    Revision 1.3 Page i ® ® TLM100 Tank Level Monitor User’s Manual Revision 1.3 Copyright © 2010 Maretron, LLP All Rights Reserved Maretron, LLP 9014 N. 23 rd Ave #10 Phoenix, AZ 85021 http://www.maretron.com Maretron Manual Part #: M002201 ...

  • Maretron TLM100 - page 2

    TLM100 User’s Manual Page ii Revision 1.3 Revision History Revision Description 1.0 Original document 1.1 Corrected typo in NMEA protocol PGN list 1.2 Typographical corrections 1.3 Added documentation on mounting locations and theory of operation Corrected torque specifications Added prohibition of red Loctite thr eadlocking compound and cleaning ...

  • Maretron TLM100 - page 3

    Revision 1.3 Page iii ® ® Table of Contents 1  General ....................................................................................................................... ......... 1  1.1  Introduc tion .................................................................................................................. .. 1  1.2  ...

  • Maretron TLM100 - page 4

    TLM100 User’s Manual Page iv Revision 1.3 Table of Figures Figure 1 - TLM 100 Operat ion ................................................................................................... . 3  Figure 2 – TLM100 Mounting – S AE 5-Hole Bolt Pattern .......................................................... 6  Figure 3 – Mounting TLM100 ...

  • Maretron TLM100 - page 5

    Revision 1.3 Page 1 ® ® 1 General 1.1 Introduction Congratulations on your purchase of the Mare tron Tank Level Monitor (TLM100). Maretron has designed and built your monitor to the highest standards for year s of reliable, dependable, and accurate service. The TLM100 is used to sense levels of liquid tanks using ultrasonic technology and tr ansm ...

  • Maretron TLM100 - page 6

    TLM100 User’s Manual Page 2 Revision 1.3 1.5 TLM100 Accessories Maretron offers the following accessories for the TLM100: • TA-5H-1.5NPT 1.5” NPT Dis placement Hull Tank Adapter • TA-5H-1.25BSP 1.25” BSP Displ acement Hull Tank Adapter • TFT-5H SAE 5-Bolt Pattern N on-Displacement Hull Focus Tube • TFT-1.5NPT 1.5” NPT Non-Displaceme ...

  • Maretron TLM100 - page 7

    ® ® then be received back at the sensor component. Usi ng the speed of sound, it uses this time to calculate the distance between the face of the sensor component and the surface of the liquid (or the tank bottom if the tank is empty). The cone width of the beam transmitted by the TLM100 sensor component is 6°. Please refer to Figure 1 below for ...

  • Maretron TLM100 - page 8

    TLM100 User’s Manual Page 4 Revision 1.3 • The sensor component of the TLM100 mu st be mounted over the deepest part of the tank, in order to obtain accurate dept h readings when the tank is empty or near empty. • In order to obtain accurate readings w hen the tank is empt y, the tank bottom directly under the TLM100 must be both smooth and f ...

  • Maretron TLM100 - page 9

    ® ® 2.4 Mounting the TLM100 2.4.1 Mounting the TLM100 Sensor Component The TLM100 comes from the factory ready to mount on a tank with the standard SAE J1810 5- Hole mounting pattern. Maretron offers adapters to allow mounting the TLM100 on a tank with a 1.5” NPT connection or a 1.25” BSP connection. WARNING • Gasket installs only one way a ...

  • Maretron TLM100 - page 10

    TLM100 User’s Manual TLM100 Sensor Component TLM100 Interface Component SAE 5-Bolt Tank Fitting TLM100 Gasket Mounting Screws (x5) Figure 2 – TLM100 Mounting – SAE 5-Hole Bolt Pattern 2.4.1.2 Installation on a Tank with a SA E J1810 5-Bolt Fitting and Focus Tube If a focus tube is used for a tank with a SAE J1810 5-bolt fitting, determine the ...

