Bedienungsanleitung National Instruments Isolated Analog Output Module SCC-AO10

12 Seiten 0.29 mb
Download

Zur Seite of 12

Summary
  • National Instruments Isolated Analog Output Module SCC-AO10 - page 1

    USER GUIDE SCC-AO10 Isolated Analog Output Module The SCC-AO10 is an isolated voltage output module wit h an output range of ±10 V. The output voltage level is controlled by the DA C output of an E/M Series DAQ device. You can incr ease the output voltage level to ±20 V by connect ing two SCC-AO 10 modules in series. Conventions The following con ...

  • National Instruments Isolated Analog Output Module SCC-AO10 - page 2

    SCC-AO10 Isolated Analog Output Module Use r Guide 2 ni.com monospace T e xt in this font denotes text or ch aracters that you should enter from the keyboard, sections of code, programming examples, and syntax examples. This font is also used for the proper na mes of disk dri ves, paths, directories, programs, subprograms, su broutines, d e vice na ...

  • National Instruments Isolated Analog Output Module SCC-AO10 - page 3

    © National Instruments Corpor ation 3 SCC-AO10 Isolated Analog Output Mo dule U ser Guide Note Software scaling of measurements is not supported on the Macintosh operating system. Refer to the SCC-AO10 Connector Pin Assignments section. Y ou can do wnload NI documents from ni.com/manuals . T o do wnload the latest version of NI-D A Qmx, click Do w ...

  • National Instruments Isolated Analog Output Module SCC-AO10 - page 4

    SCC-AO10 Isolated Analog Output Module Use r Guide 4 ni.com Figures 1 and 2 show the SCC-A O10 c onnected to a nonreferenced load and to a load w ith a hi gh common-mode voltage. Figure 1. SCC-AO10 Connected to a Nonreferenced Load Figure 2. SCC-AO10 Connected to a Load with a High Common-Mode Voltage Connecting T wo SCC-AO10 Modules in Series You ...

  • National Instruments Isolated Analog Output Module SCC-AO10 - page 5

    © National Instruments Corpor ation 5 SCC-AO10 Isolated Analog Output Mo dule U ser Guide Figure 3. Connecting T wo SCC-AO10 Modules in Series The SC-2345/2350 routes the E/M Series D A Q device analog output channels A O 0 and A O 1 to the SCC-A O10 modules, and the resu lting maximum output voltage range is ±20 V . Refer to Figure 3 and use the ...

  • National Instruments Isolated Analog Output Module SCC-AO10 - page 6

    SCC-AO10 Isolated Analog Output Module Use r Guide 6 ni.com Using the SCC-AO10 This section contains information regarding scali ng voltage measurements and isolated ground references. Scaling V oltage Measurements The SCC-AO10 is a ±10 V isolated analog output module. The output voltage is controlled by an E/M Series DAQ device AO output channel, ...

  • National Instruments Isolated Analog Output Module SCC-AO10 - page 7

    © National Instruments Corpor ation 7 SCC-AO10 Isolated Analog Output Mo dule U ser Guide 5. Adjust the offset potentiometer on the top of the SCC-A O10 unt il the voltmeter reads 0 VDC ±100 μ V . The of fset is no w calibrated. 6. Using your software, hav e A O ( X ) output 9.9 VDC. Adjust the gain potentiometer on the to p of the SCC-A O10 unt ...

  • National Instruments Isolated Analog Output Module SCC-AO10 - page 8

    SCC-AO10 Isolated Analog Output Module Use r Guide 8 ni.com Power Requirement Analog power ............... ................. .........180 mW max at full load 172 mW max w ith no load + 15 V .... ................. .............. ............6 mA max at full load 5.73 mA max with no load –15 V ............ ................. .............. ....6 mA ...

  • National Instruments Isolated Analog Output Module SCC-AO10 - page 9

    © National Instruments Corpor ation 9 SCC-AO10 Isolated Analog Output Mo dule U ser Guide Maximum W orking Voltage (Signal + common- mode) each input should remain within 42.4 V peak or 60 VDC of ground. Maximum working voltage refers to the signal voltage plus the CMV . Channel-to-earth (inputs) ....................... 42.4 V peak or 60 VDC, Meas ...

  • National Instruments Isolated Analog Output Module SCC-AO10 - page 10

    SCC-AO10 Isolated Analog Out put Module Use r Guide 10 ni.com Safety This product meets the requirements of the follow ing standards of safety for electrical equipment for measurement, contro l, and laboratory use: • IEC 61010-1, EN 61010-1 • UL 61010-1, CSA 61010-1 Note For UL and other safety certifications , refer to the product label or th ...

  • National Instruments Isolated Analog Output Module SCC-AO10 - page 11

    © National Instruments Corpor ation 11 SCC-AO10 Isolat ed Analog Output Module User Guide Environmental Management NI is committed to designing and manufacturing products in an environmentally responsible man ner. NI recognizes that eliminating certain hazardous substances from our products is beneficial to the environment and to NI customers. For ...

