  • PB Heat WV Series - page 1

    WB V/WV Boilers Series Oil Installation, Operation & Maintenance Manual As an E NERGY S TA R ® Partner, PB Heat, LLC has determined that certain firing rates of this product meet the E NERGY S TA R ® guidelines for energy efficiency . ...

  • PB Heat WV Series - page 2

    USING THIS MANUAL 1 A . INST ALLA TION CLEARANCE . . . . . . . . . . . . .1 B . SPECIAL A TTENTION BOXES . . . . . . . . . . . .1 1. PREINST ALLA TION 2 A . CLEARANCES . . . . . . . . . . . . . . . . . . . . . . . .2 B . AIR FOR COMBUSTION AND VENTILA TION . . . . . . . . . . . . . . . . . . . . . . . . .2 C. CHIMNEY / VENT AND DRAFT CONTROL . .3 D ...

  • PB Heat WV Series - page 3

    1 A. INST ALLA TION CLEARANCE F ollow the installation instructions provided in this manual in the order shown. The order of these instructions has been set in order to provide the installer with a logical sequence of steps that will minimize potential interferences and maximize safety during boiler installation. B. SPECIAL A TTENTION BO XES Throug ...

  • PB Heat WV Series - page 4

    2 A. CLEARANCES Unit may be installed on combustible flooring, provided the boiler is not set on carpet and a metal drip pan is placed under the appliance. Unit may be installed in a closet with the above clearances. See also Section B, Air for Combustion and V entilation. B. AIR FOR COMBUSTION AND VENTILA TION 1. Be certain adequate facilities are ...

  • PB Heat WV Series - page 5

    3 C. CHIMNEY / VENT AND DRAFT CONTROL 1. Draft Requirement – Minimum draft r equir ed in the vent system is -.03" to -.06" W .C. depending on boiler model, see T able 7.1 (Section 7). This draft is necessary to provide the necessar y draft over fire of -.01" to -.02" W .C. See discussion in paragraph 5 below regarding draft. 2 ...

  • PB Heat WV Series - page 6

    4 A. SETTING THE BOILER 1. Provide a level foundation, located as close as possible to the center of the heating system. 2. Refer to Figur es 2.1 and 2.2 for e xploded view of boiler while checking and/or assembling parts of the boiler . 3. On packaged boilers, open burner mounting plate (item 5) at this time to make certain the target wall (item 2 ...

  • PB Heat WV Series - page 7

    BOILER PLA CEMENT AND ASSEMBL Y (See T able 8.1 for parts identification). Figure 2.1: Steam boiler 5 Figure 2.2: W ater boiler ...

  • PB Heat WV Series - page 8

    A. PRESSURE TEST BLOCK ASSEMBL Y 1. Make up cold water supply connection to the boiler . 2. Install pressur e gauge or pr essure-temperatur e gauge in tapping provided. See Boiler Dimensional drawing, Figur es 7.1 and 7.2 (Section 7) 3. Plug all open tappings in the boiler and fill with water . Apply approximately thirty (30) psig pressur e. Check ...

  • PB Heat WV Series - page 9

    7 E. T ANKLESS HEA TER OR CO VERPLA TE 1. If a tankless coil is used (item 9), install as pictured. On water boilers, install in opening in front section. On steam boilers, install in opening in rear section. F or suggested piping of tankless water heaters refer to Figur es 3.3 and 3.4. 2. If not using a tankless coil, cover the heater opening with ...

  • PB Heat WV Series - page 10

    8 Figure 3.6: Piping with P eerless Indirect Water T ank Figure 3.7: Float Low Water Cut -off PIPING AND CONTROLS Figure 3.5: Piping to Isolate Boiler from Chilled Medium on Chiller Systems ...

  • PB Heat WV Series - page 11

    9 A. GENERAL All electrical wiring shall be done in accordance with the National Electrical Code and Local Requirements. Single pole switches including those of safety controls or protective devices shall not be wired in a grounded line. B. BURNER WIRING 1. See Section 5 for mounting burner . 2. Install junction box, limit harness, and Heyco bushin ...

