    246695-YTG-C-0708 FOR DISTRIBUTION USE ONLY - NOT TO BE USED AT POINT OF RETAIL SALE ULTRA HIGH EFFICIENCY SINGLE P ACKAGE AI R CONDITIONERS AND SINGLE P ACKAGE GAS/ELECTRIC UNITS DJ 150 12-1/2 NOMINAL TONS 1 1.35 EER TECHNICAL GUIDE TECHNICAL GUIDE MA GNUM ® DESCRIPTION YORK ® Predator ® Magnum is a convertible single package unit with a common ...

  • York DJ 150 - page 2

    246695-YTG-C-0708 2 Johnson Controls Unitary Products TABLE OF CONTENTS DESCRIPTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 FEATURES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 FACTORY INSTALLED O PTIONS . . . . . . . . . . . . . . . . . . . 5 FIELD INSTALLED ACCESSORIES . . . . . . . ...

  • York DJ 150 - page 3

    246695-YTG-C-0708 Johnson Controls Unitary Produ cts 3 FEA TURES • High Efficiency – High efficiency unit s are rated at 1 1.35 EER. Gas/electric unit s have electronic spark ignition a nd power vented combustion with stea dy state efficiencies of 80%. These efficien cies meet or exceed all legislated min- imum levels and provide low operating ...

  • York DJ 150 - page 4

    246695-YTG-C-0708 4 Johnson Controls Unitary Products • Environmentally A ware – For improved Indoor Air Quality , foil faced insulation is used e xclusively through- out the units. • Balanced Heating – The Predator ® Magnum offers “Ultimate Heating Comfort” wi th a balance be tween 1 st and 2 nd stage gas heating. The first stage of a ...

  • York DJ 150 - page 5

    246695-YTG-C-0708 Johnson Controls Unitary Produ cts 5 F ACTOR Y INST ALLED OPTIONS YORK ® offers several equipment options factory installed, for the Predator ® Magnum li ne. • Optional F actory Inst alled Economizers - Predator units offer a variety of optiona l factory installed econo- mizers with low leak dampers. The outdoor air enthalpy s ...

  • York DJ 150 - page 6

    246695-YTG-C-0708 6 Johnson Controls Unitary Products • Phase Monitors - Designed to prevent unit damage. The phase monitor wi ll shut the unit down in an out-of phase condition. (St andard on unit s with Scroll Com- pressors.) • Coil Guard - Customers can purchase a coil guard kit to protect the condenser coil from damage. Additionally , this ...

  • York DJ 150 - page 7

    246695-YTG-C-0708 Johnson Controls Unitary Produ cts 7 ventilation. With single enthal py inpu t, the economizer control monitors outdoor air . The dual enthalpy kit pro- vides a second input used to monito r the return air. With a dual input kit installed, the economizer control com- pares the values of the two enthalpy or temperature inputs and p ...

  • York DJ 150 - page 8

    246695-YTG-C-0708 8 Johnson Controls Unitary Products T ABLE 1: ACCESSORIES Part Number Description Weight 1RC0470 Roof Curb, 8" Height - 1RC0471 Roof Curb, 14" Height - 1RC0472 Roof Curb, Transition (7.5 T through 12.5 T) - 1BD0408 Burglar Bars, Downflow - 2TP04521825 Electric Heat 18kW 230V - 2TP04522425 Electric Heat 24kW 230V - 2TP045 ...

  • York DJ 150 - page 9

    246695-YTG-C-0708 Johnson Controls Unitary Produ cts 9 NOMENCLA TURE D J 150 N15 A 2 A AA 4 0 1 2 4 A D = A/C, Single Pkg., R-22 Product Category A = Std. Motor Airflow B = Std. Motor/Econo./Barometric Relief (Downflow Only) C = Std. Motor/Econo./Power Exhaust ( Downflow Only) D = Std. Motor/Motorized Damper (Downflow Only) E = Std. Motor/Horizonta ...

