Инструкция обслуживания Omron Healthcare HEM-705CP

28 страниц 0.46 mb
Скачать

Перейти на страницу of 28

Summary
  • Omron Healthcare HEM-705CP - page 1

    A utomatic Blood P r essure Monitor with Printer Model HEM-705CP INSTRUCTION MANU AL R ENGLISH ESP AÑOL HEM-705CP-IM-US 7/19/05 9:26 AM Page 1 ...

  • Omron Healthcare HEM-705CP - page 2

    TITLE 2 TITLE T ABLE OF C ONTENTS Bef ore Using the Monitor Introduction ........................................................................................ 3 Important Safety Notes ....................................................................... 4 Before T aking a Measurement ........................................................... ...

  • Omron Healthcare HEM-705CP - page 3

    INTRODUCTION 3 Thank you for purchasing the Omron ® HEM-705CP Intellisense ® Automatic Blood Pressure Monitor with Printer F ill in for future r eference DA TE PURCHASED: ______ SERIAL NUMBER: ________ Staple your pur chase receipt here . Y our ne w digital blood pressure monitor uses the oscillometric method of blood pressure measurement. This m ...

  • Omron Healthcare HEM-705CP - page 4

    4 IMPORT ANT SAFETY NO TES T o assur e the corr ect use of the pr oduct basic safety measur es should always be followed including the pr ecautions listed below: þ Read all information in the instruction book and any other literature included in the box before using the unit. þ Contact your physician for specif ic information about your blood pre ...

  • Omron Healthcare HEM-705CP - page 5

    BEFORE T AKING A MEASUREMENT 5 T o ensure a reliable reading follo w these recommendations: 1. A v oid eating, smoking, and ex ercising for 30 minutes before taking a measurement. Rest for at least 15 minutes before taking the measurement. 2. Stress raises blood pressure. A v oid taking measurements during stressful times. 3. Measurements should be ...

  • Omron Healthcare HEM-705CP - page 6

    TITLE TITLE KNOW Y OUR UNIT ST AR T Button Paper Feed Pulse Rate Print Graph Date/T ime Display Heart Symbol Air T ube Memory Button S ystolic Blood Pressure ON/OFF Button Set Date/T ime Adjust Date/T ime Diastolic Blood Pressure Print All Data Print Current Data/Stop Printing Printer Cover Air Plug (Connects to Air Jack) Main Unit: Componen ts: A ...

  • Omron Healthcare HEM-705CP - page 7

    TITLE TITLE BA T TER Y INST ALL A TION/REPLA CEMENT 1. Press the ▼ OPEN indicator on the battery cov er and slide the cov er off in the direction of the arro w . 2. Install 4 “ AA” size batteries so the + (positi ve) and - (negati ve) polarities match the polarities of the battery compartment as indicated. 3. Replace the battery cov er . Main ...

  • Omron Healthcare HEM-705CP - page 8

    TITLE 8 TITLE C ONNEC TING THE PRINTER 1. Remov e the printer cord from around the printer unit. 2. Connect the printer to the blood pressure monitor . Insert the cable plug with the indicator facing upw ard. CA UTION: Inserting the cable plug in any other position will damage the monitor . HEM-705CP-IM-US 7/19/05 9:26 AM Page 8 ...

  • Omron Healthcare HEM-705CP - page 9

    9 L O ADING THE PRINTER P APER This printer uses OMR ON ® thermal paper , part number 90TRP . Use only this thermal paper or thermal paper of similar size, width 38mm, roll diameter not to exceed 26mm. NO TE: For information on where to purchase printer paper visit our website at www .omronhealthcare.com or call customer service at 1-800-634-4350. ...

  • Omron Healthcare HEM-705CP - page 10

    SET TING THE DA TE AND TIME 10 The Blood Pressure Monitor automatically stores up to 28 measurement v alues with the date and time. Set the monitor to the current date and time before taking a measurement for the f irst time. If the current date and time is not set, a default date and time will display . 1. SETTING THE YEAR When the batteries are i ...

  • Omron Healthcare HEM-705CP - page 11

    TITLE SET TING THE DA TE AND TIME 11 3. SETTING THE MONTH Press the ADJUST b utton to advance by increments of one month. Press the SET button to set the current month. The day flashes on the display . 4. SETTING THE D A Y Press the ADJUST b utton to advance by increments of one day . Press the SET button to set the current day . The hour flashes o ...

  • Omron Healthcare HEM-705CP - page 12

    TITLE 12 TITLE TITLE APPL Y ING THE ARM CUFF 1. Make sure the air plug is securely inserted in the main unit. 2. Remov e tight-fitting clothing from your upper arm. 3. Sit in a chair with your feet flat on the floor . Place your arm on a table so the cuf f is le vel with your heart. APPL YING THE CUFF ON THE LEFT UPPER ARM 4. Put your arm through t ...

