Friendly NET ® FM2017 SNMP/W eb Managed Sw itch w ith Fiber Option User ’ s Manual ...
-
Asante Technologies FM2017 - page 2
2 ...
-
Asante Technologies FM2017 - page 3
3 Table Of Contents Chapter 1. Introduction 5 Features 5 Ethernet Switching T echnology 6 Management M ethods 6 Chapter 2. Hardware Installation 7 Package Contents 7 Front Panel 7 Rear Panel 8 Mounting Configurations 8 Powering on the Switch 8 Optional FX100 M odules 8 Chapter 3. Network Application 1 1 Small W orkgroup 1 1 Segment Bridge 1 1 VLAN ...
-
Asante Technologies FM2017 - page 4
4 ...
-
Asante Technologies FM2017 - page 5
5 Chapter 1. I ntroduction Thank you for purchasing an Asanté Friendly NET FM 2017 SNMP/W eb managed switch. This sw itch is designed to build high-performance switched netw o rks. It uses store-and-forward technology , providing low latency for high-speed netw orking, and is targeted at workgroup, department or backbone computing environments at ...
-
Asante Technologies FM2017 - page 6
6 Ethernet Sw itching T echnology Ethernet switching technology has dramatically boosted the total bandwidth of a netw ork, eliminating congestion problems inherent with Carrier Sense M ultiple Access with Collision Detection (CSM A/CD) protocol, and has greatly reduced unnecessary transmissions. This revolutioniz ed networking in the follow ing wa ...
-
Asante Technologies FM2017 - page 7
7 Chapter 2. Hardw are Installation This chapter describes the front and rear panels of the FM 2017, and explains how to install, mount and apply pow er to the switch. Package Contents The sw itch is shipped with the follow ing items: • Switch • AC power cord • Four (4) Rubber feet • Rack mount Kit • RS-232 cable • User’s Manual (this ...
-
Asante Technologies FM2017 - page 8
8 Rear Panel The rear panel contains the Netw ork Management module and the 3-pronged power plug. T he switch uses AC in the range of 100-240V AC, 50-60Hz. The Netw ork Management module holds the Flash memory , and has two LEDs: CPU Fail : The CPU Fail LED is lit when the sw itch’s self test and initialization are in progress, after powering ...
-
Asante Technologies FM2017 - page 9
9 • FX100-M MC • FX100-SM C15 • FX100-SM C30 • FX100-SM C60 The FX 100 modules are designed to extend the allow able distance between the switch and other netw ork devices. The max imum distance that can be achieved with fiber cabling is 2 kilometers (multi-mode fiber) and up to 15, 30 or 60 kilometers (single-mode fiber). Front Panels The ...
-
Asante Technologies FM2017 - page 10
10 ...
-
Asante Technologies FM2017 - page 11
11 Chapter 3. Netw ork A pplication This section provides a few samples of network topology in w hich the switch can be used. In general, the switch is designed to be used as a segment switch. T hat is, with its large address table (8000 M AC address) and high performance, it is ideal for interconnecting networking segments. Y ou can use the switch ...
-
Asante Technologies FM2017 - page 12
12 ...
-
Asante Technologies FM2017 - page 13
13 Chapter 4. Netw ork Configurati on This chapter ex plains how to configure console management via a direct connection to the console port of the switch. Console management involves the administration of the sw itch via a direct connection to the RS-232 console port. This port is a female DB-9 connector . From the main menu of the console program ...
-
Asante Technologies FM2017 - page 14
14 ---<<Current configuration>>---------------------------[1.0(beta 2)]---- - [MAC=00:00:94:D1:1C:22] [IP=192.168.0.1] [mask=255.255.255.0] [broadcast=255.255.255.255] [gateway=0.0.0.0] ------------------------------------------------------------------------ - 1. boot-method = [flash] 2. ip-address = [192.168.0.1] 3. subnet mask = [255. ...
-
Asante Technologies FM2017 - page 15
15 E. Http server = [on] F. Telnet/Http username = [root] G. Telnet/Http password = [enabled] H. reboot I. logout J. ping K. help L. loaddefault M. securedip = [0.0.0.0],[0.0.0.0],[0.0.0.0] >>>> Press H to reboot the sw itch after making your change. Press Enter tw ice, and the new IP address w ill now be displayed. By the similar metho ...
-
Asante Technologies FM2017 - page 16
16 ...
