, или просто "руководство" - это технический документ, цель которого заключается в использовании American Power Conversion MXA002 пользователями. Инструкции пишет, как правило технический писатель, языком, доступным для всех пользователей American Power Conversion MXA002.

Полная инструкция обслуживания American Power Conversion, должна заключать несколько основных элементов. Часть из них менее важная, как например: обложка / титульный лист или авторские страницы. Однако остальная часть, должна дать нам важную с точки зрения пользователя информацию.

1. Вступление и рекомендации, как пользоваться инструкцией American Power Conversion MXA002 - В начале каждой инструкции, необходимо найти указания, как пользоваться данным пособием. Здесь должна находится информация, касающаяся местонахождения содержания American Power Conversion MXA002, FAQ и самых распространенных проблем - то есть мест, которые чаще всего ищут пользователи в каждой инструкции обслуживания
2. Содержание - индекс всех советов, касающихся American Power Conversion MXA002, которое найдем в данном документе
3. Советы по использованию основных функций устройства American Power Conversion MXA002 - которые должны облегчить нам первые шаги во время использования American Power Conversion MXA002
4. Troubleshooting - систематизированный ряд действия, который поможет нам диагностировать а в дальнейшем очередность решения важнейших проблем American Power Conversion MXA002
5. FAQ - чаще всего задаваемые вопросы
6. Контактные данные Информация о том, где искать контактные данные производителя / сервисного центра American Power Conversion MXA002 в данной стране, если самостоятельно не получится решить проблему.

У вас вопрос, касающийся American Power Conversion MXA002?

Воспользуйтесь формуляром, находящимся ниже

Если с помощью найденной инструкции Вы не решили свою проблему с American Power Conversion MXA002, задайте вопрос, заполнив следующий формуляр. Если у какого то из пользователей была похожая проблема с American Power Conversion MXA002 со всей вероятностью он захочет поделиться методом ее решения.

Перепишите текст с картинки

Комментарии (0)