  • Omron Healthcare HEM-705CP - page 13

    5. Pull the cuf f so the top and bottom edges are tightened e venly around your arm. 6. When the cuf f is positioned correctly , press the se wn hook material FIRML Y against the pile side of the cuf f. 7. Make certain the cuf f fits snugly around your arm. The cuf f should make good contact with your skin. NO TE: Y ou should be able to fit your in ...

  • Omron Healthcare HEM-705CP - page 14

    TITLE 14 TITLE TITLE T AKING A MEASUREMENT The monitor automatically determines your ideal inflation le vel. In rare circumstances when a higher inflation may be necessary , the monitor automatically re-inflates the cuf f up to 30mmHg higher than the initial inflation and restarts the measurement. The monitor detects the pulse during inflation. Do ...

  • Omron Healthcare HEM-705CP - page 15

    15 TITLE TITLE TITLE T AKING A MEASUREMENT ST ART 4. When the measurement is complete, the arm cuf f completely deflates. Y our blood pressure and pulse rate are displayed. 5. Press the ON/OFF b utton to turn the monitor off. NO TE: The monitor will automatically turn of f after fi ve minutes. INSTR UCTIONS FOR SPECIAL CONDITIONS If your systolic p ...

  • Omron Healthcare HEM-705CP - page 16

    Every time you complete a measurement the monitor stores t he b lo od pressure and pulse rate in the memory . The Blood Pressure Monitor automatically stores up to 28 measurement v alues. When 28 sets of measurement v alues are stored in the memory , the oldest record is deleted to sa ve the most recent measurement v alues. TO DISPLA Y THE MEASUREM ...

  • Omron Healthcare HEM-705CP - page 17

    17 TITLE TITLE USING THE PRINTER The HEM-705CP printer unit has the capability to print all the of measurement v alues stored in the memory of the Blood Pressure Monitor . NO TES: • The correct date and time must be set up on the monitor before taking a reading. If the date and time is not set, the numerical v alues will not appear on the print o ...

  • Omron Healthcare HEM-705CP - page 18

    TITLE 18 TITLE USING THE PRINTER 2. TO PRINT ALL THE MEASUREMENT V ALUES Press the ALL D A T A b utton. The numeric printout will list all of the readings stored in the memory starting with the oldest reading to the most recent reading follo wed by the average of all the stored readings. The stored data will print as illustrated in the follo wing e ...

  • Omron Healthcare HEM-705CP - page 19

    19 TITLE TITLE USING THE PRINTER 3. TO PRINT A GRAPH OF ALL MEASUREMENT V ALUES Press the GRAPH b utton. The graph will list all of the readings stored in the memory . The stored data will print as illustrated in the follo wing example: 50 1 00 1 5 0 200 mmHg 3-6 Diastolic Reading Systolic Reading A verage systolic reading of stored measurements A ...

  • Omron Healthcare HEM-705CP - page 20

    TITLE TITLE CARE AND MAINTENANCE T o keep your digital blood pr essure monitor in the best condition and pr otect the unit fr om damage follow the dir ections listed below: • K eep the monitor in the storage case when not in use. • Do not f orcefully bend the arm cuf f or air tube. Do not fold tightly . • Clean the monitor with a soft dry clo ...

  • Omron Healthcare HEM-705CP - page 21

    21 TITLE TITLE TITLE ERROR INDICA T ORS SYMBOL CA USE C ORREC TION Monitor did not detect pulse rate Remov e the arm cuff. Refer to “ Applying the arm cuf f” on page 12. W ait 2-3 minutes. T ake another measurement. Cuf f under -inflated Remove the arm cuf f. Read “T aking a Measurement” on page 14. W ait 2-3 minutes. T ake another measurem ...

  • Omron Healthcare HEM-705CP - page 22

    TITLE 22 22 TITLE TITLE TROUBLESHOO TING TIPS PROBLEM CA USES SOL UTIONS No power . W orn batteries Incorrect battery installation Replace all 4 "AA" batteries. Reference page 7. Check the battery installation or proper placement of the battery polarities. No data will print. Printer not connected Cable plug not inserted correctly or dama ...

  • Omron Healthcare HEM-705CP - page 23

    QUICK REFERENCE GUIDE T o ensure a reliable reading, a void eating, smoking, and e xercising for 30 minutes before taking a measurement. Y ou should try to measure your blood pressure at the same time each day . A void taking measurements during stressful times. 1. Remov e any tight-fitting clothing from your upper arm. 2. Sit in a chair with your ...

  • Omron Healthcare HEM-705CP - page 24

    QUICK REFERENCE GUIDE 24 5. Press the ON/OFF b utton. Display symbols appear . 6. Press the ST AR T b utton. The cuf f starts to inflate automatically . Remain still and do not talk during the measurement. NO TE: T o stop the inflation or measurement, push the ST AR T/STOP button. The monitor will stop inflating, start deflating, and will turn of f ...