-
Asante Technologies FM2017 - page 17
17 Chapter 5. Web-Based Management This section introduces the configuration and functions of the w eb-based management of switch. The FM 2017 provides an embedded HT ML w ebsite residing in the CPU module. It offers management features and allows users to manage the sw itch from anyw here on the network through a standard w eb browser . Sy stem Lo ...
-
Asante Technologies FM2017 - page 18
18 Inside the System page, the follow ing information about the switch is listed: Network Setting • IP address : 192.168.0.1 • Subnet Mask : 255.255.255.0 • Broadcast : 255.255.255.255 • Default gateway : 0.0.0.0 The configuration above is only a reference setting. If you w ant to reset or change the numbers, you can click Agent Config to c ...
-
Asante Technologies FM2017 - page 19
19 The data is automatically updated at regular interv als. Port Config Screen Y ou can use the Port Config page to disable/enable each port. By default, all the ports are Enabled . T o disable or enable a port: 1. Select the drop-down menu in the Status column. 2. Choose the status you w ant for each Ethernet and Fiber port. 3. Remember to click A ...
-
Asante Technologies FM2017 - page 20
20 T o set these parameters for a port: 1. Select the drop-down menu in Speed/Duplex column. 2. Select one of the following choices: Auto/flow control enabled, Auto/flow control disabled, 100Base- Tx /Full Duplex , 100Base-Tx /Half Duplex , 10Base-T/Full Duplex or 10Base-T/Half Duplex . 3. Click Apply . VLA N Screen A VLAN (Virtual LAN ) is a group ...
-
Asante Technologies FM2017 - page 21
21 A gent Con fig Screen In the Agent Config page, the switch’ s current configurations are displayed. Y ou can refer to the following Agent Config page for your ow n setting. Boot Method There are three modes of Boot M ethod: • FLASH : Boot y our system by flash settings. Flash memory resides in a chip and holds its content without pow er . So ...
-
Asante Technologies FM2017 - page 22
22 Default A gent Configuration The follow ing are the default values of the Agent Config of the switch. Y ou can change the information listed by entering new information (for example, you can change the sw itch’s IP address by directly typing in a new IP address). Click A pply after entering the information. • Boot-Method : flash • IP addre ...
-
Asante Technologies FM2017 - page 23
23 A ppendi x A . Troubl eshooting This section is intended to help you solv e the most common problems on the switch. If y ou still are having problems after reading through the information here, contact Asanté’s Technical Support for assistance. Your sw itch can easily be monitored through the LED indicators to assist in identifying problems. ...
-
Asante Technologies FM2017 - page 24
24 ...
-
Asante Technologies FM2017 - page 25
25 A ppendi x B. Inter net Explorer Setti ng If you are using Internet Ex plorer , you have to modify the brow ser setting to enable Java applets to use network ports. We used Internet Explorer 5.0 for the following demonstration. First, select ” Internet Optional ..” under “ T ools ” of the function bar , then follow the step-by-step instr ...
-
Asante Technologies FM2017 - page 26
26 6. Go back to Internet Options, then click Custom Level . 7. Scroll down to find Jav a . 8. Select Custom under Java and click Java Custom Settings . 9. Select the Edit Permissions tab. 10. Select Enable under Unsigned Content , and then press OK . ...
-
Asante Technologies FM2017 - page 27
27 A ppendix C. Specifications and Warranty Statement FriendlyNET FM 2017 Specificat ions Standards IEEE 802.3 10Base-T E thernet IEEE 802.3u 100Base-TX Fast E thernet ANSI/ IEE E 802.3 N-W ay auto-negotia tion Protoc ol CSMA/CD Maximum Forwarding Rate 14,880 pps per Et hernet port 148,800 pps per Fas t Ethernet port LED Indic ators Per Port: 10/10 ...
-
Asante Technologies FM2017 - page 28
28 Friendly NET FM2017 SNMP/Web Managed Swi tch with Fi ber Option User ’ s Manual Asanté T echnologies, Inc. 821 Fox Lane San Jose, CA 95131 USA SALES 800-662-9686 Home/Office Solutions 800-303-9121 Enterprise Solutions 408-435-8388 TECHNICAL SUPPORT 801-566-8991: W orldwide 801-303-3787: FAX www.a s an t e. c om support@asante.com Copyright 20 ...
У вас вопрос, касающийся Asante Technologies FM2017?
Воспользуйтесь формуляром, находящимся ниже
Если с помощью найденной инструкции Вы не решили свою проблему с Asante Technologies FM2017, задайте вопрос, заполнив следующий формуляр. Если у какого то из пользователей была похожая проблема с Asante Technologies FM2017 со всей вероятностью он захочет поделиться методом ее решения.