    1 W ARNING DO NOT INST ALL THE ACTUAL SMOKE ALARM IN NEW OR RENOV A TED BUILDINGS UNTIL ALL WORK IS COMPLETED (INCLUDING FLOOR COVERINGS) AND BUILDING HAS BEEN FULL Y CLEANED. (Excessive dust & debris from building work can contaminate the smoke chamber and cause problems). An installed smoke alarm must be removed or covered fully (with a plast ...

  • Ei Electronics Ei 405C - page 2

    1. READ THIS FIRST A Smoke Alarm is an early warning device. Used correctly it can give you and your family valuable extra time to escape. ¥ Models Ei405 & Ei405C - connect battery snaps firmly (see fig 1b). Press the test button and horn should sound. ¥ Models Ei405C, Ei405TY & Ei405TYC - slide unit on to mounting plate to connect the ba ...

  • Ei Electronics Ei 405C - page 3

    3 ¥ If the Alarm beeps without the red light flashing at the same time then clean unit as this is the automatic test fea- ture indicating the chamber is degraded. ¥ Plan your escape route. ¥ Proper protection usually requires more than one Smoke Alarm. ¥ If you have any doubt or query about Smoke Alarms con- sult the supplier or your local Fire ...

  • Ei Electronics Ei 405C - page 4

    4 excellent, particularly at night, as it rapidly identifies where the fire is located. This is ideal for larger systems as the dis- turbance in the house can be kept to a minimum e.g. no need to enter all the bedrooms to check to see if the red light is flashing rapidly . 3. LOCA TING YOUR SMOKE ALARM Sufficient smoke must enter your Smoke Alarm b ...

  • Ei Electronics Ei 405C - page 5

    Figure 2 : Single storey dwelling Figure 3: Single storey dwelling with separate sleeping areas. In houses with more than one sleeping area, Smoke Alarms should be placed between each sleeping area and the living area (for example, see figure 3). 3.2 Multi Storey Dwellings If your home has more than one floor , at least one alarm should be fitted o ...

  • Ei Electronics Ei 405C - page 6

    6 3.3 Recommended Protection For recommended protection you should put individual Smoke Alarms in all the rooms where fire is most likely to break out (apart from the locations to avoid, mentioned below). The living room is the most likely place for a fire to start at night, followed by the kitchen and then the dining room. Y ou should also conside ...

  • Ei Electronics Ei 405C - page 7

    7 4.3 On a sloping Ceiling In areas with sloping or peaked ceilings install your Smoke Alarm 0.9m from the highest point measured horizontally (see figure 6), because dead air at the apex may prevent smoke from reaching the unit. 4.4 Locations to Avoid Don t place your Smoke Alarm in any of the following areas: ¥ Bathrooms, kitchen, shower rooms, ...

  • Ei Electronics Ei 405C - page 8

    8 If there are frequent nuisance/false alarms it may be neces- sary to re-locate the device away from the source of the fumes. If you installed the smoke alarms as received and did not pro- gram them, you may be receiving an alarm signal from a neighbouring system. This can be easy rectified by house coding your alarms (see section 6.3). Pressing t ...

  • Ei Electronics Ei 405C - page 9

    9 If the alarm fails to sound, follow this checklist: ¥ Check the age of the unit - see the replace by label on base of unit. ¥ Check the battery snaps are firmly connected on the Ei405 & Ei405C models (see fig 1b). ¥ On the Ei405TY & Ei405TYC models ensure the unit is pushed fully home on the mounting plate, as this connects the battery ...

  • Ei Electronics Ei 405C - page 10

    10 Program Procedure 1. Press the test button on the first installed unit three times within 1.5 seconds. The blue light will come on momentarily each time to show the button is operating. (If the horn sounds during these short button depressions, just ignore it). The blue light will now flash once every 5 seconds. The unit now sends a radio messag ...

