  • Trane TUH2C100A9V4VA - page 1

    XV 95 TUH2B060A9V3V A TUH2B080A9V3V A TUH2B080A9V4V A TUH2C100A9V4V A TUH2C100A9V5V A TUH2D120A9V5V A PUB. NO . 22-1814-08 Upflo w/ Horizontal Left, Do wnflo w/ Horizontal Right V ariab le Speed T w o Sta g e Condensing Gas-Fired Furnace UPFLO W *UH-A9V -V UPFLO W/HORIZONT AL *DH-A9V -V DO WNFLO W DO WNFLO W/HORIZONT AL Direct V ent with V ariabl ...

  • Trane TUH2C100A9V4VA - page 2

    2 Pub . No . 22-1814-08 General Features © 2012 T rane All Rights Reser ved NA TURAL GAS MODELS Central Heating furnace designs are certified by the American Gas Associa - tio n for both natur al and L.P . gas. Limit setting and rating data were estab lished and approv ed under standard rating conditions using American National Standards Institut ...

  • Trane TUH2C100A9V4VA - page 3

    3 Pub . No . 22-1814-08 Contents General Features 2 Features and Benefits 4 Standard Equipment 4 Optional Equipment 5 General Data 6-8 TUH2B060A9V3V A TUH2B080A9V3V A TUH2B080A9V4V A TUH2C100A9V4V A TUH2C100A9V5V A TUH2D120A9V5V A TDH2B060A9V3V A TDH2B080A9V3V A TDH2B080A9V4V A TDH2C100A9V4V A TDH2D120A9V5V A P erf ormance Data 9-19 V enting T abl ...

  • Trane TUH2C100A9V4VA - page 4

    4 Pub . No . 22-1814-08 XV 95 ST AND ARD EQUIPMENT Features and Benefits • Lite P or t ™ e xtended system diag - nostics • Stored f ault code history in micro pro - cessor nonv ocatile memor y • Cleanable high velocity lters (upo w only) • Hinged blow er door * • P erfect t door latches* • Insulated blower door* • Gasketed ...

  • Trane TUH2C100A9V4VA - page 5

    5 Pub . No . 22-1814-08 Features and Benefits XV 95 OPTIONAL EQUIPMENT Thermostat, 2-Stage Heat / 1-Stage Cooling ........................................................................................................... T A YST A T241 [ ] Thermostat, Media Programmable 2-Stage Heating ............................................................. ...

  • Trane TUH2C100A9V4VA - page 6

    6 Pub . No . 22-1814-08 General Data 1 Central Furnace heating designs are certified to ANSI Z21.47 / CSA 2.3 2 For U.S. applications, above input ratings (BTUH) are up to 2,000 feet, derate 4% per 1,000 feet for elevations above 2,000 feet above sea level. For Canadian applicaitons, above input ratings (BTUH) are up to 4,500 feet, derate 4% per 1 ...

  • Trane TUH2C100A9V4VA - page 7

    7 Pub . No . 22-1814-08 PRODUCT SPECIFICA TIONS 1 MODEL TYPE RA TINGS 2 1st Stage Input BTUH 1st Stage Capacity BTUH (ICS) 3 2nd Stage Input BTUH 2nd Stage Capacity BTUH (ICS) 3 AFUE T emp. rise (Min.-Max.) °F . BLO WER DRIVE Diameter - Width (In.) No . Used Speeds (No .) CFM vs. in. w .g. Motor HP R.P .M. V olts / Ph / Hz COMBUSTION F AN - T ype ...

  • Trane TUH2C100A9V4VA - page 8

    8 Pub . No . 22-1814-08 PRODUCT SPECIFICA TIONS 1 MODEL TYPE RA TINGS 2 1st Stage Input BTUH 1st Stage Capacity BTUH (ICS) 3 2nd Stage Input BTUH 2nd Stage Capacity BTUH (ICS) 3 AFUE T emp. rise (Min.-Max.) °F . BLO WER DRIVE Diameter - Width (In.) No . Used Speeds (No .) CFM vs. in. w .g. Motor HP R.P .M. V olts / Ph / Hz COMBUSTION F AN - T ype ...

  • Trane TUH2C100A9V4VA - page 9

    9 Pub . No . 22-1814-08 *UH2B060A9V3V FURNA CE COOLING AIRFLOW (CFM) AND PO WER (W A TTS) VS. EXTERNAL ST A TIC PRESSURE WITH FIL TER OUTDOOR UNIT SIZE (T ONS) AIRFLOW SETTING DIP SWITCH SETTING EXTERNAL ST A TIC PRESSURE SW 1 SW 2 SW 3 SW 4 0.1 0.3 0.5 0.7 0.9 1.5 LOW (350 CFM/T ON) ON ON OFF ON CFM W A TTS 575 65 575 90 575 125 550 155 - NORMAL ( ...