  • York DJ 150 - page 10

    246695-YTG-C-0708 10 Johnson Controls Unitary Products T ABLE 2: PHYSICAL DA T A Component Model DJ 150 (12-1/2 ) Evaporator Blower Blower , Centrifugal (Dia. X Wd. in.) 15 x 15 Motor , S tandard (HP) 3 Motor , Optional (HP) 5 Evaporator Coil Rows 4 Fins per Inch 15 Height (in.) 40 Face Area (ft. 2 each ) 13.2 Condenser Fan (4 per Unit) Propeller D ...

  • York DJ 150 - page 11

    246695-YTG-C-0708 Johnson Controls Unitary Produ cts 11 T ABL E 5: DJ 150 (1 2 1/ 2 T ON) COOLING CAP ACITY Air On Evap. Coil T emperature of A ir on Condenser Coil 85°F T emperature of Air on Condenser Coil 95°F CFM WB (°F) To t . Cap. 1 (MBH) To t . Input 2 (kW) Sensible Capacity (MBH) 1 Return Dry Bulb (°F) To t . Cap. 1 (MBH) To t . Input 2 ...

  • York DJ 150 - page 12

    246695-YTG-C-0708 12 Johnson Controls Unitary Products NOTE: Electric heaters are rated at nominal vol tage. Use this table to determine the electric heat capacity for heaters supplied at lower voltages. NOTES FOR T ABLES 9 AND T ABLE 10: • Blower performance includes dry coil and 2” throwa way filters. • Blower performance for gas h eat incl ...

  • York DJ 150 - page 13

    246695-YTG-C-0708 Johnson Controls Unitary Produ cts 13 T ABLE 9: BLOWER PERFOR MANCE 12-1/2 TON SIDE DUCT CFM External Static Pressure 0.2 0.4 0.6 0.8 1. 0 1.2 1.4 1. 6 1.8 2.0 RPM BHP W atts RPM BHP Watts RPM BHP Watt s RPM B HP Watt s RPM BH P Watt s RPM BHP W atts RPM BHP W atts RPM BHP Watts RPM BHP Watts RPM BHP Watts 3700 -- -- - --- ---- -- ...

  • York DJ 150 - page 14

    246695-YTG-C-0708 14 Johnson Controls Unitary Products T ABLE 10: BLOW ER PERFORMANCE 12-1/2 TON DOWNSHOT CFM External S tatic Pressure 0.2 0.4 0.6 0.8 1.0 1.2 1.4 1.6 1.8 2.0 RPM BHP Watts R PM BHP Watts RPM BHP Watt s RPM BHP Watts RPM BHP Watt s RPM BHP Watts RPM BHP Watt s RPM BHP Watts RPM BHP W atts RPM BHP Watts 3700 ---- ---- ---- ---- ---- ...

  • York DJ 150 - page 15

    246695-YTG-C-0708 Johnson Controls Unitary Produ cts 15 T ABLE 1 1: ADDITIONAL STATIC RESIST ANCE CFM Cooling Onl y 1 Economizer 2 3 Electric Heat KW 2 18 24 36 54 3700 0.20 0.04 0.18 0.21 0.22 0.26 3900 0.23 0.04 0.20 0.23 0.24 0.28 4100 0.25 0.04 0.22 0.25 0.26 0.31 4300 0.28 0.05 0.24 0.28 0.29 0.34 4500 0.30 0.05 0.26 0.30 0.31 0.37 4700 0.33 0 ...

  • York DJ 150 - page 16

    246695-YTG-C-0708 16 Johnson Controls Unitary Products FIGURE 2 - UNIT 4 POINT LOAD T ABLE 15: 4 POINT LOAD WEIGHT Model Location (lbs .) ABCD DJ150 282 359 468 371 FIGURE 3 - UNIT CENTER OF GRAVITY A B D C LEFT FRONT 60" 25-½" LEFT FRONT FIGURE 4 - UNIT WITH 6 POINT LOAD T ABLE 16: 6 POINT LOAD WEIGHT Model Locations (lbs.) ABCDE F DJ15 ...

