  • Altinex CP7317RS - page 1

    CONTROLLERS CP7317RS RS – 232 CONTROLLER USER’S GUIDE MANUAL PART NO. 400-0017-003 PRODUCT REVISION: 0 ...

  • Altinex CP7317RS - page 2

    CONTROLLERS 1 INTRODUCTION Thank you for purchasing the CP7317RS RS-232 Controller. We are sure you will find it a reliable and useful product. Superior performance for the right price backed by solid technical and customer support is what we have to offer. The product you are holding in your hands is designed using state-of-the-art technology and ...

  • Altinex CP7317RS - page 3

    CONTROLLERS 2 PRECAUTIONS / SAFETY WARNINGS 1 Please read this manual carefully before using your CP7317RS RS-232 Controller. Keep this manual handy for future reference. These safety instructions are to ensure the long life of your CP7317RS and to prevent fire and shock hazard. Please read them carefully and heed all warnings. 1.1 GENERAL • Unau ...

  • Altinex CP7317RS - page 4

    CONTROLLERS 3 ABOUT CP7317RS - RS-232 CONTROLLER 2 The CP7317RS RS-232 Controller is designed to provide expanded capabilities to any control system. The CP7317RS is designed to accept RS- 232 commands from a control device and output those commands as relay contacts or digital high or low. The CP7317RS also is able to convert digital inputs throug ...

  • Altinex CP7317RS - page 5

    CONTROLLERS 4 CP7317RS DESCRIPTION 4 CP7317RS FEATURES 4.1 RS-232 PORT This port (located next to the power outlet) is a fully programmable, bi-directional, and full duplex port that has the ability to operate at any baud rate up to 9600. The general standard on transmission is 8 bits, no parity, and 1 stop bit. The factory default for communicatio ...

  • Altinex CP7317RS - page 6

    CONTROLLERS 5 The following table shows the pin-outs on the connector corresponding to the following I/O port pin numbers. Connector Pin No. 1 2 3 4 5 6 7 8 9 I/O Port Pin No. 1 3 5 7 9 Ground 2 4 6 8 There are 4 ports with 8 I/O pins and one ground pin, #5 on each port. Each pin of each port can be individually addressed and programmed to be high ...

  • Altinex CP7317RS - page 7

    CONTROLLERS 6 4.7 PROGRAMING COM MANDS The commands below are used for presetting the default status of the unit. Note: AFTER USING THE PROGRAMMING COMMANDS LISTED BELOW, THE CP7317RS SHOULD BE POWERED OFF AND THEN ON. [SETIp,b,n] This command sets individual pins of each I/O port to input or output status. It is a programming command and needs to ...

  • Altinex CP7317RS - page 8

    CONTROLLERS 7 b This letter defines the status of a pin, while its position in a string number corresponds to the pin number on the I/O Port of the CP7317RS . For example b 4 represents the status of Pin 4 on the I/O connector. The valid pins on I/O port are from 1 to 9 except 5. A valid range for the b is either 1 or 0. Any other number will cause ...

  • Altinex CP7317RS - page 9

    CONTROLLERS 8 FIGURE 6: Input/Output Port Pin Configuration n This letter designates the status of the pin as either high or low during “Power up” of the unit. when n = 1 the pin is set as high when n = 0 the pin is set as low Example: Set pin 1 of port 3 as low during POWER ON. [SETPD3 ,1,0] [SETPDp,b 1 b 6 b 2 b 7 b 3 b 8 b 4 b 9 ] This comma ...

  • Altinex CP7317RS - page 10

    CONTROLLERS 9 n This letter designates the status of the relay during “Power up”. n=1 relay is open n=0 relay is closed Example: Set relay 6 of port 2 to be open at power up. [SETPR2,6,1] Set relay 2 of port 4 to be closed at power up. [SETPR4,2,0] [ SETPRp ,b 1 b 2 b 3 b 4 b 5 b 6 b 7 b 8 ] This command sets the “Power ON” status of all re ...

  • Altinex CP7317RS - page 11

    CONTROLLERS 10 Bit No. Connector Pin No. 7 4 8 9 n Data that defines the status of the pin n=1 or n=0. [SETDp, b 1 b 6 b 2 b 7 b 3 b 8 b 4 b 9 ] SET all pins on the particular I/O port of the unit. This command defines if I/O port pins will be high or low. The pin must be set as output if it needs to be set low. If particular pin is set as input th ...

  • Altinex CP7317RS - page 12

    CONTROLLERS 11 [READDp] Read Digital status of a particular port. The feedback is in the following format [10011100] 1 is for high 0 is for low. The feedback provides status of all pins. Left most character is a bit pin number 1. p Port number, this is an ASCII character from 1 to 4 that matches the port number on the back of the CP7317RS . The acc ...