  • PB Heat WV Series - page 12

    10 ELECTRICAL Figure 4.3: Water Boilers, P ackaged Figure 4.2: Water Boilers, Knockdown ...

  • PB Heat WV Series - page 13

    11 ELECTRICAL Figure 4.5: Steam with Probe Low W ater Cut -off Figure 4.4: Steam with Float Low Water Cut - Off ...

  • PB Heat WV Series - page 14

    12 ELECTRICAL Figure 4.6: Zoning with Circulators Figure 4.7: Zoning with Zone V alves ...

  • PB Heat WV Series - page 15

    13 BURNER SETUP & BOILER OPERA TION A. BURNER INST ALLA TION 1. The oil burner is supplied with a mounting flange fixed in position. 2. Mount the burner to the bur ner mounting plate (item 5) with four (4) 5/16" studs and nuts provided. 3. Care must be taken when routing the oil lines so not to interfere with the opening and closing of the ...

  • PB Heat WV Series - page 16

    14 BURNER SETUP & BOILER OPERA TION E. CLEAN THE BOILER (STEAM BOILERS ONL Y) 1. Clean the boiler within one week after initial start-up. Cleaning will be more effective if boiler operates a day or two to loosen sediment and impurities in system. 2. Boiler must be cleaned to remove any accumulation of oil, grease, sludge, etc. in the system. Th ...

  • PB Heat WV Series - page 17

    15 BURNER SETUP & BOILER OPERA TION BECKETT BURNER SPECIFIC A TIONS Boiler Model No . Burner Model No . Burner Head Static Plate Nozzle Size Pum p Pressure Start-up Settings Head Setting Air Shutter Air Band WBV -03-085 AFG- F3¹ F3 3-3/8" 0.75 80° B HAGO³ 140 PSI 6.0 1 N/A WBV -03-105 AFG- F4 F4 3-3/8" 0.90 80° B HAGO 140 PSI 6.0 ...

  • PB Heat WV Series - page 18

    16 MAINTENANCE 6. MAINTENANCE W ARNING Product Saf ety Inf ormation Refractory Ceramic Fiber Product This appliance contains materials made from refractory ceramic fiber s (RCF). Airborne RCF , when inhaled, ha ve been c lassified by the International Agency f or Resear ch on Cancer (IARC), as a possib le carcinogen to humans. After the RCF materia ...

  • PB Heat WV Series - page 19

    17 MAINTENANCE A. GENERAL 1. Check pipes adjacent to cold walls or in unheated spaces. Insulate and tape them if necessary to be sure they can't fr eeze up. Keeping the water moving at all times will reduce the likelihood of fr eezing. 2. If there is considerable for eign matter in the boiler water , the boiler should be shut down and allowed ...

  • PB Heat WV Series - page 20

    18 MAINTENANCE 2. T o thoroughly clean the boiler it must be brushed down from the top. Alternatively , for limited space or minimum clearance to combustible installations, cleaning the heat e xchanger from the combustion chamber side is acceptable. If unit is e xtremely dirty , it may be necessary to brush from both directions. The target wall is ...

  • PB Heat WV Series - page 21

    19 BOILER DIMENSIONS & RA TINGS 7. BOILER DIMENSIONS & RA TINGS Figure 7.1: Boiler Dimensions, Water Boiler Figure 7.2: Boiler Dimensions, Steam Boiler Boiler Model Number Jack et Depth "A" Rear of Jack et to C/L of T op Flue Outlet "B" To p Flue Size "C" WBV -03-085/110 14-1/8" 7-1/16" 6" WBV -0 ...

  • PB Heat WV Series - page 22

    20 T able 7.1: Boiler Ratings ✸ As an ENERG Y ST AR ® P artner , PB Heat, LLC has determined that these firing rates meet the ENERG Y ST AR guidelines for energy efficiency . ✝ T op venting only . ✚ Nozzles for these firing rates not provided as standard equipment. Consult factory for price and availability . ✪ This firing rate can only be ...