  • York DJ 150 - page 17

    246695-YTG-C-0708 Johnson Controls Unitary Produ cts 17 FIGURE 5 - UNIT DIMENSIONS 11-1/2 89 27 59 50-3/4 30-11/32 4-1/4 6-3/16 17-3/1 6 24-3/16 30-3/16 119-7/16 Convenience Outlet Convenience Outlet Power Entry 7/8 For Gas Pipe Entry see DETAIL A For Baserail Dimensions see DETAIL B FRONT LEFT Power Entry 2-1/2 Control Entry 7/8 For Drain Dimensio ...

  • York DJ 150 - page 18

    246695-YTG-C-0708 18 Johnson Controls Unitary Products FIGURE 6 - PREDATOR ® MAGNUM ROOF CURB DIMENSIONS 8 o r 1 4 5 0 - 1 / 2 3 0 2 0 2 0 8 0 - 5 / 8 6 2 T Y P . I N S U L A T E D D E C K U N D E R C O M P R E S S O R S E C T I O N I N S U L A T E D D E C K U N D E R C O N D E N S E R S E C T I O N F R O N T R I G H T S U P P L Y R E T U R N FIGU ...

  • York DJ 150 - page 19

    246695-YTG-C-0708 Johnson Controls Unitary Produ cts 19 FIGURE 8 - BOTTOM DUC T OPENINGS (FROM ABO VE) Return Air Supply Air 32-11/16 6-13/16 6-13/16 6-13/16 21-3/16 19-3/16 17-3/16 7-1/8 14-23/32 16-3/8 18-1/16 19-5/8 63-1/2 27-1/2 18 24 21 12-5/16 LEFT FRONT Bottom Condensate Drain Bottom Power, Control and Convenience Outlet Wiring Entries Botto ...

  • York DJ 150 - page 20

    246695-YTG-C-0708 20 Johnson Controls Unitary Products FIGURE 1 1 - FACTORY INSTALLED DOWNFLOW ECONOMIZER FIGURE 10 - D OWNFLOW ECONOMIZER HOOD DETAIL T ABLE 19: ECON OMIZER USAGE Application Description Model Bottom Return Downflow economizer with barometric relief 2EE04705424 Side Return Horizontal economizer without barometric relief 2EE04705524 ...

  • York DJ 150 - page 21

    246695-YTG-C-0708 Johnson Controls Unitary Produ cts 21 FIGURE 12 - FIELD INST ALLED DOWNFLOW ECONOMIZER W/POWER EXHAUST FIGURE 13 - FIELD INST ALLED HORIZO NT AL ECONOMIZER W/POWER EXHAUST 2EE04705424 Fresh Air Hood 2EE04705424 Fresh Air Damper 2EE04705424 Return Air Damper 2PE047032XX Power Exhaust 2EE04705424 Barometric Relief Damper 2EE04705424 ...

  • York DJ 150 - page 22

    246695-YTG-C-0708 22 Johnson Controls Unitary Products FIGURE 14 - SLAB ECONOMIZER DOWNFLOW W/POWER EXHAUST FIGURE 15 - SLAB ECONOMIZER END RETURN W/POWER E XHAUST 2EE04705X24 Slab Economizer 2PE047032XX Power Exhaust 1EH0409 Barometric Relief Damper 1EH0409 Barometric Relief Hood 1EH0409 Fresh Air Hood 2EE04705X24 Slab Economizer 1EH0409 Barometri ...

  • York DJ 150 - page 23

    246695-YTG-C-0708 Johnson Controls Unitary Produ cts 23 FIGURE 16 - CO OLING UNIT WITH GA S HEAT WIRING 230 V . DIAGRAM ...

  • York DJ 150 - page 24

    246695-YTG-C-0708 24 Johnson Controls Unitary Products FIGURE 17 - CO OLING UNIT W/WO EL ECTRIC HEAT WIRING DIAGRAM ...

  • York DJ 150 - page 25

    246695-YTG-C-0708 Johnson Controls Unitary Produ cts 25 FIGURE 18 - CO OLING UNIT WITH GAS HEAT WIRING 460, 575 & 50 HZ DIAGR AM ...