  • Maretron TLM100 - page 11

    ® ® Focus Tube Gasket Focus Tube TLM100 Gasket TLM100 Sensor Component Mounting Screws (x5) SAE 5-Bolt Tank Fitting TLM100 Interface Component 1” (2.54cm) clearance between focus tube and tank bottom Figure 3 – Mounting TLM100 to SA E 5-Hole Tank with Focus Tube 2.4.1.3 Installation on a Tank with a SA E J1810 5-Bolt Fitting and Airlock Insta ...

  • Maretron TLM100 - page 12

    TLM100 User’s Manual TLM100 Interface Component Threaded Tank Fitting Threaded Adapter TLM100 Gasket TLM100 Sensor Component Mounting Screws (x5) Figure 4 – TLM100 Mounting With Threaded Adapter 2.4.1.5 Installation on a Tank with a 1.25”BSP or 1.5”NPT Threaded Tank Fitting and Focus Tube If a focus tube is used for a tank with a SAE J1810 ...

  • Maretron TLM100 - page 13

    ® ® 1” (2.54cm) clearance between focus tube and tank bottom TLM100 Interface Component Threaded Tank Fitting Threaded Focus Tube TLM100 Gasket TLM100 Sensor Component Mounting Screws Figure 5 – Mounting TLM100 with Foc us Tube on Threaded Tank Fitting 2.4.1.6 Installation on a Tank with a 1.25”BSP or 1.5”NPT Threaded Tank Fitting and Air ...

  • Maretron TLM100 - page 14

    TLM100 User’s Manual 2.5 Connecting the TLM100 There is one connection point (see Figure 6 ) for the TLM100: the NMEA 2000 ® connection. Please refer to Section 2.5.1 for making NMEA 2000 ® connection. Page 10 Revision 1.3 Figure 6 – TLM100 Connections 2.5.1 Connecting to NMEA 2000 ® Interface The Maretron TLM100 provides a connection to an ...

  • Maretron TLM100 - page 15

    Revision 1.3 Page 11 ® ® 3 Configuring the TLM100 The TLM100 has several configurable paramete rs, which are shown below including the default values. If you are not using the defaul t values, then you will need to refer to the corresponding section for confi guring the TLM100 appropriately. 1. Tank Type (Section 3.1 ) – Default is Fuel 2. Tank ...

  • Maretron TLM100 - page 16

    TLM100 User’s Manual Page 12 Revision 1.3 software. Refer to the user’s manual of the particular product t hat will be used for configuring the TLM100 as these manuals pr ovide detailed instruction on configuration procedures. 3.4 Tank Depth or Custom Calibration The TLM100 can be easily programmed for use wi th tanks of rectangular cross-secti ...

  • Maretron TLM100 - page 17

    Revision 1.3 Page 13 ® ® Symptom Troubleshooting Procedure No tank level output 1. If operating in the NMEA 2000 ® Mode , check the connection to the NMEA 2000 ® interface (see Section 2.5.1 ) and tighten if necessary. 2. Ensure that power is supplied to the NMEA 2000 ® network. Proper network power can be checked by m easuring the voltage at ...

  • Maretron TLM100 - page 18

    TLM100 User’s Manual Page 14 Revision 1.3 6 Technical Specifications Specifications Parameter Value Comment Accuracy ±2% Resolution ± 1% Number of Tank Types 16 Fuel, Fresh Water, Waste Water, Live Well, Oil, etc. Number of Tanks per Tank Type 16 16 Tanks per Tank Type Numbe red 0-15 Maximum Tank Depth 40” (1.02m) Minimum Depth Reading 2” ( ...

  • Maretron TLM100 - page 19

    Revision 1.3 Page 15 ® ® Mechanical Parameter Value Comment Size 3.9”” x 1.2” x 1.0” (99mm x 30.5mm x 25.4mm) Interface Component 2.7” dia. X 0.9” (68.6mm dia. x 22.9mm) Sensor Component 8.5” (215.9mm) Interconnecting Cable Weight 12 oz. (340g) Mounting SAE J1810 5-hole bolt pattern Can mount to 1.25” BSP or 1.5” NPT using avail ...