  • Trane TUH2C100A9V4VA - page 10

    10 Pub . No . 22-1814-08 *UH2B080A9V3V FURNA CE HEA TING AIRFLO W (CFM) AND PO WER (W A TTS) VS. EXTERNAL ST A TIC PRESSURE WITH FIL TER 1st Stage Capacity = 2nd Stage Capacity = 50,440 77,600 AIRFLOW SETTING DIP SWITCH SETTING EXTERNAL ST A TIC PRESSURE SW 7 SW 8 0.1 0.3 0.5 0.7 0.9 HEA TING 1ST ST AGE LOW ON ON CFM TEMP . RISE W A TTS 800 56 105 ...

  • Trane TUH2C100A9V4VA - page 11

    11 Pub . No . 22-1814-08 *UH2B080A9V4V FURNA CE HEA TING AIRFLO W (CFM) AND PO WER (W A TTS) VS. EXTERNAL ST A TIC PRESSURE WITH FIL TER 1st Stage Capacity = 2nd Stage Capacity = 50,440 77,600 AIRFLOW SETTING DIP SWITCH SETTING EXTERNAL ST A TIC PRESSURE SW 7 SW 8 0.1 0.3 0.5 0.7 0.9 HEA TING 1ST ST AGE LOW ON ON CFM TEMP . RISE W A TTS 800 56 105 ...

  • Trane TUH2C100A9V4VA - page 12

    12 Pub . No . 22-1814-08 *UH2C100A9V4V FURNA CE COOLING AIRFLOW (CFM) AND PO WER (W A TTS) VS. EXTERNAL ST A TIC PRESSURE WITH FIL TER OUTDOOR UNIT SIZE (T ONS) AIRFLOW SETTING DIP SWITCH SETTING EXTERNAL ST A TIC PRESSURE SW 1 SW 2 SW 3 SW 4 0.1 0.3 0.5 0.7 0.9 2.5 LOW (350 CFM/T ON) ON ON OFF ON CFM W A TTS 808 75 824 125 840 170 835 210 830 250 ...

  • Trane TUH2C100A9V4VA - page 13

    13 Pub . No . 22-1814-08 *UH2C100A9V5V FURNA CE HEA TING AIRFLO W (CFM) AND PO WER (W A TTS) VS. EXTERNAL ST A TIC PRESSURE WITH FIL TER 1st Stage Capacity = 2nd Stage Capacity = 62,855 96,700 AIRFLOW SETTING DIP SWITCH SETTING EXTERNAL ST A TIC PRESSURE SW 7 SW 8 0.1 0.3 0.5 0.7 0.9 HEA TING 1ST ST AGE LOW ON ON CFM TEMP . RISE W A TTS 873 64 100 ...

  • Trane TUH2C100A9V4VA - page 14

    14 Pub . No . 22-1814-08 *UH2D120A9V5V FURNA CE COOLING AIRFLOW (CFM) AND PO WER (W A TTS) VS. EXTERNAL ST A TIC PRESSURE WITH FIL TER OUTDOOR UNIT SIZE (T ONS) AIRFLOW SETTING DIP SWITCH SETTING EXTERNAL ST A TIC PRESSURE SW 1 SW 2 SW 3 SW 4 0.1 0.3 0.5 0.7 0.9 3.5 LOW (350 CFM/T ON) OFF ON OFF ON CFM W A TTS 1210 220 1210 270 1220 325 1230 400 12 ...

  • Trane TUH2C100A9V4VA - page 15

    15 Pub . No . 22-1814-08 *DH2B060A9V3V FURNA CE HEA TING AIRFLO W (CFM) AND PO WER (W A TTS) VS. EXTERNAL ST A TIC PRESSURE WITH FIL TER 1st ST AGE CAP ACITY = 2nd ST AGE CAP ACITY = 37,440 57,600 AIRFLOW SETTING DIP SWITCH SETTING EXTERNAL ST A TIC PRESSURE SW 7 SW 8 0.1 0.3 0.5 0.7 0.9 HEA TING 1ST ST AGE LOW ON ON CFM TEMP . RISE W A TTS 600 56 ...

