    MODELS DESCRIBED I N THIS M ANUAL AT650, GS650 (650V A ) AT800, GS800 (800V A ) AT1200, GS1200 (1200V A) AT1600, GS1600 (1600V A) AT2300, GS2300 (2300V A) OWNER'S MANUAL ...

  • Minuteman UPS AT2300, GS2300 (2300VA) - page 2

    TABLE OF CONTENTS PA GE Introduction ………………………………………………………………. 1 Receiving Inspection …………………………………………………… 1 W arranty Registration ………………………………………………….. 1 Important Safety Instructions ………………………………? ...

  • Minuteman UPS AT2300, GS2300 (2300VA) - page 3

    1 INTRODUCTION Congratul ations o n your pur chase of a MINUT EMAN "AT " Series Synchr onized Sinewav e Uninterrupt ible Power Su pply (U PS). Eac h unit is design ed to pro vide su perior, total po wer protection f or pers onal com puters , telepho ne syst ems and any other sensit ive or crit ical el ectron ic equipm ent agains t all c o ...

  • Minuteman UPS AT2300, GS2300 (2300VA) - page 4

    2 the plug is rem oved to sim ulate a p ower f ailure (n ot recomm ended), d o not to uch the p lug conductors or the c hassis wh ile the lug is r emoved. CA UTI ON -- Do not allow water or any foreig n object to e nter the U PS. In c ase this occurs , immediate ly turn t he un it power s witch of f and unpl ug the MINUTEM AN from the comm ercial r ...

  • Minuteman UPS AT2300, GS2300 (2300VA) - page 5

    3 Route unit p ower-c ords so it cann ot be walk ed on or damage. ELECTRICA L SPECIFICATIONS Electrica l Specific ations Rated Output Model VA Watts Freq. HZ Input VAC/A Output VAC/A Battery Sy stem VDC Back Up Full Load Time (Min) Half Load Max Heat Dissipation BTU/HR AT650 650 455 60 120/6.0 120/5.4 24 6 15 311 GS650 650 455 50 220/3.3 220/3.0 24 ...

  • Minuteman UPS AT2300, GS2300 (2300VA) - page 6

    4 OTHER ELECTRICA L SPECIFICA TIONS Electrical Specif i cati ons Input Volta ge ( AC Mode Func tion) 120VAC ± 15 VAC; 2 25 VAC ± 35VAC Input Frequ ency De viation f or S ynchronizat ion ± 5% Inrush Curre nt 1.5xRated Surge Prot ectio n 3 wa y, meets IEEE STD 587 RFI/EMI Filteri ng Both Comm on & Norm al Modes Transf er 120VAC Units 220 VAC U ...

  • Minuteman UPS AT2300, GS2300 (2300VA) - page 7

    5 A ll Model s: Operating T em perature 0ºC to 40 ºC (32ºF t o 104ºF) Storage T emper ature -15ºC to 4 0ºC (5ºF to 10 4ºF) Relative H um idity 95% max imum at 25ºC Non-C ondensi ng Audible N oise 40 dB ANSI Sca le A, at 3' UNIT DESCRIPTION A T S YCHRONIZED SINEWAVE MODELS 1. Power Switch. 2. Alarm Silencer/T est m om entary rocker swi ...

  • Minuteman UPS AT2300, GS2300 (2300VA) - page 8

    6 5. AC Fault LED ( Yellow/Red) : Yello w when com m ercial input voltag e is los t or too low or in put frequ ency s hifts dr asticall y and unit switches to inv erter m ode. Red when comm er cial input voltage is too high a nd unit s witches to inver ter m ode . Both sta y on until f ault is cleare d. Off as long as comm ercial voltage is present ...

  • Minuteman UPS AT2300, GS2300 (2300VA) - page 9

    7 Turn on the UPS p ower s witch ("1" position) and v erif y that the "AC Norm al" LED (Green) il lum inates after a short d elay. T his is the AC Norm al Mode . Leave the UP S in this p osition f or approx im ately 30 sec onds m inimum . Depress the UPS "Test/Alar m Sil encer" rock er switch to ward the "Tes t&qu ...

  • Minuteman UPS AT2300, GS2300 (2300VA) - page 10

    8 frequenc y shif t will cause the "AC Fa ult" lig ht to turn yello w and a b lown f use or tri pped circ uit break er will caus e the fus e/break er light to illum inate (RE D). The audi ble alarm can be s ilenced in both th e "Norm al Inv erter" an d the "Lo w Batter y W arning" modes by depres sing the "Tes t/A ...

  • Minuteman UPS AT2300, GS2300 (2300VA) - page 11

    9 BATTERY /SYSTEM CHECKOUT To verif y proper s ystem function a nd batter y condit ion, th e user is encour aged to en gage th e test switch per iodical ly. Nor mal ind ications as specif ied s hould be obser ved. If the s ystem goes imm ediatel y to the low bat tery-war ning m ode the b atteries s hould be r eplac ed. UPS MONITORING CONFIGURATIONS ...

