Инструкция обслуживания Vermont Casting VL24

20 страниц 0.42 mb
Скачать

Перейти на страницу of 20

Summary
  • Vermont Casting VL24 - page 1

    Installation and Operation Instructions for V ent-Free Gas Log Sets* Models: VL18, VL21 and VL24 (Natural Gas) VL18LP , VL21LP and VL24LP (Propane) CERTIFIED D E S I G N C E R T I F I E D 20002538 1/07 Rev . 8 *These logsets are not for exterior use. W A R N I N G If the information in this manual is not followed exactly , a fire or explosion may ...

  • Vermont Casting VL24 - page 2

    2 20002538 The Logsets have been designed and tested to operate safely when installed according to the installation instructions con- tained in this manual. Read all instructions before starting the installation. In the Commonwealth of Massachusetts, all gas fitting and installation of this heater shall only be done by a licensed gas fitter or li ...

  • Vermont Casting VL24 - page 3

    3 20002538 Installation Requirements The fireplace must meet the minimum dimensions listed below . (Fig. 1) Do not install the logset if the fireplace does not meet these minimums. Pressure T est Points Copreci V alve: 1/8” N.P .T . plugged tapping is provided on the outlet side of the gas control for a test manifold pressure. SIT V alve: Inlet ...

  • Vermont Casting VL24 - page 4

    4 20002538 Planning Planning the installation is an important first step. It will save time and money later in the actual installation. In planning the installation, consider: • Where the heater will be located. • All components needed to complete the installation. • DO NOT use this heater in bedrooms, bathrooms, mobile homes or in recreatio ...

  • Vermont Casting VL24 - page 5

    5 20002538 Installation Requirements WARNING This heater must have fresh air for proper opera- tion. If it does not, poor fuel combustion could result. Read the following instructions to ensure proper fresh air supply for this and other fuel- burning appliances in your home. Modern construction standards have resulted in homes that are highly energ ...

  • Vermont Casting VL24 - page 6

    6 20002538 WARNING This heater shall not be installed in a confined space or unusually tight construction unless provisions are made for adequate combustion and ventilation air . WARNING If the area in which the heater may be operated is smaller than that defined as an unconfined space, or if the building is of unusually tight construction, prov ...

  • Vermont Casting VL24 - page 7

    7 20002538 W ARNING: Do not allow fans to blow directly into the fireplace. Avoid any drafts that alter burner flame patterns. W ARNING: Do not use a blower insert, heat ex - changer insert or other accessory not approved for use with this gas logset. Do not burn solid fuels in a fireplace where an unvented gas room heater or logset is installed ...

  • Vermont Casting VL24 - page 8

    8 20002538 Damper Stop Installation When installing a decorative gas appliance in a fire- place, some local codes require a damper stop be added so the damper will not close completely . The CFM Corporation damper stop is designed so the damper can be locked in the closed position, and still allow a vent for the pilot gasses. This damper stop is d ...

  • Vermont Casting VL24 - page 9

    9 20002538 Burner Assembly Location Centrally locate the unit in the fireplace, far enough back into the firebox to accomplish adequate draft (if use as a vented appliance is planned). Ensure the front grate feet sit inside the front edge of the fireplace a minimum of 3 ¹⁄₄ ”. (Fig. 6b) Gas Line Connection Check the gas type. Use only the ...

  • Vermont Casting VL24 - page 10

    10 20002538 Check the inlet pressure to the appliance, to ensure that it is as shown in the table on page 3. The minimum is for the purpose of input adjustment. The pressure is controlled by the regulator and should be checked at the pressure test point located in the control valve body . Access to the pressure test point is obtained by removing al ...

  • Vermont Casting VL24 - page 11

    1 1 20002538 LG100 VL18 logset  3/26/99  changed burner 4/3/00 djt Locator Pins Locator Pin Grate LG100 Locator Pin Fig. 7 VL18 log placement. LG102 VL21 logset  3/31/99  modified burner/grate 4/3/00 djt Locator Pins Grate LG102 Locator Pin Locator Pin Fig. 8 VL21 log placement. LG104 VL24 logset  4/1/99  modified burner ...

  • Vermont Casting VL24 - page 12

    12 20002538 3. Open control access panel. 4. Push in gas control knob slightly and turn clock- wise to “OFF”. Do not force. 5. Close control access panel. 1. STOP! Read the safety information above. 2. Turn of f all electrical power to the fireplace. 3. For MN/MP/TN/TP appliances ONL Y , go on to Step 4. For RN/RP appliances turn the On/Of f s ...

  • Vermont Casting VL24 - page 13

    13 20002538 When Used as a Heating Appliance 1. This appliance is equipped with a modulating valve which provides variable control of heat output, from approximately 15,000 or 18,000 BTU/hr at the full counterclockwise LOW position, to 24,000, 32,000 or 35,000 BTU/hr at the HIGH position, depending on your appliance. See page 3 for output of your a ...

  • Vermont Casting VL24 - page 14

    14 20002538 LF103� VL21 flames � 3/31/99 � changed valve 4/14/00 djt HI OFF PILO T LO LF101� VL18 flames � 3/29/99 � changed valve 4/13/00 djt HI OF F PILO T LO 7” - 9” Approx. 7” - 9” Approx. 6” - 8” Ap - prox. LG101 LG103 LG105 VL24 VL21 VL18 LF105� VL24 flames � 4/1/99 � changed valve 4/14/00 djt HI OF F PILO T LO 7 ...

