  • Ei Electronics Ei 3100RF - page 1

    1 SMOKE ALARM Radio Wireless Interconnect Instruction Leaflet Contains vital information on unit operation and installation. Read and retain carefully . If you are just installing the unit, this leaflet MUST be given to the householder . Model: Ei 3105RF (OPTICAL WITH HUSH) Ei 3100RF (IONISA TION) P/N B15??? Rev 0 ...

  • Ei Electronics Ei 3100RF - page 2

    T able of Contents 1 READ THIS FIRST 2 INTRODUCTION 3 LOCA TING YOUR SMOKE ALARMS 4 POSITIONING YOUR SMOKE ALARM 5 INST ALLING YOUR SMOKE ALARMS 6 HOUSE CODING YOUR ALARMS 7 TESTING AND MAINT AINING YOUR SMOKE ALARMS 8 TROUBLESHOOTING YOUR ALARMS 9 IMPORT ANT SAFEGUARDS 10 SMOKE ALARM & RF LIMIT A TIONS 11 GETTING YOUR SMOKE ALARM SERVICED 12 F ...

  • Ei Electronics Ei 3100RF - page 3

    3 10. If you have any doubt or query about Smoke Alarms con- sult the supplier or your local Fire Brigade. 2. INTRODUCTION Congratulations on purchasing Ei3105RF or Ei3100RF RadioLINK Smoke Alarms. Y ou can easily install these alarms throughout the house in closed rooms, corridors and in the attic for the fastest response to developing fires. Clos ...

  • Ei Electronics Ei 3100RF - page 4

    4 example) you should put your first Smoke Alarm in a corridor or hallway between the sleeping and living areas. Place it as near to the living area as possible, but make sure you can hear it loudly enough to wake you in the bedroom. (for exam- ple, see figure 2). If your bungalow is very large and the corridor or hallway is more than say 20 paces ...

  • Ei Electronics Ei 3100RF - page 5

    3.2 Multi Storey Dwellings If your home has more than one floor , at least one alarm should be fitted on each level (see figure 4). The Ei3105RF/Ei3100RF Wireless Smoke Alarm is ideal in this situation as they are automatically interconnected without wiring. 3.3 Recommended Protection Fire authorities recommend you put individual Smoke Alarms in or ...

  • Ei Electronics Ei 3100RF - page 6

    6 entering the Smoke Alarm. Keep at least 0.30m away from walls and corners (see figure 5). 4.2 W all Mounting When a ceiling position is not possible (for example on a ceil- ing having exposed beams or joists, or built-in radiant heat- ing) put the top edge of your Smoke Alarm between 0.15m and 0.30m below the ceiling. Keep at least 0.30m from cor ...

  • Ei Electronics Ei 3100RF - page 7

    7 It can also block the insect screen mesh and prevent smoke from entering the chamber . • Do not locate in insect infested areas. Small insects getting in to the chamber can cause intermittent alarms. 5. INST ALLING YOUR SMOKE ALARMS (a) Attaching to Ceiling or Wall. OPEN T AB BA TTER Y INST ALLA TION DA TE TEST & HUSH BUTTON SCREW HOLE PUSH ...

  • Ei Electronics Ei 3100RF - page 8

    8 1. Pull cover open at tab. Remove cover from base by sepa- rating at rear snap-in hinges by rotating cover backwards. 2. Place the base on ceiling or wall exactly where you want to mount the unit. With a pencil, mark the location of the screw holes. 3. T aking care to avoid any electrical wiring in the ceiling or wall, drill a hole through the ce ...

  • Ei Electronics Ei 3100RF - page 9

    9 8. The units, as received, will transmit and receive the default RF signal. However , to avoid other neighbouring systems interfering with your alarms, we recommend that you “house code” your alarms. Install all the other alarms similarly . 5.2 If Radio Link is not working It is imperative that all smoke alarms in your system commu- nicate wi ...

  • Ei Electronics Ei 3100RF - page 10

    10 6.1 House Code Procedure Ensure that the battery is connected to all alarms before beginning the house code procedure 1. Pull cover open at tab. Press the house code switch and hold until the amber light comes on and then release. The amber light will then flash rapidly for about 1 second to indi- cate the unit is now in the house code mode (see ...

  • Ei Electronics Ei 3100RF - page 11

    11 7.1 Manually T esting your Smoke Alarm It is recommended that you test your Smoke Alarm at least weekly to be sure the units are working. It will also help you and your family to become familiar with the sound of the alarms. When you press the test button it simulates the effect of smoke during a real fire. So, there is no need to test the Alarm ...

  • Ei Electronics Ei 3100RF - page 12

    12 If there are frequent nuisance/false alarms it may be neces- sary to re-locate the device away from the source of the fumes. If you installed the smoke alarms as received and did not house code them, you may be receiving an alarm signal from a neighbouring system. This can be easy rectified by “house coding” your alarms (see section 6). 1. T ...

  • Ei Electronics Ei 3100RF - page 13

    13 the effects of contamination. However it is impossible to com- pletely eliminate the effect of dust and insect contamination, and therefore, to prolong the life of the Smoke Alarm you must ensure that it is kept clean so that excess dust does not build up. Any insects or cobwebs in the vicinity of the Smoke Alarm should be promptly removed. In c ...

  • Ei Electronics Ei 3100RF - page 14

    14 8.3 The alarms sound but the wireless interconnection does not work There are certain limitations on radio frequency signals (see section 10.2) and so, some alarms may not sound when the test button of a smoke alarm. Then; • Ensure you have held the test button down until the amber light has come on continuously (this could take up to 5 sec- o ...

