    IE-iMcV-T1/E1/J1-LineTerm SFP and 1x9 Operation Manual Above illustration is representati ve; different m odels av ailable ...

  • IMC Networks IE-IMCV-T1 - page 2

    ii FCC Radio Frequency Inter ference Sta tement This equipment has been tested and found to comply wi th the limi ts fo r a Cla ss A c omput ing d evic e, pursu ant t o Pa rt 15 of the F CC Rules. These limits are designed to pr ovide reasonable protection against harmful interference when the equipment is o perated in a com mercial environment. Th ...

  • IMC Networks IE-IMCV-T1 - page 3

    iii Table of Cont ents FCC Radio Fre quency Interfe rence Stateme nt .................................................... ii Warranty ............ ................................................................. ............................... ii About the IE-iM cV-T1/E1/J1-LineTerm . ............................................................... ...

  • IMC Networks IE-IMCV-T1 - page 4

    1 Abou t the IE -iM cV-T1/E 1/J1 -Line Term, TP/ SFP IE-iMcV-T1/ E1/J1-Line Term, TP/S FP is an SNMP -Manageable m odule that c onverts standard TD M -based c opper transp orts ( T1, E1 , J1) to a single -mode or mul ti-mode fiber signal. It performs a standard “L ine Termination ” function as define d in GR - 820-CORE. This fun ction tran smit ...

  • IMC Networks IE-IMCV-T1 - page 5

    2 NOTE IE-iMcV- T1/E1/J1-L ineTer m, TP/SFP with SFP Module can be installed in an iMed iaChassis and MediaChas sis series. Installing an iMcV-Module iMcV-Modules install in IMC Ne tworks’ SNMP manageable iM ediaChassis series or in any MediaCha ssis/IE-Me diaChassis series. To install an iM cV-Module: 1. Remov e the blank b racket cov ering th e ...

  • IMC Networks IE-IMCV-T1 - page 6

    3 • Required CSU line Buildout (0db t o -22db) • Receiver BOOS T for T1 an d E1 applica tions • Fibe r tra nsceive rs mu st be fo r approp riate fiber r un, i .e. (SM or MM) • Management location must be at HOST unit Managed Modules The IE-iMcV-T1/E1/J1-LineTerm, TP/S FP modules are installed as a HOST-REMOTE pair and can be remotely man ag ...

  • IMC Networks IE-IMCV-T1 - page 7

    4 Conf igur ation Cont rol Some iMcV -Modules offer confi guration c ontrol; lab els on the fr ont faceplate a re identified as such. Configuration control has been implemented to assi st the end user by retaining the latest confi guration re gardle ss of ho w that con figurati on was implemented (via DIP S witch settings or S NMP). Historically, S ...

  • IMC Networks IE-IMCV-T1 - page 8

    5 NOTE If the end user has a mixture of standard iM cV-Modules as well as Configura tion Control iMcV-Modules, it is important to understand how SNMP and DIP Switches will impact the cards depending on their capa bility. Sta nda rd iMcV-Modul es cannot be upgrade d to Config ur atio n Co ntrol cap abilit y, s o it is str o ngly recomme nded to set ...

  • IMC Networks IE-IMCV-T1 - page 9

    6 DIP Switches The IE-iMcV-T1/E1/J1 -LineTerm, TP /SFP DI P Switches are locate d on S2 an d S3 on the PCB. T he loca tion of the S2 a nd S3 DIP Switches are displayed in the following diag ram : ...

  • IMC Networks IE-IMCV-T1 - page 10

    7 DIP Sw it ch S et ting s (S2 , S3) Switch Sett ings for Switch S2 T1/E1 Selec tion S2-1: OFF T1 Mode Selected default S2-1: O N E1 Mode Sele cted Receive Equaliz er Gain Limit (EGL) E1 iVIE W 2 S2-2: ON -12 dB (Short Haul) iVIE W 2 S2-2: OFF -43 dB (Long Haul) iVIE W 2 T1 iVIE W 2 S2-2: ON -36 dB (Long Haul) iVIE W 2 S2-2: OFF -30 dB (Limited Lon ...

  • IMC Networks IE-IMCV-T1 - page 11

    8 Switch Sett ings for Sw itch S3 Rese rve d S3-1: ON Reserved S3-1: OFF Reserved def ault Remo te Mana gemen t S3-2: ON Remote Management Enabled (only at the REMOTE end) S3-2: OF F Remote Ma nagement Disab led (onl y at th e LOCAL end) default Loopback Selection iVIEW 2 S3-3: ON S3-4: ON None iVIE W 2 default S3-3: OFF S3-4: ON Fiber Analog Loopb ...

