    GENERAL YORK Model D1NA and D2NA units are cooling/heating air con - ditioners designed for outdoor installation. Only gas piping, elec - tric power and duct connections are required at the point of installation. The gas-fired heaters have hot surface to pilot ignition. The tu - bular heat exchangers are aluminized steel. This appliance is not to b ...

  • York D2NA060 - page 2

    035-18265-001-A-0202 2 Unitary Products Group T ABLE OF CONTENTS TROUBLESHOOTING T roubleshooting Chart ..................................................... 15 T ABLES No. Description Page 1 Units Application Data ................................. 3 2 Natural Gas Application Data ...................... 5 3 LP Gas Application Data ................. ...

  • York D2NA060 - page 3

    Not suitable for use with conventional venting systems. LIMIT ATIONS These units must be installed in accordance with the following national and local safety codes. 1. National Electrical Code ANSI/NFPS No. 70 or Canadian Electrical Code Part 1, C22.1 (latest editions). 2. National Fuel Gas Code Z223.1 or CAN/CGA B149.1 or .2 Installation Code. 3. ...

  • York D2NA060 - page 4

    Refer to Figure 5 for information concerning rear and bottom supply and return air duct openings. ROOF CURB On applications when a roof curb is used, the unit must be posi - tioned on the curb so the front of the unit is tight against the curb. FILTERS Single phase units are shipped without a filter and is the responsi - bility of the installer to ...

  • York D2NA060 - page 5

    Scroll compressors operate in one direction only . If a three phase scroll compressor is experiencing: • Low amperage draw • Similar discharge and suction pressures • Increased noise level then the compressor is operating in reverse. T o correct this condition, switch any two (2) line voltage leads at the contactor . Please note, single phase ...

  • York D2NA060 - page 6

    3. Use wrought iron or steel pipe for all gas lines. Pipe dope should be applied sparingly to male threads only . CAUTION: If flexible stainless steel tubing is allowed by the authority having jurisdiction, wrought iron or steel pipe must be installed at the gas valve and extend a minimum of two (2) inches outside of the unit casing. WARNING: Natur ...

  • York D2NA060 - page 7

    035-18265-001-A-0202 Unitary Products Group 7 FIG . 4 - CENTER OF GRA VITY 25 24 CENTER OF GRA VITY FRONT OF UNIT CORNER “C” CORNER “D” CORNER “A” CORNER “B” T ABLE 7 - UNIT WEIGHTS MODEL DNA UNIT SHIPPING WEIGHT (lbs.) UNIT OPERA TING WEIGHT (lbs.) CORNER OPERA TING WEIGHTS (lbs., location, see Figure 4) “A” “B” “C” “ ...

  • York D2NA060 - page 8

    035-18265-001-A-0202 8 Unitary Products Group FIG . 5 - DIMENSIONS AND CLEARANCES CLEARANCES (Minimum) Front 36" Back 0" Left Side (Filter Access) 24" Right Side 12" Below Unit 1 0" Above Unit 2 36" (For Condenser Air Discharge) 15 4 REAR SIDE RETURN AIR OPENING SIDE SUPPL Y AIR OPENING BOTTOM RETURN AIR OPENING 15 15 ...

  • York D2NA060 - page 9

    HEA TING When the thermostat calls for “HEA T”, the thermostat terminal “W” is energized, energizing the combustion air blower . After airflow is established, the air proving switch closes, the hot surface ignitor is energized and the pilot valve opens ignit - ing the pilot flame. The system will try to light the pilot for 90 seconds. After ...

  • York D2NA060 - page 10

    2. Check for correct manifold gas pressures. See “Checking Gas Input”. 3. Check the supply gas pressure. It must be within the limits shown on rating nameplate. Supply pressure should be checked with all gas appliances in the building at full fire. At no time should the standby gas line pressure exceed 10.5", nor the operating pressure dro ...

  • York D2NA060 - page 11

    3. After maintenance of the pilot assembly , always measure the resistance across the ignitor . If the resistance is greater than 10 ohms, discard the ignitor and replace it with a new ignitor . ADJUSTMENT OF TEMPERATURE RISE The temperature rise (or temperature difference between the return air and the heated air from the furnace) must lie within ...

  • York D2NA060 - page 12

    NORMAL MAINTENANCE WARNING: Prior to any of the following maintenance proce - dures, shut off all power to the unit, to avoid per - sonal injury . Periodic maintenance consists of changing or cleaning filters. Under some conditions, the main burners should be cleaned. FILTERS - Inspect once a month. Replace Disposable or clean Permanent T ype as ne ...

  • York D2NA060 - page 13

    Checking Supply Air CFM T o check the supply air CFM after the initial balancing has been completed: 1.Remove the two ¼ inch dot plugs in the duct panel. 2.Insert at least 8 inches of ¼ inch tubing into each of these holes for sufficient penetration into the airflow on both sides of the indoor coil. 3.Using an inclined manometer , determine the p ...

  • York D2NA060 - page 14

    14 Unitary Products Group 035-18265-001-A-0202 T ABLE 1 1 - SUPERHEA T CHARGING T ABLE FOR MODEL D1NA024 OUTDOOR TEMPERATURE (F) SUPERHEA T A T COMPRESSOR SUCTION (F), AIRFLOW = 400 CFM/TON INDOOR WB TEMPERATURE (F) 55 57 59 61 63 65 67 69 71 73 75 65 13.9 16.5 19.0 21.5 24.1 26.6 29.2 29.7 30.3 30.9 31.5 70 9.5 12.5 15.5 18.5 21.5 24.5 27.5 28.2 2 ...

