    UNVENTED (VENT -FREE) NA TURAL GAS LOG HEA TER ALSO DESIGN-CERTIFIED AS A VENTED DECORATIVE APPLIANCE OWNER’S OPERA TION AND INST ALLA TION MANUAL Save this manual for future reference. WARNING: If the information in this manual is not followed exactly, a fire or explosion may result causing property damage, personal injury, or loss of life. — ...

  • Desa VFN18MV - page 2

    2 105070 FIREPLACE MANUF ACTURERS INCORPORA TED UNVENTED NA TURAL GAS LOG HEA TER 1. This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not convertible for use with other gases. 2. If you smell gas • shut off g as supply • do not try to light any appliance • do not touch any electrical switch; ...

  • Desa VFN18MV - page 3

    3 105070 OWNERS MANUAL PRODUCT IDENTIFICA TION Figure 1 - Ember Master Left Front Log Control Knob Rear Log Base Assembly Front Burner Piezo Ignitor Rear Burner Crossover Log Bottom Middle Log Install and use heater with care. Follow all local codes. In the absence of local codes, use the latest edition of The National Fuel Gas Code, ANS Z223.1 , a ...

  • Desa VFN18MV - page 4

    4 105070 FIREPLACE MANUF ACTURERS INCORPORA TED UNVENTED NA TURAL GAS LOG HEA TER Confined and Unconfined Space The National Fuel Gas Code, ANS Z223.1 defines a confined space as a space whose volume is less than 50 cubic feet per 1,000 Btu per hour (4.8 m 3 per kw) of the aggre- gate input rating of all appliances installed in that space and an un ...

  • Desa VFN18MV - page 5

    5 105070 OWNERS MANUAL DETERMINING FRESH-AIR FLOW FOR HEATER LOCATION Determining if You Have a Confined or Unconfined Space Use this work sheet to determine if you have a confined or unconfined space. Space: Includes the room in which you will install heater plus any adjoining rooms with doorless passageways or ventilation grills between the rooms ...

  • Desa VFN18MV - page 6

    6 105070 FIREPLACE MANUF ACTURERS INCORPORA TED UNVENTED NA TURAL GAS LOG HEA TER AIR FOR COMBUSTION AND VENTILA TION Continued VENTILATION AIR Ventilation Air From Inside Building This fresh air would come from an adjoining unconfined space. When ventilating to an adjoining unconfined space, you must pro- vide two permanent openings: one within 12 ...

  • Desa VFN18MV - page 7

    7 105070 OWNERS MANUAL MINIMUM FIREPLACE CLEARANCE TO COMBUSTIBLE MATERIALS Log Size 18", 24", 30" Side Wall 16" Ceiling 42" Floor 5" INSTALLATION AND CLEARANCES (Vent-Free Operation Only) WARNING: Maintain the mini- mum clearances. If you can, pro- vide greater clearances from floor, ceiling, and adjoining wall. LOG S ...

  • Desa VFN18MV - page 8

    8 105070 FIREPLACE MANUF ACTURERS INCORPORA TED UNVENTED NA TURAL GAS LOG HEA TER Noncombustible Requirements for Material Distance (A) Safe Installation 12" or more Noncombustible material OK. Between 8" and 12" 24" and 30" Models: Install fireplace hood accessory (HDABK or HDABR, see Accessories , page 22). 18" Model ...

  • Desa VFN18MV - page 9

    9 105070 OWNERS MANUAL 14" Min. Combustible Material Non-Combustible Material Figure 8 - Minimum Fireplace Clearances If Installed at Floor Level Hearth 5" Min. Combustible Material Figure 9 - Minimum Fireplace Clearances Above Combustible Flooring FLOOR CLEARANCES A. If installing appliance on the floor level, you must maintain the minim ...

  • Desa VFN18MV - page 10

    10 105070 FIREPLACE MANUF ACTURERS INCORPORA TED UNVENTED NA TURAL GAS LOG HEA TER INST ALLA TION Continued INSTALLING HEATER BASE ASSEMBLY WARNING: You must secure this heater to fireplace floor. If not, heater will move when you adjust controls. Moving heater may cause a gas leak. WARNING: If installing in a sunken fireplace, special care is need ...