  • Altinex CP7317RS - page 13

    CONTROLLERS 12 4.10.1. MEMORY 1 I/O port/memory is A Sub-Register address is from 00 to 255 Sub-Register definitions 00 This location should be set to FFh i f memory initialization is required. During the power up sequence this location is checked for software revision. If FFh is encountered then all memories are reset to factory condition. User me ...

  • Altinex CP7317RS - page 14

    CONTROLLERS 13 33 Power up status of relays on port 2,3,4. If bit is set to 0 then relay will be closed on power up. If bit is set to 1 then relay will be open on power up. 34 Left bracket for beginning command code. Factory set to “[“. 35 Right bracket for ending command code. Factory set to “]“. 36 Power on default status of digital port ...

  • Altinex CP7317RS - page 15

    CONTROLLERS 14 08 00-07 locations for return code for port 1 pin 2 for transition from 0 to 1. This return code should include any necessary brackets. . . . . 15 end of return code Default return code is in the following format [Px.yd] x port number 1, 2, 3, 4 y pin number 1, 2, 3, 4, 5, 6, 7, 8 d direction U for 0-> 1 or D for 1->0 transitio ...

  • Altinex CP7317RS - page 16

    CONTROLLERS 15 ALTINEX POLICY 5 5.1 LIMITED WARRANTY Altinex warrants that its products and cables are free from defects in materials under normal use and service. This warranty is limited to repairing at company’s factory any part or parts of the product, which upon company’s examination shall disclose to be, thus defective. Products considere ...

Производитель Altinex Категория Network Card

Документы, которые мы получаем от производителя устройства Altinex CP7317RS мы можем разделить на несколько групп. Это в частности:
- технические чертежи Altinex
- инструкции обслуживания CP7317RS
- паспорта изделия Altinex
- информационные брошюры
- энергетические этикетки Altinex CP7317RS
Все из них важны, однако самую важную информацию с точки зрения пользователя мы найдем в инструкции обслуживания Altinex CP7317RS.

Группа документов, определяемая как инструкции обслуживания, делится также на более подробные типы, такие как: Инструкции монтажа Altinex CP7317RS, инструкции обслуживания, короткие инструкции или инструкции пользователя Altinex CP7317RS. В зависимости от потребностей, Вам необходимо поискать требуемый документ. На нашем сайте Вы можете просмотреть самую популярную инструкцию использования изделия Altinex CP7317RS.

Похожие инструкции обслуживания

Полная инструкция обслуживания устройства Altinex CP7317RS, как должна выглядеть?
Инструкция обслуживания, определяемая также как пособие пользователя, или просто "руководство" - это технический документ, цель которого заключается в использовании Altinex CP7317RS пользователями. Инструкции пишет, как правило технический писатель, языком, доступным для всех пользователей Altinex CP7317RS.

Полная инструкция обслуживания Altinex, должна заключать несколько основных элементов. Часть из них менее важная, как например: обложка / титульный лист или авторские страницы. Однако остальная часть, должна дать нам важную с точки зрения пользователя информацию.

1. Вступление и рекомендации, как пользоваться инструкцией Altinex CP7317RS - В начале каждой инструкции, необходимо найти указания, как пользоваться данным пособием. Здесь должна находится информация, касающаяся местонахождения содержания Altinex CP7317RS, FAQ и самых распространенных проблем - то есть мест, которые чаще всего ищут пользователи в каждой инструкции обслуживания
2. Содержание - индекс всех советов, касающихся Altinex CP7317RS, которое найдем в данном документе
3. Советы по использованию основных функций устройства Altinex CP7317RS - которые должны облегчить нам первые шаги во время использования Altinex CP7317RS
4. Troubleshooting - систематизированный ряд действия, который поможет нам диагностировать а в дальнейшем очередность решения важнейших проблем Altinex CP7317RS
5. FAQ - чаще всего задаваемые вопросы
6. Контактные данные Информация о том, где искать контактные данные производителя / сервисного центра Altinex CP7317RS в данной стране, если самостоятельно не получится решить проблему.

У вас вопрос, касающийся Altinex CP7317RS?

Воспользуйтесь формуляром, находящимся ниже

Если с помощью найденной инструкции Вы не решили свою проблему с Altinex CP7317RS, задайте вопрос, заполнив следующий формуляр. Если у какого то из пользователей была похожая проблема с Altinex CP7317RS со всей вероятностью он захочет поделиться методом ее решения.

Перепишите текст с картинки

Комментарии (0)