  • PB Heat WV Series - page 23

    21 R E PA I R PA R T S 8. REP AIR P ARTS Repair par ts are available from your installer or by contacting PB Heat, LLC, 131 S. Church St, Bally , P A 19503. Note: Remember to include boiler model number and serial number when ordering par ts. T able 8.1 Item No .* Stock Code Description Additional Information 1 2 3 4 5 6 7 8 9 10 11 11A 12 13 14 15 ...

  • PB Heat WV Series - page 24

    22 NOTES ...

  • PB Heat WV Series - page 25

    23 NOTES ...

  • PB Heat WV Series - page 26

    PP8046 R26 (8/08-10M) Pri nte d i n U.S.A . ©2008 WB V/WV Boilers Series Oil Installation, Operation & Maintenance Manual TO THE INST ALLER: This manual is the property of the owner and must be affixed near the boiler for future reference. TO THE OWNER: This boiler should be inspected annually by a Qualified Service Agency. HI Division of gama ...

Производитель PB Heat Категория Boiler

Документы, которые мы получаем от производителя устройства PB Heat WV Series мы можем разделить на несколько групп. Это в частности:
- технические чертежи PB Heat
- инструкции обслуживания WV Series
- паспорта изделия PB Heat
- информационные брошюры
- энергетические этикетки PB Heat WV Series
Все из них важны, однако самую важную информацию с точки зрения пользователя мы найдем в инструкции обслуживания PB Heat WV Series.

Группа документов, определяемая как инструкции обслуживания, делится также на более подробные типы, такие как: Инструкции монтажа PB Heat WV Series, инструкции обслуживания, короткие инструкции или инструкции пользователя PB Heat WV Series. В зависимости от потребностей, Вам необходимо поискать требуемый документ. На нашем сайте Вы можете просмотреть самую популярную инструкцию использования изделия PB Heat WV Series.

Похожие инструкции обслуживания

Полная инструкция обслуживания устройства PB Heat WV Series, как должна выглядеть?
Инструкция обслуживания, определяемая также как пособие пользователя, или просто "руководство" - это технический документ, цель которого заключается в использовании PB Heat WV Series пользователями. Инструкции пишет, как правило технический писатель, языком, доступным для всех пользователей PB Heat WV Series.

Полная инструкция обслуживания PB Heat, должна заключать несколько основных элементов. Часть из них менее важная, как например: обложка / титульный лист или авторские страницы. Однако остальная часть, должна дать нам важную с точки зрения пользователя информацию.

1. Вступление и рекомендации, как пользоваться инструкцией PB Heat WV Series - В начале каждой инструкции, необходимо найти указания, как пользоваться данным пособием. Здесь должна находится информация, касающаяся местонахождения содержания PB Heat WV Series, FAQ и самых распространенных проблем - то есть мест, которые чаще всего ищут пользователи в каждой инструкции обслуживания
2. Содержание - индекс всех советов, касающихся PB Heat WV Series, которое найдем в данном документе
3. Советы по использованию основных функций устройства PB Heat WV Series - которые должны облегчить нам первые шаги во время использования PB Heat WV Series
4. Troubleshooting - систематизированный ряд действия, который поможет нам диагностировать а в дальнейшем очередность решения важнейших проблем PB Heat WV Series
5. FAQ - чаще всего задаваемые вопросы
6. Контактные данные Информация о том, где искать контактные данные производителя / сервисного центра PB Heat WV Series в данной стране, если самостоятельно не получится решить проблему.

У вас вопрос, касающийся PB Heat WV Series?

Воспользуйтесь формуляром, находящимся ниже

Если с помощью найденной инструкции Вы не решили свою проблему с PB Heat WV Series, задайте вопрос, заполнив следующий формуляр. Если у какого то из пользователей была похожая проблема с PB Heat WV Series со всей вероятностью он захочет поделиться методом ее решения.

Перепишите текст с картинки

Комментарии (0)