  • York D2NA060 - page 15

    Unitary Products Group 15 035-18265-001-A-0202 T ABLE 14 - SUPERHEA T CHARGING T ABLE FOR MODEL D1NA042 OUTDOOR TEMPERATURE (F) SUPERHEA T A T COMPRESSOR SUCTION (F), AIRFLOW = 400 CFM/TON INDOOR WB TEMPERATURE (F) 55 57 59 61 63 65 67 69 71 73 75 65 18.0 19.7 21.4 23.0 24.7 26.3 28.0 29.1 30.2 31.3 32.4 70 13.4 15.3 17.3 19.3 21.2 23.2 25.2 26.6 2 ...

  • York D2NA060 - page 16

    16 Unitary Products Group 035-18265-001-A-0202 TROUBLESHOOTING YES . T urn gas supply off . Set thermostat to SV9501 is powered (24 V AC nominal) Igniter warms up and glows red Pilot valves opens T urn gas on. Pilot burner lights? Check . Line voltage power . Low voltage transformer . Main limit (Auto reset) . Rollout limit (Manual reset) . Auxilar ...

  • York D2NA060 - page 17

    Unitary Products Group 17 035-18265-001-A-0202 FIG . 9 - TYPICAL WIRING DIAGRAM (208/230-1-60 POWER SUPPL Y) FIG . 10 - TYPICAL WIRING DIAGRAM (208/230-3-60 POWER SUPPL Y) SEE DET AIL "A" (See page 18) ...

  • York D2NA060 - page 18

    18 Unitary Products Group 035-18265-001-A-0202 FIG . 1 1 - TYPICAL WIRING DIAGRAM (460-3-60 POWER SUPPL Y) FIG . 12 - TYPICAL WIRING DIAGRAM (575-3-60 POWER SUPPL Y) (See page 18) B (See page 18) B ...

  • York D2NA060 - page 19

    Unitary Products Group 19 035-18265-001-A-0202 (AL TERNA TE) (AL TERNA TE) TYPICAL WIRING DIAGRAM NOTES (See pages 16 and 17) TYPICAL WIRING DIAGRAM LEGEND (See pages 16 and 17) FIG . 13 - WIRING DIAGRAM DET AIL “B” (460 & 575-3-60 POWER SUPPL Y) See page 17 ...

  • York D2NA060 - page 20

    20 Unitary Products Group 035-18265-001-A-0202 NOTES ...

  • York D2NA060 - page 21

    Unitary Products Group 5005 Y ork Drive, Noman, Oklahoma 73069 Subject to change without notice. Printed in U.S.A. Copyright  by Y ork International Corporation 2000 All Rights Reserved. Supersedes: 035-18265-000-A-0801 035-18265-001-A-0202 ...

Производитель York Категория Air Conditioner

Документы, которые мы получаем от производителя устройства York D2NA060 мы можем разделить на несколько групп. Это в частности:
- технические чертежи York
- инструкции обслуживания D2NA060
- паспорта изделия York
- информационные брошюры
- энергетические этикетки York D2NA060
Все из них важны, однако самую важную информацию с точки зрения пользователя мы найдем в инструкции обслуживания York D2NA060.

Группа документов, определяемая как инструкции обслуживания, делится также на более подробные типы, такие как: Инструкции монтажа York D2NA060, инструкции обслуживания, короткие инструкции или инструкции пользователя York D2NA060. В зависимости от потребностей, Вам необходимо поискать требуемый документ. На нашем сайте Вы можете просмотреть самую популярную инструкцию использования изделия York D2NA060.

Похожие инструкции обслуживания

Полная инструкция обслуживания устройства York D2NA060, как должна выглядеть?
Инструкция обслуживания, определяемая также как пособие пользователя, или просто "руководство" - это технический документ, цель которого заключается в использовании York D2NA060 пользователями. Инструкции пишет, как правило технический писатель, языком, доступным для всех пользователей York D2NA060.

Полная инструкция обслуживания York, должна заключать несколько основных элементов. Часть из них менее важная, как например: обложка / титульный лист или авторские страницы. Однако остальная часть, должна дать нам важную с точки зрения пользователя информацию.

1. Вступление и рекомендации, как пользоваться инструкцией York D2NA060 - В начале каждой инструкции, необходимо найти указания, как пользоваться данным пособием. Здесь должна находится информация, касающаяся местонахождения содержания York D2NA060, FAQ и самых распространенных проблем - то есть мест, которые чаще всего ищут пользователи в каждой инструкции обслуживания
2. Содержание - индекс всех советов, касающихся York D2NA060, которое найдем в данном документе
3. Советы по использованию основных функций устройства York D2NA060 - которые должны облегчить нам первые шаги во время использования York D2NA060
4. Troubleshooting - систематизированный ряд действия, который поможет нам диагностировать а в дальнейшем очередность решения важнейших проблем York D2NA060
5. FAQ - чаще всего задаваемые вопросы
6. Контактные данные Информация о том, где искать контактные данные производителя / сервисного центра York D2NA060 в данной стране, если самостоятельно не получится решить проблему.

У вас вопрос, касающийся York D2NA060?

Воспользуйтесь формуляром, находящимся ниже

Если с помощью найденной инструкции Вы не решили свою проблему с York D2NA060, задайте вопрос, заполнив следующий формуляр. Если у какого то из пользователей была похожая проблема с York D2NA060 со всей вероятностью он захочет поделиться методом ее решения.

Перепишите текст с картинки

Комментарии (0)