  • IMC Networks IE-IMCV-T1 - page 12

    9 Featu re s The IE-iMcV-T1/E1/J1-LineTerm, TP/S FP module includes sever al feature s to facilitate maintenance and troubleshooting in an y T1/E1/J1 based TDM environment. SFP SFPs wit h Data and Diagn ostics Management Information (DD MI) can be in stalle d in the SFP port of the h ost and the remot e. Th is allows the end user to vie w the DDMI ...

  • IMC Networks IE-IMCV-T1 - page 13

    10 Loopback Modes This feature allows thre e distinct Loopba cks to be activated eit her through DIP Switches or iView 2 Management. Fiber Loopback An ana log Loopb ack at th e copper po rt back to t he fib er por t. It copies the received optical signal back to the optical line at t he copper port and c ontinu es to driv e the copper p ort, but ca ...

  • IMC Networks IE-IMCV-T1 - page 14

    11 Fault Loopback This switch enables or disables the Fault Loopback feature on the copper port. A normal copper line LOS fault will cause a Rem ote Alarm Indict or (RAI) to be sent on to the fiber line segment causing the n ormal AIS to be sent on the far en d copper port. The fau lt loop back fe ature provi des fo r a fault indica tion to be sent ...

  • IMC Networks IE-IMCV-T1 - page 15

    12 T1, E1 and J1 Selecti on This switch selects the data r ate to use on the copper line. The data rate selections available include the following: • T1/J1 (1.544 Mbps +/- 32 ppm) • E1 (2.04 8 Mbps +/- 32 ppm) By def ault this feature is set to T1. This feature can be selected onl y by setting the DIP S witches manually. Remote Management A DIP ...

  • IMC Networks IE-IMCV-T1 - page 16

    13 LED Operation The IE-iMcV-T1/E1/J1-LineTerm, TP/S FP module features seve ral diagnostic LEDs per port. The following L ED display function s are provid ed: Copper P ort LEDs ER Flashes yellow whe never a line code violation is received. LOS Glows red whe n the R J-48 is receiving n o signal and is in an LOS ALARM state. This condition will also ...

  • IMC Networks IE-IMCV-T1 - page 17

    14 Loopback Tes ting The IE-iMcV-T1 /E1/J1-LineTerm , TP/SFP incl udes three Loopback test m odes: Copper Loopback, Fibe r Loopback and I nternal Fiber Loopback. The follow ing illustrations show a typical prog ression of Loopback tests (i.e., starting by checking the copper segment at the l o cal side, then the fiber segment at the REMOTE side, et ...

  • IMC Networks IE-IMCV-T1 - page 18

    15 Pseud orandom Bit Sequence (PRB S) Testing To test usin g PRBS, con figure the IE-i McV- T1/ E1/J1 -LineTerm, TP/SFP m odules for No Loopback , and then confi gure th e Transmit Copper Dat a Source to P RBS. Config ure the lo cal device f or Loop back and st art the te st. Verif y the PRBS L ED is ON indicatin g no errors are being r eceive d. I ...

  • IMC Networks IE-IMCV-T1 - page 19

    16 Use the following LED in dications to identify the fa ult location: *DIP Switch S3-7 m ust be set t o ON for Fault Loopback to operate as illustrate d. The fo llowi ng table l ists the pi n configu ration for th e RJ-48 connecto r. Pin Signal 1 Receive Ring 2 Receive Tip 3 No Connection 4 Transmit R ing 5 Transmit Tip 6 No Connection 7 No Connec ...

  • IMC Networks IE-IMCV-T1 - page 20

    17 Spec if icat io ns Standard s Com pliance (T1, E1, J1): ANSI T1.102 -1993 ANSI T1.107.199 5 GR-820- CORE T1, E1, J1 Inter face: T1 (1.544 Mbps +/- 32 ppm) E1 (2.048 Mb ps +/- 32 ppm) J1 (1.544 Mbps +/- 32 ppm ) Power Consumption (Typical ): 0.550 Amps @ 5 V Operatin g Temp eratur e: -4°F to +158°F (-2 0°C to +70°C) Storage T empe rature : -4 ...

  • IMC Networks IE-IMCV-T1 - page 21

    18 Fiber Op tic Cleaning Guide lines Fiber Optic tran smitters an d receivers are e xtremely susce ptible to c ontamination by particles of d irt o r dust, which can obst ruct the optic p ath and cause performance degradation. Good system performan ce requires clean optics and c onnector ferrules. 1. Use fiber patch cord s (or connectors, if you te ...