  • Desa VFN18MV - page 11

    11 105070 OWNERS MANUAL 10. Attach mounting brackets to fireplace floor using masonry screws (in hard- ware package). 1 1 . Reattach heater base to mounting brackets. T ighten nuts firmly . Heater Gas Regulator Flexible Gas Hose (if allowed by local codes) Figure 11 - Attaching Flexible Gas Hose to Heater Gas Regulator Figure 12 - Attaching Heater ...

  • Desa VFN18MV - page 12

    12 105070 FIREPLACE MANUF ACTURERS INCORPORA TED UNVENTED NA TURAL GAS LOG HEA TER WARNING: Never use an open flame to check for a leak. Apply a mixture of liquid soap and water to all joints. Bubbles forming show a leak. Correct all leaks at once. WARNING: Test all gas pip- ing and connections for leaks after installing or servicing. Cor- rect all ...

  • Desa VFN18MV - page 13

    13 105070 OWNERS MANUAL INST ALLA TION Continued WARNING: Failure to posi- tion the parts in accordance with these diagrams or failure to use only parts specifically approved with this heater may result in prop- erty damage or personal injury. INSTALLING LOGS Each log is marked with a number. These numbers will help you identify the log when instal ...

  • Desa VFN18MV - page 14

    14 105070 FIREPLACE MANUF ACTURERS INCORPORA TED UNVENTED NA TURAL GAS LOG HEA TER Figure 22 - Pilot Thermocouple Ignitor Electrode Pilot Burner 4. W ait fi ve (5) minutes to clear out any gas. Then smell f or gas, including near the floor . If you smell gas, STOP! F ollow “B” in the safety in- formation, column 1. If y ou don’t smell gas, go ...

  • Desa VFN18MV - page 15

    15 105070 OWNERS MANUAL TO TURN OFF GAS TO APPLIANCE WARNING: Do not operate heater between locked positions. CAUTION: Do not try to ad- just heating levels by using the equipment shutoff valve. The variable control valve can be set to any heat setting and flame height desired, by simply turning the control knob until that setting is attained. Even ...

  • Desa VFN18MV - page 16

    16 105070 FIREPLACE MANUF ACTURERS INCORPORA TED UNVENTED NA TURAL GAS LOG HEA TER SPECIFICA TIONS 18" Variable 24" Variable 30" Variable Manually- Manually- Manually- Controlled Controlled Controlled Btu (Variable) 16,000/26,000 20,000/33,000 21,500/36,000 Type Gas Natural Gas Only Natural Gas Only Natural Gas Only Ignition Piezo Pi ...

  • Desa VFN18MV - page 17

    17 105070 OWNERS MANUAL TROUBLESHOOTING Note: All troubleshooting items are listed in order of operation. WARNING: Turn off and un- plug heater and let cool before servicing. Only a qualified ser- vice person should service and repair heater. CAUTION: Never use a wire, needle, or similar object to clean ODS/pilot. This can damage ODS/ pilot unit. P ...

  • Desa VFN18MV - page 18

    18 105070 FIREPLACE MANUF ACTURERS INCORPORA TED UNVENTED NA TURAL GAS LOG HEA TER OBSERVED PROBLEM One or both burners do not light after ODS/ pilot is lit Delayed ignition of one or both burners Burner backfiring during combustion Yellow flame in front burner during burner combustion Slight smoke or odor during initial operation Heater produces a ...

  • Desa VFN18MV - page 19

    19 105070 OWNERS MANUAL TROUBLESHOOTING Continued WARNING: If you smell gas • Shut off gas supply. • Do not try to light any appliance. • Do not touch any electrical switch; do not use any phone in your building. • Immediately call your gas supplier from a neighbor ’ s phone. Follow the gas supplier ’ s instructions. • If you cannot r ...

  • Desa VFN18MV - page 20

    20 105070 FIREPLACE MANUF ACTURERS INCORPORA TED UNVENTED NA TURAL GAS LOG HEA TER ILLUSTRA TED PA R T S BREAKDOWN VARIABLE MANUALLY- CONTROLLED MODELS VFN18MV VFN24MV VFN30MV 17 19 18 25 24 20 20 26 27 28 6 7 27 27 24 9 8 10 11 12 14 21 22 26-1 26-2 23 6-1 6-2 13 15 16 4 5 3 2 1R 1L ...