  • Trane TUH2C100A9V4VA - page 16

    16 Pub . No . 22-1814-08 *DH2B080A9V3V - FURNA CE COOLING AIRFLOW (CFM) AND PO WER (W A TTS) VS. EXTERNAL ST A TIC PRESSURE WITH FIL TER OUTDOOR UNIT SIZE (T ONS) AIRFLOW SETTING DIP SWITCH SETTING EXTERNAL ST A TIC PRESSURE SW 1 SW 2 SW 3 SW 4 0.1 0.3 0.5 0.7 0.9 2.0 LOW (350 CFM/T ON) ON ON OFF ON CFM W A TTS 700 95 700 105 700 115 680 200 670 23 ...

  • Trane TUH2C100A9V4VA - page 17

    17 Pub . No . 22-1814-08 *DH2B080A9V4V FURNA CE HEA TING AIRFLO W (CFM) AND PO WER (W A TTS) VS. EXTERNAL ST A TIC PRESSURE WITH FIL TER 1st ST AGE CAP ACITY = 2nd ST AGE CAP ACITY = 49,400 76,000 AIRFLOW SETTING DIP SWITCH SETTING EXTERNAL ST A TIC PRESSURE SW 7 SW 8 0.1 0.3 0.5 0.7 0.9 HEA TING 1ST ST AGE LOW ON ON CFM TEMP . RISE W A TTS 800 56 ...

  • Trane TUH2C100A9V4VA - page 18

    18 Pub . No . 22-1814-08 *DH2C100A9V4V - FURNA CE HEA TING AIRFLO W (CFM) AND PO WER (W A TTS) VS. EXTERNAL ST A TIC PRESSURE WITH FIL TER 1st ST AGE CAP ACITY = 2nd ST AGE CAP ACITY = 62,400 96,000 AIRFLOW SETTING DIP SWITCH SETTING EXTERNAL ST A TIC PRESSURE SW 7 SW 8 0.1 0.3 0.5 0.7 0.9 HEA TING 1ST ST AGE LOW ON ON CFM TEMP . RISE W A TTS 923 6 ...

  • Trane TUH2C100A9V4VA - page 19

    19 Pub . No . 22-1814-08 *DH2D120A9V5V - FURNA CE HEA TING AIRFLO W (CFM) AND PO WER (W A TTS) VS. EXTERNAL ST A TIC PRESSURE WITH FIL TER 1st ST AGE CAP ACITY = 2nd ST AGE CAP ACITY = 74,880 115,200 AIRFLOW SETTING DIP SWITCH SETTING EXTERNAL ST A TIC PRESSURE SW 8 SW 7 0.1 0.3 0.5 0.7 0.9 HEA TING 1ST ST AGE LOW ON ON CFM TEMP . RISE W A TTS 1025 ...

  • Trane TUH2C100A9V4VA - page 20

    20 Pub . No . 22-1814-08 Maxim um V ent Length T able VENT LENGTH T ABLE AL TITUDE MAXIMUM T OT AL EQUIV ALENT LENGTH IN FEET FOR VENT AND INLET AIR (SEE NO TES) 0-7,000 F eet 2 INCH PIPE 2.5 INCH PIPE 3 or 4 INCH PIPE *UH/DH2B060A9V3V A 200 200 200 *UH/DH2B080A9V3V A *UH/DH2B080A9V4V A 50 120 200 *UH/DH2C100A9V4V A *UH2C100A9V5V A Not Allowed 60 2 ...

  • Trane TUH2C100A9V4VA - page 21

    21 Pub . No . 22-1814-08 Electrical Data *UH2 WIRING DIA GRAM F rom drawing D344303 ...

  • Trane TUH2C100A9V4VA - page 22

    22 Pub . No . 22-1814-08 Electrical Data *UH2 SCHEMA TIC DIA GRAM F rom drawing D344303 ...

  • Trane TUH2C100A9V4VA - page 23

    23 Pub . No . 22-1814-08 *DH2 WIRING DIA GRAM Electrical Data F rom drawing D344304 ...

  • Trane TUH2C100A9V4VA - page 24

    24 Pub . No . 22-1814-08 *DH2 SCHEMA TIC DIA GRAM Electrical Data F rom drawing D344304 ...

  • Trane TUH2C100A9V4VA - page 25

    25 Pub . No . 22-1814-08 FIELD WIRING DIA GRAM FOR SINGLE ST A GE HEA TING ONL Y FIELD WIRING DIA GRAM FOR TWO ST A GE HEA TING ONL Y Field Wiring ...