  • Ei Electronics Ei 405C - page 11

    11 Clear the serial numbers learned by: - disconnecting the battery - waiting 10 seconds - holding the test button down while re-connecting the battery snaps to the Ei405 & Ei405C only . With the Ei405TY & Ei405TYC models hold the test button down while sliding it on to the mounting plate. Then put it into the program mode by pressing the t ...

  • Ei Electronics Ei 405C - page 12

    12 The unit can be quickly removed from the program mode by holding down the T est & Locate buttons simultaneously . (The house coding can be removed, if necessary , from the remote control by first disconnecting the battery for 10 sec- onds and then reconnecting the battery while holding down both the T est & Locate buttons). 6.5 Power Ind ...

  • Ei Electronics Ei 405C - page 13

    13 6.8 Automatic Self-T est The smoke chamber automatically tests itself every 40 sec- onds. If the chamber is degraded it will beep without the red light flashing at the same time. If this happens clean the unit. If the beeping persists and the beep does not coincide with an red light flash, return the unit for service (see Getting your Smoke Alar ...

  • Ei Electronics Ei 405C - page 14

    14 (ii) Low Battery beeps (Model Ei 405TY & Ei405TYC only) The unit is giving a short beep every 40 seconds and the red light flashes at the same time for longer than 1 hour . (If the unit beeps without the red light flashing at the same time see Cleaning your Smoke Alarm above). (iii) The unit fails to sound the horn loudly when the test but- ...

  • Ei Electronics Ei 405C - page 15

    15 A maximum of 250 metres (820ft) of signal cable can be used, (maximum resistance between detectors 50 ohm). The units are interconnected by wiring all the terminals marked 1 together , and all the terminals marked 2 together (as in fig 8) before screwing the mounting plate to ceiling. Draughts, through the ceiling, from wiring openings, conduit, ...

  • Ei Electronics Ei 405C - page 16

    16 ¥ Constant exposure to high or freezing temperatures, high humidity or a high level of nuisance alarms may reduce the life of the battery . ¥ Nuisance alarms can be quickly silenced by fanning vigor- ously with a newspaper or similar to remove the smoke or press the test / hush button. ¥ Do not attempt to remove, recharge or burn the battery ...

  • Ei Electronics Ei 405C - page 17

    17 ¥ Smoke Alarms may not detect every type of fire to give suf- ficient early warning. They are particularly inef fective with: fires caused by smoking in bed, escaping gas, violent explosions. poor storage of flammable rags and/or liquids, (for example petrol, paint, spirits etc), overloaded electrical circuits, arson, children playing with matc ...

  • Ei Electronics Ei 405C - page 18

    18 8.2 FIRE SAFETY HINTS Store petrol and other flammable materials in proper contain- ers. Discard oily or flammable rags. Always use a metal fireplace screen and have chimneys cleaned regularly . Replace worn or damaged sockets, switches, home wiring and cracked or frayed electrical cords and plugs. Do not overload electrical circuits. Keep match ...

  • Ei Electronics Ei 405C - page 19

    19 The Home Office states (in FB2): If your home has more than one floor , at least one alarm should be fitted on each level. In this case, a combination of Optical and Ionisation alarms, preferably interconnected, will give the best protection. 1 1. GETTING YOUR SMOKE ALARM SERVICED If your Smoke Alarm fails to work after you have read the sec- ti ...

  • Ei Electronics Ei 405C - page 20

    20 13. TECHNICAL SPECIFICA TION Battery: Replaceable 9 V olt Alkaline Duracell (Ei405 & 405C only) MN1604, Energizer 522 or Eveready 522. Battery Life: Battery can power unit in standby for over (Ei405 & 405C only) a year . Battery: Built-in Lithium Battery . (Ei405TY & Ei405TYC only) Battery Life: Lasts up to 10 Y ears. (Ei405TY & ...