  • Omron Healthcare HEM-705CP - page 25

    25 TITLE TITLE TITLE FCC ST A TEMENT Note: PO TENTIAL FOR RADIO/TELEVISION INTERFERENCE (for U.S.A. only) This product has been tested and found to comply with the limits for a Class B digital de vice, pursuant to part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference in a residential insta ...

  • Omron Healthcare HEM-705CP - page 26

    TITLE 26 TITLE W ARRANTY Y our HEM-705CP , IntelliSense Automatic Blood Pressure Monitor , excluding the monitor cuf f, is warranted to be free from defects in materials and workmanship appearing within 5 years from the date of purchase, when used in accordance with the instructions provided with the monitor . The monitor cuff is w arranted to be f ...

  • Omron Healthcare HEM-705CP - page 27

    NO TE: These specif ications are subject to change without notice. 27 TITLE TITLE SPECIFICA TIONS Model: HEM-705CP Display: LCD Digital Display Measurement Range: Pressure: 0 to 299 mmHg Pulse: 40 to 180/minute Accur ac y/Calibration: Pressure: ±3 mmHg Pulse: ±5% of reading Inflation: Automatic by electric pump Deflation: Acti ve electronic contr ...

  • Omron Healthcare HEM-705CP - page 28

    Made in China Manufactured by OMR ON Distributed by: OMR ON HEAL THCARE, INC. 1200 Lak eside Dri ve Bannockburn, Illinois 60015-1243 www .omronhealthcare.com © 2005 OMR ON HEAL THCARE, INC. 705CPINST Re v B HEM-705CP-IM-US 7/19/05 9:26 AM Page 28 ...

Производитель Omron Healthcare Категория Blood Pressure Monitor

Документы, которые мы получаем от производителя устройства Omron Healthcare HEM-705CP мы можем разделить на несколько групп. Это в частности:
- технические чертежи Omron Healthcare
- инструкции обслуживания HEM-705CP
- паспорта изделия Omron Healthcare
- информационные брошюры
- энергетические этикетки Omron Healthcare HEM-705CP
Все из них важны, однако самую важную информацию с точки зрения пользователя мы найдем в инструкции обслуживания Omron Healthcare HEM-705CP.

Группа документов, определяемая как инструкции обслуживания, делится также на более подробные типы, такие как: Инструкции монтажа Omron Healthcare HEM-705CP, инструкции обслуживания, короткие инструкции или инструкции пользователя Omron Healthcare HEM-705CP. В зависимости от потребностей, Вам необходимо поискать требуемый документ. На нашем сайте Вы можете просмотреть самую популярную инструкцию использования изделия Omron Healthcare HEM-705CP.

Похожие инструкции обслуживания

Полная инструкция обслуживания устройства Omron Healthcare HEM-705CP, как должна выглядеть?
Инструкция обслуживания, определяемая также как пособие пользователя, или просто "руководство" - это технический документ, цель которого заключается в использовании Omron Healthcare HEM-705CP пользователями. Инструкции пишет, как правило технический писатель, языком, доступным для всех пользователей Omron Healthcare HEM-705CP.

Полная инструкция обслуживания Omron Healthcare, должна заключать несколько основных элементов. Часть из них менее важная, как например: обложка / титульный лист или авторские страницы. Однако остальная часть, должна дать нам важную с точки зрения пользователя информацию.

1. Вступление и рекомендации, как пользоваться инструкцией Omron Healthcare HEM-705CP - В начале каждой инструкции, необходимо найти указания, как пользоваться данным пособием. Здесь должна находится информация, касающаяся местонахождения содержания Omron Healthcare HEM-705CP, FAQ и самых распространенных проблем - то есть мест, которые чаще всего ищут пользователи в каждой инструкции обслуживания
2. Содержание - индекс всех советов, касающихся Omron Healthcare HEM-705CP, которое найдем в данном документе
3. Советы по использованию основных функций устройства Omron Healthcare HEM-705CP - которые должны облегчить нам первые шаги во время использования Omron Healthcare HEM-705CP
4. Troubleshooting - систематизированный ряд действия, который поможет нам диагностировать а в дальнейшем очередность решения важнейших проблем Omron Healthcare HEM-705CP
5. FAQ - чаще всего задаваемые вопросы
6. Контактные данные Информация о том, где искать контактные данные производителя / сервисного центра Omron Healthcare HEM-705CP в данной стране, если самостоятельно не получится решить проблему.

У вас вопрос, касающийся Omron Healthcare HEM-705CP?

Воспользуйтесь формуляром, находящимся ниже

Если с помощью найденной инструкции Вы не решили свою проблему с Omron Healthcare HEM-705CP, задайте вопрос, заполнив следующий формуляр. Если у какого то из пользователей была похожая проблема с Omron Healthcare HEM-705CP со всей вероятностью он захочет поделиться методом ее решения.

Перепишите текст с картинки

Комментарии (0)