  • Maretron TLM100 - page 20

    TLM100 User’s Manual Page 16 Revision 1.3 8 Maretron (2 Year) Limited Warranty Maretron warrants the TLM100 to b e free from defects in materials and workm anship for two (2) years from the date of original purchase. If within the applicable per iod any such products shall be p roved to Maretron’s satisfaction to fail to meet the above lim ited ...

  • Maretron TLM100 - page 21

    Revision 1.3 Appendix A – NMEA 2000 ® Interfacing Page A1 ® ® Appendix A – NMEA 2000 ® Interfacing TLM100 NMEA 2000 ® Periodic Data Transmitted PGNs PGN 127505 – Fluid Level The TLM100 uses this PGN to indicate the attached tank’s fluid instance, fluid type, fluid level, and tank capacity. Field 1: Fluid Instance – This field is us e ...

Производитель Maretron Категория Computer Monitor

Документы, которые мы получаем от производителя устройства Maretron TLM100 мы можем разделить на несколько групп. Это в частности:
- технические чертежи Maretron
- инструкции обслуживания TLM100
- паспорта изделия Maretron
- информационные брошюры
- энергетические этикетки Maretron TLM100
Все из них важны, однако самую важную информацию с точки зрения пользователя мы найдем в инструкции обслуживания Maretron TLM100.

Группа документов, определяемая как инструкции обслуживания, делится также на более подробные типы, такие как: Инструкции монтажа Maretron TLM100, инструкции обслуживания, короткие инструкции или инструкции пользователя Maretron TLM100. В зависимости от потребностей, Вам необходимо поискать требуемый документ. На нашем сайте Вы можете просмотреть самую популярную инструкцию использования изделия Maretron TLM100.

Похожие инструкции обслуживания

Полная инструкция обслуживания устройства Maretron TLM100, как должна выглядеть?
Инструкция обслуживания, определяемая также как пособие пользователя, или просто "руководство" - это технический документ, цель которого заключается в использовании Maretron TLM100 пользователями. Инструкции пишет, как правило технический писатель, языком, доступным для всех пользователей Maretron TLM100.

Полная инструкция обслуживания Maretron, должна заключать несколько основных элементов. Часть из них менее важная, как например: обложка / титульный лист или авторские страницы. Однако остальная часть, должна дать нам важную с точки зрения пользователя информацию.

1. Вступление и рекомендации, как пользоваться инструкцией Maretron TLM100 - В начале каждой инструкции, необходимо найти указания, как пользоваться данным пособием. Здесь должна находится информация, касающаяся местонахождения содержания Maretron TLM100, FAQ и самых распространенных проблем - то есть мест, которые чаще всего ищут пользователи в каждой инструкции обслуживания
2. Содержание - индекс всех советов, касающихся Maretron TLM100, которое найдем в данном документе
3. Советы по использованию основных функций устройства Maretron TLM100 - которые должны облегчить нам первые шаги во время использования Maretron TLM100
4. Troubleshooting - систематизированный ряд действия, который поможет нам диагностировать а в дальнейшем очередность решения важнейших проблем Maretron TLM100
5. FAQ - чаще всего задаваемые вопросы
6. Контактные данные Информация о том, где искать контактные данные производителя / сервисного центра Maretron TLM100 в данной стране, если самостоятельно не получится решить проблему.

У вас вопрос, касающийся Maretron TLM100?

Воспользуйтесь формуляром, находящимся ниже

Если с помощью найденной инструкции Вы не решили свою проблему с Maretron TLM100, задайте вопрос, заполнив следующий формуляр. Если у какого то из пользователей была похожая проблема с Maretron TLM100 со всей вероятностью он захочет поделиться методом ее решения.

Перепишите текст с картинки

Комментарии (0)