  • IMC Networks IE-IMCV-T1 - page 22

    19 El ectro sta ti c Dis charg e Pre cau tions Electrostatic discharge (ESD) can cause dama ge to any product, add- in modules or stand alone units, containing ele ctronic componen ts. Always observe the following precauti ons when installing or han dling these kinds o f products 1. Do not remove unit from its protecti ve pa ckagin g until ready t ...

  • IMC Networks IE-IMCV-T1 - page 23

    20 Certi fic at ions CE: The products des cribed herein c o mply with the Counci l Directiv e on Electromagne tic Compatibili ty (2004/108/EC) European Directive 2002/96/EC (WEEE) requir es that any equipment that bears this symbol on product or pa ckaging m ust n ot be d ispose d of wit h unsorte d munic ipal waste. This symbol in dicates that the ...

  • IMC Networks IE-IMCV-T1 - page 24

    19772 Pauling • Foothill Ranc h, CA 92610-26 11 USA TEL: (94 9) 465 -3000 • FAX: (949 ) 465 -3020 www.imcnetworks.com © 2011 I MC Networks. A ll righ ts reserved . The info rmation in this doc ument is su bject to cha nge with o ut no tice . IM C N etwo rk s a ssum es no re spon sibi lity for an y errors th at may appear in this document. IE-i ...

Производитель IMC Networks Категория Network Card

Документы, которые мы получаем от производителя устройства IMC Networks IE-IMCV-T1 мы можем разделить на несколько групп. Это в частности:
- технические чертежи IMC Networks
- инструкции обслуживания IE-IMCV-T1
- паспорта изделия IMC Networks
- информационные брошюры
- энергетические этикетки IMC Networks IE-IMCV-T1
Все из них важны, однако самую важную информацию с точки зрения пользователя мы найдем в инструкции обслуживания IMC Networks IE-IMCV-T1.

Группа документов, определяемая как инструкции обслуживания, делится также на более подробные типы, такие как: Инструкции монтажа IMC Networks IE-IMCV-T1, инструкции обслуживания, короткие инструкции или инструкции пользователя IMC Networks IE-IMCV-T1. В зависимости от потребностей, Вам необходимо поискать требуемый документ. На нашем сайте Вы можете просмотреть самую популярную инструкцию использования изделия IMC Networks IE-IMCV-T1.

Похожие инструкции обслуживания

Полная инструкция обслуживания устройства IMC Networks IE-IMCV-T1, как должна выглядеть?
Инструкция обслуживания, определяемая также как пособие пользователя, или просто "руководство" - это технический документ, цель которого заключается в использовании IMC Networks IE-IMCV-T1 пользователями. Инструкции пишет, как правило технический писатель, языком, доступным для всех пользователей IMC Networks IE-IMCV-T1.

Полная инструкция обслуживания IMC Networks, должна заключать несколько основных элементов. Часть из них менее важная, как например: обложка / титульный лист или авторские страницы. Однако остальная часть, должна дать нам важную с точки зрения пользователя информацию.

1. Вступление и рекомендации, как пользоваться инструкцией IMC Networks IE-IMCV-T1 - В начале каждой инструкции, необходимо найти указания, как пользоваться данным пособием. Здесь должна находится информация, касающаяся местонахождения содержания IMC Networks IE-IMCV-T1, FAQ и самых распространенных проблем - то есть мест, которые чаще всего ищут пользователи в каждой инструкции обслуживания
2. Содержание - индекс всех советов, касающихся IMC Networks IE-IMCV-T1, которое найдем в данном документе
3. Советы по использованию основных функций устройства IMC Networks IE-IMCV-T1 - которые должны облегчить нам первые шаги во время использования IMC Networks IE-IMCV-T1
4. Troubleshooting - систематизированный ряд действия, который поможет нам диагностировать а в дальнейшем очередность решения важнейших проблем IMC Networks IE-IMCV-T1
5. FAQ - чаще всего задаваемые вопросы
6. Контактные данные Информация о том, где искать контактные данные производителя / сервисного центра IMC Networks IE-IMCV-T1 в данной стране, если самостоятельно не получится решить проблему.

У вас вопрос, касающийся IMC Networks IE-IMCV-T1?

Воспользуйтесь формуляром, находящимся ниже

Если с помощью найденной инструкции Вы не решили свою проблему с IMC Networks IE-IMCV-T1, задайте вопрос, заполнив следующий формуляр. Если у какого то из пользователей была похожая проблема с IMC Networks IE-IMCV-T1 со всей вероятностью он захочет поделиться методом ее решения.

Перепишите текст с картинки

Комментарии (0)