Инструкция обслуживания Friedrich WY13

20 страниц 0.57 mb
Скачать

Перейти на страницу of 20

Summary
  • Friedrich WY13 - page 1

    I nsta l l at io n an d O p e r at io n M an u al A ir Co nd it io ne r s and He at P umps 115-V olt : WS08, WS10, WS14 230 - V olt : WS10, WS13, WS16, WE10, WE13, WE16, WY10, WY13 Thru -the-w all 920 - 0 07 - 13 (8- 07) Temp/Hour C o o l M o n e y S a v e r ® F a n O n l y C l o c k S t a r t T i m e S t o p T i m e P o w e r Fan Speed Mode P M T ...

  • Friedrich WY13 - page 2

    2 920-007-13 T abl e of Cont ents Int rod u ct io n Econ omizing Ti ps ............................................................................................................. ............................................................................................................... 3 WS models How to op erate your Friedr ic h r oom air c ...

  • Friedrich WY13 - page 3

    3 920-007-13 Y our new Friedrich Room A ir Condit ioner has been c arefully engineered and man u fac ture d to give you many y ears of de pend able, ef fi cient operation, keeping your ro om at a c omfor t able temperature and hu mid i ty level. Many e xt ra fea tures have been built into your Friedrich Room A ir Condit ioner to assure quiet opera ...

  • Friedrich WY13 - page 4

    4 920-007-13 T o s tar t unit If your air condit ioner is installed and plugged into a prop er re c ep t a c le, it is ready to go. The fi rst time the un it i s started, th e compressor wil l delay for three minutes. See Automatic Comp onent Protection on the following page. 1 T o uch the Powe r but ton once. The unit will automat ic ally be in C ...

  • Friedrich WY13 - page 5

    5 920-007-13 T emp/Hour Cool Money Saver ® Fan O n ly Clock Start Time Stop Time Po w e r Fan Speed Mode PM Timer On/Of f Set Hour 72 2 3 4 8 9 10 11 12 13 1 6 5 7 23 4 10 11 12 14 1 6 5 7 9 8 13 T emp/Hour Po w e r PM Cool Fan O n ly Heat Clock Start Time Stop Time Smart Fan Fan Speed Mode Timer On/Of f Money Saver Set Hour 72 Fig u re 1 : WS Mod ...

  • Friedrich WY13 - page 6

    6 920-007-13 How to c lea n the ai r filt er Y o ur F riedr ich ro om air condit ioner is equipped with a Per mafoam reusable air fi lter which is not af fec ted by washing. The fi lter ser ves to remove dust, pollen, and other impurities f rom the air . KEE P THE FI L T ER CLE AN - A cl ogged, dir t y fi lter w ill reduc e the operating ef fi ...

  • Friedrich WY13 - page 7

    7 920-007-13 How to c han ge ai rflow dire c tion The DISCH ARGE G RILLE is inst alled at the fac tor y to provide 45 ˚ upward air fl ow into the r oom. (Directi on 1 in Figure 5). If a v er tic al air fl ow is desired (D irection 2) , the direction c an be change d by rotating the DISCH ARGE G RILLE. Unplug the air c onditioner . R e m o v e t ...

  • Friedrich WY13 - page 8

    8 920-007-13 Fig u re 6 TEST RESET W ARNING TE S T BE F O R E E AC H U S E 1 . PR E SS R E S ET BUTTON 2 . P LU G L DCI I NTO P O W E R R E C E P T AC LE 3. PR E SS TE S T BUTTON, R E S ET BUTTON S HOUL D P O P U P 4. PR E SS TE S T BUTTON, F O R U S E D O NOT U S E IF A BOVE TE S T FAI L S W HEN GR EEN L IG HT IS ON I T IS W O R K I N G PR O P E R ...

  • Friedrich WY13 - page 9

    9 920-007-13 Won ’ t c o ol If the unit operates, but won’t co ol, determine if the c ontrols are proper ly set. Wait three minutes before setting the t her mo stat to a coo ler positi on in order to check c ontro l sett ings. Check the fi lter and clean it thor oughly , if needed. Check to s ee if the vent door is close d. Check to see if th ...

  • Friedrich WY13 - page 10

    10 920-007-13 Wall pr epar a tion STEP 1 The wall opening required for a WSC S LEEVE is 1 7 ¼" high by 27 ¼ " wide. STEP 2 LINTELS must be used in opening of br ick veneer and masonr y walls to suppor t the mater ial above the WSC SLEEV E. The follow ing considerat ions should also be given: I ns tall ati on i ns tru c ti ons for WS C s ...

  • Friedrich WY13 - page 11

    11 920-007-13 I ns t a lla tion requir emen ts STEP 1 T h e W S C S L E E V E s h o u l d b e p o s i t i o n e d s o t h a t t h e DR A IN E X TENSI ON extends a minimum of 9 ⁄ 16 " beyond the OUTSI DE WALL (See Figure 7). STEP 2 The WSC SLEEV E must extend a minimum of ⅞ " be yond the IN SIDE WALL . STEP 3 The WSC SLEEV E must be in ...

  • Friedrich WY13 - page 12

    12 920-007-13 These instr uct ions are provided for installat ion of WallMaster air condit ioner chassis mo dels into thru -the -wall sleeves. This chassis has bee n UL ap prov ed with the slee ve list ed on the serial na meplat e of th i s c ha ss is . Im portan t wa rranty i nf orm a ti on is prov id ed on pa ges 1 7 and 18. K eep these instr uct ...