  • Ei Electronics Ei 405C - page 21

    21 RF RECEPTION External Alarm RF Signal: T urns on horn without red light flashing until it fails to receive alarm confirmation for 1 1 seconds. Stops horn within 3 sec- onds, on receipt of an "Alarm "Cancel" sig- nal (from any unit). Receiver remains on "continuously" for 1 1 seconds to check for further alarm signals. Le ...

  • Ei Electronics Ei 405C - page 22

    22 The blue light will turn on as the button is pressed. Program Mode: Number of fast flashes every 5 seconds indicates number of units (including remote keyfob, Ei410, if used) in system Clearing House Codes: Th e s erial numbers memorised, can be deleted (i.e. the smoke alarms can be uncoded) by powering down the unit and disconnecting the batter ...

  • Ei Electronics Ei 405C - page 23

    23 ...

  • Ei Electronics Ei 405C - page 24

    24 ...

Производитель Ei Electronics Категория Smoke Alarm

Документы, которые мы получаем от производителя устройства Ei Electronics Ei 405C мы можем разделить на несколько групп. Это в частности:
- технические чертежи Ei Electronics
- инструкции обслуживания Ei 405C
- паспорта изделия Ei Electronics
- информационные брошюры
- энергетические этикетки Ei Electronics Ei 405C
Все из них важны, однако самую важную информацию с точки зрения пользователя мы найдем в инструкции обслуживания Ei Electronics Ei 405C.

Группа документов, определяемая как инструкции обслуживания, делится также на более подробные типы, такие как: Инструкции монтажа Ei Electronics Ei 405C, инструкции обслуживания, короткие инструкции или инструкции пользователя Ei Electronics Ei 405C. В зависимости от потребностей, Вам необходимо поискать требуемый документ. На нашем сайте Вы можете просмотреть самую популярную инструкцию использования изделия Ei Electronics Ei 405C.

Похожие инструкции обслуживания

Полная инструкция обслуживания устройства Ei Electronics Ei 405C, как должна выглядеть?
Инструкция обслуживания, определяемая также как пособие пользователя, или просто "руководство" - это технический документ, цель которого заключается в использовании Ei Electronics Ei 405C пользователями. Инструкции пишет, как правило технический писатель, языком, доступным для всех пользователей Ei Electronics Ei 405C.

Полная инструкция обслуживания Ei Electronics, должна заключать несколько основных элементов. Часть из них менее важная, как например: обложка / титульный лист или авторские страницы. Однако остальная часть, должна дать нам важную с точки зрения пользователя информацию.

1. Вступление и рекомендации, как пользоваться инструкцией Ei Electronics Ei 405C - В начале каждой инструкции, необходимо найти указания, как пользоваться данным пособием. Здесь должна находится информация, касающаяся местонахождения содержания Ei Electronics Ei 405C, FAQ и самых распространенных проблем - то есть мест, которые чаще всего ищут пользователи в каждой инструкции обслуживания
2. Содержание - индекс всех советов, касающихся Ei Electronics Ei 405C, которое найдем в данном документе
3. Советы по использованию основных функций устройства Ei Electronics Ei 405C - которые должны облегчить нам первые шаги во время использования Ei Electronics Ei 405C
4. Troubleshooting - систематизированный ряд действия, который поможет нам диагностировать а в дальнейшем очередность решения важнейших проблем Ei Electronics Ei 405C
5. FAQ - чаще всего задаваемые вопросы
6. Контактные данные Информация о том, где искать контактные данные производителя / сервисного центра Ei Electronics Ei 405C в данной стране, если самостоятельно не получится решить проблему.

У вас вопрос, касающийся Ei Electronics Ei 405C?

Воспользуйтесь формуляром, находящимся ниже

Если с помощью найденной инструкции Вы не решили свою проблему с Ei Electronics Ei 405C, задайте вопрос, заполнив следующий формуляр. Если у какого то из пользователей была похожая проблема с Ei Electronics Ei 405C со всей вероятностью он захочет поделиться методом ее решения.

Перепишите текст с картинки

Комментарии (0)