  • Desa VFN18MV - page 21

    21 105070 OWNERS MANUAL P ARTS LIST VARIABLE MANUALLY- CONTROLLED MODELS VFN18MV VFN24MV VFN30MV This list contains replaceable parts used in your heater. When ordering parts, follow the instructions listed under Replacement Parts on page 22 of this manual. KEY PART NUMBER FOR NO. VFN18MV VFN24MV VFN30MV DESCRIPTION QTY. 1L 105241-01 105241-02 1059 ...

  • Desa VFN18MV - page 22

    22 105070 FIREPLACE MANUF ACTURERS INCORPORA TED UNVENTED NA TURAL GAS LOG HEA TER Note: Use only original replacement parts. This will protect your warranty coverage for parts replaced under warranty. PARTS UNDER WARRANTY Contact authorized dealers of this product. If they can’t supply original replacement part(s), call Fireplace Manfuacturers I ...

  • Desa VFN18MV - page 23

    23 105070 OWNERS MANUAL NOTES _______________________________________________________________________________________________ _______________________________________________________________________________________________ _______________________________________________________________________________________________ ________________________________ ...

  • Desa VFN18MV - page 24

    LIMITED WARRANTY VENT-FREE NATURAL GAS LOG HEATERS DESA International warrants this product to be free from defects in materials and components for one (1) year from the date of first purchase, provided that the product has been properly installed, operated and maintained in accordance with all applicable instructions. To make a claim under this wa ...

Производитель Desa Категория Electric Heater

Документы, которые мы получаем от производителя устройства Desa VFN18MV мы можем разделить на несколько групп. Это в частности:
- технические чертежи Desa
- инструкции обслуживания VFN18MV
- паспорта изделия Desa
- информационные брошюры
- энергетические этикетки Desa VFN18MV
Все из них важны, однако самую важную информацию с точки зрения пользователя мы найдем в инструкции обслуживания Desa VFN18MV.

Группа документов, определяемая как инструкции обслуживания, делится также на более подробные типы, такие как: Инструкции монтажа Desa VFN18MV, инструкции обслуживания, короткие инструкции или инструкции пользователя Desa VFN18MV. В зависимости от потребностей, Вам необходимо поискать требуемый документ. На нашем сайте Вы можете просмотреть самую популярную инструкцию использования изделия Desa VFN18MV.

Похожие инструкции обслуживания

Полная инструкция обслуживания устройства Desa VFN18MV, как должна выглядеть?
Инструкция обслуживания, определяемая также как пособие пользователя, или просто "руководство" - это технический документ, цель которого заключается в использовании Desa VFN18MV пользователями. Инструкции пишет, как правило технический писатель, языком, доступным для всех пользователей Desa VFN18MV.

Полная инструкция обслуживания Desa, должна заключать несколько основных элементов. Часть из них менее важная, как например: обложка / титульный лист или авторские страницы. Однако остальная часть, должна дать нам важную с точки зрения пользователя информацию.

1. Вступление и рекомендации, как пользоваться инструкцией Desa VFN18MV - В начале каждой инструкции, необходимо найти указания, как пользоваться данным пособием. Здесь должна находится информация, касающаяся местонахождения содержания Desa VFN18MV, FAQ и самых распространенных проблем - то есть мест, которые чаще всего ищут пользователи в каждой инструкции обслуживания
2. Содержание - индекс всех советов, касающихся Desa VFN18MV, которое найдем в данном документе
3. Советы по использованию основных функций устройства Desa VFN18MV - которые должны облегчить нам первые шаги во время использования Desa VFN18MV
4. Troubleshooting - систематизированный ряд действия, который поможет нам диагностировать а в дальнейшем очередность решения важнейших проблем Desa VFN18MV
5. FAQ - чаще всего задаваемые вопросы
6. Контактные данные Информация о том, где искать контактные данные производителя / сервисного центра Desa VFN18MV в данной стране, если самостоятельно не получится решить проблему.

У вас вопрос, касающийся Desa VFN18MV?

Воспользуйтесь формуляром, находящимся ниже

Если с помощью найденной инструкции Вы не решили свою проблему с Desa VFN18MV, задайте вопрос, заполнив следующий формуляр. Если у какого то из пользователей была похожая проблема с Desa VFN18MV со всей вероятностью он захочет поделиться методом ее решения.

Перепишите текст с картинки

Комментарии (0)