  • Ei Electronics Ei 3100RF - page 15

    15 clean the Smoke Alarm following instructions in this leaflet. • In the United Kingdom Ionisation Smoke Alarms can be dis- posed of in normal household refuse, but due to the tiny amount of radioactive material contained in the unit, no more than one alarm per dustbin. • In the Republic of Ireland Ionisation smoke alarms should be returned fo ...

  • Ei Electronics Ei 3100RF - page 16

    16 4. Call the Fire Brigade from a neighbour ’ s house or mobile phone. Remember to give your name and address. 5. NEVER re-enter a burning house. 10. SMOKE ALARM & RF LIMIT A TIONS 10.1 Limitations of Smoke Alarms Smoke Alarms have significantly helped to reduce the number of fire fatalities in countries where they are widely installed. Howe ...

  • Ei Electronics Ei 3100RF - page 17

    17 roll up fire ladders and stools without adult help. Make sure they know what to do if the alarm goes off. 10.2 Limitations of Radio Frequency Signals Ei Electronics radio communication systems are very reliable and are tested to high standards. However , due to their low transmitting power and limited range (required by regulatory bodies) there ...

  • Ei Electronics Ei 3100RF - page 18

    18 12. FIVE YEAR GUARANTEE (Limited) Ei Electronics, guarantees this smoke alarm for five years from date of purchase against any defects that are due to faulty materials or workmanship. This guarantee only applies to normal conditions of use and service, and does not include damage resulting from accident, neglect, mis-use, unautho- rized dismantl ...

  • Ei Electronics Ei 3100RF - page 19

    19 14. TECHNICAL SPECIFICA TION Battery: Replaceable 9 V olt Alkaline Duracell (MN1604, Energizer 522 or Eveready 522). Battery Life: Battery can power unit in standby for over a year . Power on Indicator: Red light flashes every 40 seconds. Smoke Sensitivity: Meets or exceeds requirements of BS5446-1: 2000. RF & EMC: Complies with the requirem ...

  • Ei Electronics Ei 3100RF - page 20

    20 RF Visual Indicator: On T ransmission, Amber LED lights continuously for 1.5 to 3.5 seconds while messages are being transmitted. Size of System: A maximum number of 12 units can com- municate together on one system (however the range is like- ly to be the limiting factor in many cases) Communication: All units will communicate together as shipp ...

  • Ei Electronics Ei 3100RF - page 21

    21 ...

  • Ei Electronics Ei 3100RF - page 22

    22 ...

  • Ei Electronics Ei 3100RF - page 23

    23 ...

  • Ei Electronics Ei 3100RF - page 24

    24 ...

Производитель Ei Electronics Категория Smoke Alarm

Документы, которые мы получаем от производителя устройства Ei Electronics Ei 3100RF мы можем разделить на несколько групп. Это в частности:
- технические чертежи Ei Electronics
- инструкции обслуживания Ei 3100RF
- паспорта изделия Ei Electronics
- информационные брошюры
- энергетические этикетки Ei Electronics Ei 3100RF
Все из них важны, однако самую важную информацию с точки зрения пользователя мы найдем в инструкции обслуживания Ei Electronics Ei 3100RF.

Группа документов, определяемая как инструкции обслуживания, делится также на более подробные типы, такие как: Инструкции монтажа Ei Electronics Ei 3100RF, инструкции обслуживания, короткие инструкции или инструкции пользователя Ei Electronics Ei 3100RF. В зависимости от потребностей, Вам необходимо поискать требуемый документ. На нашем сайте Вы можете просмотреть самую популярную инструкцию использования изделия Ei Electronics Ei 3100RF.

Похожие инструкции обслуживания

Полная инструкция обслуживания устройства Ei Electronics Ei 3100RF, как должна выглядеть?
Инструкция обслуживания, определяемая также как пособие пользователя, или просто "руководство" - это технический документ, цель которого заключается в использовании Ei Electronics Ei 3100RF пользователями. Инструкции пишет, как правило технический писатель, языком, доступным для всех пользователей Ei Electronics Ei 3100RF.

Полная инструкция обслуживания Ei Electronics, должна заключать несколько основных элементов. Часть из них менее важная, как например: обложка / титульный лист или авторские страницы. Однако остальная часть, должна дать нам важную с точки зрения пользователя информацию.

1. Вступление и рекомендации, как пользоваться инструкцией Ei Electronics Ei 3100RF - В начале каждой инструкции, необходимо найти указания, как пользоваться данным пособием. Здесь должна находится информация, касающаяся местонахождения содержания Ei Electronics Ei 3100RF, FAQ и самых распространенных проблем - то есть мест, которые чаще всего ищут пользователи в каждой инструкции обслуживания
2. Содержание - индекс всех советов, касающихся Ei Electronics Ei 3100RF, которое найдем в данном документе
3. Советы по использованию основных функций устройства Ei Electronics Ei 3100RF - которые должны облегчить нам первые шаги во время использования Ei Electronics Ei 3100RF
4. Troubleshooting - систематизированный ряд действия, который поможет нам диагностировать а в дальнейшем очередность решения важнейших проблем Ei Electronics Ei 3100RF
5. FAQ - чаще всего задаваемые вопросы
6. Контактные данные Информация о том, где искать контактные данные производителя / сервисного центра Ei Electronics Ei 3100RF в данной стране, если самостоятельно не получится решить проблему.

У вас вопрос, касающийся Ei Electronics Ei 3100RF?

Воспользуйтесь формуляром, находящимся ниже

Если с помощью найденной инструкции Вы не решили свою проблему с Ei Electronics Ei 3100RF, задайте вопрос, заполнив следующий формуляр. Если у какого то из пользователей была похожая проблема с Ei Electronics Ei 3100RF со всей вероятностью он захочет поделиться методом ее решения.

Перепишите текст с картинки

Комментарии (0)