  • Minuteman UPS AT2300, GS2300 (2300VA) - page 12

    10 UPS DB9 PIN OU T PIN 2 -- S IMULA TED CL OS URE to pi n 8 a t Utili ty Fail ure PIN 3 -- S IMULA TED CL OS URE to Pin 8 at Low Ba tt ery W arn in g PIN 4 -- UP S INVERT ER SHUT DOWN : W hen a high (+ 5VDC m inimum ) is provided f or 10 m sec. PIN 5 -- SIG NAL GRO UND PIN 8 -- COMMON RET URN FOR PINS 2 A ND 3 SERVICE If any pro blem s are obser v ...

  • Minuteman UPS AT2300, GS2300 (2300VA) - page 13

    11 to identif y a bad slow blo w fuse v isuall y. If the fus e is blo wn, replac e it with a fus e of the sam e t ype and rat ings. Reset bre aker if tripped. Unit drops or reboo ts com puter but c ontinues to run in Inver ter Mode. Unit is slight ly overloa ded. D isconnect s ome of the load and tr y again. Unit goes imm ediatel y to low batter y ...

  • Minuteman UPS AT2300, GS2300 (2300VA) - page 14

    12 PARA SYSTEMS, INC. Tel: ( 972) 446-7363 1455 LeM ay, Carrollton , TX 75006 Fax : (972) 446-90 11 LIMITED PRODUCT WARRANTY PARA SYSTEMS, INC. (PARA SY STEMS) warrants that thi s product w ill be free fr om defe ctive mat erial and workmanship f or a peri od of tw o years from th e date of the origina l retail pur chase by the end u ser provided t ...

Производитель Minuteman UPS Категория Power Supply

Документы, которые мы получаем от производителя устройства Minuteman UPS AT2300, GS2300 (2300VA) мы можем разделить на несколько групп. Это в частности:
- технические чертежи Minuteman UPS
- инструкции обслуживания AT2300, GS2300 (2300VA)
- паспорта изделия Minuteman UPS
- информационные брошюры
- энергетические этикетки Minuteman UPS AT2300, GS2300 (2300VA)
Все из них важны, однако самую важную информацию с точки зрения пользователя мы найдем в инструкции обслуживания Minuteman UPS AT2300, GS2300 (2300VA).

Группа документов, определяемая как инструкции обслуживания, делится также на более подробные типы, такие как: Инструкции монтажа Minuteman UPS AT2300, GS2300 (2300VA), инструкции обслуживания, короткие инструкции или инструкции пользователя Minuteman UPS AT2300, GS2300 (2300VA). В зависимости от потребностей, Вам необходимо поискать требуемый документ. На нашем сайте Вы можете просмотреть самую популярную инструкцию использования изделия Minuteman UPS AT2300, GS2300 (2300VA).

Похожие инструкции обслуживания

Полная инструкция обслуживания устройства Minuteman UPS AT2300, GS2300 (2300VA), как должна выглядеть?
Инструкция обслуживания, определяемая также как пособие пользователя, или просто "руководство" - это технический документ, цель которого заключается в использовании Minuteman UPS AT2300, GS2300 (2300VA) пользователями. Инструкции пишет, как правило технический писатель, языком, доступным для всех пользователей Minuteman UPS AT2300, GS2300 (2300VA).

Полная инструкция обслуживания Minuteman UPS, должна заключать несколько основных элементов. Часть из них менее важная, как например: обложка / титульный лист или авторские страницы. Однако остальная часть, должна дать нам важную с точки зрения пользователя информацию.

1. Вступление и рекомендации, как пользоваться инструкцией Minuteman UPS AT2300, GS2300 (2300VA) - В начале каждой инструкции, необходимо найти указания, как пользоваться данным пособием. Здесь должна находится информация, касающаяся местонахождения содержания Minuteman UPS AT2300, GS2300 (2300VA), FAQ и самых распространенных проблем - то есть мест, которые чаще всего ищут пользователи в каждой инструкции обслуживания
2. Содержание - индекс всех советов, касающихся Minuteman UPS AT2300, GS2300 (2300VA), которое найдем в данном документе
3. Советы по использованию основных функций устройства Minuteman UPS AT2300, GS2300 (2300VA) - которые должны облегчить нам первые шаги во время использования Minuteman UPS AT2300, GS2300 (2300VA)
4. Troubleshooting - систематизированный ряд действия, который поможет нам диагностировать а в дальнейшем очередность решения важнейших проблем Minuteman UPS AT2300, GS2300 (2300VA)
5. FAQ - чаще всего задаваемые вопросы
6. Контактные данные Информация о том, где искать контактные данные производителя / сервисного центра Minuteman UPS AT2300, GS2300 (2300VA) в данной стране, если самостоятельно не получится решить проблему.

У вас вопрос, касающийся Minuteman UPS AT2300, GS2300 (2300VA)?

Воспользуйтесь формуляром, находящимся ниже

Если с помощью найденной инструкции Вы не решили свою проблему с Minuteman UPS AT2300, GS2300 (2300VA), задайте вопрос, заполнив следующий формуляр. Если у какого то из пользователей была похожая проблема с Minuteman UPS AT2300, GS2300 (2300VA) со всей вероятностью он захочет поделиться методом ее решения.

Перепишите текст с картинки

Комментарии (0)