  • Trane TUH2C100A9V4VA - page 26

    26 Pub . No . 22-1814-08 Field Wiring FIELD WIRING DIA GRAM FOR SINGLE ST A GE HEA TING/COOLING (OUTDOOR SECTION WITHOUT TRANSFORMER) FIELD WIRING DIA GRAM FOR TWO ST A GE HEA TING/ SINGLE ST A GE COOLING (OUTDOOR SECTION WITHOUT TRANSFORMER) ...

  • Trane TUH2C100A9V4VA - page 27

    27 Pub . No . 22-1814-08 Dimensions *UH2 UPFLO W / HORIZONT AL OUTLINE DRA WING (ALL DIMENSIONS ARE IN INCHES) ...

  • Trane TUH2C100A9V4VA - page 28

    28 Pub . No . 22-1814-08 *DH2 DO WNFLO W / HORIZONT AL OUTLINE DRA WING (ALL DIMENSIONS ARE IN INCHES) Dimensions ...

  • Trane TUH2C100A9V4VA - page 29

    29 Pub . No . 22-1814-08 Notes ...

  • Trane TUH2C100A9V4VA - page 30

    T rane has a policy of continuous product and product data improv ement and i t reser ves the right to change design and specifications without notice. T rane 6200 T roup Highwa y T yler, TX 75707 www .trane.com ...

Производитель Trane Категория Furnace

Документы, которые мы получаем от производителя устройства Trane TUH2C100A9V4VA мы можем разделить на несколько групп. Это в частности:
- технические чертежи Trane
- инструкции обслуживания TUH2C100A9V4VA
- паспорта изделия Trane
- информационные брошюры
- энергетические этикетки Trane TUH2C100A9V4VA
Все из них важны, однако самую важную информацию с точки зрения пользователя мы найдем в инструкции обслуживания Trane TUH2C100A9V4VA.

Группа документов, определяемая как инструкции обслуживания, делится также на более подробные типы, такие как: Инструкции монтажа Trane TUH2C100A9V4VA, инструкции обслуживания, короткие инструкции или инструкции пользователя Trane TUH2C100A9V4VA. В зависимости от потребностей, Вам необходимо поискать требуемый документ. На нашем сайте Вы можете просмотреть самую популярную инструкцию использования изделия Trane TUH2C100A9V4VA.

Похожие инструкции обслуживания

Полная инструкция обслуживания устройства Trane TUH2C100A9V4VA, как должна выглядеть?
Инструкция обслуживания, определяемая также как пособие пользователя, или просто "руководство" - это технический документ, цель которого заключается в использовании Trane TUH2C100A9V4VA пользователями. Инструкции пишет, как правило технический писатель, языком, доступным для всех пользователей Trane TUH2C100A9V4VA.

Полная инструкция обслуживания Trane, должна заключать несколько основных элементов. Часть из них менее важная, как например: обложка / титульный лист или авторские страницы. Однако остальная часть, должна дать нам важную с точки зрения пользователя информацию.

1. Вступление и рекомендации, как пользоваться инструкцией Trane TUH2C100A9V4VA - В начале каждой инструкции, необходимо найти указания, как пользоваться данным пособием. Здесь должна находится информация, касающаяся местонахождения содержания Trane TUH2C100A9V4VA, FAQ и самых распространенных проблем - то есть мест, которые чаще всего ищут пользователи в каждой инструкции обслуживания
2. Содержание - индекс всех советов, касающихся Trane TUH2C100A9V4VA, которое найдем в данном документе
3. Советы по использованию основных функций устройства Trane TUH2C100A9V4VA - которые должны облегчить нам первые шаги во время использования Trane TUH2C100A9V4VA
4. Troubleshooting - систематизированный ряд действия, который поможет нам диагностировать а в дальнейшем очередность решения важнейших проблем Trane TUH2C100A9V4VA
5. FAQ - чаще всего задаваемые вопросы
6. Контактные данные Информация о том, где искать контактные данные производителя / сервисного центра Trane TUH2C100A9V4VA в данной стране, если самостоятельно не получится решить проблему.

У вас вопрос, касающийся Trane TUH2C100A9V4VA?

Воспользуйтесь формуляром, находящимся ниже

Если с помощью найденной инструкции Вы не решили свою проблему с Trane TUH2C100A9V4VA, задайте вопрос, заполнив следующий формуляр. Если у какого то из пользователей была похожая проблема с Trane TUH2C100A9V4VA со всей вероятностью он захочет поделиться методом ее решения.

Перепишите текст с картинки

Комментарии (0)