  • National Instruments Isolated Analog Output Module SCC-AO10 - page 12

    National Instruments, NI, ni.com, and LabVIEW are tradem arks of National Instruments Corporation. Refer to t he Terms of Use section on ni.com/legal for mor e information a bout National Instruments trademarks. Other product and compan y names mentioned herein are trademarks or trad e names of their respective companie s. For patents covering Nati ...

Produzent National Instruments Kategorie Network Card

Dokumente, die wir vom Produzenten des Geräts National Instruments Isolated Analog Output Module SCC-AO10 erhalten, können wir in mehrere Gruppen teilen. Unteranderem in:
- technische Zeichnungen National Instruments
- Bedienungsanleitungen Isolated Analog Output Module SCC-AO10
- Produktkarten National Instruments
- Informationsbroschüren
- oder Energieetiketten National Instruments Isolated Analog Output Module SCC-AO10
Jede von ihnen ist wichtig, jedoch finden wir die wichtigsten Informationen für den Nutzer des Geräts in der Bedienungsanleitung National Instruments Isolated Analog Output Module SCC-AO10.

Die Dokumentengruppe, die als Bedienungsanleitungen bezeichnet wird, wird ebenfalls in detaillierte Arten geteilt, solche wie: Montageanleitungen National Instruments Isolated Analog Output Module SCC-AO10, Wartungsanleitungen, Kurzanleitungen oder Benutzeranleitungen National Instruments Isolated Analog Output Module SCC-AO10. Abhängig vom Bedarf, sollten Sie das Dokument finden, das Sie brauchen. In unserem Service können Sie sich die populärste Bedienungsanleitung des Produkts National Instruments Isolated Analog Output Module SCC-AO10 ansehen.

Die komplette Bedienungsanleitung des Geräts National Instruments Isolated Analog Output Module SCC-AO10, wie sollte sie aussehen?
Die Bedienungsanleitung, auch bezeichnet als Benutzerhandbuch, oder einfach nur „Anleitung”, ist ein technisches Dokument, das dem Benutzer bei der Nutzung von National Instruments Isolated Analog Output Module SCC-AO10 hilfreich sein soll. Die Bedienungsanleitungen werden in der Regel von technischen Schriftstellern geschrieben, aber in einer Sprache, die für alle Nutzer von National Instruments Isolated Analog Output Module SCC-AO10 verständlich ist.

Eine gänzliche Bedienungsanleitung von National Instruments sollte einige Grundelemente enthalten. Ein Teil von ihnen ist nicht so wichtig, wie z.B.: die Titelseite oder Autorenseiten. Die restlichen von ihnen jedoch, sollten Informationen liefern, die für den Nutzer von enormer Wichtigkeit sind.

1. Einführung und Hinweise, wie man sich in einer Bedienungsanleitung von National Instruments Isolated Analog Output Module SCC-AO10 bewegt - Am Anfang jeder Bedienungsanleitung sollten wir Hinweise bezüglich der Nutzungsart eines bestimmten Ratgebers finden. In ihr sollten sich Informationen über die Lokalisierung des Inhaltsverzeichnisses von National Instruments Isolated Analog Output Module SCC-AO10 befinden, FAQ oder über oft auftretende Probleme – also Stellen, die von den Benutzern in jeder Bedienungsanleitung am meisten gesucht werden
2. Inhaltsverzeichnis - Index aller Ratschläge bezüglich National Instruments Isolated Analog Output Module SCC-AO10, die wir im aktuellen Dokument finden
3. Ratschläge zur Nutzung der Grundfunktionen des Geräts National Instruments Isolated Analog Output Module SCC-AO10 - die uns die ersten Schritte während der Nutzung von National Instruments Isolated Analog Output Module SCC-AO10 erleichtern sollten
4. Troubleshooting - geordneter Tätigkeitslauf, der uns bei der Diagnose und als nächstes bei der Lösung wichtiger Probleme mit National Instruments Isolated Analog Output Module SCC-AO10 hilft
5. FAQ - häufig gestellte Fragen
6. Kontaktdaten Informationen darüber, wo man Kontakt zum Produzenten / Service von National Instruments Isolated Analog Output Module SCC-AO10 im bestimmten Land suchen kann, wenn es nicht gelingt, das Problem selbst zu lösen.

Haben Sie eine Frage bezüglich National Instruments Isolated Analog Output Module SCC-AO10?

Nutzen Sie das untere Formular

Wenn Sie mit Hilfe der gefundenen Bedienungsanleitung Ihr Problem mit National Instruments Isolated Analog Output Module SCC-AO10 nicht gelöst haben, stellen Sie eine Frage, indem Sie das untere Formular nutzen. Wenn einer der Nutzer ein ähnliches Problem mit National Instruments Isolated Analog Output Module SCC-AO10 hatte, ist es möglich, dass er mit Ihnen die Lösung teilen möchte.

Text vom Bild übertragen

Kommentare (0)