  • Friedrich WY13 - page 13

    13 920-007-13 These instr uct ions are provided for installat ion of WallMaster air condit ioner chassis mo dels into thru -the -wall sleeves. This chassis has bee n UL ap prov ed with the slee ve list ed on the serial na meplat e of th i s c ha ss is . Im portan t wa rranty i nf orm a ti on is pro vid ed on pa ges 1 7 and 18. K eep these instr uct ...

  • Friedrich WY13 - page 14

    14 920-007-13 STEP 5 CHASSIS SEAL GA SKET INST ALLA TION: After installing the shell, slide the c hassis into the shell stopping approximately 3" from f ull inser tion. Stuf f t he chassis seal gasket one inch deep between the chas sis and the shell ( see Figure 1 1 ) . Make sure the gaske t is installed beginning from th e lower right side c ...

  • Friedrich WY13 - page 15

    15 920-007-13 DK ( Drai n Kit) In the event that the outdoor temperature dr ops below 37°F , any water that re mains in the chas sis basepan is drained into the sleeve pan on WE and W Y mo dels to prevent freezing. (NO TE: In the cooling m ode of the WS, WE and W Y models, c ondensate over fl ow is p ossible in very humid c limates ) . For these ...

  • Friedrich WY13 - page 16

    16 920-007-13 Friedrich Air Conditioning Company P.O. Box 1540 San Antonio, TX 78295 210.357.4400 www.fr iedrich.com WALLMASTER £ THRU-THE-WALL AIR CONDITIONERS LIMITED WARRANTY FIRST YEAR A NY PA RT: If any part supplied by FRIEDRICH fails because of a defect in workmanship or material within twelve months from date of original purchase, FRIEDRIC ...

  • Friedrich WY13 - page 17

    17 920-007-13 Friedrich wants you to remain pleased with your Room Air Conditioner . Should further assistance be needed con cern ing this warranty , contact: RAC W arranty , Service and Parts Friedrich Air Conditioning Co. P .O. Box 1540 San Antonio, TX 78295-1540 Y our personal warranty registration recor d AL W A YS U SE F RIEDRICH F A CT OR Y A ...

  • Friedrich WY13 - page 18

    18 920-007-13 ...

  • Friedrich WY13 - page 19

    19 920-007-13 ...

  • Friedrich WY13 - page 20

    FRI ED RI CH A IR CO ND ITI O NI NG CO. Post O f fi ce B ox 1 5 4 0 • San A ntonio, T exas 7829 5 - 154 0 4200 N . Pan Am E xp res sway • San Antoni o, T exas 7821 8 - 521 2 21 0) 357 - 4 4 0 0 • F A X (21 0) 357 - 4 4 80 ww w .fri ed rich .com Printe d in the U.S. A . 920 - 0 07 - 13 (8- 07) ...

Производитель Friedrich Категория Air Conditioner

Документы, которые мы получаем от производителя устройства Friedrich WY13 мы можем разделить на несколько групп. Это в частности:
- технические чертежи Friedrich
- инструкции обслуживания WY13
- паспорта изделия Friedrich
- информационные брошюры
- энергетические этикетки Friedrich WY13
Все из них важны, однако самую важную информацию с точки зрения пользователя мы найдем в инструкции обслуживания Friedrich WY13.

Группа документов, определяемая как инструкции обслуживания, делится также на более подробные типы, такие как: Инструкции монтажа Friedrich WY13, инструкции обслуживания, короткие инструкции или инструкции пользователя Friedrich WY13. В зависимости от потребностей, Вам необходимо поискать требуемый документ. На нашем сайте Вы можете просмотреть самую популярную инструкцию использования изделия Friedrich WY13.

Похожие инструкции обслуживания

Полная инструкция обслуживания устройства Friedrich WY13, как должна выглядеть?
Инструкция обслуживания, определяемая также как пособие пользователя, или просто "руководство" - это технический документ, цель которого заключается в использовании Friedrich WY13 пользователями. Инструкции пишет, как правило технический писатель, языком, доступным для всех пользователей Friedrich WY13.

Полная инструкция обслуживания Friedrich, должна заключать несколько основных элементов. Часть из них менее важная, как например: обложка / титульный лист или авторские страницы. Однако остальная часть, должна дать нам важную с точки зрения пользователя информацию.

1. Вступление и рекомендации, как пользоваться инструкцией Friedrich WY13 - В начале каждой инструкции, необходимо найти указания, как пользоваться данным пособием. Здесь должна находится информация, касающаяся местонахождения содержания Friedrich WY13, FAQ и самых распространенных проблем - то есть мест, которые чаще всего ищут пользователи в каждой инструкции обслуживания
2. Содержание - индекс всех советов, касающихся Friedrich WY13, которое найдем в данном документе
3. Советы по использованию основных функций устройства Friedrich WY13 - которые должны облегчить нам первые шаги во время использования Friedrich WY13
4. Troubleshooting - систематизированный ряд действия, который поможет нам диагностировать а в дальнейшем очередность решения важнейших проблем Friedrich WY13
5. FAQ - чаще всего задаваемые вопросы
6. Контактные данные Информация о том, где искать контактные данные производителя / сервисного центра Friedrich WY13 в данной стране, если самостоятельно не получится решить проблему.

У вас вопрос, касающийся Friedrich WY13?

Воспользуйтесь формуляром, находящимся ниже

Если с помощью найденной инструкции Вы не решили свою проблему с Friedrich WY13, задайте вопрос, заполнив следующий формуляр. Если у какого то из пользователей была похожая проблема с Friedrich WY13 со всей вероятностью он захочет поделиться методом ее решения.

Перепишите текст с картинки

Комментарии (0)