  • York DJ 150 - page 26

    246695-YTG-C-0708 26 Johnson Controls Unitary Products MECHANICAL SPECIFICA TIONS SINGLE P ACKAGE AIR COOL ED GAS/ELECTRIC UN ITS FO R 12.5 NOMINAL T ONS PREDA TOR ® MAGNUM - DJ 150 1 1.35 EER GENERAL Units shall be manufactured by Y ork International Unitary Products Group in an ISO 9001 certified facility . YORK® Predator ® Magnum units are co ...

  • York DJ 150 - page 27

    246695-YTG-C-0708 Johnson Controls Unitary Produ cts 27 Refrigerant Circuit and Refriger ant Safety Components shall include : a. Independent fixed-orifice or thermally ope rate d expan- sion devices. b. Solid core filter drier/stra iner to eliminate any moi sture or foreign matter . c. Accessible servic e gage co nnections on both suction and disc ...

  • York DJ 150 - page 28

    Subject to change without notice. Pr inted in U.S.A. 246695-YTG-C-0708 Copyright © 2008 b y Johnson Controls, Inc. All righ ts reserved. Supersedes: 246695-YTG-B-0606 Johnson Contro ls Unitary Products 5005 York Drive Norman, OK 73069 space during normal operation. During economizer oper- ation, a mixed-air temperatur e control shal l modulate the ...

Производитель York Категория Air Conditioner

Документы, которые мы получаем от производителя устройства York DJ 150 мы можем разделить на несколько групп. Это в частности:
- технические чертежи York
- инструкции обслуживания DJ 150
- паспорта изделия York
- информационные брошюры
- энергетические этикетки York DJ 150
Все из них важны, однако самую важную информацию с точки зрения пользователя мы найдем в инструкции обслуживания York DJ 150.

Группа документов, определяемая как инструкции обслуживания, делится также на более подробные типы, такие как: Инструкции монтажа York DJ 150, инструкции обслуживания, короткие инструкции или инструкции пользователя York DJ 150. В зависимости от потребностей, Вам необходимо поискать требуемый документ. На нашем сайте Вы можете просмотреть самую популярную инструкцию использования изделия York DJ 150.

Похожие инструкции обслуживания

Полная инструкция обслуживания устройства York DJ 150, как должна выглядеть?
Инструкция обслуживания, определяемая также как пособие пользователя, или просто "руководство" - это технический документ, цель которого заключается в использовании York DJ 150 пользователями. Инструкции пишет, как правило технический писатель, языком, доступным для всех пользователей York DJ 150.

Полная инструкция обслуживания York, должна заключать несколько основных элементов. Часть из них менее важная, как например: обложка / титульный лист или авторские страницы. Однако остальная часть, должна дать нам важную с точки зрения пользователя информацию.

1. Вступление и рекомендации, как пользоваться инструкцией York DJ 150 - В начале каждой инструкции, необходимо найти указания, как пользоваться данным пособием. Здесь должна находится информация, касающаяся местонахождения содержания York DJ 150, FAQ и самых распространенных проблем - то есть мест, которые чаще всего ищут пользователи в каждой инструкции обслуживания
2. Содержание - индекс всех советов, касающихся York DJ 150, которое найдем в данном документе
3. Советы по использованию основных функций устройства York DJ 150 - которые должны облегчить нам первые шаги во время использования York DJ 150
4. Troubleshooting - систематизированный ряд действия, который поможет нам диагностировать а в дальнейшем очередность решения важнейших проблем York DJ 150
5. FAQ - чаще всего задаваемые вопросы
6. Контактные данные Информация о том, где искать контактные данные производителя / сервисного центра York DJ 150 в данной стране, если самостоятельно не получится решить проблему.

У вас вопрос, касающийся York DJ 150?

Воспользуйтесь формуляром, находящимся ниже

Если с помощью найденной инструкции Вы не решили свою проблему с York DJ 150, задайте вопрос, заполнив следующий формуляр. Если у какого то из пользователей была похожая проблема с York DJ 150 со всей вероятностью он захочет поделиться методом ее решения.

Перепишите текст с картинки

Комментарии (0)