  • Vermont Casting VL24 - page 15

    15 20002538 T roubleshooting With proper installation and maintenance, your new Gas Appliance should provide years of trouble-free ser- vice. If you do experience a problem, this guide will assist a CERTIFIED SERVICE PERSON in the diag- nosis of problems and the corrective action to be taken. Symptom Possible Causes Corrective Action Pilot will not ...

  • Vermont Casting VL24 - page 16

    16 20002538 1 a b c d HI OFF PILO T LO 2 3 4 5 6a,b 10a,b 7 8 9 1 1a,b 12a,b 13a,b 15a,b 2538 VL18,21,24,30 replacement parts 4/4/00 djt 14 16a,b 17 CFM Corporation reserves the right to make changes in design, materials, specifications, prices and discontinue colors and products at any time, without notice. 2538 VL18/21/24 Standard V ent Free Gas ...

  • Vermont Casting VL24 - page 17

    17 20002538 Contact the factory for questions concerning prices and policies covering replacement parts. Parts will be shipped at prevailing prices. Normally , all parts can be ordered through your CFM Corporation distributor or dealer . When ordering replacement parts, always give the fol- lowing information: •The model number of the appliance. ...

  • Vermont Casting VL24 - page 18

    18 20002538 Model No. Accessories The following accessories are available from your CFM Corporation dealer . Should you need additional information beyond what your dealer can furnish, contact CFM Corporation, 410 Admiral Blvd. Mississauga, Ontario, Canada L5T 2N6, Attention: T echnical Service. Accessory Description Required to protect wall above ...

  • Vermont Casting VL24 - page 19

    19 20002538 MERCHANT ABILITY OR FITNESS FOR A P ARTICULAR PURPOSE), ALL OF WHICH ARE HEREBY EXPRESSL Y INCLUDED. IN NO EVENT SHALL ANY IMPLIED W AR - RANTY PRESCRIBED BY LA W (NOTWITHST ANDING THE FOREGOING EXPRESS EXCLUSION) REMAIN IN EF- FECT AFTER EXPIRA TIONS OF THE W ARRANTIES SET FORTH IN P ARAGRAPHS A AND B. A. Gas Appliances, electrical and ...

  • Vermont Casting VL24 - page 20

    © CFM Corporation 410 Admiral Blvd. • Mississauga, Ontario, Canada L5T 2N6 800-668-5323 • www .cfmcorp.com CFM Corporation ...

Производитель Vermont Casting Категория Indoor Fireplace

Документы, которые мы получаем от производителя устройства Vermont Casting VL24 мы можем разделить на несколько групп. Это в частности:
- технические чертежи Vermont Casting
- инструкции обслуживания VL24
- паспорта изделия Vermont Casting
- информационные брошюры
- энергетические этикетки Vermont Casting VL24
Все из них важны, однако самую важную информацию с точки зрения пользователя мы найдем в инструкции обслуживания Vermont Casting VL24.

Группа документов, определяемая как инструкции обслуживания, делится также на более подробные типы, такие как: Инструкции монтажа Vermont Casting VL24, инструкции обслуживания, короткие инструкции или инструкции пользователя Vermont Casting VL24. В зависимости от потребностей, Вам необходимо поискать требуемый документ. На нашем сайте Вы можете просмотреть самую популярную инструкцию использования изделия Vermont Casting VL24.

Похожие инструкции обслуживания

Полная инструкция обслуживания устройства Vermont Casting VL24, как должна выглядеть?
Инструкция обслуживания, определяемая также как пособие пользователя, или просто "руководство" - это технический документ, цель которого заключается в использовании Vermont Casting VL24 пользователями. Инструкции пишет, как правило технический писатель, языком, доступным для всех пользователей Vermont Casting VL24.

Полная инструкция обслуживания Vermont Casting, должна заключать несколько основных элементов. Часть из них менее важная, как например: обложка / титульный лист или авторские страницы. Однако остальная часть, должна дать нам важную с точки зрения пользователя информацию.

1. Вступление и рекомендации, как пользоваться инструкцией Vermont Casting VL24 - В начале каждой инструкции, необходимо найти указания, как пользоваться данным пособием. Здесь должна находится информация, касающаяся местонахождения содержания Vermont Casting VL24, FAQ и самых распространенных проблем - то есть мест, которые чаще всего ищут пользователи в каждой инструкции обслуживания
2. Содержание - индекс всех советов, касающихся Vermont Casting VL24, которое найдем в данном документе
3. Советы по использованию основных функций устройства Vermont Casting VL24 - которые должны облегчить нам первые шаги во время использования Vermont Casting VL24
4. Troubleshooting - систематизированный ряд действия, который поможет нам диагностировать а в дальнейшем очередность решения важнейших проблем Vermont Casting VL24
5. FAQ - чаще всего задаваемые вопросы
6. Контактные данные Информация о том, где искать контактные данные производителя / сервисного центра Vermont Casting VL24 в данной стране, если самостоятельно не получится решить проблему.

У вас вопрос, касающийся Vermont Casting VL24?

Воспользуйтесь формуляром, находящимся ниже

Если с помощью найденной инструкции Вы не решили свою проблему с Vermont Casting VL24, задайте вопрос, заполнив следующий формуляр. Если у какого то из пользователей была похожая проблема с Vermont Casting VL24 со всей вероятностью он захочет поделиться методом ее решения.

Перепишите текст с картинки

Комментарии (0)